• Title/Summary/Keyword: end-to-end joint

Search Result 651, Processing Time 0.025 seconds

Self-Organization of Visuo-Motor Map Considering an Obstacle

  • Maruki, Yuji
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1168-1171
    • /
    • 2003
  • The visuo-motor map is based on the Kohonen's self-organizing map. The map is learned the relation of the end effecter coordinates and the joint angles. In this paper, a 3 d-o-fmanipulator which moves in the 2D space is targeted. A CCD camera is set beside the manipulator, and the end effecter coordinates are given from the image of a manipulator. As a result of learning, the end effecter can be moved to the destination without exact teaching.

  • PDF

Design of Robot Rotation Arm with Parallel Motion in End Effector (말단 장치의 평면 유지가 가능한 로봇 회전 암의 설계)

  • Lee, Jong-Shin
    • The Journal of Korea Robotics Society
    • /
    • v.5 no.4
    • /
    • pp.359-366
    • /
    • 2010
  • This study proposes the design method for the robot rotation arm which the end effector that is connected in end of the arm keeps parallel motion even though the robot arm rotates. So far, most robot arm rotates together the end effector when the arm rotates. For this, this study proposes the mechanism that the arm is linked to each 4 parallel link so that rotation is possible by 4 pins, and the rotation arm connects 2 joints of diagonal line direction to a link in each 4 joint for rotation, and designs so that can change length of the link. For verification of design, this study targeted that develop the rotation arm for medical examination that use in ophthalmology. It is important that a medical robot offers comport to patient and design compactly so that medical examination and treatment space may can be defined enough. It is designed so that all drive elements may be positioned on interior of the arm and optimization of design for main parts was carried out in this study for this. The robot arm which is developed in this study manufactured to use by medical phoropter arm, and got good result by an experiment. The robot rotation arm which is proposed in this study is judged to contribute very effectively in case use of a medical robot arm for medical examination and treatment, also the robot arm which the end effector that is connected in the end of the arm needs to keep parallel motion. And, the robot arm which is developed in this study made an application as license.

A two-step approach for joint damage diagnosis of framed structures using artificial neural networks

  • Qu, W.L.;Chen, W.;Xiao, Y.Q.
    • Structural Engineering and Mechanics
    • /
    • v.16 no.5
    • /
    • pp.581-595
    • /
    • 2003
  • Since the conventional direct approaches are hard to be applied for damage diagnosis of complex large-scale structures, a two-step approach for diagnosing the joint damage of framed structures is presented in this paper by using artificial neural networks. The first step is to judge the damaged areas of a structure, which is divided into several sub-areas, using probabilistic neural networks with natural Frequencies Shift Ratio inputs. The next step is to diagnose the exact damage locations and extents by using the Radial Basis Function (RBF) neural network with the second Element End Strain Mode of the damaged sub-area input. The results of numerical simulation show that the proposed approach could diagnose the joint damage of framed structures induced by earthquake action effectively and has reliable anti-jamming abilities.

A study on the Optimum Conditions of Nd:YAG LBW for Zircaloy-4 End Cap Closure By Optical Fiber Transmission (광섬유전송에 의한 Zircaloy-4 봉단마개밀봉의 Nd:YAG LBW의 최적조건에 관한 연구)

  • 김수성;김웅기;이영호
    • Journal of Welding and Joining
    • /
    • v.15 no.6
    • /
    • pp.85-95
    • /
    • 1997
  • This study is to investigate the optimum conditions of Nd:YAG laser beam welding for Zircaloy-4 end cap closure by optical fiber transmission. Laser welding parameters which affect the penetration depth and bead width were experimentally examined using the various beam radius by the beam quality analyzer, joint geometries of end cap and the laser parameters which mean pulse width, repetition rate and pulse energy. Also, an optimum welding speed and the effect of assistant gas with varying the flow rate of He were investigated. We found that the laser average power for the end cap welding will be 230W and rotation speed must not exceed 8 RPM, the best position of focus using optical fiber with 600.mu.m will be 2 to 3mm below the surface of the material.

  • PDF

A Comparative Research on End-to-End Clinical Entity and Relation Extraction using Deep Neural Networks: Pipeline vs. Joint Models (심층 신경망을 활용한 진료 기록 문헌에서의 종단형 개체명 및 관계 추출 비교 연구 - 파이프라인 모델과 결합 모델을 중심으로 -)

  • Sung-Pil Choi
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.57 no.1
    • /
    • pp.93-114
    • /
    • 2023
  • Information extraction can facilitate the intensive analysis of documents by providing semantic triples which consist of named entities and their relations recognized in the texts. However, most of the research so far has been carried out separately for named entity recognition and relation extraction as individual studies, and as a result, the effective performance evaluation of the entire information extraction systems was not performed properly. This paper introduces two models of end-to-end information extraction that can extract various entity names in clinical records and their relationships in the form of semantic triples, namely pipeline and joint models and compares their performances in depth. The pipeline model consists of an entity recognition sub-system based on bidirectional GRU-CRFs and a relation extraction module using multiple encoding scheme, whereas the joint model was implemented with a single bidirectional GRU-CRFs equipped with multi-head labeling method. In the experiments using i2b2/VA 2010, the performance of the pipeline model was 5.5% (F-measure) higher. In addition, through a comparative experiment with existing state-of-the-art systems using large-scale neural language models and manually constructed features, the objective performance level of the end-to-end models implemented in this paper could be identified properly.

