• Title/Summary/Keyword: energy assessment

Search Result 2,851, Processing Time 0.033 seconds

Safety Assessment on Long-term Radiological Impact of the Improved KAERI Reference Disposal System (the KRS+)

  • Ju, Heejae;Kim, In-Young;Lee, Youn-Myoung;Kim, Jung-Woo;Hwang, Yongsoo;Choi, Heui-joo;Cho, Dong-Keun
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.spc
    • /
    • pp.75-87
    • /
    • 2020
  • The Korea Atomic Energy Research Institute (KAERI) has developed geological repository systems for the disposal of high-level wastes and spent nuclear fuels (SNFs) in South Korea. The purpose of the most recently developed system, the improved KAERI Reference Disposal System Plus (KRS+), is to dispose of all SNFs in Korea with improved disposal area efficiency. In this paper, a system-level safety assessment model for the KRS+ is presented with long-term assessment results. A system-level model is used to evaluate the overall performance of the disposal system rather than simulating a single component. Because a repository site in Korea has yet to be selected, a conceptual model is used to describe the proposed disposal system. Some uncertain parameters are incorporated into the model for the future site selection process. These parameters include options for a fractured pathway in a geosphere, parameters for radionuclide migration, and repository design dimensions. Two types of SNF, PULS7 from a pressurized water reactor and Canada Deuterium Uranium from a heavy water reactor, were selected as a reference inventory considering the future cumulative stock of SNFs in Korea. The highest peak radiological dose to a representative public was estimated to be 8.19×10-4 mSv·yr-1, primarily from 129I. The proposed KRS+ design is expected to have a high safety margin that is on the order of two times lower than the dose limit criterion of 0.1 mSv·yr-1.

Correction Factor for Assessment of Nearshore Wave Energy (근해 파력에너지 산정을 위한 보정 기법에 관한 연구)

  • Kim, Gunwoo;Jeong, Weon Mu;Jun, Kicheon;Lee, Myung Eun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.164.1-164.1
    • /
    • 2011
  • Previously, many researchers assessed nearshore wave energy in two ways. The first is a simulation with respect to the offshore wave time series to validate the wave buoy data and the wave model results, and the other is to simulate the representative waves of typical seasonal wave conditions. The former requires enormous computational time and effort. The latter yields inspection on the patterns for the spatial and temporal distribution of nearshore wave energy but tends to underestimates the amount of wave energy in the nearshore region owing to the correlation between the significant wave height and wave period. $\ddot{O}$zger et al. (2004) derived the stochastic wave energy formulation by introducing a correction factor explicitly in terms of the covariance of the wave energy and significant wave height. In this study, a correction factor was applied for the assessment of nearshore wave energy obtained by numerical simulation of wave transformation with respect to representative waves.

  • PDF

Optimization Application for Assessment of Total Transfer Capability Using Transient Energy Function in Interconnection Systems (과도에너지 함수를 이용하여 연계계통의 총송전용량 평가를 위한 최적화기법 응용)

  • Kim, Kyu-Ho;Kim, Soo-Nam;Rhee, Sang-Bong;Lee, Sang-Keun;Song, Kyung-Bin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.12
    • /
    • pp.2311-2315
    • /
    • 2009
  • This paper presents a method to apply energy margin for assesment of total transfer capability (TTC). In order to calculate energy margin, two values of the transient energy function have to be computed. The first value is transient energy that is the sum of kinetic and potential energy at the end of fault. The second is critical energy that is potential energy at controlling UEP(Unstable Equilibrium Point). It is seen that TTC level is determined by not only bus voltage magnitudes and line thermal limits but also transient stability. TTC assessment is compared by the repeated power flow(RPF) method and optimization method.

