• Title/Summary/Keyword: emission test

Search Result 1,624, Processing Time 0.032 seconds

A Study on Dose Assessment by 18F-FDG injected into Patients (환자에게 주입된 18F-FDG 의한 선량 평가에 대한 연구)

  • Kim, Chang-Ju;Kim, Jang-Oh;Jeong, Geun-Woo;Shin, Ji-Hey;Lee, Ji-Eun;Jeon, Chan-Hee;Min, Byung-In
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.467-475
    • /
    • 2020
  • The purpose of this study is to assess doses to 18F-FDG, a radioactive drug, during PET examinations, to alleviate anxiety about radiation in patients and carers, to minimize the indiscriminate examination progress caused by medical institution personnel and space clearance problems, and health examination. The dose assessment was measured using a thermo-fluorescent dosimeter (TLD) and an electronic personal dosimeter (EPD) at the location of the cervical (hypothyroid), thorax (heart), and lower abdomen (breeding line) which are the three highest tissue areas of the radiation tissue weighting. In addition, spatial dose rates and radioactivity in urine were measured using GM counters and ion boxes. The results are as follows: First, the personal dosimeter TLD was measured 0.0425±0.0277 mSv in the cervical region, 0.0440±0.0386 mSv in the thorax and 0.0485±0.0436 mSv in the lower abdomen, with little difference in the heart dose depending on radiation sensitivity. The EPD was measured at 0.942±0.141 mSv/h immediately after the cervical position, and 0.192±0.031 mSv/h after 120 minutes. Immediately after the thorax position, 0.516±0.085 mSv/h, 120 minutes later 0.128±0.040 mSv/h. Immediately after the lower abdomen position, 0.468±0.091 mSv/h, and after 120 minutes 0.105±0.021 mSv/h were measured. The spatial dose rate at the GM counter was measured immediately at 0.041±0.005 mSv/h, 120 minutes later at 0.014±0.002 mSv/h. The radioactivity in urine using ion chamber was measured at 0.113±0.24 MBq/cc after 60 minutes and 0.063±0.13 MBq/cc after 120 minutes. As a result, 18F-FDG should be administered, dose re-evaluated two hours after the PET test is completed, and caregivers should be avoided. In addition, it is deemed necessary to provide patients and carers with sufficient explanations and expected values of exposure dose to avoid reckless testing. It is hoped that the data tested in this study will help patients and families relieve anxiety about radiation, and that the radiation workers' exposure management system and institutional improvements will contribute to the development of medical radiation.

PREPARATION OF AMORPHOUS CARBON NITRIDE FILMS AND DLC FILMS BY SHIELDED ARC ION PLATING AND THEIR TRIBOLOGICAL PROPERTIES

  • Takai, Osamu
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.3-4
    • /
    • 2000
  • Many researchers are interested in the synthesis and characterization of carbon nitride and diamond-like carbon (DLq because they show excellent mechanical properties such as low friction and high wear resistance and excellent electrical properties such as controllable electical resistivity and good field electron emission. We have deposited amorphous carbon nitride (a-C:N) thin films and DLC thin films by shielded arc ion plating (SAIP) and evaluated the structural and tribological properties. The application of appropriate negative bias on substrates is effective to increase the film hardness and wear resistance. This paper reports on the deposition and tribological OLC films in relation to the substrate bias voltage (Vs). films are compared with those of the OLC films. A high purity sintered graphite target was mounted on a cathode as a carbon source. Nitrogen or argon was introduced into a deposition chamber through each mass flow controller. After the initiation of an arc plasma at 60 A and 1 Pa, the target surface was heated and evaporated by the plasma. Carbon atoms and clusters evaporated from the target were ionized partially and reacted with activated nitrogen species, and a carbon nitride film was deposited onto a Si (100) substrate when we used nitrogen as a reactant gas. The surface of the growing film also reacted with activated nitrogen species. Carbon macropartic1es (0.1 -100 maicro-m) evaporated from the target at the same time were not ionized and did not react fully with nitrogen species. These macroparticles interfered with the formation of the carbon nitride film. Therefore we set a shielding plate made of stainless steel between the target and the substrate to trap the macropartic1es. This shielding method is very effective to prepare smooth a-CN films. We, therefore, call this method "shielded arc ion plating (SAIP)". For the deposition of DLC films we used argon instead of nitrogen. Films of about 150 nm in thickness were deposited onto Si substrates. Their structures, chemical compositions and chemical bonding states were analyzed by using X-ray diffraction, Raman spectroscopy, X-ray photoelectron spectroscopy and infrared spectroscopy. Hardness of the films was measured with a nanointender interfaced with an atomic force microscope (AFM). A Berkovich-type diamond tip whose radius was less than 100 nm was used for the measurement. A force-displacement curve of each film was measured at a peak load force of 250 maicro-N. Load, hold and unload times for each indentation were 2.5, 0 and 2.5 s, respectively. Hardness of each film was determined from five force-displacement curves. Wear resistance of the films was analyzed as follows. First, each film surface was scanned with the diamond tip at a constant load force of 20 maicro-N. The tip scanning was repeated 30 times in a 1 urn-square region with 512 lines at a scanning rate of 2 um/ s. After this tip-scanning, the film surface was observed in the AFM mode at a constant force of 5 maicro-N with the same Berkovich-type tip. The hardness of a-CN films was less dependent on Vs. The hardness of the film deposited at Vs=O V in a nitrogen plasma was about 10 GPa and almost similar to that of Si. It slightly increased to 12 - 15 GPa when a bias voltage of -100 - -500 V was applied to the substrate with showing its maximum at Vs=-300 V. The film deposited at Vs=O V was least wear resistant which was consistent with its lowest hardness. The biased films became more wear resistant. Particularly the film deposited at Vs=-300 V showed remarkable wear resistance. Its wear depth was too shallow to be measured with AFM. On the other hand, the DLC film, deposited at Vs=-l00 V in an argon plasma, whose hardness was 35 GPa was obviously worn under the same wear test conditions. The a-C:N films show higher wear resistance than DLC films and are useful for wear resistant coatings on various mechanical and electronic parts.nic parts.

