• Title/Summary/Keyword: energy decay rate

Search Result 88, Processing Time 0.025 seconds

Applying methane and carbon flow balances for determination of first-order landfill gas model parameters

  • Park, Jin-Kyu;Chong, Yong-Gil;Tameda, Kazuo;Lee, Nam-Hoon
    • Environmental Engineering Research
    • /
    • v.25 no.3
    • /
    • pp.374-383
    • /
    • 2020
  • Landfill gas (LFG) emissions from a given amount of landfill waste depend on the carbon flows in the waste. The objective of this study was to more accurately estimate the first-order decay parameters through methane (CH4) and carbon flow balances based on the analysis of a full-scale landfill with long-term data and detailed field records on LFG and leachate. The carbon storage factor for the case-study landfill was 0.055 g-degradable organic carbon (DOC) stored per g-wet waste and the amounts of DOC lost with the leachate were less than 1.3%. The appropriate CH4 generation rate constant (k) for bulk waste was 0.24 y-1. The the CH4 generation potential (L0) values ranged 33.7-46.7 m3-CH4 Mg-1, based on the fraction of DOC that can decompose (DOCf) value of 0.40. Results show that CH4 and carbon flow balance methods can be used to estimate model parameters appropriately and to predict long-term carbon emissions from landfills.

A Review on Nuclear Magnetic Resonance Logging: Simulation Schemes (자기공명반응 시뮬레이션 해설 및 비교)

  • Jang, Jae Hwa;Nam, Myung Jin
    • Geophysics and Geophysical Exploration
    • /
    • v.16 no.2
    • /
    • pp.97-105
    • /
    • 2013
  • Nuclear magnetic resonance (NMR) logging has become an important technique for formation evaluation, detecting interaction signals between H protons and applied magnetic fields. Measured decay signals called relaxation, contain important information about density of H protons and different decay rate due to its fluid type in the sensitive area. Thus, petrophysical information such as porosity, permeability and wettability can be estimated through the interpretation of the decay signals. Many researches on random walk simulation have been published, since a simulation method based on random walk for solving exponential decays was adapted in the early of 1950. This study first makes a review on NMR simulation researches, explains two most important methods: simulation with or without considering magnetic field gradient. Lastly, the study makes a comparison between NMR simulation responses with and without magnetic field gradient to show the importance to consider magnetic gradient to analyze the effects of magnetic gradients on NMR responses.

PHYSICAL PROPERTIES OF VAR10US BRANDS OF ELASTOMERIC CHAINS (수종의 합성 고무탄성재의 성질에 관한 연구)

  • Kim, Kyung-Ho;Hwang, Chung-Ju;Sung, Sang-Jin
    • The korean journal of orthodontics
    • /
    • v.27 no.6 s.65
    • /
    • pp.943-954
    • /
    • 1997
  • Forces needed for orthodontic tooth movement are obtained from various appliances such as orthodontic wires or elastic rubber. Orthodontic elastic rubber is widely used clinically, but permanent deformation and force decay may occur from the environmental changes, time of clinical use and the extent of the stretch, making the Prediction of force being applied difficult. The Present study examined and compared the changes in residual force between three brands of elastomeric chains (Ormco Generation II Power Chains ; brand A, RMO : Energy-Chain ; brand B, Unitek : AlastiK ; brand C) under various environmental conditions, amount of initial force, types of elastomer and the rate of extension. The characteristic physical properies of the elastomeric chains were as follows. 1. In all three brands, the residual force ratio was largest when the chains were stored in air, with no difference between water and saliva. 2. In all three brands, after 24 hours, there was no statistical difference in residual force ratio according to the initial force level. 3. In Brand A and B, the presence of filament had no correlation with the residual force ratio. In Brand C force decay was more severe when the chain contained filament. 4. In each brand, rate of extension had no effect on residual force ratio. 5. Brand B showed relatively higher residual force ratio compared to other brands.

