Abstract

Forces needed for orthodontic tooth movement are obtained from various appliances such as orthodontic wires or elastic rubber. Orthodontic elastic rubber is widely used clinically, but permanent deformation and force decay may occur from the environmental changes, time of clinical use and the extent of the stretch, making the Prediction of force being applied difficult. The Present study examined and compared the changes in residual force between three brands of elastomeric chains (Ormco Generation II Power Chains ; brand A, RMO : Energy-Chain ; brand B, Unitek : AlastiK ; brand C) under various environmental conditions, amount of initial force, types of elastomer and the rate of extension. The characteristic physical properies of the elastomeric chains were as follows. 1. In all three brands, the residual force ratio was largest when the chains were stored in air, with no difference between water and saliva. 2. In all three brands, after 24 hours, there was no statistical difference in residual force ratio according to the initial force level. 3. In Brand A and B, the presence of filament had no correlation with the residual force ratio. In Brand C force decay was more severe when the chain contained filament. 4. In each brand, rate of extension had no effect on residual force ratio. 5. Brand B showed relatively higher residual force ratio compared to other brands.

교정적인 치아이동에 필요한 힘들은 orthodontic wire나 여러 가지 elastic rubber등으로 얻을 수 있다. 이중 교정용 elastic rubber는 환경 변화, 시간 경과, 신장(stretch) 정도에 따라 영구 변형과 힘의 소실(force decay)이 다양하게 나타나므로 적용된 힘을 예측하기 힘든 단점이 있다. 본 연구에서는 임상에서 널리 사용되는 3가지 종류 (Ormco : Generation II Power Chains ; brand A, RMO : Energy-Chain ; brand B, Unitek : AlastiK ; brand C)의 교정용 합성고무탄성재를 실험 환경, 초기 힘의 크기, 고무탄성재의 형태 그리고 신장속도를 달리한 뒤 시간에 따른 잔존 힘의 변화를 비교하였으며, 종류에 따른 특징적인 물리적 성질에 대하여 다음과 같은 결론을 얻었다. 1. 세 종류 모두에서 상온의 공기에 보관된 경우 잔존 힘의 비율이 가장 컸으며 물과 타액 간에는 차이가 없었다. 2. 세 종류 모두에서 24시간 이후로는 초기 힘의 크기에 따른 잔존 힘의 비율에 차이가 없었다. 3. A, B는 filament 유무에 따른 잔존 힘의 비율에 차이가 없었으나 C에서는 filament가 있는 경우 힘의 소실이 더 많았다. 4. 신장속도를 달리하여도 잔존 힘의 비율에는 큰 차이가 없었다. 5. B는 각각의 실험조건에서 A, C보다 상대적으로 잔존 힘의 비율이 높았다.

Keywords