• 제목/요약/키워드: energy loss

검색결과 3,494건 처리시간 0.047초

A Robust Energy Consumption Forecasting Model using ResNet-LSTM with Huber Loss

  • Albelwi, Saleh
    • International Journal of Computer Science & Network Security
    • /
    • 제22권7호
    • /
    • pp.301-307
    • /
    • 2022
  • Energy consumption has grown alongside dramatic population increases. Statistics show that buildings in particular utilize a significant amount of energy, worldwide. Because of this, building energy prediction is crucial to best optimize utilities' energy plans and also create a predictive model for consumers. To improve energy prediction performance, this paper proposes a ResNet-LSTM model that combines residual networks (ResNets) and long short-term memory (LSTM) for energy consumption prediction. ResNets are utilized to extract complex and rich features, while LSTM has the ability to learn temporal correlation; the dense layer is used as a regression to forecast energy consumption. To make our model more robust, we employed Huber loss during the optimization process. Huber loss obtains high efficiency by handling minor errors quadratically. It also takes the absolute error for large errors to increase robustness. This makes our model less sensitive to outlier data. Our proposed system was trained on historical data to forecast energy consumption for different time series. To evaluate our proposed model, we compared our model's performance with several popular machine learning and deep learning methods such as linear regression, neural networks, decision tree, and convolutional neural networks, etc. The results show that our proposed model predicted energy consumption most accurately.

배관 해석 프로그램을 통한 해수담수화 플랜트 수압 시스템 분석 (Analysis of hydraulic system for seawater desalination plant through piping analysis program)

  • 최지혁;최용준;양흥식;이상호;최준석
    • 상하수도학회지
    • /
    • 제34권3호
    • /
    • pp.221-230
    • /
    • 2020
  • In actual seawater desalination plant, the pressure loss due to frictional force of pipe is about 3~5 bar. Also, the pressure loss at pipe connection about 1~3 bar. Therefore, the total pressure loss in the pipe is expected to be about 4~8 bar, which translates into 0.111 to 0.222 kWh/㎥ of energy when converted into the Specific Energy Consumption(SEC). Reducing energy consumption is the most important factor in ensuring the economics of seawater desalination processes, but pressure loss in piping is often not considered in plant design. It is difficult to prevent pressure loss due to friction inside the pipe, but pressure loss at the pipe connection can be reduced by proper pipe design. In this study, seawater desalination plant piping analysis was performed using a commercial network program. The pressure loss and SEC for each case were calculated and compared by seawater desalination plant size.

고속충격을 받는 Carbon/Epoxy 복합재 적층판의 충격체 질량손실을 고려한 흡수에너지 예측 (The Absorbed Energy of Carbon/Epoxy Composite Laminates Subjected to High-velocity impact in Considering the Loss of Projectile Mass)

  • 조현준;김인걸;이석제;김영아;우경식
    • Composites Research
    • /
    • 제26권6호
    • /
    • pp.349-354
    • /
    • 2013
  • 본 논문에서는 Carbon/Epoxy 복합재 적층판에 대하여 실사격 실험을 수행하였으며, 복합재 적층판의 흡수에너지를 예측하기 위한 개선된 방법을 제시하였다. 고속충격실험 과정에서 충격체의 질량손실을 고속카메라를 통하여 거시적으로 확인하였으며, 따라서 이를 고려하여 복합재 적층판의 흡수에너지를 계산하였다. 고속충격을 받는 복합재 적층판의 흡수에너지를 예측하기 위한 모델을 제시하였으며, 복합재 적층판의 흡수에너지는 크게 정적에너지와 동적에너지로 분류하였다. 정적에너지 계산은 섬유의 파손과 정적 탄성에너지와 관련 있는 준정적 관통실험식을 통해 구한 관통에너지를 사용하였다. 동적에너지는 변형되는 시편의 운동에너지와 손실된 파편 질량들의 운동에너지로 나뉠 수 있다. 최종적으로 충격체 질량손실을 고려하여 예측된 흡수에너지와 실험결과를 비교/분석하였다.

