• Title/Summary/Keyword: enamel

Search Result 1,084, Processing Time 0.022 seconds

A STUDY ON THE SHEAR BOND STRENGTH OF THE COMPOSITE RESIN ACCORDING TO THE SURFACE TREATMENT OF THE BLAEACHED ENAMEL (표백된 법랑질의 표면처리방법에 따른 복합레진과의 전단결합강도에 관한연구)

  • Kim, Eun-Hee;Cho, Young-Gon;Hwang, Ho-Keel
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.1
    • /
    • pp.351-361
    • /
    • 1995
  • The purpose of this study was to evaluate the shear bond strength of the composite resin bonded on the bleached enamel surface according to its surface treatment. 90 extracted human premolars were divided into six groups. : enamel unbleached (control group) and enamel bleached with 15% carbamide peroxide for 2 weeks (experimental groups: 1, 2, 3, 4 and 5). The surface of bleached enamel in all experimental groups was treated by following manners. Experimental group 1 : catalase immersion for 3 mimutes. Experimental group 2 : catalase immersion for 15 mimutes. Experimental group 3 : artificial saliva immersion for 1 hour. Experimental group 4 : artificial saliva immersion for 48 hours. Experimental group 5: surface reduction of the bleached enamel about 0.5mm-1mm with superfine diamond bur. Composite resin molds(3mm height, 3mm diameter) were bonded to the untreated enamel and treated. The shear bond strengths of composite resin bonded to enamel of each specimen were tested with universal testing machine at a crosshead speed of 5mm/min and 500Kg in full scale and analyzed statistically. The following results were obtained : 1. Control group had the highest shear bond strength with $19.92{\pm}5.14$ MPa and experimental group 5 had the lowest shear bond strength with $11.15{\pm}4.23$ MPa. 2. Control group showed significant differences in shear bond strength with experimental group 1(P<0.05). 3. Control group showed significant differences in shear bond strength with experimental group 5(P<0.05). 4. Experimental group 4 showed significant differences in shear bond strength with experimental group 5(P<0.05). 5. Experimental group 3 showed no significant differences in shear bond strength with experimental group 4(P<0.05).

  • PDF

Wear evaluation of CAD-CAM dental ceramic materials by chewing simulation

  • Turker, Izim;Kursoglu, Pinar
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.5
    • /
    • pp.281-291
    • /
    • 2021
  • PURPOSE. To evaluate the wear of computer-aided design/computer-aided manufacturing (CAD-CAM) dental ceramic materials opposed by enamel as a function of increased chewing forces. MATERIALS AND METHODS. The enamel cusps of healthy human third molar teeth (n = 40) opposed by materials from CAD-CAM dental ceramic groups (n = 10), including Vita Enamic® (ENA), a polymer-infiltrated ceramic network (PICN); GC Cerasmart® (CERA), a resin nanoceramic; Celtra® Duo (DUO), a zirconia-reinforced lithium silicate (ZLS) ceramic; and IPS e.max ZirCAD (ZIR), a polycrystalline zirconia, were exposed to chewing simulation (1,200,000 cycles; 120 N load; 1 Hz frequency; 0.7 mm lateral and 2 mm vertical motion). The wear of both enamel cusps and materials was quantified using a 3D laser scanner, and the wear mechanisms were evaluated by scanning electron microscopy (SEM). The results were analysed using Welch ANOVA and Kruskal Wallis test (α = .05). RESULTS. ZIR showed lower volume loss (0.02 ± 0.01 mm3) than ENA, CERA and DUO (P = .001, P = .018 and P = .005, respectively). The wear of cusp/DUO [0.59 mm3 (0.50-1.63 mm3)] was higher than cusp/CERA [0.17 mm3 (0.04-0.41 mm3)] (P = .007). ZIR showed completely different wear mechanism in SEM. CONCLUSION. Composite structured materials such as PICN and ZLS ceramic exhibit more abrasive effect on opposing enamel due to their loss against wear, compared to uniform structured zirconia. The resin nano-ceramic causes the lowest enamel wear thanks to its flexible nano-ceramic microstructure. While zirconia appears to be an enamel-friendly material in wear volume loss, it can cause microstructural defects of enamel.

