By using the transmission anode x-ray tube developed to apply to the hand-held XRF equipment, we carried out XRF experiment and evaluated the influences of the x-ray tube on XRF spectra. XRF data, which is measured using the W-target and Rh-target tube, were good agreements with the known results. FWHM of Fe $K_{\alpha}$-line measured by W-target tube with the 35 kV-tube voltage and the $40{\mu}A$-tube current was 180 eV. This result reveals that our XRF equipment using the transmission anode x-ray tube is enough for a qualitative analysis of materials. By comparison XRF data with the integrated intensity of x-ray tube, it was confirmed that Rh-target tube is better than W-target tube for application to the hand-held XRF equipment.
We report the successful fabrication and I-V curve superconductivity test results of the Nb/Al-based superconducting tunnel junctions. STJs with side-lengths of 20, 40, 60 and $80{\mu}m$ were fabricated by deposition of polycrystalline Nb/Al/AlOx/Al/Nb 5-layer thin films incorporated on a 3-inch Si wafer. STJ was designed by $Tanner^{TM}$ L-Edit 8.3 program, and fabricated in SQUID fabrication facility, KRISS. S-layer STJ thin-films were fabricated using UV photolithography, DC magnetron sputtering, Reactive ion etching, and CVD(Chemical Vapor Deposition) techniques. Superconducting state test for STJ was succeeded in 4K with liquid helium cooling system. Their performance indicators such ie energy gap, normal resistance, normal resistivity, dynamic resistance, dynamic resistivity, and quality factor were measured from I-V curve. Fabricated Nb/Al STJ shows $11\%$ higher FWHM energy resolution than genuine Nb STJ.
Kim, Hee-Joung;Son, Hye-Kyung;Bong, Joung-Kyun;Nam, Ki-Pyo;Lee, Hee-Kyung
The Korean Journal of Nuclear Medicine
/
v.30
no.3
/
pp.372-378
/
1996
In the case of $^{123}I$ from the $^{124}Te$(p,2n)reaction, the radionuclidic impurity is the high-energy gamma-emitting $^{124}I$, which interferes greatly with nuclear medicine images. The choice of a collimator can affect the quality of clinical SPECT images of [I-123]MIBG, [I-123] ${\beta}$-CIT, or [I-123]IPT. The tradeoffs that two different collimators make among spatial resolution, sensitivity, and scatter were studied by imaging a line source at 5cm, 10cm, 15cm distance using a number of plexiglass sheets between source and collimator, petri dish, two-dimensional Hoffman brain phantom, Jaszczak phantom, and three-dimensional Hoffman brain phantom after filling with $^{123}I$. (FWHM, FWTM, Sensitivity) for low-energy ultrahigh-resolution parallel - hole (LEUHRP) collimator and medium- energy general - purpose (MEGP) collimator were measured as (9.27mm, 61.27mm, $129CPM/{\mu}Ci$) and (10.53mm, 23.17mm, $105CPM/{\mu}Ci$), respectively. The image quality of two-dimensional Hoffman brain phantom with LEUHRP looked better than the one with MEGP. However, the image quality of Jaszczak phantom and three-dimensional Hoffman brain phantom with LEUHRP looked much worse than the one with MEGP because of scatter contributions in three-dimensional imaging situation. The results suggest that the MEGP is preferable to LEUHRP for three-dimensional imaging studies of [I-123]MIBG, [I-123] ${\beta}$-CIT, or [I-123]IPT.
Kim, J. H.;Choi, Y.;Kim, J. Y.;Oh, C. H.;Kim, S. E.;Choe, Y. S.;Lee, K. H.;Joo, K. S.;Kim, B. T.
Journal of Biomedical Engineering Research
/
v.20
no.6
/
pp.515-521
/
1999
Scintillator crystal is an important part and detcrmines performance characteristics of the gamma camera. We investigated the offects of scintillation crystal surface treatment on gamma camera imaging. Nal(TI) and Csl(Tl) scintillators. 20 mm diameter and 10 mm thickness, applied with two different surface treatments, white and black reflcetors, were applied to Nal(Tl) and Csl(Ti). The optical properties of generated scintillation light were evaluated by Monte Carlo simulation method and by actual measurement using a position sensitive photomultiplier tube (PSPMT). We measured sensitivity, energy resolution and spatial resolution of gamma camera with the various scintillators coupled to a PSPMT. In the simulation. Nal(Tl)-white prosented the best sensitivity. In the measurements, the sensitivities and the intrinsic spatial resolutions of Nal(Tl)-white, Nal(Tl)-black. CsI(Tl)-white, CsI(Tl)-black were 2920, 2322, 1754, 1401 cps/$\mu$ci and 5.2, 4.5, 7.0, 6.3 mm FWHM. respectively. Their intrinsic energy resolutions were mesured 12.5, 23.5, 20.5, 33.3% FWHM at 140 keV Tc-99m. In this study, we investigated the offects of a side surface treatment of the scintillator on the gamma camera imaging. Simulation and measurement prescnted similat trends. Based on the results, we concluded that the surface of th NaI(Tl)seintillator must be treated by absorptive materials in order to develop the gamma camera having good spatial resolution.
