• Title/Summary/Keyword: end cap

Search Result 94, Processing Time 0.024 seconds

Influence of Pile Cap's Boundary Conditions in Piled Pier Structures (교량 말뚝기초의 단부 지점조건의 영향분석)

  • Won Jin-Oh;Jeong Sang-Seom
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.5
    • /
    • pp.15-24
    • /
    • 2005
  • Modeling techniques of piled pier were reviewed and the influences of pile cap's boundary conditions were analyzed in this study. The method using flexible springs seems to be useful fur the practical design since its simplified model can represent the complex behaviors of pile groups efficiently. Parameter studies were performed far various pile group arrangements, pile spacings, end bearing conditions, and loading stages to analyze their effects on the lateral displacements, maximum pile bending stresses, and lateral stiffness of pile groups. Through the parameter studies, it was found that when lateral stiffness of pile groups was estimated by using three-dimensional analysis method (YSGroup), its complex behavior could be predicted better than other methods based on single pile analysis.

The Structure and The Reason for Nuclear Accumulation of Poly A(-) Spliced SV40 RNA (Poly A tail이 없는 SV 40 spliced RNA의 구조 및 핵내 축적의 원인)

  • 박주상;노정혜
    • Korean Journal of Microbiology
    • /
    • v.27 no.1
    • /
    • pp.1-9
    • /
    • 1989
  • The locations of 5' ends as well as the splicing pattern of viral poly A(-) 19S RNA from monkey cells infected with SV40 were determined by a modification of primer extension method. The 5' end of this RNA mapped at the major cap site at nucleotide residue 325, used most frequently by SV40 late RNAs. The intron from nt.373 to nt.558 was removed as the ordinary cytoplasmic poly A(+) 19S RNA. The 3'end of this RNA was very heterogeneous and distributed over 1 kb upstream of polyadenylation site, as determined by S1 nuclease mapping. The reason for this normally initiated and spliced RNA to accumulate in the nucleus was investigated. In order to test whether the presence of unused 3' splice region on this RNA caused such subcellular distribution, cells were transfected with SV40 mutant KNA containing deletion around 3' splice site. The RNA deleted of 3' splice region accumulated mainly in the cytoplasm. This accumulation did not result from the increased stability of the RNA due to the deletion, since the wild type and mutant RNAs exhibited similar half lives after chase with actinomycin D. Therefore it is likely that the 19S spliced RNA is hindered from being transported into the cytoplasm due to some pre-splicing complexes formed at the unused 3' splice site.

  • PDF

Laboratory investigation of unconfined compression behavior of ice and frozen soil mixtures

  • Jin, Hyunwoo;Lee, Jangguen;Zhuang, Li;Ryu, Byung Hyun
    • Geomechanics and Engineering
    • /
    • v.22 no.3
    • /
    • pp.219-226
    • /
    • 2020
  • Unconfined compression test (UCT) is widely conducted in laboratories to evaluate the mechanical behavior of frozen soils. However, its results are sensitive to the initial conditions of sample creation by freezing as well as the end-surface conditions during loading of the specimen into the apparatus for testing. This work compared ice samples prepared by three-dimensional and one-dimensional freezing. The latter created more-homogenous ice samples containing fewer entrapped air bubbles or air nuclei, leading to relatively stable UCT results. Three end-surface conditions were compared for UCT on ice specimens made by one-dimensional freezing. Steel disc cap with embedded rubber was found most appropriate for UCT. Three frozen materials (ice, frozen sand, and frozen silt) showed different failure patterns, which were classified as brittle failure and ductile failure. Ice and frozen sand showed strain-softening, while frozen silt showed strain-hardening. Subsequent investigation considered the influence of fines content on the unconfined compression behavior of frozen soil mixtures with fines contents of 0-100%. The mixtures showed a brittle-to-ductile transition of failure patterns at 10%-20% fines content.