Study on the Superlubricity and Running-in Period of Vitreous Enamel Coating using Phosphoric Acid (인산을 이용한 법랑 코팅의 초윤활성 및 초기 시간에 대한 연구)

  • Han, Do-Lyeol;Kim, Tae-Hyung;Kim, Dae-Eun
    • Tribology and Lubricants
    • /
    • v.34 no.6
    • /
    • pp.235-240
    • /
    • 2018
  • Superlubricity refers to the lubrication phenomenon that occurs when the friction coefficient is lower than 0.01. In recent years, this phenomenon has received a significant amount of attention because it can greatly contribute to the reduction of economic and environmental losses caused by friction and wear. In the case of acid lubricants, only ceramic materials can be used for superlubricity, and it takes a long running-in period to enter the superlubricity regime. In this work, we investigated the superlubricity effect of vitreous enamel coating on SUS304. We also examined the running-in period of vitreous enamel coating under phosphoric acid lubricant condition with respect to surface treatments. Drying and polishing methods were used to treat the vitreous enamel coating on the specimen. The friction experimental results revealed that superlubricity could be achieved with vitreous enamel coating. It was also found that the drying and polishing methods can significantly reduce the running-in period and improve the wear properties of vitreous enamel coating. In particular, the polishing method shortened the running-in period by approximately 99% and reduced the wear rate by approximately 99%, compared to nontreated vitreous enamel coating.

MARGINAL LEAKAGE TEST ON 'Hi-Pol' ENAMEL BOND SYSTEM (국산 'Hi-Pol' Enamel Bond System의 변연누출에 관한 실험적 연구)

  • Kwon, Hyuk-Choon
    • The Journal of the Korean dental association
    • /
    • v.16 no.12 s.115
    • /
    • pp.935-940
    • /
    • 1978
  • The purpose of this study was to evaluate the marginal sealing ability of 'Hi-Pol' Enamel Bond system. Using freshly extracted human teeth and 2% acquous methylene blue, the marginal leakage of dye in restorative materials such as 'Hi-Pol' Enamel Bond system, Hi-Pol, Adaptic, Nuva system, Epolite and Amalgam were investigated at 37℃ and under temperature cycling in range of 4℃-60℃. the results as follows; 1. All filling materials showed some degree of marginal penetration by 2% methylene blue dye. 2. 'Hi-Pol' Enamel Bond system revealed the least marginal penetration by 2% methylene blue as Nuva did at 37℃, but under temperature cycling in range of 4℃-60℃ it showed the greatest marginal penetration. 3. Hi-Pol restoration showed a tendency the similar to the other composite restoration. 4. Nuva system had the most effective marginal sealing ability either at 37℃ and under temperature cycling.

  • PDF

Effects of Material Modulus on Fracture Toughness of Human Enamel, a Natural Biocomposite

  • Mishra, Dhaneshwar;Yoo, Seung-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.3
    • /
    • pp.287-293
    • /
    • 2011
  • The enamel, the upper layer of a tooth has remarkable capability of bearing severe loading on the tooth. The fracture behavior is important to understand the mechanism of load bearing and it could be very useful for developing new materials. Non-destructive evaluation of such materials will also benefit from this knowledge. The graded microstructures of enamel were modeled by finite element analysis software and the J-integrals and the stress intensity factors were evaluated as the fracture parameters. The results show that these parameters are location dependent. Those values increase when measured in the direction of dentine enamel junction. This finding matched well with experiments and implies many useful understanding of biomaterials and applications to new materials.

Surface change of enamel according to application time of 35% Carbamide Peroxide (35% Carbamide Peroxide gel의 적용시간에 따른 법랑질 변화)

  • Lee, Hye-Jin;Kim, Min-Young;Han, Myeong-Suk
    • Journal of Korean society of Dental Hygiene
    • /
    • v.8 no.4
    • /
    • pp.11-18
    • /
    • 2008
  • The purposes of this study were to examine the effect of 35% Carbamide Peroxide(CP) bleaching agent on the changes in physical and chemical characteristics of tooth. The effect of bleaching agent on enamel was analyzed using Hardness test, SEM and EDS. The microhardness between bleached groups after bleaching showed statistically significant difference according to the paired t-test. The bleached enamel surface showed apparent morphological changes compared to the enamel, which was stored in distilled water only. The difference of the total mineral contents for the distilled water and Carbamide Peroxide did not show statistical significance. These results demonstrated that bleaching using 35% Carbamide Peroxide were adversely affects application time of experimental group and may the safety of using these agents for a short time in dentist-monitored bleaching.

  • PDF

Subepithelial connective tissue graft in combination with enamel matrix derivative for root coverage within different case of gingival recession: Case report (법랑기질유도체와 결합조직이식술을 이용한 치근피개술: 치은퇴축과 관련된 다양한 증례)

  • Lee, Jae-Hong
    • The Journal of the Korean dental association
    • /
    • v.55 no.3
    • /
    • pp.230-239
    • /
    • 2017
  • Root coverage can be an efficacious treatment not only in aspect of dental symptoms like root caries and hypersensitivity, but also in aspect of esthetic problem. There are several predictable methods for gaining a connective tissue attachment to an exposed root surface. Among them, this case report will deal with three cases using enamel matrix derivative and connective tissue graft to recover esthetic and physiological periodontal environment and its form. This case report deals with three patients with gingival recession which has occurred by different causes. They were treated with de-epithelialized graft accompanied by application of enamel matrix derivative. 6-12 months later, all three patients showed considerable root coverage and clinically stable condition of healing. In conclusion, within the limitation of this study, de-epithelialized connective tissue graft accompanied by application of enamel matrix derivative shows stable and clinical acceptable results in aspect of root coverage.