  • PDF

The Chemistry and Origin of Amphibolitic Rocks in the Sobaegsan Metamorphic Belt and the Ogbang and Sangdong Tungsten Mine Areas, Korea (소백산변성대(小白山變成帶)와 옥방(玉房) 및 상동중석광상내(上東重石鑛床內)의 각섬석질암(角閃石質岩)의 지화학(地化學) 및 성인(成因)에 관(關)한 연구(硏究))

  • So, Chil-Sup;Kim, Sang-Myeong
    • Economic and Environmental Geology
    • /
    • v.8 no.3
    • /
    • pp.147-164
    • /
    • 1975
  • 19 amphibolite samples from the Precambrian Sobaegsan metamorphic belt including the Ogbang mine amphibolites were analyzed for 24 elements each, by wet chemical and emission spectroscopic methods. All the chemical data were evaluated by the methods outlined by Evans and Leake(1960) and Leake(1964) and by Shaw and Kudo(1965). The chemical similarity of all the studied rocks analyzed to basic igneous rocks is consistently indicated particularly by trace element abundance and variation trends. Petrography and oxidation ratios were also considered in attempting to determine the nature of the parent rocks. 3 analyses of W-bearing mafic metamorphic rocks from Sangdong area of the Ogcheon geosynclinal zone are also presented and discussed. Geochemical data for these latter rocks have been possibly derived from mafic tuffs deposited in an area of carbonate deposition.

  • PDF

Evaluation of Myocardial Oxygen Consumption with $^{11}C$-Acetate and 3D PET/CT: By Applying Recirculation Correction Method and Modified One-Compartmental Tracer Kinetic Modeling ($^{11}C$-Acetate와 3차원 PET/CT를 이용한 심근의 산소 소모량 평가: 재순환 교정법 및 수정 단일구획 추적자 동적 모델 적용)

