A STUDY ON FORMING PATTERN OF ENAMEL IN WHITE RAT INCISOR (백서 전치의 법랑질형성 양상에 관한 주사현미경적 연구)

  • Min, Hyo-Kie
    • Restorative Dentistry and Endodontics
    • /
    • v.12 no.2
    • /
    • pp.91-98
    • /
    • 1987
  • This study was designed to investigate the changing depositional pattern of inorganic enamel substances during enamel formation and maturation. For this purpose, white rat incisors which continuously grow and develop during the life, were chosen as specimens. And after treated with 20% KOH solution, outer surface of forming inorganic enamel were observed with the scanning electron microscope, dividing into 6 types according to the forming pattern from apical to cuspal direction. The observations lead to the following conclusions: 1. During the initial enamel forming stage, inorganic enamel substances were deposited with very irregular pyramidal shape on the root dentin surface. 2. During the enamel forming stage, inorganic enamel substances were deposited with relatively regular hexagonal, honey-comb appearance. 3. During the later enamel forming stage, inorganic enamel substances were deposited with very irregular and roughly amorphous appearance. 4. During the later enamel maturating stage, very small and round inorganic enamel substances were deposited densely, and made a flat enamel surface.

  • PDF

Comparative scanning electron microscope analysis of the enamel of permanent human, bovine and porcine teeth

  • Olek, Aneta;Klimek, Leszek;Boltacz-Rzepkowska, Elzbieta
    • Journal of Veterinary Science
    • /
    • v.21 no.6
    • /
    • pp.83.1-83.14
    • /
    • 2020
  • Background: Bovine and porcine teeth are often used in in vitro experiments as substitutes of human teeth. Objectives: The aim of the present study was to perform a comparative analysis of enamel morphology of permanent human, bovine and porcine teeth under the scanning electron microscope. Methods: As many as 10 human, 10 bovine, and 10 porcine teeth were studied. All the teeth were sectioned and the halves were randomly divided into 2 groups according to the examined tissue (vestibular enamel at the mid-height of the dental crown and in the cervical area). Human and bovine enamel was etched for 15 sec and porcine enamel for 30 sec. The scanning electron microscope analysis was performed. The length and width of enamel prisms were determined with the "Met-Ilo" 1.1 computer program. Results: All enamel samples revealed the same etching pattern-Silverstone's type 2. Bovine enamel showed a similar porosity and the amount of interprismatic enamel compared to human enamel while the amount and width of interprismatic enamel bands in porcine enamel were evidently greater. The shape of the porcine prisms was visually similar to human prisms, although dimensions were significantly different. However, bovine prisms differed in form and appeared to be distinctly elongated. Conclusions: Reported findings indicate that the results of experimental studies carried out on bovine and porcine enamel should not be compared with the results obtained on human enamel.

A STUDY ON THE EFFECT OF DENTIN BONDING AGENTS APPLIED OVER ENAMEL ABOUT THE BOND STRENGTH OF COMPOSITE RESIN (접착강화제가 치아경조직과의 접착강도 변화에 미치는 영향에 관한 연구)

