• 제목/요약/키워드: energy loss

검색결과 3,491건 처리시간 0.035초

유입 선회류에 대한 디퓨져 손실 및 난류특성에 관한 연구 (A Study on Pressure Loss and Turbulent Charactristics in a Conical Diffuser with a Swirl Flow)

  • 정효민;고대권;양정규
    • 수산해양기술연구
    • /
    • 제28권2호
    • /
    • pp.157-163
    • /
    • 1992
  • In this paper, the relationship between static pressure recovery and turbulent energy was presented in case of swirling flows into a conical diffuser. The distributions of turbulent energy in a diffuser sectional area were measured by a hot wire anemometer. The following conclusion can be drawn from the experiment. Diffuser loss is constituted by a dynamic pressure loss and total pressure loss. The static pressure recovery depends strongly on the total pressure loss. The static pressure recovery depends strongly on the total pressure loss, and the turbulent energy varies inversely as the static pressure recovery coefficient.

  • PDF

The Proposal of a Quantitative Evaluation Method on Mixing Loss in the HVAC System Design

  • Yee, Jurng-Jae;Kim, Young-Tae
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제9권2호
    • /
    • pp.62-68
    • /
    • 2001
  • It is a serous subject for energy conservation to prevent the energy loss caused by the mixture of heated and cooled air jets in perimeter and interior zone of a building operated with tow kinds of air-conditioning system simultaneously. The purpose of this paper is to clarify the quantitative and qualitative mechanisms of mixing loss and to propose a evaluation method for it. By using the dynamic heat load calculation, heat extraction load of a typical office building in Busan are calculated. According to the results, numerical simulations based on CFD(Computational Fluid Dynamics) were performed in order to evaluate mixing loss in the physical size of HVAC system. Then, the distributions of air temperature and airflow patterns according to the differences of set-point temperature are analyzed to grasp relations how to influence mixing loss.

  • PDF

공기조화설비(HVAC) 설계시 혼합손실의 정량적 평가방안의 제안 (The Proposal of a Quantitative Evaluation Method on Mixing Loss in the HVAC System Design)

  • 이정재
    • 설비공학논문집
    • /
    • 제12권10호
    • /
    • pp.879-885
    • /
    • 2000
  • It is a serious subject for energy conservation to prevent the energy loss caused by mixing of heated and cooled air jets in a building which two types of air-conditioning systems are adopted in perimeter and interior zone. The purpose of this paper is to clarify the quantitative and qualitative mechanisms of the mixing loss and to propose preventive methods for it. In this paper, by using the dynamic heat load calculation method, heat extraction loads of a typical office building in Pusan are calculated. According to the results, numerical simulation based on the computational fluid dynamics were peformed in order to measure the mixing loss in physical size HVAC system. Then, the distributions of air temperature and velocity are analyzed in order to grasp the relations by setting temperature differences influence on the mixing loss.

  • PDF

고속철도 차량 벽면의 투과손실값 예측 (Transmission Loss Prediction of the High Speed Railway's Wall Section)

  • 김관주;박진규
    • 한국철도학회논문집
    • /
    • 제9권1호
    • /
    • pp.1-6
    • /
    • 2006
  • The purpose of this study is to calculate transmission loss of the high speed railway's wall section accurately. Transmission loss measurement of ideal case i.e. the wall in the laboratory condition was carried out in first, which results were compared with those by statistical energy method. Transmission loss values of high speed railway calculated out by experimental method are compared with those from closed form solution. Commercial statistical energy analysis was also used to predict the outside pressure level using those measured transmission loss values. Simple SEA model could estimate reasonable exterior sound pressure level.

기존 노후건축물의 최적 리모델링 개선안 연구 (Analysis on Energy Demand Resulting From the Change in Window Area & Installation of Interior Exterior Blinds)