  • Chun, In-Kook;Hwang, Kyung-Hoon;Lee, Sang-Yoon;Kim, Jin-Su;Lee, Jae-Sung;Shin, Hee-Won;Lee, Min-Kyung;Yoon, Min-Ki;Choe, Won-Sick
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.4
    • /
    • pp.275-284
    • /
    • 2008
  • Purpose: We intended to evaluate myocardial oxygen consumption ($MVO_2)$ by applying recirculation correction and modified one-compartment model to have a reference range of $MVO_2$ in normal young population and to reveal the effect of recirculation on time-activity curve (TAC). Materials and Methods: In nine normal male volunteers with mean age of $26.3{\pm}4.0$, $MVO_2$ was estimated with 925 MBq (25mCi) of $^{11}C$-Acetate (Neuroscience Research Institute, Gachon University of Medicine and Science, Incheon, Korea) and PET/CT (Biograph 6, Siemens Medical Solution, Germany). Analysis software such as $MATLAB^{(R)}$ v7.1 (Mathworks, Inc., United States), $Excel^{(R)}$ 2007 (Microsoft, United States), and $SPSS^{(R)}$ v12.0 (Apache Software Foundation, United States) were used. Twenty three frames were of $12{\times}10$, $5{\times}60$, $3{\times}120$, $2{\times}300's$ duration, respectively. The modified one-compartmental model and the recirculation correction method were applied. Statistical analysis was performed by using Test of Normality, ANOVA and Post-Hoc (Scheffe's) analysis, and p-value less than 0.05 was considered as significant. Results: The normal reference ranges of $MVO_2$ were presented as $3.18-4.64\;{\times}\;10^{-4}\;ml/g/sec$, $1.91-3.94\;{\times}\;10^{-4}\;ml/g/sec$, $4.31-6.40\;{\times}\;10^{-4}\;ml/g/sec$, $2.84-4.53\;{\times}\;10^{-4}\;ml/g/sec$ and $3.42-5.00\;{\times}\;10^{-4}\;ml/g/sec$ in the septum, the inferior wall, the lateral wall, the anterior wall and the entire wall, respectively. In addition, it was noted that the dual exponentiality of the clearance curve is due to the recirculation effect and that the characteristic of the curve is essentially mono-exponential. Conclusion: $^{11}C$-Acetate is a radiotracer worthwhile to assess $MVO_2$. Re-circulated $^{11}C$ can influence TAC of $^{11}C$ in myocadia and so the recirculation correction must be considered when measuring $MVO_2$.

A Study on Migration of Heavy Metals from Kitchen Utensils Including Glassware, Ceramics, Enamel, Earthenware and Plastics (유리제 등 조리기구 중 중금속 이행에 관한 연구)

  • Choi, Jae-Chon;Park, Se-Jong;Goh, Hyeah;Lee, Ju Yeun;Eom, Mi Ok;Kim, Meehye
    • Journal of Food Hygiene and Safety
    • /
    • v.29 no.4
    • /
    • pp.334-339
    • /
    • 2014
  • The purpose of our study was to investigate the migration level of lead (Pb), cadmium (Cd), antimony (Sb), arsenic (As), hexavalent chromium ($Cr^{6+}$) and mercury (Hg) from cookwares into food simulants and to evaluate the safety of each heavy metals. The test articles for heavy metals were glassware, ceramics, enamel, earthenware, polypropylene and polyethylene cookwares for Pb and Cd, enamel for Sb, earthenware for As, polyethylene and polypropylene cookwares for $Cr^{6+}$ and Hg. All the article samples of 391 intended for contact with foods were purchased in domestic markets. Pb, Cd, Sb and As were analyzed by Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES), $Cr^{6+}$ by UV visible spectrophotometer and Hg by mercury analyzer. The migration levels of heavy metals in all the samples were within the migration limits of Ministry of Food and Drug Safety (MFDS). As a result of safety evaluation, our results showed that the estimated daily intakes (EDI, mg/kg bw/day) were $9.12{\times}10^{-6}$ and $8.83{\times}10^{-7}$ for Pb and Cd from ceramics and $1.19{\times}10^{-5}$, $1.23{\times}10^{-5}$ and $7.52{\times}10^{-6}$ for Pb, Cd and Sb from enamel. Tolerable daily intakes (TDI, mg/kg bw/day) were established respectively as 0.0036, 0.00081, 0.0021, and 0.0006 for Pb, Cd, As and Hg by JECFA (Joint FAO/WHO Expert Committee on Food Additives), as 0.0060 for Sb by WHO (World Health Organization). When comparing with TDIs, the EDIs accounted for 0.25% and 0.11% for Pb and Cd from ceramics and 0.33%, 1.52% and 0.13% for Pb, Cd and Sb from enamel.

A Novel Volumetric Method for Quantitation of Titanium Dioxide in Cosmetics (용량분석법을 이용한 화장품 중 티타늄옥사이드의 정량)