  • PDF

Critical Role of Glu175 on Stability and Folding of Bacterial Luciferase: Stopped-flow Fluorescence Study

  • Shirazy, Najmeh Hadizadeh;Ranjbar, Bijan;Hosseinkhani, Saman;Khalifeh, Khosrow;Madvar, Ali Riahi;Naderi-Manesh, Hossein
    • BMB Reports
    • /
    • v.40 no.4
    • /
    • pp.453-458
    • /
    • 2007
  • Bacterial luciferase is a heterodimeric enzyme, which catalyzes the light emission reaction, utilizing reduced FMN (FMNH2), a long chain aliphatic aldehyde and $O_2$, to produce green-blue light. This enzyme can be readily classed as slow or fast decay based on their rate of luminescence decay in a single turnover. Mutation of Glu175 in $\alpha$ subunit to Gly converted slow decay Xenorhabdus Luminescence luciferase to fast decay one. The following studies revealed that changing the luciferase flexibility and lake of Glu-flavin interactions are responsible for the unusual kinetic properties of mutant enzyme. Optical and thermodynamics studies have caused a decrease in free energy and anisotropy of mutant enzyme. Moreover, the role of Glu175 in transition state of folding pathway by use of stopped-flow fluorescence technique has been studied which suggesting that Glu175 is not involved in transition state of folding and appears as surface residue of the nucleus or as a member of one of a few alternative folding nuclei. These results suggest that mutation of Glu175 to Gly extended the structure of Xenorhabdus Luminescence luciferase, locally.

Evaluation of Disinfection Characteristics for Mixed Oxidants Produced by Electro-chemical Method (전기분해 방식에 의한 혼합산화제 소독 특성 평가)

  • Lee, Kyung-Hyuk;Lim, Jae-Lim;Lee, Doo-Jin;Kim, Seong-Su;Ahn, Hyo-Won
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.5
    • /
    • pp.625-631
    • /
    • 2005
  • Disinfection characteristics of mixed oxidants produced by mean of electro-chemical method were evaluated. Inactivation rate of B. subtilis spore on the mixed oxidants were similar with that of chlorine. Based on the experimental results, activation energy of mixed oxidants and chlorine with B. subtilis spore at pH 8.3 were calculated as 30.8, $34.7kJ{\cdot}mol^{-1}$ respectively. UV absorption spectrum of both chlorine and mixed oxidants present similar. Molar extinction coefficients of chlorine and mixed oxidants at 292nm, which is maximum absorption wavelength of $OCl^-$ were 357, $377M^{-1}cm^{-1}$, respectively. Disinfectant decay rate and formation rate of THM in the S WTP filtrate also shows insignificant difference for both mixed oxidants and chlorine. In consequent, it was confirmed that high portion of chlorine presents in the mixed oxidants.

Thermal-Hydraulic Analysis and Parametric Study on the Spent Fuel Pool Storage (기사용 핵연료 저장조에 대한 열수력 해석 및 관련 인자의 영향 평가)

  • Lee, Kye-Bock;Nam, Ki-Il;Park, Jong-Ryul;Lee, Sang-Keun
    • Nuclear Engineering and Technology
    • /
    • v.26 no.1
    • /
    • pp.19-31
    • /
    • 1994
  • The objective of this study is to conduct a thermal-hydraulic analysis on the spent fuel pool and to evaluate a parametric effect for the thermal-hydraulic analysis of spent fuel pool. The selected parameters are the Reynolds Number and the gap flow through the oater gap between fuel cell and fuel bundle. The simplified flow network for a path of fuel cells is used to analyze the natural circulation phenomenon. In the flow network analysis, the pressure drop for each assembly from the entrance of the fuel rack to the exit of the fuel assembly is balanced by the driving head due to the density difference between the pool fluid and the average fluid in each spent fuel assembly. The governing equations ore developed using this relation. But, since the parameters(flow rate, pressure loss coefficient, decay heat, density)are coupled each other, iteration method is used to obtain the solution. For the analysis of the YGN 3&4 spent fuel rack, 12 channels are considered and the inputs such as decay heat and pressure loss coefficient are determined conservatively. The results show the thermal-hydraulic characteristics(void fraction, density, boiling height)of the YGN 3&4 spent fuel rack. There occurs small amount of boiling in the cells. Fuel cladding temperature is lower than 343.3$^{\circ}C$. The evaluation of parametric effect indicates that flow resistances by geometric effect are very sensitive to Reynolds number in the transition region and the gap flow is negligible because of the larger flow resistance in the gap flow path than in the fuel bundle.