  • 김대원;정광섭;김영일;남아리새;오세민
    • 에너지공학
    • /
    • 제23권2호
    • /
    • pp.207-216
    • /
    • 2014
  • 에너지손실을 분석해 보면 열전달에 의한 손실과 공기유동에 의한 손실로 구분할수 있다. 열전달은 외벽, 지붕, 바닥의 열관류율에 의한 손실로 기존건축물의 가장 취약한 부분의 한 요소이다. 이런 손실을 방지 하려면 창을 포함한 외벽 전체의 평균 열관류율을 지역 기준값 이상으로 올리고 창의 기밀성을 확보함에 따라 방지 할수 있다. 노후건축물의 가장 취약한 부분이 외벽과 창호 이지만 출입문을 통한 침기량은 연돌효과에 의해 층계단을 타고 올라감과 동시에 각층의 공기를 흡입하여 더큰 유동을 잃으켜 층의 단열성 까지 취약하게 만드는 구조로 되어 있다. 현장 조사를 통한 진단과 에너지 개선처방이 제시될 때 반드시 건물전체에 대한 진단과 각층 부분에 대한 개선안이 함께 제출되어 단순히 창 교체만 하면 에너지절감을 이룰수 있다는 착각에서 벗어나야 할 것이다.

에너지 성능 기반의 기계설비배관 단열기준 개선을 위한 연구 (The Study to Improve the Insulation Standards for Mechanical Pipes based on Energy Performance)

  • 윤희원;류형규
    • 한국지열·수열에너지학회논문집
    • /
    • 제17권4호
    • /
    • pp.28-35
    • /
    • 2021
  • The need for zero-energy building is increasing as a means of actively responding to climate change. Since pipe insulation is a factor that minimizes heat loss of cooling and heating facilities, it is necessary to check pipe insulation standards and prepare improvement plans of preparation for certification of zero energy buildings. In this study, domestic pipe insulation standards were checked to prepare new insulation standards based on energy performance. Through the development of a pipe insulation calculation program, the heat loss according to the insulation thickness of the piping for mechanical facilities was compared and reviewed. As a result, applying the insulation thickness of the KCS standard for the same conditions increased the heat loss by an average of 10% compared to the ASHRAE standard. For this reason, it is necessary to revise the pipe insulation thickness standard in consideration of heat loss due to thermal conductivity and pipe insulation thickness. Using the program in this paper, it is possible to design pipe insulation based on energy performance and help to determine the standard for pipe insulation thickness.

한국인의 에너지 소비량에 관한 연구 (A Study on Energy expenditure in Korean Adult)

  • 오승호
    • Journal of Nutrition and Health
    • /
    • 제22권6호
    • /
    • pp.423-437
    • /
    • 1989
  • A 4-week energy balance study was conducted to estimate the energy expenditure (EE) of 16 college age men and women, 20 to 26 year of age, by measurement of energy intakes and changes in body energy(BE) content(intake/balance technique), keeping their normal living pattern and maintenance body weight. Energy intake was measured by bomb calorimetry and estimated by food table. Fecal energy loss was calculated from nitrogen excreted. Fat mass was determined from body density estimated from skinfold tickness. 1) Gross energy (GE) intakes calculated from food table was not only 13.4% lower than those of bomb calorimetry but also lower 4 and 5% than metabolizable energy(ME) intakes for the male and female subjects, respectively. 2) Fecal energy loss was 7.2% and 6.9% proportion of the gross energy intake for the male and female subjects, respectively. 3) Mean daily metabolizable energy intakes estimated by subtract fecal and urinary energy loss was 2467kcal for the male subjects and 1897kcal for the female subjects. 4) Total body energy change estimated from body composition change over 31 days was decreased 7672kcal for the male subjects and 2689kcal for the female subjects. 5) Mean daily energy expenditure was 2714kcal (45kcal/kg of body weight) for the male subjects and 1984kcal(40kcal/kg of body weight) for the female subjects. 6) The estimated energy expenditure of college-age subjects in this study provide evidence to support the Recommended Dietary Allowances for energy of Korean normal adult.

  • PDF

한국 청소년 여성의 에너지 소비량에 관한 연구 (A Study on Energy Expenditure in Korean Adolescent Women)