  • Kim, Young-So;Kim, Boo-Min;Park, Sang-Chul;Jeong, Hye-Jin;Chang, Ih-Seop
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.31 no.4 s.54
    • /
    • pp.289-293
    • /
    • 2005
  • Nowadays there are many sun protection cosmetics including organic or inorganic UV filter as an active ingredient. Chemically stable inorganic sunsEreen agents, usually metal oxides, we widely employed in high SPF products. Titanium dioxide is one of the most frequently used inorganic UV filters. It has been used as pigments for a long period of cosmetic history. With the development of micronization techniques, it becomes possible to incorporate titanium dioxide in sunscreen formulations without whitening effect and it becomes an important research topic. However, there are very few works related to quantitations of titanium dioxide in sunscreen products. In this research, we analyzed amounts of titanium dioxide in sunscreen cosmetics by adapting redof titration, reduction of Ti(IV) to Ti(III) and reoxidation to Ti(IV). After calcification of other organic ingredients of cosmetics, titanium dioxide is dissolved by hot sulfuric acid. The dissolved Ti(IV) is reduced to the Ti(III) by adding aluminum metals. The reduced Ti(III) is titrated against a standard oxidizing agent, Fe(III) (ammonium iron(III) sulfate), with potassium thiocyanate as an indicator In order to test accuracy and applicability of the proposed method, we analyzed the amounts of titanium dioxide in four types of sunscreen cosmetics, such as cream, make-up base, foundation and powder, after adding known amounts of titanium dioxide $(1{\sim}25w/w%)$. The percent recoveries of the titanium dioxide in four types of formulations were in the range between 96 and 105%. We also analyzed 7 commercial cosmetic products labeled titanium dioxide as an ingredient and compared the results with those of obtained from ICP-AES (Inductively Coupled Plasma-Atomic Emission Spectrometry), one of the most powerful atomic analysis techniques. The results showed that the titrated amounts were well coincided with the analyzed amounts of titanium dioxide by ICP-AES. Although instrumental analytical methods, ICP-MS (Inductively Coupled Plasma-Mass Spectrometry) and ICP-AES, are the best for the analysis of titanium, it is hard to adopt because of their high prices for small cosmetic companies. It was found that the volumetric method presented here gat e quantitative and reliable results with routine lab-wares and chemicals.

Analysis of the Seasonal Concentration Differences of Particulate Matter According to Land Cover of Seoul - Focusing on Forest and Urbanized Area - (서울시 토지피복에 따른 계절별 미세먼지 농도 차이 분석 - 산림과 시가화지역을 중심으로 -)

  • Choi, Tae-Young;Moon, Ho-Gyeong;Kang, Da-In;Cha, Jae-Gyu
    • Journal of Environmental Impact Assessment
    • /
    • v.27 no.6
    • /
    • pp.635-646
    • /
    • 2018
  • This study sought to identify the characteristics of seasonal concentration differences of particulate matter influenced by land cover types associated with particulate matter emission and reductions, namely forest and urbanized regions. PM10 and PM2.5 was measured with quantitative concentration in 2016 on 23 urban air monitoring stations in Seoul, classified the stations into 3 groups based on the ratio of urbanized and forest land covers within a range of 3km around station, and analysed the differences in particulate matter concentration by season. The center values for the urbanized and forest land covers by group were 53.4% and 34.6% in Group A, 61.8% and 16.5% in Group B, and 76.3% and 6.7% in Group C. The group-specific concentration of PM10 and PM2.5 by season indicated that the concentration of Group A, with high ratio of forests, was the lowest in all seasons, and the concentration of Group C, with high ratio of urbanized regions, had the highest concentration from spring to autumn. These inter-group differences were statistically significant. The concentration of Group C was lower than Group B in the winter; however, the differences between Groups B to C in the winter were not statistically significant. Group A concentration compared to the high-concentration groups by season was lower by 8.5%, 11.2%, 8.0%, 6.8% for PM10 in the order of spring, summer, autumn and winter, and 3.5%, 10.0%, 4.1% and 3.3% for PM2.5. The inter-group concentration differences for both PM10 and PM2.5 were the highest in the summer and grew smaller in the winter, this was thought to be because the forests' ability to reduce particulate matter emissions was the most pronounced during the summer and the least pronounced during the winter. The influence of urbanized areas on particulate matter concentration was lower compared to the influence of forests. This study provided evidence that the particulate matter concentration was lower for regions with higher ratios of forests, and subsequent studies are required to identify the role of green space to manage particulate matter concentration in cities.

Evaluation of the influence of a visual design of an examination guide on patient comprehension and testing accuracy (검사 안내문의 시각적 디자인화가 환자의 검사 이해도 및 정확성에 미치는 영향 평가)

