• Title/Summary/Keyword: energy company

Search Result 814, Processing Time 0.026 seconds

The Implementation of Testing Board forSingle Event Upsets

  • Lho, Young-Hwan;Kim, Ki-Yup
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.5 no.2
    • /
    • pp.28-34
    • /
    • 2004
  • One of the major problem encountered in nuclear plants and satellites design isEMI (Electro-Magnetic Interference) and EMC (Electro-Magnetic Compatibility).Here, our focus is to implement the test board for checking SEU (Single EventUpsets); the effects of protons on the electronic system. The SEU results from thelevel change of stored information due to photon radiation and temperature in thespace environment. The impact of SEU on PLD (Programmable Logic Devices)technology is most apparent in ROM/SRAM/DRAM devices wherein the state ofstorage cell can be upset. In this paper, a simple and powerful test techniques issuggested, and the results are presented for the analysis and future reference. In ourexperiment, the proton radiation facilitv (having the energy of 50 MeV with a beamcurrent of 60 uA of cyclotron) available at KIRAMS (Korea Institute of RadiologicalMedical Sciences) has been applied on a commercially available SRAM manufacturedby Hynix Semiconductor Company.

A Study of Flow Characteristics through the Speed Control and Flow Resistance (유로저항에따른 속도제어를 통한 Zone별 유량특성 연구)

  • Oh, Byung-Kil;Kim, Hway-Suh
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.11
    • /
    • pp.762-768
    • /
    • 2011
  • We use floor radiant heating system in the house of commons in winter Floor radiant heating system, which transfer heat by radiation, is one of the energy efficient and comfortable systems that. Floor radiant heating system is configured to be controlled by the room for energy-saving. Proper flow rate to a comfortable heating in the room is important. However, Using a constant speed circulation pump in separate rooms, heating system may cause an imbalance because of the difference of length of coil when operating in the rooms. In this study, our Research team examined heating imbalance due to the variation length through the coil length changes and flow control of the circulation pump.

Smart Power System with Fuzzy Switch and Wind Energy (퍼지 스위치와 풍력 발전을 이용한 스마트 전력 시스템)

  • Ko, Young-Hoon;Sung, Ki-Mun
    • Annual Conference of KIPS
    • /
    • 2016.04a
    • /
    • pp.642-645
    • /
    • 2016
  • 본 논문은 풍력 발전기와 ESS(Energy Storage System)를 효율적으로 연결하는 퍼지 스위치를 제안한다. 최근들어 친환경 전력 시스템의 중요성이 날로 커지고 있다. 친환경 에너지의 대표적인 태양광과 풍력의 경우 지속적인 발전이 불가능하므로 ESS의 사용이 필수적이다. 즉, 발전 가능할 때에 ESS에 충전하고 발전이 어려울 때는 ESS를 방전하는 방식이다. 이러한 스위치는 애매 모호한 구간이 존재하는데 이를 효율적으로 제어하기 위하여 퍼지를 적용하였다. 충전레벨이 낮을 경우 충전하고 충전레벨이 높을 경우 방전하는 것은 기본적인 로직이지만 충전레벨이 중간인 경우 충전이 유리한지 방전이 유리한지 모호해진다. 3단계 충전레벨과 2단계 전력레벨을 입력으로 받아 효율적인 퍼지 스위치를 구성하였다. 또한 효과적인 구현을 위하여 서피스플롯울 참조테이블로 변환하여 사용하였다. 특히, 3단계 충전레벨은 가우시한 함수를 사용하고 2단계 전력레벨은 삼각함수를 사용하여 출력 멤버쉽함수가 보다 잘 반영될 수 있도록 감안하였다.

A Comparative study on the Insulation Performance of the Tilt & Sliding System Window by Actual Survey and Simulation (Tilt & Sliding 시스템창호의 단열성능 실측과 시뮬레이션 비교 분석)

  • Jang, Cheol-Yong;Ahn, Byung-Lip;Kim, Chi-Hoon;Hong, Won-Hwa
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.222-226
    • /
    • 2009
  • The parts of building which has the most influence on thermal load are skins, outer walls and windows. Among them, window is the worst weak point of building even if it has many advantage of solar radiation gain than other parts. The present time, many researches on various performance of window and many types of system-window are being made. This study evaluates thermal performance of tilt & sliding system window by simulation program Therm 5.2 and Window 5.2. After making a sample model improving it's thermal weak point, this study evaluates real thermal performance of system window. As a result, this study understands manufacture ability condition of domestic company and proposes a research plan of system window.