VDSL 가입자 전송기술 개발 및 표준화 동향

  • 강규민;임기홍
    • Information and Communications Magazine
    • /
    • v.16 no.10
    • /
    • pp.112-124
    • /
    • 1999
  • 본 논문에서는 FTTC/VDSL (Fiber-to-the-Curb/Very High-speed Digital Subscriber Line) 전송시스템의 개발동향과 ANSI, ETSI, ITU등의 표준화 위원회에서 현재 진행중인 VDSL 시스템의 표준화 작업에 대해 기술하였다. 특히, POTS (Plain Old Telephone Service), BA-ISDA(Basic Access Integrated Services Digital Network), HDSL(High-rate Digital Subscriber Line), SDSL (Single-pair HDSL), ADSL(Asymmetric Digital Subscriber Line) 등의 다양한 xDSL (Digital Subscriber Line) 서비스들에서 발생하는 NEXT (Near-end Crosstalk)/FEXT (Far-end Crosstalk)와 같은 crosstalk를 최소화하기 위해 제안된 VDSL시스템의 주파수 대역과 PSD (Power Spectral Density) mask에 관해 설명하고, 순방향(down-stream) 채널과 역방향(upstream) 채널의 데이터 전송률이 대칭적인 VDSL전송시스템과 비대칭적인 VDSL 전송시스템 간의 주파수대역의 호환성 문제, RFI(Radio Frequency Interference) ingress/egress 문제의 해결 방안에 관해 기술하였다. 또한, 현재 VDSL Coalition과 VDSL Alliance 간에 논의 중인 VDSL 전송시스템의 변복조 방식에 관한 표준화 작업과정 및 순방향과 역방향에 할당될 band 개수에 따른 시스템 성능의 장단점 등에 관해 살펴보았다. 끝으로 현재 국내에서 개발되고 있는 FTTC/VDSL 전송시스템의 전체구조를 요약하고, 네트워크에서 가입자쪽으로 순방향 데이터 전송에 사용된 51.84 Mb/s 19-CAP (Carrierless Amplitude/Phase Modulation) 전송시스템과 가입자 댁내에서 네트워크 방향으로 역방향 데이터 전송에 사용된 1.62 Mb/s QPSK (Quadrature Phase Shift Keying) burst-mode TDMA (Time Division Multiple Access) 전송시스템 등의 동작 원리 및 구조를 기술하였다.

  • PDF

Ten-Year Performance of Shell-Treated Wooden Deck

  • RA, Jong Bum
    • Journal of the Korean Wood Science and Technology
    • /
    • v.47 no.6
    • /
    • pp.667-673
    • /
    • 2019
  • The performance of a wooden deck made of refractory materials that have difficulties in achieving target penetrations as stipulated in the specification and quality standards for treated wood in Korea, was assessed via a case study in this research. A wooden deck built in Jinju in 2009 was selected for this study because of its fabrication method using pressure and treated refractory materials. The penetration and retention analysis did not satisfy the domestic standard for treated wood. Inspection of the deck in 2019 revealed that the deck had been attacked by decay fungi. Cap rails showed much deeper and wider checking on their surface compared with the top and base rails, resulting in a severe fungal attack. The decking boards exhibited severe fungal decay primarily in the end parts. However, the rails and balusters without checks and posts were virtually free of fungal attack irrespective of the preservative penetration measures. Copper content in the soil 5 cm away from the deck was less than 150 mg/kg, implying that copper movement in the soil was very limited. These results suggest that the inhibition of surface propagation and the protection of end surfaces are essential factors in increasing the longevity of treated wooden decks; further, the results also showed that the deck was within an acceptable range from the point of copper contamination.

Coil-to-globule transition of thermo-responsive γ-substituted poly (ɛ-caprolactone) in water: A molecular dynamics simulation study

  • Koochaki, Amin;Moghbeli, Mohammad Reza;Nikkhah, Sousa Javan
    • Current Applied Physics
    • /
    • v.18 no.11
    • /
    • pp.1313-1319
    • /
    • 2018
  • The coil-to-globule behavior of poly{${\gamma}$-2-[2-(2methoxyethoxy)ethoxy]ethoxy-3-caprolactone} (PMEEECL) as a ${\gamma}$-substituted poly (${\varepsilon}$-caprolactone) was investigated via atomistic molecular dynamics (MD) simulation. For this purpose, radius of gyration, end-to-end distance and radial distribution function of the chain in the presence of water were calculated. Consequently, the lower critical solution temperature (LCST) of PMEEECL chain at which the coil-to-globule transition takes place, was determined in each calculated parameter curve. The simulation results indicated that the LCST of PMEEECL was occurred at close to 320 K, which is in a good agreement with previous experimental results. Additionally, the appearance of sudden change in both Flory-Huggins interaction parameter (${\chi}$) and interaction energy between the PMEEECL chain and water molecules at about 320 K confirmed the calculated LCST result. The radial distribution function (RDF) results showed that the affinity of the PMEEECL side chain to water molecules is lower than its backbone.

