• Title/Summary/Keyword: energy company

Search Result 814, Processing Time 0.031 seconds

An overview of the prediction methods for roll damping of ships

  • Falzarano, Jeffrey;Somayajula, Abhilash;Seah, Robert
    • Ocean Systems Engineering
    • /
    • v.5 no.2
    • /
    • pp.55-76
    • /
    • 2015
  • Of all the six degrees of freedom, the roll motion of a ship is the most poorly understood and displays complicated phenomena. Due to the low potential wave damping at the natural frequency, the effective analysis of ship roll dynamics comes down to the accurate estimation of the viscous roll damping. This paper provides overview of the importance of roll damping and an extensive literature review of the various viscous roll damping prediction methods applied by researchers over the years. The paper also discusses in detail the current state of the art estimation of viscous roll damping for ship shaped structures. A computer code is developed based on this method and its results are compared with experimental data to demonstrate the accuracy of the method. While some of the key references describing this method are not available in English, some others have been found to contain typographic errors. The objective of this paper is to provide a comprehensive summary of the state of the art method in one place for future reference.

Operating Simulation of RPS using DEVS W/S in Web Service Environment

  • Cho, Kyu-Cheol
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.12
    • /
    • pp.107-114
    • /
    • 2016
  • Web system helps high-performance processing for big-data analysis and practical use to make various information using IT resources. The government have started the RPS system in 2012. The system invigorates the electricity production as using renewable energy equipment. The government operates system gathered big-data with various related information system data and the system users are distributed geographically. The companies have to fulfill the system, are available to purchase the REC to other electricity generation company sellers to procure REC for their duty volumes. The REC market operates single auction methods with users a competitive price. But the price have the large variation with various user trading strategy and sellers situations. This papler proposed RPS system modeling and simulation in web environment that is modeled in geographically distributed computing environment for web user with DEVS W/S. Web simulation system base on web service helps to analysis correlation and variables that act on trading price and volume within RPS big-data and the analysis can be forecast REC price.

Natural Ventilation in High-Rise Building with Double Facades, saving or waste of Energy

  • Lee, Eung-Jik;Pasquay, Till
    • KIEAE Journal
    • /
    • v.2 no.3
    • /
    • pp.39-45
    • /
    • 2002
  • Double facades are built to allow natural ventilation in high rise buildings and buildings with high outside noise level. In high rise Buildings the gains in summer can be reduced by sufficient sun protection devices placed outside the rooms in the ventilated space between the inner and outer facade. To evaluate the energetic performance, three buildings with double facade were monitored for at least one year (Siemens Building in Dortmund/Germany, Victoria Insurance Company in Duesseldorf/Germany and RWE Tower in Essen/Germany). The results document the indoor climate, the boundary conditions for further planning and the possibilities for high rise buildings without or with little cooling facilities.

Development Status of MV Cable with Eco-friendly and High Heat Resistance

  • Jung, Yeon-ha;Lee, Byung-sung;Seo, In-jin;Kwon, Jung-ji;Sohn, Kwang-ik;Kim, Hyung-jun
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.1
    • /
    • pp.55-59
    • /
    • 2016
  • In Europe, polypropylene-insulated HV class cable with high temperature and no cross-linking was commercialized following the MV class. Our company also started a study of the polypropylene-insulated cable in 2013 and was carried out thermal, physical and electrical test. In addition, polypropylene-insulated cable was tested for compatibility with conventional joints and terminations in emergency condition and the accelerated life test for verifying their design life is in progress. The results of this study will be used to establish a standard specification and operation conditions of the polypropylene-insulated cable.

Construction of Expert System for Hazard Assessment of Unconfined Vapor Cloud Explosion (증기운 폭발의 위험성 평가를 위한 전문가 시스템의 구축)

  • 함병호;손민일;김태옥;조지훈;이영순
    • Journal of the Korean Society of Safety
    • /
    • v.10 no.2
    • /
    • pp.97-104
    • /
    • 1995
  • To evaluate readily the effect of unconfined vapor cloud explosion(UVCE) having high possibility of accident and risk in chemical industries, the expert system of UVCE was developed and its applicability on a real accident was analyzed. We found that the hazard of UVCE could be well evaluated from the TNT equivalency model and the empirical loss data produced by overpressure for chemical facilities. By using the developed expert system, the size of vapor cloud, the quantity of vaporization, the released energy, the overpressure range from explosion point, and the impact damage of each installation could be estimated respectively. Also, probable maximum loss and catastrophic loss potential for real accident( cyclohexane release in Flixborough Nypro company) were estimated and compared with damages of the accident. As a result, the developed expert system could be well applicable to real accident.