  • PDF

Influence of soil-structure interaction on seismic responses of offshore wind turbine considering earthquake incident angle

  • Sharmin, Faria;Hussan, Mosaruf;Kim, Dookie;Cho, Sung Gook
    • Earthquakes and Structures
    • /
    • v.13 no.1
    • /
    • pp.39-50
    • /
    • 2017
  • Displacement response and corresponding maximum response energy of structures are key parameters to assess the dynamic effect or even more destructive structural damage of the structures. By employing them, this research has compared the structural responses of jacket supported offshore wind turbine (OWT) subjected to seismic excitations apprehending earthquake incidence, when (a) soil-structure interaction (SSI) has been ignored and (b) SSI has been considered. The effect of earthquakes under arbitrary angle of excitation on the OWT has been investigated by means of the energy based wavelet transformation method. Displacement based fragility analysis is then utilized to convey the probability of exceedance of the OWT at different soil site conditions. The results show that the uncertainty arises due to multi-component seismic excitations along with the diminution trend of shear wave velocity of soil and it tends to reduce the efficiency of the OWT to stand against the ground motions.

eXtended Statistical Combination of Uncertainties (XSCU) Method for Digital Nuclear Power Plants

  • In, Wang-Kee;Hwang, Dae-Hyun;Kim, Joon-Sung;Auh, Geun-Sun
    • Nuclear Engineering and Technology
    • /
    • v.30 no.6
    • /
    • pp.617-627
    • /
    • 1998
  • A technically more direct Statistical Combination of Uncertainties (SCU) method, extended SCU (XSCU), was developed to statistically combine the uncertainties associated with the DNBR alarm setpoint and the DNBR trip setpoint of digital nuclear power plants. The Modified SCU (MSCU) method is currently used as the USNRC approved design method to perform the same function. In this study, the MSCU and XSCU methods were compared in terms of the total uncertainties, and the thermal margins to the DNBR alarm and trip setpoints. The MSCU method resulted in small total uncertainties due to large negative biases which are unphysical. The XSCU method gives virtually unbiased total uncertainties which are physically meaningful in order to represent the actual magnitude of the total uncertainties associated with the DNBR alarm and trip setpoints. But the thermal margins to the DNBR alarm and trip setpoints by the MSCU method agree with those by the XSCU method within allowable statistical Variations.

  • PDF

A Study to Take Action for New Chinese Regulations about car Towing Device (토잉 디바이스 중국 신법규 대응 방안)

  • Jin, Jaesun
    • Journal of Applied Reliability
    • /
    • v.17 no.4
    • /
    • pp.362-369
    • /
    • 2017
  • Purpose: Recently, the government of China has established new safety regulations for towing devices. The new Chinese regulation has more unfavorable conditions than the conditions of other countries. So the various measures have been reviewed to satisfy this regulation. Methods: The regulation conditions were compared through analysis of strain energy, and a method for improving the accuracy of analysis is suggested. In addition, the test method considering the tolerance is presented through tolerance analysis. This paper also explained importance of confirming the quality of products through a case of poor quality of Chinese products such as poor heat treatment. Result: We could know how strong Chinese regulations are stronger than other national laws and investigated which member receives a lot of strain energy. In order to cope with these Chinese regulations, we suggested improvement of analysis accuracy, test method through tolerance analysis, and heat treatment quality. Conclusion: This paper contributed to general counterplan of the strengthened new Chinese regulations for towing device.

The practical operating evaluation of the grid connected PV power system (계통연계형 태양광발전시스템의 실증운전 평가)

  • Kim, Eui-Hwan;Ahn, Kyo-Sang;Lim, Hee-Chun
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.5
    • /
    • pp.72-77
    • /
    • 2008
  • The purpose of this paper is to explain the real characteristics of generation system of large scale power system of high voltage the grid connected PV power system for electricity industry. Main system is made up PCS in the class 150kVA. and we studied commercial operation in Korea-Western Power Company,(Tae-An headquarter) with the capacity of module is 122.5 $kW_p$. On the average, power plant utilities' utilization is 12.71 percent and consumption rate is 6.66 percent. We operated normally since 25th, August 2005 without any other problems.

A Study on the Power Generation Using Supercritical Carbon Dioxide (초임계 이산화탄소를 활용한 발전에 대한 연구)

  • NOH, SANGGYUN
    • Journal of Hydrogen and New Energy
    • /
    • v.30 no.4
    • /
    • pp.297-302
    • /
    • 2019
  • In this paper, the power generation efficiency increase has been studied for a Rankine cycle using both supercritical carbon dioxide as a working fluid and LNG as a coolant with PRO/II with PROVISION release 10.0 from Aveva company. Peng-Robinson equation of the state model with Twu's alpha function was selected for the modeling of the power generation cycle using LNG cold heat. Power generation efficiency was increased from 24.82% to 57.76% when using LNG as a coolant for supercritical carbon dioxide power generation cycle.

Comparative Study between Single-stage and Two-stage Expansion Using LNG Cold Heat (액화천연가스 냉열을 이용한 단일팽창과 이단팽창 사이의 비교 연구)

  • NOH, SANGGYUN
    • Journal of Hydrogen and New Energy
    • /
    • v.30 no.2
    • /
    • pp.188-192
    • /
    • 2019
  • Comparative studies between single- and two-stage expansion process using LNG cold heat have been performed for a closed Rankine power generation cycle. PRO/II with PROVISION release 10.0 from Schneider Electric Company was used, and the Peng-Robinson equation of state model with Twu's alpha function was selected for the modeling and optimization of the power generation cycle using LNG cold heat. In two-stage power generation cycle, 6.7% more power was obtained compared to that of single-stage power generation cycle through the optimization works.