A simple formula for insertion loss prediction of large acoustical enclosures using statistical energy analysis method

  • Kim, Hyun-Sil;Kim, Jae-Seung;Lee, Seong-Hyun;Seo, Yun-Ho
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제6권4호
    • /
    • pp.894-903
    • /
    • 2014
  • Insertion loss prediction of large acoustical enclosures using Statistical Energy Analysis (SEA) method is presented. The SEA model consists of three elements: sound field inside the enclosure, vibration energy of the enclosure panel, and sound field outside the enclosure. It is assumed that the space surrounding the enclosure is sufficiently large so that there is no energy flow from the outside to the wall panel or to air cavity inside the enclosure. The comparison of the predicted insertion loss to the measured data for typical large acoustical enclosures shows good agreements. It is found that if the critical frequency of the wall panel falls above the frequency region of interest, insertion loss is dominated by the sound transmission loss of the wall panel and averaged sound absorption coefficient inside the enclosure. However, if the critical frequency of the wall panel falls into the frequency region of interest, acoustic power from the sound radiation by the wall panel must be added to the acoustic power from transmission through the panel.

Quadrant Analysis in Correlation between Mechanical and Electrical Properties of Low-Temperature Conductive Film Bonded Crystalline Silicon Solar Cells

  • Baek, Su-Wung;Choi, Kwang-Il;Lee, Woo-Hyoung;Lee, Suk-Ho;Cheon, Chan-Hyuk;Hong, Seung-Min;Lee, Kil-Song;Shin, Hyun-Woo;Yan, Yeon-Won;Lim, Cheolhyun
    • Current Photovoltaic Research
    • /
    • 제3권1호
    • /
    • pp.1-4
    • /
    • 2015
  • In this study, we analyzed the correlation between mechanical and electrical properties of low-temperature conductive film (LT-CF) bonded silicon solar cells by a quadrant analysis (horizontal axis (peeling strength), vertical axis (power loss)). We found that a series of points with various bonding parameters such as bonding temperature, pressure and time were distributed in the different three regimes; weak regime (Q2: weak bonding strength and high power loss), moderate regime (Q4 : strong bonding strength and low power loss) and hard regime (Q3 : weak bonding strength and low power loss). Using this analogous technique, it was possible to fabricate the LT-CF bonded silicon solar cells with the various conditions displayed in Q3 of the quadrant plots, possessing the peeling strength of ~ 1N/mm and power loss of 2~3%.

통계적 에너지 해석법을 이용한 소형 잔향실의 연성손실계수 측정 (Calculation of Coupling Loss Factor for Small reverberation cabin using Statistical Energy Analysis)

  • 김관주;김운경;윤태중;김정태
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.797-801
    • /
    • 2003
  • The Statistical Energy Analysis is based on the power flow and the energy conservation between sub-systems, which enable the prediction of acoustic and structural vibration behavior in mid-high frequency ranges. This paper discusses the identification of SEA coupling loss factor parameters from experimental measurements of small reverberation chamber sound pressure levels and structural accelerations. As structural subsystems, steel plates with and without damping treatment are considered. Calculated CLFs were verified by both transmission loss values for air-borne CLF case and running SEA commercial software As a result, CLFs have shown a good agreement with those computed by software. Acoustical behavior of air-borne noise and structure-borne noise has been examined. which shows reasonable results, too.

  • PDF

Clinical Determinants of Weight Loss in Patients with Esophageal Carcinoma During Radiotherapy: a Prospective Longitudinal View

  • Jiang, Nan;Zhao, Jin-Zhi;Chen, Xiao-Cen;Li, Li-Ya;Zhang, Li-Juan;Zhao, Yue
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권5호
    • /
    • pp.1943-1948
    • /
    • 2014
  • Purpose: The prevalence of weight loss in esophageal carcinoma patients is high and associated with impairment of physical function, increased psychological distress and low quality of life. It is not known which factors may contribute to weight loss in patients with esophageal carcinoma during radiotherapy in China. The objective of this study was to identify the associated demographic and clinical factors influencing weight loss. Methods: We evaluated 159 esophageal carcinoma patients between August 2010 and August 2013 in a crosssectional, descriptive study. Patient characteristics, tumor and treatment details, psychological status, adverse effects, and dietary intake were evaluated at baseline and during radiotherapy. A multivariate logistic regression analyss was performed to identify the potential factors leading to weight loss. Results: 64 (40.3%) patients had weight loss ${\geq}5%$ during radiotherapy. According to logistic regression analysis, depression, esophagitis, and loss of appetite were adverse factors linked to weight loss. Dietary counseling, early stage disease and total energy intake ${\geq}1441.3$ (kcal/d) were protective factors. Conclusions It was found that dietary counseling, TNM stage, total energy intake, depression, esophagitis, and loss of appetite were the most important factors for weight loss. The results underline the importance of maintaining energy intake and providing dietary advice in EC patients during RT. At the same time, by identifying associated factors, medical staff can provide appropriate medical care to reduce weight loss. Further studies should determine the effect of these factors on weight loss and propose a predictive model.