  • Choi, Woong-Dae;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.1
    • /
    • pp.1-16
    • /
    • 1995
  • The purpose of this study was to investigate the effect of dentin bonding agents on the bond strength of composite resin restorations in case of applying the dentin bonding agents to acid etched enamel surfaces. Freshly extracted 364 bovine anterior teeth were selected as a adherents. 320 enamel specimens were divided into two groups(unetched group (1) and etched group (2) for testing the shear bond strength, 40 specimens were used for the hardness testing, and 4 specimens of rest were to observe the resin-tag formation into etched enamel surfaces. All surfaces of enamel specimens were polished with 320~1500 SiC paper under continuous running water. In Group (1), 100 enamel specimens were polished and unetched. 220 polished enamel specimens in Group (2) were etched with 37 % phosphoric acid solution for 60 seconds, washed with water for 20 seconds, and dried with a light air pressure for 60 seconds. Three kinds of dentin bonding agents(Gluma, Prisma, Scotchbond 2) were evaluated the effect on the bond strength to conditioned enamel surfaces. Shear bond strengths were measured on the three cases such as a coating of primer only, a coating of sealer only, and a sequential coating of primer and sealer to acid etched enamel surfaces were compared with the bond strengths measured by the coating of enamel bonding agent followed by the bonding of composite resin (Photo clearfil bright, Kuraray, Japan) to unetched and acid etched enamel surfaces. In addition, the hardness tested on the adhesive fractured surface between composite resin enamel as a mean of evaluation of a factor whether the mechanical bond strengths were affected and the penetration of dentin bonding agents into etched enamel surfaces was also observed. Bond strengths were measured using the method of shear bond strength by a universal testing machine (Instron-4467, USA), statistical test were applied to the results using a one way analysis variance(ANOVA), and hardness was measured by the Vicker's Hardness Tester(MHT-i, Matsuzawa, Japan) and the penetration of the resins were observed by the SEM (Hitachi, S-2300, Japan). The following conclusions were drawn; 1. Enamel bonding agent showed to affect the improvement of bond strength of composite resin to enamel surface both unetched and etched. 2. Dentin bonding agents could be resulted in increase of bond strength to unetched enamel surface, but there were no statistical significances. 3. Bond strengths to etched enamel surface were significantly decreased with a coating of dentin primer only. 4. Coating of sealer only and coating of primer and sealer noticed the similar bond strengths of composite resin to etched enamel using the enamel bonding agents. 5. The applying method proved to be more effective than the kinds of dentin bonding agents on the bond strength of composite resin to etched enamel than the kind of dentin. 6. Vicker's hardness numbers of dentin bonding agents were lower than that of composite resin, but the degree of penetration of dentin bonding agents into etched enamel surfaces was excellent.

  • PDF

Analysis on Enameled Container with Different Coating Thicknesses of Enamel in Pyrolysis Process (법랑공정에서 Enamel 도포두께에 따른 강판 용기의 변형 메커니즘 분석)

  • Park, Sang-Hu;Kang, Dong-Suk;Yu, Jae-Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.5
    • /
    • pp.67-74
    • /
    • 2020
  • To predict the thermal deformation of an oven cabinet during the enamel process, we propose a simple finite element analysis method comprising two steps: heating and cooling. To this end, the basic mechanical and thermal properties such as thermal expansion of the enamel and steel plate were experimentally studied, and the mechanical properties of four different stainless steel (SUS) plates were evaluated to select the target material for the oven at high temperature conditions from 400 ℃ to 700 ℃. In the first analysis step of the enamel process, the SUS plate was heated to 850 ℃ and was then thermally expanded without considering the enamel coating. Next, assuming the perfect bonding of two materials (enamel coating and metal plate), the enamel plate was allowed to cool to room temperature till 22 ℃. From the results of comparing the experimental and analytical data, we can make a conclusion that the proposed method can be applied to evaluate the thermal deformation of enamel products. Especially, the thermal deformation of the oven can be predicted with different enamel coating conditions, such as uniform and nonuniform coating thickness.