  • PDF

Power System Simulation in Seoul matropolitain subway Line-6 system (서울 지하철 6호선에 대한 전력계통 시뮬레이션)

  • Lee, Tae-Shik;Moon, Young-Hyun;Sung, Soo-Young;Yoon, Kap-Koo
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.137-139
    • /
    • 1993
  • This paper details methods used to verify the adquacy of a dc traction power supply for design in Seoul matropolitain subway Line-6 system. Examples of the approach are given for a major subway presently under construction. The performance of trains operating at maximum system design capacity is modelled using a train simulation program. Using a dc network analyser program, the maximum train operating timetable, and a model of the ac and dc electrical suppy system, the electrical performance of the entire system can be modelled over a 24-hour period. The results of this analysis are used to determime: train voltage at a level sufficient to ensure train schedules: adequacy of traction transformers, rectifier, and switchgear ratings; sizes of the overhead contact systern conductors, and ac and de feeder cables: and power and energy demands at the utility company's supply points for inital and final timetable operations.

  • PDF

Development of Synchrophasor Data Aquisition and Transmission Systems Using the GPS and the Satellite Network (GPS와 위성통신을 이용한 동기위상 데이터 취득 및 전송장치 개발)

  • Kwon, Dae-Yun;Kim, Ho-Woong;Kim, Dong-Sung;Yoon, Sang-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.598-599
    • /
    • 2007
  • The electricity supply industry for which high stability and quality of power are the primary aim of power company and the first order of business target. As the facilities of generations, transmissions and substations are increased every year, power system becomes more complex and hard to control. The complexity of the power system causes harmful influence on its security and power facilities. Moreover, difficulty of predicting weather condition in these days with its complexity increases the level of uncertainty of energy demand. Wide area online monitoring of power system offers lots of informations and solutions which clear the causes of insecurity in power system. In this paper, we presents the development of synchrophasor data measurement and transmission system using satellite network for power system online monitoring.

  • PDF

The domestic development of 60kw Electron Beam Welding System (고정밀 60kW급 전자빔 용접시스템 국산화 개발)

  • 정원희;엄기원;정인철
    • Proceedings of the KWS Conference
    • /
    • 2001.10a
    • /
    • pp.121-124
    • /
    • 2001
  • The main characteristic of the Electron Beam Welding technique is its high energy density which produces thin and deep welds with very little distortion. High accelerated electrons, focused in a beam of 0.5 ∼ 2mm diameter, produce narrow welds with deep penetration. The result is a small HAZ as well as a low and uniform distortion which is predictible within very narrow limits. But the small diameter of the EB increases the requirements for the equipment control system for centering the beam on the welding joint in order to avoid any lack of fusion. Therefore, in this paper, we introduce the system developed at our company and the quality of welding zone, the detail function of system.

  • PDF

A Investigation on the Present state of Code of Design and Specification for Building Mechanical Engineering (표준시방서 및 설비설계기준의 개정현황에 관한 고찰)

  • Kwon, Yong-Il;Park, Jung-Won;Park, Jong-Il;Kim, Doo-Sung
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.566-571
    • /
    • 2006
  • The purpose of this code is to relate the various controllable factors to the comfort and well-being of the people using the building, so that the requirements of the system may be specified to the designers and the constructor. This study deals with the work involved in design and installation of residential mechanical ventilation. The recommendations made in this code recognize the need to optimize the use of energy, reduce hazards and minimize effects detrimental to the environment. This code was prepared by a committee convened by SAREK. The code provides broad guidance only on certain topics. The titles of standard and code referred to in this code are listed on the reference.

  • PDF

Analysis of Corrosion Behavior of KOFA Zircaloy-4 Cladding

  • Lee, Chan-Bock;Kim, Ki-Hang
    • Nuclear Engineering and Technology
    • /
    • v.30 no.2
    • /
    • pp.173-179
    • /
    • 1998
  • The corrosion behavior of KOFA cladding which is a standard Zircaloy-4 manufactured by Westinghouse Specialty Metal Plant according to the Siemens/KWU's HCW (Highly Cold Worked) standard Zircaloy-4 specification was analyzed using the oxide measurement data of KOFA fuel irradiated in Kori-2 nuclear power plant. Analysis of the measured KOFA cladding oxidation showed that oxidation of KOFA cladding was lower than the design prediction based upon Siemens/KWU's HCW standard Zircaloy-4 cladding. Although the measured fuel rods have relatively low burnup and oxidation and the amount of the measured data are small, analysis of manufacturing and in-reactor operation conditions of KOFA cladding indicates that the differences in the manufacturing processes and chemical composition of the Siemens/KWU's HCW (Highly Cold Worked) standard Zircaloy-4 and KOFA cladding may have somewhat contributed to lower corrosion of KOFA cladding than the expected.

  • PDF