패시브 디자인을 적용한 ICF공법 주택의 난방에너지 성능 분석 (An Analysis of Heating Energy Performance in Housings of ICF Method with Passive Design Applied)

  • 김준희;이태구
    • KIEAE Journal
    • /
    • 제13권3호
    • /
    • pp.33-40
    • /
    • 2013
  • The world population is consuming more than 1/3 of the total energy for heating housings. Particularly in our country, 21% of the consumption energy is occupied by building section. Therefore, it is necessary to increase the energy efficiency in buildings, thus promoting a comfortable residential environment while minimizing energy consumption. Accordingly, this study presents considerations for implementing high-insulated and airtight passive houses. This study selected four houses with passive house design applied, performed building energy performance through PHPP2007, a German passive house design simulation program, and compared the building-specific heat loss and heat gain. As a result, the most vulnerable part to heat loss was turned out to be a window and the heat loss was caused by outer wall, roof, and ventilation. Accordingly, for the implementation of passive house, it is necessary to make a careful plan and airtight construction that are complementary to various parts through the energy performance analysis started from the design phase.

압전 지능 구조물을 이용한 통계적 에너지 해석 기법 (Application of Piezoelectric Smart Structures for Statistical Energy Analysis)

  • 김재환;김정하;김재도
    • 소음진동
    • /
    • 제11권2호
    • /
    • pp.257-264
    • /
    • 2001
  • In this research, piezoelectric smart structures are applied for SEA(Statistical Energy Analysis), which is well known approach for high frequency analysis. A new input power measurement based on piezoelectric electrical power measurement is proposed and compared with the conventional method in SEA. As an example, a simple aluminum beam on which piezoelectric actuator is attached is considered. By measuring the electrical impedance and electrical current of the piezoelectric actuator, the electrical power given on the actuator is found and this is In turn converted into the mechanical energy. From the measured value of the stored energy of the beam, the Internal loss factor is calculated and this value shows a good agreement with that given by the conventional method as well as the theoretical value. To compare the coupling loss factor, L-shape beam system which consists of a aluminum beam subsystem and a steel beam subsystem coupled by three pin is taken as second example. The input power and stored energy of each subsystem are found by the proposed approach. The coupling loss factor found by the electrical input power obtained from the piezoelectric actuator exhibits similar trend to the value found by the conventional method as well as the theoretical value. In conclusion, the use of SEA for high frequency application of piezoelectric smart structures is Possible. Especially, the input power that is essential for SEA can be found accurately by measuring the electrical input power of the piezoelectric actuator.

  • PDF

Development of On-site Heat Loss Audit and Energy Consulting System for Greenhouse

  • Kwon, Jin Kyung;Kang, Geum Choon;Lee, Seong Hyun;Sung, Je Hoon;Yun, Nam Kyu;Moon, Jong Pil;Lee, Su Jang
    • Journal of Biosystems Engineering
    • /
    • 제38권4호
    • /
    • pp.287-294
    • /
    • 2013
  • Purpose: Greenhouses for a protected horticulture covered with a plastic or glass are easy to have weakness in a heat loss by deterioration, damage, poor construction, and so on. To grasp the vulnerable points of heat loss of the greenhouses is important for heating energy saving. In this study, an on-site heat loss audit and energy consulting system were developed for an efficient energy usage of a greenhouse. Method: Developed system was mounted with infrared thermal and visual cameras to grasp the heat loss from the greenhouse quickly and exactly, and a trial calculation program of heating load of greenhouse to provide farmers with the information of heating energy usage. Results: Developed system could print out the reports about the locations and causes of the heat losses and improvement methods made up by an operator. The mounted trial calculation program could print out the information of the period heating load and fuel cost according to the conditions of greenhouse and cultivation. The program also mounted the databases of the information on the 13 horticultural energy saving technologies developed by the Korea Rural Development Administration and simple economic analysis sub-program to predict the payback period of the technologies. Conclusion: The developed system was expected to be used as the basic equipment for an instructors of district Agricultural Technology and Extension Centers to conduct the energy consulting service for the farmers within the jurisdiction.