A SHEAR BOND STRENGTH OF RESIN CEMENT BONDED TO HUMAN UNCUT ENAMEL, CUT ENAMEL, AND DENTIN IN VITRO

  • Lee Jong-Yeop
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.3
    • /
    • pp.319-324
    • /
    • 2003
  • Statement of problem. Adhesives in dentistry playa major role in the success of restorative treatments. In the treatment of all ceramic restoration it is needed to find the adequate bond strength between enamel and dentin. Purpose. The purpose of this study was to evaluate shear bond strength of resin cement bonded to extracted human uncut enamel, cut enamel, and dentin in vitro. Material and methods. Ten freshly extracted anterior teeth without any previous restorative treatments were chosen. The extracted teeth were embedded in PMMA cold acrylic in the shape of a cylinder, 25 mm in diameter by 25 mm in height. The bonding system used was as follow: Uni-Etch (32% phosphoric acid), One-Step adhesive, Duolink resin cement. The specimens were acid etched and rinsed with water. Two layers of One-Step adhesive were coated with a disposable brush on the uncut enamel. VIP curing light at $500mV/cm^2$ was used to cure the adhesive. For cut enamel shear bond test, the specimen used for uncut enamel was further reduced approximately $0.3{\sim}0.5mm$ using a laminate preparation diamond bur (0.3 mm in depth). The specimens were subsequently treated with 320-grit SiC paper followed by 600-grit SiC paper and cleaned with distilled water. The bonding procedure on the cut enamel was same as uncut enamel bonding procedure. For dentin bonding test, the specimen used for cut enamel was further reduced approximately $0.5mm{\sim}1.0mm$ using a laminate preparation diamond bur (0.5 mm in depth of diamond cutting). The amount of reduction was evaluated with the silicone mold. The specimens were subsequently treated with 320-grit SiC paper followed by 600-grit silicon carbon paper and cleaned in distilled water. The bonding procedure on the dentin was same as uncut enamel bonding procedure. All samples were mounted and secured on the Ultradent shear bond test sample holder, and Ultradent restricted shear bond testing device was used with Universal Instron machine until fracture. Analysis of variance (ANOVA) test was performed comparing the result at P<0.05. Multiple comparison (Tukey) was used to compare each groups. Result. The result showed that the mean value in shear bond strength of resin cement bonded to uncut enamel, cut enamel and dentin were 27.04 Mpa, 30.25 Mpa and 26.39 Mpa with respect. Conclusion. Within the limitation of this study, the mean value of the shear bond strength of cut enamel was higher than those of uncut enamel or dentin. However there existed no statistical differences between three different human dentition substrates due to increased adhesive characteristics.

3D quantitative analysis and SEM qualitative analysis of natural antagonist enamel opposing CAD-CAM monolithic zirconia or lithium disilicate tooth-supported crowns versus enamel opposing natural enamel

  • Piyarat Woraganjanaboon;Chuchai Anunmana
    • The Journal of Advanced Prosthodontics
    • /
    • v.16 no.1
    • /
    • pp.12-24
    • /
    • 2024
  • PURPOSE. This study aimed to evaluate the maximum vertical wear, volume wear, and surface characteristic of antagonist enamel, opposing monolithic zirconia or lithium disilicate crowns. MATERIALS AND METHODS. The study comprised 24 participants (n = 12), who were randomly allocated to receive either a 5 mol% Y-TZP or a lithium disilicate crown in positions which would oppose the natural first molar tooth. The contralateral first molar along with its antagonist was considered as the enamel opposing natural enamel control. Data collection was performed using an intraoral scanner and polyvinylsiloxane impression. The means of the maximum vertical loss and the volume loss at the occlusal contact areas of the crowns and the various natural antagonists were measured by 3D comparison software. A scanning electron microscope was subsequently used to assess the wear characteristics. RESULTS. The one-year results from 22 participants (n = 11) indicated no significant differences when comparing the zirconia crown's antagonist enamel (40.28 ± 9.11 ㎛, 0.04 ± 0.02 mm3) and the natural enamel wear (38.91 ± 7.09 ㎛, 0.04 ± 0.02 mm3) (P > .05). Also, there is no significant differences between lithium disilicate crown's antagonist enamel (47.81 ± 9.41 ㎛, 0.04 ± 0.02 mm3) and the natural enamel wear (39.11 ± 7.90 ㎛, 0.04 ± 0.02 mm3) (P > .05). CONCLUSION. While some studies suggested that monolithic zirconia caused less wear on opposing enamel than lithium disilicate, this study found similar wear levels to enamel for both materials compared to natural teeth.

