• Title/Summary/Keyword: energy input-output analysis

Search Result 247, Processing Time 0.027 seconds

Analysis on The Production Costs and Energy Balance of Heating Wood-Chip by Yarding Machines (집재기계에 따른 난방용 목재칩의 생산비용 및 에너지 수지분석)

  • Hwang, Jin-Sung;Oh, Jae-Heun;Kim, Joon-Soon;Cha, Du-Song
    • Journal of Korean Society of Forest Science
    • /
    • v.98 no.6
    • /
    • pp.799-805
    • /
    • 2009
  • To construct the production system of forest biomass as a small scale heating energy source, energy availability of wood-chip was examined by cost and energy balance analysis in the production process. The costs to produce wood-chip of 1 kg was calculated by yarding machines and their operational gradient conditions. As a result, 195.45~210.54 won/kg were required as production costs of wood-chip. Input energy rate (%) which is output to input energy in wood-chip production process were showed as 26.58~27.38%. Energy input rate by operational gradient was not significantly difference, and scenario B with tower yarder system appeared by more efficient than scenario A with tractor yarding system in opposition to production costs analysis.

The Effects of Wind Power Generation Exports on the National Economy (풍력발전 해외수출의 경제적 파급효과 분석)

  • Jin, Se-Jun;Jeong, Dong-Won;Kwon, Yong-O;Yoo, Seung-Hoon
    • Journal of Energy Engineering
    • /
    • v.21 no.3
    • /
    • pp.281-291
    • /
    • 2012
  • Recently, global economy has recovered and aspects of the renewable energy industry in the global competition is more fierce, the new growth engines of the major countries, including the United States and China, industry promotion policy as being deployed. Major advanced countries and Korea also invested a lot of money to wind power development as a part of renewable energy development and promoting the construction of wind power generation. The global wind power generation market is expected to further increase the scale to about 70 billion US dollars, thus, Korea as well as the installation of domestic wind power overseas actively considering. This study uses input-output analysis to estimate the role of wind power generation sector exports national economy. More specifically, this study shows what national economy effect of production-inducing effect, value-added inducing effect, and employment-inducing effect are explored with demand-driven moel. After define wind power generation sector what small sized of Input-Output table 168 sectors among 11 sectors, this study pays particular and close attention to wind power generation sector by taking the sector as exogenous specification and then investigating economic impacts of it. The wind power generation exportation case of overseas 100 billion won, production-inducing effect, value-added inducing effect, and employment-inducing effect are 205 billion won, 68 billion won and 1,054 persons, respectively. These quantitative information can be usefully utilized in the policy-making for the industrialization of wind power generation exports.

CO2 Emission Structure Analysis of Industrial Sector with Environmental Input-Output Table 2005 (환경산업연관표 2005를 이용한 산업부문의 이산화탄소(CO2) 배출 분석)

  • Kim, Yoon Kyung
    • Environmental and Resource Economics Review
    • /
    • v.20 no.1
    • /
    • pp.1-31
    • /
    • 2011
  • By employing Environmental Input-Output Table 2005, which has 76 intermediate sector and 21 energy sources, this paper analyses the flow of energy demand and $CO_2$ after estimating an induced $CO_2$ emissions from 76 industrial sectors. Index of $CO_2$ intensity($CO_2/GDP$) and other index of $CO_2$ intensity($CO_2/calory$) showed that final demand sector uses more high calory energy source. Intermediate sector used less environmental friendly energy source and emit more $CO_2$ at same calory. Industries those has high induced $CO_2$ emissions are Thermal Power($32.587CO_2-g/Won$), Cement($10.370CO_2-g/Won$), Road Transportation($7.255CO_2-g/Won$), Cokes and Other Coal Products($5.791CO_2-g/Won$), Steam and Hot water supply, Sewage, Sanitary services($4.575CO_2-g/Won$). It is shown that industry such as Iron and Steel which has low $CO_2$ intensity, high backward linkage effect and high forward linkage effect makes high induced $CO_2$ emissions. Environmental load and $CO_2$ emissions in overall economy will decrease when not high $CO_2$ intensity industry but also low $CO_2$ intensity industry makes lower $CO_2$ intensity.

  • PDF

Development of MARS Transient Analyzer

  • Hwang, M.K.;Kim, K.D.;Jeong, J.-J.;Lee, Y.J.;Chung, B.D.
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 2002.10a
    • /
    • pp.155.2-155
    • /
    • 2002
  • A visual environment for system analysis codes (hereinafter called "ViSA") has been developed to support code users in their input preparations, code executions, and output interpretations. ViSA provides a more convenient way for base input data generation and modification on a user-friendly basis. It also provides on-line graphical displays to give an in-depth understanding of transient thermal-hydraulic behaviors in nuclear power plants. This paper presents the main features of ViSA.