  • PDF

An experimental study on thermal storage characteristics in the thermally stratified water storage system (성층 축열 시스템에서의 열 저장 특성에 관한 실험적 연구)

  • Koh, J.Y.;Kim, Y.K.;Lee, C.M.;Yim, C.S.
    • Journal of the Korean Solar Energy Society
    • /
    • v.21 no.4
    • /
    • pp.37-46
    • /
    • 2001
  • This study describes the experimental study that focuses on the effects that distributor shapes and flow rate variations have an influence on the stratification in a rectangular thermal storage tank. Experiments were carried out under the conditions that the flow rates of working fluid are 20, 10 and $5\ell$/min. The storage tank is initially filled with chilled water of $1^{\circ}C$, and is extracted through the bottom at the same rate as the return warm water from load is entered through the distributor at the top of the tank. The thermo-cline forms at the top of the storage tank as the warm water enters the tank from the load through the distributor and the thermo-cline thickness increases with time. Emphasis is given to the effects of mixing at the inlet that increases the thermo-cline decay Flow rate variation and inlet distributor shapes are the important parameters in deciding the performance of a storage system. Stratification degree increases with decreasing in inlet flow rate under $10\ell$/min. Experiments shows that better thermal stratification can be obtain using the distributor to limit momentum mixing at the inlets and outlets. Also, 12% of improvement in the thermal energy usage has been achieved using the modified distributor discharging same flow rate in each lateral ports.

  • PDF

Slab Thickness Calculations on Hot Cell

  • Ha, Yung-Joon;Kim, Seong-Yun;Kim, Dong-Hoon
    • Nuclear Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.26-36
    • /
    • 1978
  • Numerical computations of radioactivities and decay energies in a spent fuel have been carried out for designing of a hot cell. Optimum wall and window thicknesses that can preserve spent fuel rods for experimental purposes are estimated with burnup rate of 33,000 MWD/T(U) which is nearly maximum from a pressurized water reactor such as the Go-Ri Unit 1. Before putting the spent fuels into a hot cell, it is assumed for thickness estimates of shield materials that they are cooled in a storage tay for several lime intervals. Considered are various types of shield materials through which changing the distances from a source to an observation point is also made.

  • PDF

Evaluation of Occupational, Facility and Environmental Radiological Data From the Centralized Radioactive Waste Management Facility in Accra, Ghana

  • Gustav Gbeddy;Yaw Adjei-Kyereme;Eric T. Glover;Eric Akortia;Paul Essel;Abdallah M.A. Dawood;Evans Ameho;Emmanuel Aberikae
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.21 no.3
    • /
    • pp.371-381
    • /
    • 2023
  • Evaluating the effectiveness of the radiation protection measures deployed at the Centralized Radioactive Waste Management Facility in Ghana is pivotal to guaranteeing the safety of personnel, public and the environment, thus the need for this study. RadiagemTM 2000 was used in measuring the dose rate of the facility whilst the personal radiation exposure of the personnel from 2011 to 2022 was measured from the thermoluminescent dosimeter badges using Harshaw 6600 Plus Automated TLD Reader. The decay store containing scrap metals from dismantled disused sealed radioactive sources (DSRS), and low-level wastes measured the highest dose rate of 1.06 ± 0.92 µSv·h-1. The range of the mean annual average personnel dose equivalent is 0.41-2.07 mSv. The annual effective doses are below the ICRP limit of 20 mSv. From the multivariate principal component analysis biplot, all the personal dose equivalent formed a cluster, and the cluster is mostly influenced by the radiological data from the outer wall surface of the facility where no DSRS are stored. The personal dose equivalents are not primarily due to the radiation exposures of staff during operations with DSRS at the facility but can be attributed to environmental radiation, thus the current radiation protection measures at the Facility can be deemed as effective.

Reduction Characteristics of Oxygen Carriers in a Pressurized Bubbling Fluidized Bed (가압 기포유동층에서 산소전달입자들의 환원반응특성)

  • YOON, JOO-YOUNG;BAE, DAL-HEE;BAEK, JEOM-IN;RYU, HO-JUNG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.27 no.5
    • /
    • pp.589-596
    • /
    • 2016
  • Effects of pressure, temperature, gas velocity, and fuel flow rate on reduction of three oxygen carriers, SDN70, OC-1, OC-2, were measured and investigated in a pressurized bubbling fluidized bed reactor. Among three oxygen carriers OC-2 was selected as the best oxygen carrier in view of fuel conversion and $CO_2$ selectivity. However, all oxygen carriers showed good reactivity even at high pressure conditions. SDN70 particle showed maximum reactivity at $900^{\circ}C$ and low reactivity at $950^{\circ}C$. However, reactivity decay of OC-1 and OC-2 particles at high temperature condition was negligible. The fuel conversion and the $CO_2$ selectivity slightly decreased as the gas velocity increased, whereas they are slightly increased as the fuel concentration increased.