End of lamp life effect with 36W Single-Cap Fluorescent lamps (36W 단일 캡 형광램프의 수명말기 과열현상에 관한 연구)

  • Won, Chang-Sub;Hong, Jea-Il;Lee, Myung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2006.10b
    • /
    • pp.221-223
    • /
    • 2006
  • 최근 수요가 급증한 36W 단일 캡 형광램프의 과열로 인하여 화재의 위험성이 대두되고 있다. 단일 캡 형광램프는 이중 캡에 형광램프에 비하여 길이가 작아 다루기가 쉽고, 관 지름이 작아 고효율의 형광램프로 인식되고 있다. 그러나 한쪽방향에 전극을 가지고 있어 열 분산 면에서 이중 캡에 비하여 열 축적 가능성이 크고, 수명말기에 전극필라멘트가 열에 의해 소실되었을 경우 관경이 작아 필라멘트 지지 스템(stem)의 길이가 가까워 고속스위칭의 전자식안정기를 적용한 시스템에서 완전히 개방되지 않고 임피던스의 상승만을 가져올 수 있다. 이로 인하여 캡의 열화에 의한 분리가 일어나고, 화재의 원인이 될 수 있다. 이러한 현상은 형광등의 수명 말기에 발생하는데 본 논문에서는 형광등의 수명말기 현상을 모델링하여 단일 캡 36W 형광램프의 수명 말기에 발생하는 과열에 관한 시험방법에 대하여 시험 연구 하였다.

  • PDF

Electron-Microscopic Studies on the Spermiogenesis and the Spermatozoa of the Drake and the Gander (오리와 거위의 정자완성과 정자에 관한 전자현미경적 연구)

  • 배대식;김종욱
    • Korean Journal of Animal Reproduction
    • /
    • v.11 no.3
    • /
    • pp.206-217
    • /
    • 1987
  • Testes from the drake and the gander have been examined by the electron microscopy in thin sections in order to examine the spermiogenesis and the structure of spermatozoa. The spermiogenesis can be divided into three stages: early spermatid, nuclear elongation, and matured spermatid. In the early spermatid of the drake, there are thread-like material in the nucleus, a prominent nuclear envelope around the nucleus, and big lumens in the cytoplasm. The shape of the gander's mitochondria in the early spermatid is slender compared to that of the drake, and the inner membrane of the mitochondria is thicker than the outer membrane. The distal centriole of the drake and the gander in the early spermatid is a long hollow cylinder form. In the nuclear elongation stage, elongated nucleus forms two or three cross sections in one spermatid cell and it is surrounded by the amorphous sheath. The nucleus of the matured spermatid is compact and its apical end is covered with acrosome cap and acrosome spine. The axoneme is surrounded by the amorphous material.

  • PDF

Corrosion Properties of Zircaloy-4 Cladding Tube having a Laser Welding Part in Elevated Temperature (Zircaloy-4 핵연료봉 레이저 용접부의 고온부식 특성 연구)

  • Kim, D.G.;Park, J.S.;Kim, S.T.;Yang, M.S.;Lee, J.W.;Kim, S.S.;Jung, Y.H.
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.256-261
    • /
    • 2001
  • Corrosion and tensile properties of zircaloy-4 cladding tube having a laser welding part in elevated temperature are studied to present the criterion of quality evaluation in nuclear reactor and to found the scientific basis of SCC, with laser welding method using by coupling up cladding tube to end cap. In the result of tensile test($400^{\circ}C$), the fracture is not happened in the welding part but base metal and the result of corrosion test($400^{\circ}C$ 1500psi steam), corrosion rate of the molten zone and PMZ is a little higher than the other zone.

  • PDF

A Study on the Laser Beam Weldability Using Zircaloy-4 Cladding Tube (지르칼로이-4 피복관을 이용한 레이저용접성 연구)

  • 박진석;김동균;김상태;양명승;김수성;이정원
    • Journal of Welding and Joining
    • /
    • v.20 no.6
    • /
    • pp.72-72
    • /
    • 2002
  • Corrosion and tensile properties of zircaloy-4 cladding tube having a laser welding part in elevated temperature are studied to present the criterion of quality evaluation in nuclear reactor and find the scientific basis of SCC, with laser welding method using by coupling up cladding tube to end cap. In the result of tensile test(400℃), the fracture is not happened in the welding part but base metal and the result of corrosion test(400℃ 1500psi steam), corrosion rate of the molten zone and PMZ is a little higher than the other zone.