A Study on the Colors of Enamel Wear (법랑 재료의 혼합에 따른 색상 변화에 대한 연구)

  • 한두희
    • Proceedings of the KAIS Fall Conference
    • /
    • 2002.05a
    • /
    • pp.197-199
    • /
    • 2002
  • Samples of enamel wear for kitchen works were made at the Kordco Enamel Co. We analyzed the colors of enamel wears with Color Meter (JS555). The colors of enamel wears could be controled by mixing ratio of frits and pigments. Many kinds of frits and pigments were tested, and colors of enamel wears could be changed by variable frits. Colors were weakly changed by several mixing ratio of pigments.

OBSERVATION WITH SCANNING ELECTRON MICROSCOPE ON THE EFFECT OF THREE DENTAL ETCHANTS IN THE ENAMEL SURFACE OF ALBINO RATS (치과용 부식제가 백서 법랑질 표면에 미치는 영향에 대한 주사전자현미경적 관찰)

  • Kwon, Taik-Kyun
    • Restorative Dentistry and Endodontics
    • /
    • v.6 no.1
    • /
    • pp.133-139
    • /
    • 1980
  • In this experiment, etching was performed on the incisor enamel surfaces of 13 Albino rats, weighted about 130gm, with both 30% and 50% concentrations of the phosphoric, citric acids, and EDTA solution for 60 seconds. Immediately after extraction of the animal teeth, laboratory procedures for scanning electron microscopic observations were made and the author derived the following conclusions: 1. On the enamel surface treated with 30% and 50% phosphoric acids, all of the periphery, center of the enamel rods, and the enamel matrices were severely etched. 2. In the etched with 30% citric acid group, only the small part of the enamel rods were etched out. In case of 50% citric acid the periphery, center of enamel rods were partially or entirely etched, and the intermatrix spaces were widened. 3. In the 30% and 50% of the EDTA etched groups, the periphery of the enamel rods explicitely were etched, and the spaces between matrices were widened.

  • PDF

A Study on the Colors of Enamel Wear by Changing the Ratio of Frit, Clay and Pigments (프리트, 점토 및 안료의 혼합에 따른 법랑 색상에 관한 연구)

  • 한두희;이정화
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.3 no.2
    • /
    • pp.101-109
    • /
    • 2002
  • Samples of enamel wear for kitchen works were made at the Kordco Enamel Co. We analyzed the colors of enamel wears with Color Meter (JS555). The colors of enamel wears could be controled by mixing ratio of frits and pigments. Many kinds of frits and pigments were tested, and colors of enamel wears could be changed by variable frits. Colors were weakly changed by several mixing ratio of pigments.

  • PDF

AN EXPERIMENTAL STUDY ON THE BONDING STRENGTH OF COMPOSITE RESINS TO ETCHED ENAMEL SURFACE WITH PHOSPHORIC ACID (산처리(酸處理)된 치아표면(齒牙表面)에 대(對)한 복합(複合)레진 접착강도(接着强度)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Park, Kyung-Jung
    • Restorative Dentistry and Endodontics
    • /
    • v.5 no.1
    • /
    • pp.19-23
    • /
    • 1979
  • This experimental study was made to investigate the tensile strength of composite resins to etched enamel surface with a 50% phosphoric acid. Recently extraced 40 maxillary incisors were chosen. These were divied into 4 groups: Group I: Restodent adaptation to the etched enamel surface with 50% phosphoric acid. Group II: Restodent adaptation to only the ground enamel surface. Group III: Hi-pol adaptation to the etched enamel surface with 50% phosphoric acid. Group IV: Hi-pol adaptation to only the ground enamel surface. The results were as follows: 1. The tensile strength of Hi-pol showed much better results than that of Restodent. 2. Hi-pol and Restodent on the ground enamel surfaces showed little difference. 3. Adhesion to enamel increased on the average over 200% after a 50% phosphoric acid etch.

  • PDF