Improving Assessment of External Environment for Green Standard for Energy & Environmental Design Certification according to Climate Change (기후변화에 따른 녹색건축인증제도의 외부환경 평가항목 개선방향 연구)

  • Kim, Ji-Hyeon;Kwon, Hyuck-Sam;Kim, Jung-Gon;Song, Ok-Hee
    • Land and Housing Review
    • /
    • v.8 no.3
    • /
    • pp.171-180
    • /
    • 2017
  • In 1990s, as the extreme weather events according to the global warming climate change are occurred frequently all around the world and the scale of the damage increases, the developed countries are promoting various policies for reducing greenhouse gas emissions setting the goal of greenhouse gas reduction with the level of State and local government. Especially for the greenhouse gas reduction of buildings and the inducement of eco-friendly design, the green certification system is strengthened with the assessment of energy and greenhouse management, and recently, according to the policy change of climate and energy, the certification system expanded from the buildings to the level of city and district is piloted. So this research is to understand the main contents and the assessment system of domestic green building certification system implemented in March 2013 in response to the policy change of climate and energy and to suggest the basic data for the improvement of present domestic greenhouse certification standard through the analysis of actual certification and the main case analysis of international green certification system. Recently in developed countries, in 1990s, for the reduction of building's greenhouse gas emission and the inducement of eco-friendly design, from the building of LEED, BREEAM, DGNB to the level of city and district such as LEED Neighborhood Development, BREEAM Communities, DGNB Stadtquartiere, the system is expanded and piloted. On the contrary, as for the domestic standard of green building certification system, the distribution ratio according to the assessment items in each category consists of the assessment system based on the buildings, and just the simple adjustment of some items and the improvement of weighted value are performed. Actually, as a result of selecting the 30 districts of apartment housing with the most certification performance by use among the 49 buildings certified by Institute of Land & Housing from December 2014 to July 2016 and analyzing the assessment score, the certification level is determined by the sectors of high distribution like indoor environment and energy not by the ineffective sector of external environment with low distribution so this system has a limitation to perform the practical means for the policy change of climate and energy. Thus for the national green building certification standards, the assessment system in the sector of external environment is to complemented and furthermore, reflecting domestic reality, through the introduction of certification system and the assessment system with the level of city and district, this system should be improved to meet the international certification standard.

Computational Analysis of Structural Behavior of Subsea Pipelines with Local Corrosion (국부 부식을 가지는 심해저 파이프라인의 구조응답에 대한 전산 해석적 연구)

  • Choi, Kwang-Ho;Lee, Chi-Seung;Ryu, Dong-Man;Koo, Bon-Yong;Song, Joon-Kyu;Lee, Jae-Myung
    • Journal of Ocean Engineering and Technology
    • /
    • v.29 no.1
    • /
    • pp.100-110
    • /
    • 2015
  • To meet the increasing demand for energy around the world, offshore and subsea energy development is constantly being conducted. This trend is accompanied by an increasing demand for pipeline installation, which brings numerous problems, including those related to accessibility, high pressure, and corrosion. Among these, corrosion is a primary factor in pipeline fractures, and can cause severe environmental and industrial damage. Hence, accurate corrosion assessment for corroded pipelines is very important. For this reason, the present study investigated the mechanical behavior of an idealized corroded subsea pipeline with an internal/external pressure load using the commercial FEA code ABAQUS. Then, the analysis result was compared with corrosion assessment codes such as ASME B31G, DNV RP F101, ABS. Finally, a fitness-for-service assessment was conducted.

Utilization of Energy Storage System based on the Assessment of Area of Severity in Islanded Microgrid

  • Lee, Kyebyung;Yoon, Minhan;Park, Chang-Hyun;Jang, Gilsoo
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.569-575
    • /
    • 2017
  • This paper proposes a method to utilize an energy storage system (ESS) based on the assessment of an area of severity (AOS) to voltage sag. The AOS is defined as a set of the fault positions that can cause voltage sags at many buses simultaneously. The assessment of AOS helps to determine an optimal location of ESS installation to minimize the expected sag frequency (ESF) at concerned buses. The ESS has the ability not only to play traditionally known roles but also to mitigate voltage sag impact on renewable energy sources (RES) in the islanded microgrid. Accordingly, using the proposed method the ESS has additional features to prevent the operation failure of RESs and improve the stability of the microgrid. In order to verify the presented method, a case study was conducted on the sample microgrid system that is modified from an IEEE 57-bus system.