The Function and Symptoms of Ankle Joint in the Distal Tibial Fractures Treated by Nailing (족관절 기능과 증상을 중심으로 평가한 경골 원위부 골절에서의 금속정 치료 결과)

  • Kim, Byoung-Min;Bae, Su-Young;Roh, Jae-Young
    • Journal of Korean Foot and Ankle Society
    • /
    • v.12 no.1
    • /
    • pp.86-92
    • /
    • 2008
  • Purpose: To evaluate the safety and prognostic factors of intramedullary nailing of distal tibia fractures in terms of function and symptoms of the ankle joint. Materials and Methods: We retrospectively analyzed 22 distal tibial fractures with intramedullary nailing. The mean duration of follow-up was 43 months. We reviewed medical records to describe each case. We measured radiographic parameters such as fracture configuration, arthritic change of the ankle joint and status of reduction. We also assessed clinical results by AOFAS ankle hind foot scoring system, degree of pain by VAS and range of motion to find out prognostic factors for functional result of the ankle joint. Results: Bone healing was obtained in all cases without any wound complications. Mean AOFAS ankle score was 94. There were 4 cases with mild (VAS<3/10) ankle pain and 2 cases with mild limitation of ankle motion. The comminution of fracture had a significant relationship with delayed angular deformity of ankle joint (p=0.032). There was no other significant parameter affecting ankle joint function except the location of nail-end. Conclusion: Intramedullary nailing in distal tibia fracture is a safe and effective procedure. But further study may need to evaluate the relationship between the position of nail-end and the function of ankle joint.

  • PDF

Different Biomechanical Characteristics in Proprioception, Muscle Strength, and Time to Peak Torque at Velocity of 300°/sec of the Ankle Joint in People With or Without Functional Ankle Instability (각속도 300°/sec에서 기능적 발목불안 유무에 따른 고유수용성감각, 발목 근력, 그리고 최고 회전력까지 걸리는 시간의 생체역학적 특성 차이)

  • Park, Eun-Young;Kim, Won-Ho
    • Physical Therapy Korea
    • /
    • v.20 no.3
    • /
    • pp.45-53
    • /
    • 2013
  • The purpose of this study was to examine the differentiation of proprioception, invertor and evertor muscle strength, and time to peak torque at a velocity of $300^{\circ}/sec$ of the ankle joint in people with or without functional ankle instability (FAI). Nineteen subjects with a history of ankle sprain participated. All subjects were divided into FAI group ($n_1=9$, Cumberland ankle instability tool (CAIT)${\leq}24$) and a control group ($n_2=10$) based on their CAIT scores. Isokinetic dynamometer was used to measure the sense of active joint position of the ankle at mid-range and end-range of an inversion motion and invertor as well as the evertor muscle strength and time to peak torque at $300^{\circ}/s$. The FAI group showed a statistically reduction in invertor and evertor muscle strength and time to peak torque when compared to the control group (p<.05). Muscle strength and time to peak torque of the invertor and evertor, as well as the sense of active joint position at end-range were also lower in the FAI group than in the control (p<.05). Correlations between CAIT score and position sense at end-range (r=-.577) and invertor muscle strength (r=.554) were statistically significant (p<.05). Individuals with FAI showed reduction in invertor and evertor muscle strength and recruitment time as well as in proprioception of the ankle joint. Thus, proprioception and invertor and evertor muscle strength of the ankle joint at fast angular velocity may be investigated when examining and planning care for individuals with FAI.

Comparison of Ankle Arthrodesis and Total Ankle Arthroplasty in End-Stage Ankle Arthritis (말기 발목 관절염 환자에서 발목 유합술과 발목관절 전치환술의 비교)

  • Young Sik, Yoon;Dong Yeon, Lee
    • Journal of Korean Foot and Ankle Society
    • /
    • v.26 no.4
    • /
    • pp.151-156
    • /
    • 2022
  • The proportion of patients with end-stage ankle arthritis is increasing. The leading surgical methods for treating patients with end-stage ankle arthritis are ankle arthrodesis and total ankle arthroplasty. Ankle arthrodesis is considered the standard treatment for end-stage ankle arthritis. Many studies have been conducted on the two procedures, but it is unclear which is superior, and total ankle arthroplasty cannot be said to be a clear indication. Therefore, this review compares the advantages and disadvantages of two representative surgical methods for treating end-stage ankle arthritis.

Stress Analysis Of Wavy Lap Joint (WAVY LAP JOINT 응력 해석)

  • 김위대;양승희
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2000.11a
    • /
    • pp.216-219
    • /
    • 2000
  • The adhesive bonded single-lap joint is due to its intrinsic load eccentricity problem, severe peel stresses concentration occur at both end of the joint. In this paper, new lap-joint is designed to avoid the singular peel stress, and to compare the stresses of the middle adhesive layer between the single-lap joint and the wavy-lap joint. Two adherend lay-up, i.e., [90/0/90/0]$_{2s}$ and [0/90/0/90]$_{2s}$ were consider in the study.

  • PDF

A Fundamental Study on Development of Non-Welded Flexible Joint (무용접 후렉시블 조인트 개발에 관한 기초연구)

  • Oh, Choel-Hoon;Park, Hwan-Chul;Jeong, Ji-Hyun
    • Journal of Power System Engineering
    • /
    • v.21 no.1
    • /
    • pp.57-62
    • /
    • 2017
  • The flexible joint with bellows and flange is made by welding bellows and flange in general. The welded parts cause a crack or demage in the flexible joint due to continuous vibration and fatigue limit. This paper is concerned with development of flexible joint with non-welded, free rotation of flange and non-packing to improve fatigue failure condition between bellows and flange. The support box and support plate that are components of press part are designed to compress fore-end of bellows only without demage of bellows. The production system of flexible joint is designed with piston attached on the compression side. The simulation is performed using Deform 3D software. As the result of simulation, the shape of compressed bellows was most proper in the compression power of $157kg{\cdot}f$ and any deformation has not occurred at a part besides fore-end. The result show that the production possibility of the designed flexible joint.