We are developing meander-shaped metallic magnetic calorimeters using micro-fabrication methods. A planar Nb coil in a meander shape was fabricated on a Si substrate. The coil was designed to have a persistent current using a metal heater evaporated on a part of the coil. A paramagnetic sensor, $5{\mu}m$ thick Au:Er foil, was glued on top of the meander structure with epoxy. The magnetization and heat capacity were measured at different temperatures, and applied field currents matched well with expected values. The detector showed an energy resolution of 4 keV FWHM for the 5.5 MeV alpha particles.
We have grown a high quality ZnSe(100) epilayer on the GaAs(100) substrate by hot-wall epitaxy method. The FWHM value from double-crystal x-ray diffraction rocking curve and growth rate of the ZnSe epilayer grown under the optimal growth conditions were 195 arcsec and 0.03 $\mu \textrm m$/min, respectively. The $I_2^U$ and $I_2^L$ peaks, which split by strain due to lattice mismatch between substrate and epilayer, were measured from the photoluminescence experiment. And we found that the residual impurities in ZnSe epilayer were concerned with Al or CI elements from the calculated binding energy of donor impurity.
Journal of the Korean Institute of Electrical and Electronic Material Engineers
/
v.21
no.10
/
pp.943-949
/
2008
We report on the development of transition edge sensors for x-ray detection. The sensor technology was based on the fabrication of a superconducting film on a thin membrane. A bilayer of a superconductor, Ti, and a noble metal, Au, was e-beam evaporated on a micromachined SiNx. Another Au layer was evaporated on the two side edges of the bilayer in order not to be affected by structural imperfections at the boundaries. With the method described in the present report, the superconducting transition temperature of the device was consistently achieved to near 80 mK with a sharp transition. The energy spectrum ueasured with the device provided 37 eV FWHM for 5.9 x-rays. We also discuss the design and fabrication considerations as well as the performance of the device in detail.
KIEE International Transactions on Electrophysics and Applications
/
v.3C
no.6
/
pp.241-245
/
2003
ZnO thin films on (l00) p-type Si and sapphire substrates have been deposited by a pulsed laser deposition technique using an Nd:YAG laser with a wavelength of 266 nm. The influence of the deposition parameters such as oxygen pressure, substrate temperature and laser energy density on the properties of the grown films was studied. The experiments were performed for substrate temperatures in the range of 200∼50$0^{\circ}C$ and oxygen pressure in the range of 100∼700 sccm. All of the films grown in this experiment show strong c-axis orientation with (002) textured ZnO peak. With increasing substrate temperature, the FWHM (full width at half maximum) and surface roughness were decreased. In the case of using sapphire substrate, the intensity of PL spectra increased with increasing ambient oxygen flow rate. We investigated the structural and morphological properties of ZnO thin films using X-ray diffraction (XRD), scanning electron microscopy (SEM) and atomic force microscopy (AFM).
Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
/
1997.11a
/
pp.44-47
/
1997
In spite of the addtion of Zn, a high quality of Zn-doped GaN film were prepared. The growth rates of Zn-doped GaN films were varied from 0.14${\mu}{\textrm}{m}$/min to 0.05${\mu}{\textrm}{m}$/min according to the amount of Zn incorporated, The smallest value of the FWHM of x-ray rocking curve was 407 arcsec. The Zn-related Photoluminescence emission peaks which occurred at 2.927 and 2.824 eV shifted toward the low energy region by increasing Zn partial pressures. It was compared between the intensities of D-A pair (3.259eV) and that of the exciton bound to acceptor band(E$_{x-A}$=3.449eV).).
A new gas jet Z-pinch EUV light source having double gas jet electrodes has been developed. It has two nozzles and two diffusers. The EUV beam is collected from the side of pinch plasma, generated in between the inner nozzle and corresponding diffuser. A cylindrical shell of He gas curtain produced by the outer nozzle is specially designed for shielding the debris and suppressing the inner gas expansion. We have succeeded in generating EUV energy of 1.22 mJ/sr/2%BW/pulse at 13.5nm. The estimated dimension of EUV source is to be FWHM diameter of 0.07 mm and length of 0.34 mm, and FW 1/e2 diameter of 0.15 mm and length of 1.2 mm.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.