  • PDF

Output Voltage Ripple Analysis and Design Considerations of Intrinsic Safety Flyback Converter Based on Energy Transmission Modes

  • Hu, Wei;Zhang, Fangying;Xu, Yawu;Chen, Xinbing
    • Journal of Power Electronics
    • /
    • v.14 no.5
    • /
    • pp.908-917
    • /
    • 2014
  • For the purpose of designing an intrinsic safety Flyback converter with minimal output voltage ripple based on a specified output current, this paper first classified the energy transmission modes of the system into three sorts, namely, the Complete Inductor Supply Mode-CCM (CISM-CCM), the Incomplete Inductor Supply Mode-CCM (IISM-CCM) and the Incomplete Inductor Supply Mode-DCM (IISM-DCM). Then, the critical secondary self-inductance assorting the three modes are deduced and expressions of the output voltage ripples (OVR) are presented. For a Flyback converter with constant loads and switching frequency, it is shown that the output voltage ripple in the CISM-CCM is the smallest and that it has no relationship with the secondary self-inductance. Otherwise, the OVR of the other two modes are bigger than the previously mentioned one. It is concluded that the critical inductance between the CISM-CCM and the IISM-CCM is the minimal secondary self-inductance to ensure the smallest output voltage ripple. At last, a design method to guarantee the minimum OVR within the scales of the input voltage and load are analyzed, and the minimum secondary self-inductance is proposed to minimize the OVR. Simulations and experiments are given to verify the results.

Classification of Clusters and Analysis of R&D Portfolio in Korean Industry (한국산업의 클러스터 분류 및 클러스터간 연구개발 포트폴리오 분석)

  • 박종용;신준석;박광만;김석현;박용태
    • Proceedings of the Technology Innovation Conference
    • /
    • 2002.06a
    • /
    • pp.238-256
    • /
    • 2002
  • Competitiveness of a nation can be explained by the concept of national innovation systems(NIS). As components of NIS, industry clusters become the issue in analysing innovative activity of an economy. Innovative clusters can be identified by the innovation survey or other economic activity data. Input-output Table was used widely as a tool for quantitative analysis, This paper classifies seven clusters in Korean industry based on inter-industries trade of intermediary goods and services, Maximizing procedure method is used in analysing input-output table. Identified clusters are Textiles/chemicals, Construction/Material, Instrument/Equipment, Automobile, Services, Energy, and Agriculture/Food cluster, Among these clusters, some different characteristics in R&D portfolios are detected. R&D investment characteristics of each cluster give us significant implications in understanding innovative dynamics of Korean industry.

  • PDF

Analysis for the Operating Characteristics when the Induction Motor is Used as a Generator (유도전동기를 발전기로 사용시 동작 특성 해석)

  • Kim, Jong-Gyeum
    • New & Renewable Energy
    • /
    • v.10 no.2
    • /
    • pp.5-11
    • /
    • 2014
  • Squirrel cage induction motor is the main driving system of industrial field and familiar with its use in a large variety of applications. The structure and operating characteristics of induction generator is almost identical to induction motor, but the induction generator part is used restrictively from hydropower power and wind power development etc. Recently induction generator is commonly used for micro & small hydro power applications due to its simplicity, reliability, low cost and robustness. Input and output of induction motor has turned against at the induction generator operation. Rotation speed of induction generator is small faster than synchronous speed of induction motor. As output of induction machines increases with the increasement of speed, so loss is same. Actually, generator efficiency is lower than motor at this condition. If induction generator is connected with mechanical load such as increaser, total efficiency is decreased. Consequently the quality in compliance with an induction motor parameter applying like that in the generator is a possibility of having the error of some. In this paper, we analyzed that input, output, torque and efficiency of induction machine is different from each other above and below synchronous speed.

Design and analyses of vibration driven energy harvester for low frequency (저주파수용 진동형 에너지 하베스터의 최적 설계 및 해석)

  • Ryu, Kyeong-Il;Chung, Gwiy-Sang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.238-238
    • /
    • 2010
  • This paper describes the design and analysis of vibration driven energy harvester for low frequency. The maximum output powers at load were $124.2{\sim}132.2\;{\mu}W$ with magnets during 3 mm input displacement at 6 Hz resonant frequency of system.

  • PDF

A Comparative Analysis on the Economic Effects of the City Gas Industry Between Korea and Japan (한·일 도시가스산업의 경제적 파급효과 비교분석)

  • Hong, Sa-Do-Ah;Woo, Hee-Jin;Kang, Ji-Eun;Kim, Joo-Ho;Park, Jung-Gu
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.6
    • /
    • pp.102-114
    • /
    • 2016
  • Due to the Paris Agreement, city gas is drawing attention as an alternative energy source to reduce greenhouse gases. This study conducts a comparative analysis on the economic effects of city gas between Korea and Japan, using input-output(I-O) tables from the Bank of Korea and from Japan's Ministry of Economy, Trade and Industry. The results show that production-inducing, value-added-inducing and employment-inducing effects of Korea's city gas were greater than those in Japan. But supply-shortage and price-pervasive effects of Korea's city gas were also greater than those in Japan. According to these results, production-inducing, value-added-inducing and employment-inducing effects should be sustained, and the policies vitalizing stabilizing supply-shortage and price-change effects, on the other hand, are recommended.