  • 김유섭;오승호
    • 한국식품영양과학회지
    • /
    • 제22권4호
    • /
    • pp.367-373
    • /
    • 1993
  • 본 연구는 15~16세의 여자 고등학생 7명을 대상으로 4주간 평상시와 같은 생활양식과 식생활 환경하에서 에너지 섭취량(GE)과 체내 에너지 보류량(BE)의 변동을 측정하므로써 (에너지 평형법) 에너지 소비량을 산출하였다. 에너지 섭취량과 대변으로의 에너지 손실량(FE)은 열량계로 측정하였고 소변으로의 에너지 손실량 (UE)은 질소 배설량으로부터 환산하였다. 체내 지방조직량 (FM)은 피부두께를 측정하여 산출한 신체 밀도법에 의하였다. 총 에너지 섭취량에 대한 당질, 단백질 및 지방질의 구성비는 각각 70.1$\pm$1.8%, 12.2$\pm$0.7% 및 17.7$\pm$2.0% 이었다. 총 에너지 섭취량에 대한 대변으로의 에너지 손실율은 2.8%이었다. 대변과 소변으로의 에너지 손실량을 감하여 산출한 1일 1인당 평균 대사에너지량(ME)은 2022 $\pm$50㎉ 이었다. 28일동안의 체성분 변동량으로부터 산출한 체내 총 에너지변동량(BE)은 평균 2400$\pm$950㎉ 가 증가하였다. 1일 1인당 평균 에너지 소비량은 1958$\pm$87㎉로서 체중 kg당 39$\pm$2㎉ 이었다.

  • PDF

농촌 마을회관 제로에너지 건축물 구축을 위한 에너지 성능 분석 연구 - 충남 태안군 정죽4리 마을회관을 중심으로 - (A study on the analysis of energy performance for zero-energy building of rural village hall - Focused on the Jung Juk 4-le village hall -)

  • 박미란;최정만;이정훈
    • 한국농촌건축학회논문집
    • /
    • 제20권4호
    • /
    • pp.1-8
    • /
    • 2018
  • In this study, we survey the 2 buildings at the Central 1 and 8 buildings at the Central 2, which are divided by each climate region in the rural regions. Major heat loss factors are 47% loss of the outer shell including outer wall, roof, and bottom, 30% loss through window, and 23% loss through crevice wind. We analyze the energy simulation of ECO2 program to construct a zero energy building regarding village hall located in Jung Juk 4-le at Centeral 2. We simulate the primary energy requirement regarding village hall and the simulated results show the $265.3kWh/m^2{\cdot}a$ and it may estimate '2' energy efficiency grade. The energy requirement regarding village hall is the $183.2kWh/m^2{\cdot}a$ when the passive technology are applied in village hall. We research total amount of energy requirement in village hall when the passive and active technologies such as solar cell with 3kW and solar thermal with $20m^2$, geothermal power with 17.5kW. The simulated results show the improved energy efficiency certification grade with $1^{{+}{+}{+}}$ due to the reduced primary energy requirement with 73% when passive technology including 3kW of solar panel is applied and the energy independence rate is 54%, which is estimated to be 4th grade of zero energy buildings. The order of energy consumption are solar panel, solar thermal, and geothermal power under applied passive technology in the building. In order to expand the zero energy building, it is necessary to introduce the zero energy evaluation system in the rural region.

과부하 사각형 맨홀의 배수능력 증대에 관한 실험적 연구 (An Experimental Study for Drainage Capacity Increment at Surcharged Square Manholes)

  • 김정수;송주일;윤세의
    • 상하수도학회지
    • /
    • 제22권6호
    • /
    • pp.619-625
    • /
    • 2008
  • Urban sewer systems are designed to operate in open-channel flow regime and energy loss at square manholes is usually not significant. However, the energy loss at surcharged manholes is considered as one of the major causes of inundation in urban area. Therefore, it is necessary to analyze the head loss associated with manholes, especially in surcharged flow. Hydraulic experimental apparatus which can change the manhole inner profile(CASE I, II, III, and IV) and the invert types(CASE A, B, C) were installed for this study. The experimental discharge was $16{\ell}/sec$. As the ratio of b/D(manhole width/inflow pipe diameter) increases, head loss coefficient increases due to strong horizontal swirl motion. The head loss coefficients for CASE I, II, III, and IV were 0.46, 0.38, 0.28 and 0.37, respectively. Side covers increase considerably drainage capacity at surcharged square manhole when the ratio of d/D(side cover diameter/inflow pipe diameter) was 1.0. The head loss coefficients for CASE A, B, and C were 0.45, 0.37, and 0.30, respectively. Accordingly, U-invert is the most effective for energy loss reduction at surcharged square manhole. This head loss coefficients could be available to evaluate the urban sewer system with surcharged flow.