Life Cycle Assessment for the Business Activities of Green Company -1. Analysis of Process Flow and Basic Unit (녹색기업의 사업활동 전 과정에 대한 환경성 평가 -1. 공정 흐름 및 원단위 분석)

  • Shin, Choon-Hwan;Park, Do-Hyun
    • Journal of Environmental Science International
    • /
    • v.22 no.3
    • /
    • pp.269-279
    • /
    • 2013
  • In this paper, an environmental assessment was carried out on the whole process of industrial business activities to establish a basic plan for climate change mitigation and energy independency. The whole process was divided into each discharge process in terms of water, air, solid waste, green house gases and refractory organic compounds. The flowcharts and basic unit of process were analysed for three years (2008-2010), being utilized as basic information for the life cycle assessment. It was found that the unit loading for the whole process significantly depends on changes in the operation rate change and highly concentrated wastewater inflow. About 35% of solid waste production was reduced by improving the incineration method with co-combustion in coal boiler, generating about 57% of electricity used for the whole process, and consequently reducing the energy costs. As the eco-efficiency index was found to be more than 1, compared to the previous years, it can be said that improvement in general has taken place.

INTEGRATED SOCIETAL RISK ASSESSMENT FRAMEWORK FOR NUCLEAR POWER AND RENEWABLE ENERGY SOURCES

  • LEE, SANG HUN;KANG, HYUN GOOK
    • Nuclear Engineering and Technology
    • /
    • v.47 no.4
    • /
    • pp.461-471
    • /
    • 2015
  • Recently, the estimation of the social cost of energy sources has been emphasized as various novel energy options become feasible in addition to conventional ones. In particular, the social cost of introducing measures to protect power-distribution systems from power-source instability and the cost of accident-risk response for various power sources must be investigated. To account for these risk factors, an integrated societal risk assessment framework, based on power-uncertainty analysis and accident-consequence analysis, is proposed. In this study, we applied the proposed framework to nuclear power plants, solar photovoltaic systems, and wind-turbine generators. The required capacity of gas-turbine power plants to be used as backup power facilities to compensate for fluctuations in the power output from the main power source was estimated based on the performance indicators of each power source. The average individual health risk per terawatt-hours (TWh) of electricity produced by each power source was quantitatively estimated by assessing accident frequency and the consequences of specific accident scenarios based on the probabilistic risk assessment methodology. This study is expected to provide insight into integrated societal risk analysis, and can be used to estimate the social cost of various power sources.

Multi-unit Level 2 probabilistic safety assessment: Approaches and their application to a six-unit nuclear power plant site

  • Cho, Jaehyun;Han, Sang Hoon;Kim, Dong-San;Lim, Ho-Gon
    • Nuclear Engineering and Technology
    • /
    • v.50 no.8
    • /
    • pp.1234-1245
    • /
    • 2018
  • The risk of multi-unit nuclear power plants (NPPs) at a site has received considerable critical attention recently. However, current probabilistic safety assessment (PSA) procedures and computer code do not support multi-unit PSA because the traditional PSA structure is mostly used for the quantification of single-unit NPP risk. In this study, the main purpose is to develop a multi-unit Level 2 PSA method and apply it to full-power operating six-unit OPR1000. Multi-unit Level 2 PSA method consists of three steps: (1) development of single-unit Level 2 PSA; (2) extracting the mapping data from plant damage state to source term category; and (3) combining multi-unit Level 1 PSA results and mapping fractions. By applying developed multi-unit Level 2 PSA method into six-unit OPR1000, site containment failure probabilities in case of loss of ultimate heat sink, loss of off-site power, tsunami, and seismic event were quantified.