  • PDF

Optical and Mechanical Properties of Commercial Dental Enamel Porcelain (상용 치과 법랑질 도재의 광학적 및 기계적 특성)

  • Park, Hyung-Rang
    • Journal of Technologic Dentistry
    • /
    • v.26 no.1
    • /
    • pp.115-128
    • /
    • 2004
  • In this study, optical and mechanical properties were investigated with 4 kinds of commercial dental enamels. As a result of EDS analysis $SiO_2,\;Na_{2}O,\;Al_{2}O_3\;and\;K_{2}O$ were the main components of commercial dental enamels. In case of H specimen, content of $SiO_2\;and\;K_2O$ were more than that of another specimens. Starting powder and fired specimens were glass ceramics which were consist of amorphous phase and leucite (crystalline) phase. Crystallization did not occurred during firing process, since the XRD peak intensity was similar between starting powder and fired specimens. As a result of differential thermal analysis, $T_g$ and crystalline temperature was varied with composition in the range of $548\sim576^{\circ}C$ and $735\sim780^{\circ}C$ respectively. 0.5mm thickness dental enamel specimens showed sufficient translucent properties. However, transmittance and reflectance were lower than 5% result from scattering due to the refractive index difference between glass and crystalline phase. 3 point bending strength was in the range of 73.9$\sim$101.8MPa which was similar or slightly higher than enamel of natural teeth and Vickers hardness was higher than enamel of natural teeth more than 100.

  • PDF

Composition-property Relationships of Enamel Glass for Low Carbon Steel

  • Kang, Eun-Tae;Kim, Jong-Po;Cho, Yong-Hyun;Park, Seon-Mi
    • Journal of the Korean Ceramic Society
    • /
    • v.50 no.3
    • /
    • pp.186-194
    • /
    • 2013
  • The relationship between composition and properties of enamel glass was investigated by introducing a mixture design. The enamel glass was manufactured by mixing various components under the following constraints: $45{\leq}SiO_2{\leq}55$, $10{\leq}B_2O_3{\leq}18$, $6{\leq}Na_2O{\leq}15$, $1{\leq}Li_2O{\leq}6$, $5{\leq}K_2O{\leq}10$, $0{\leq}TiO_2{\leq}8$, $0{\leq}ZrO_2{\leq}8$, 13.3MO (mol %). A mathematical model for the calculation of some properties of enamel glasses as a function of their composition was developed by the experimental statistical method. The results showed that the proposed model with the experimental measurement were in good agreement and the mixture experimental design was an effective method for optimizing the composition of the enamel glass with respect to its properties.

A STUDY OF THE INFLUENCES OF ACIDIC BEVERAGES ON EROSION OF ENAMEL AND DENTIN (수종 음료수의 법랑질과 상아질 침식에 관한 연구)

  • Jang, Ki-Taeg
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.24 no.4
    • /
    • pp.719-726
    • /
    • 1997
  • The aim of this study was to evaluate the in vitro effects of exposure to acidic beverages on microhardness of enamel and dentin. Thirty enamel specimens and thirty dentin specimens were obtained from extracted bovine maxillay incisiors. Enamel and dentin specimens were divided into three groups and treated with acidic beverages as follows; Group 1 : cola(pH 2.52), Group 2 : plain soda water(pH 2.93) and Group 3 : orange juice(pH 3.75). Erosive treatment was performed by storing each specimens for 5 min in 50ml solution of cola, soda water and orange juice. Average microhardness values(VHN) were determined before and after erosive treatment. All beverages produced significant loss of microhardness of enamel and dentin. Microhardness of enamel was reduced in the following order: Group 1 : $42.71{\pm}4.36(%)$, Group 2 : $37.09{\pm}6.25(%)$, Group 3 : $35.46{\pm}4.98(%)$. Microhardness of dentin was reduced in the following order: Group 1 : $17.14{\pm}3.42(%)$, Group 2 : $13.89{\pm}3.18(%)$, Group 3 : $13.82{\pm}3.50(%)$. The differences between group 1 and group 2, 3 were statistically significant(p< 0.05).

  • PDF