  • Kang, Young-Eun;Jung, Woo-Young;Hong, Bo-Ruem
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.29-34
    • /
    • 2019
  • Purpose An examination guide is a useful medium to provide the patient with an overview, pre- and post-test preparation, and precautions of nuclear testing. The design and arrangement of existing written texts and announcements were evaluated to elucidate the comprehension of patients undergoing testing. Materials and Methods Informational material describing bone scanning and $^{201}thallium$ myocardium perfusion single-photon emission computed tomography (SPECT), as a secondary examination, which accounts for the largest portion of gamma imaging at Asan Hospital (Seoul, South Korea), was selected as an improvement target in consultation with a national innovation center. Existing informational material was dispensed to patients scheduled for bone scans from November 2016 to February 2017 and the revised material was issued from March 2017 to May 2017. A survey was conducted of 200 patients who underwent $^{201}thallium$ myocardium perfusion SPECT before and after the revisions (n = 100 each time period) to assess the patients' understanding of the informational material. Results When comparing the use of the conventional vs. revised material, the number of patients who received treatment before bone scanning had decreased from 130 to 60, while the number of those who required additional imaging decreased from 53 to 14. Prior to the revision, 43% of patients underwent testing before preparation and 18% underwent additional testing. The decreased need for additional image acquisition after revision of the informational material resulted in a decrease in acquisition time of about 2 min, from 16.5 to 14.2 min. In the case of $^{201}thallium$ myocardium perfusion SPECT, patient comprehension of all five items surveyed had increased, while the number of patients who had repeatedly asked about various facets of the procedure pre- and post-testing had decreased from 36% to 16% and 31% to 14%, respectively. Conclusion Lower patient comprehension is accompanied by a decrease in image quality due to non-compliance during pre-testing and may lead to repetitive questions from the patient, which may also negatively affect the fatigue and work efficiency of the examiner. Improved readability and visibility of informational material through visualization was correlated with greater patient comprehension as well as improved image quality and acquisition time.

Air-staging Effect for NOx Reduction in Circulating Fluidized Bed Combustion of Domestic Unused Biomass (국내 미이용 바이오매스 순환유동층 연소에서 NOx 저감을 위한 air-staging 효과)

  • Yoon, Sang-Hee;Beak, Geon-Uk;Moon, Ji-Hong;Jo, Sung-Ho;Park, Sung-Jin;Kim, Jae-Young;Seo, Myung-Won;Yoon, Sang-Jun;Yoon, Sung-Min;Lee, Jae-Goo;Kim, Joo-Sik;Mun, Tae-Young
    • Korean Chemical Engineering Research
    • /
    • v.59 no.1
    • /
    • pp.127-137
    • /
    • 2021
  • Air emission charge for nitrogen oxide as a precursor of fine dust has been introduced and implemented within the country from 2020. Therefore, the development of economical combustion technology for NOx reduction has got more needed urgently. This study investigated the air-staging effect as a way to reduce the NOx during combustion of domestic unused forest biomass, recently possible to secure REC (Renewable Energy Certification) as a substitute for overseas wood pellets in a 0.1 MWth circulating fluidized bed combustion test-rig. Operating conditions were comparison with and without air-staging, the supply position of tertiary air (6.4 m, 8.1 m, 9.4 m in the combustor) and variation of air-staging ratio (Primary air:Secondary air:Tertiary air=91%:9%:0%, 82%:9%:9%, 73%:9%:18%). NO and CO concentrations in flue gas, profiles of temperature and pressure at the height of the combustion, unburned carbon in sampled fly ash and combustion efficiency on operating conditions were evaluated. As notable results, NO concentration with air-staging application under tertiary air supply at 9.4 m in the combustor reduced 100.7 ppm compared to 148.8 ppm without air-staging while, CO concentration increased from 52.2 ppm without air-staging to 99.8 ppm with air-staging. However, among air-staging runs, when tertiary air supply amount at 6.4 m in the combustor increased by air-staging ratio (Primary air:Secondary air:Tertiary air=73%:9%:18%), NO and CO concentrations decreased the lowest 90.8 ppm and 66.1 ppm, respectively. Furthermore, combustion efficiency at this condition was improved to 99.3%, higher than that (98.3%) of run without air-staging.

Characteristics of Flue Gas Using Direct Combustion of VOC and Ammonia (휘발성 유기 화합물 및 암모니아 직접 연소를 통한 배기가스 특성)

  • Kim, JongSu;Choi, SeukCheun;Jeong, SooHwa;Mock, ChinSung;Kim, DooBoem
    • Clean Technology
    • /
    • v.28 no.2
    • /
    • pp.131-137
    • /
    • 2022
  • The semiconductor process currently emits various by-products and unused gases. Emissions containing pollutants are generally classified into categories such as organic, acid, alkali, thermal, and cabinet exhaust. They are discharged after treatment in an atmospheric prevention facility suitable for each exhaust type. The main components of organic exhaust are volatile organic compounds (VOC), which is a generic term for oxygen-containing hydrocarbons, sulfur-containing hydrocarbons, and volatile hydrocarbons, while the main components of alkali exhaust include ammonia and tetramethylammonium hydroxide. The purpose of this study was to determine the combustion characteristics and analyze the NOX reduction rate by maintaining a direct combustion and temperature to process organic and alkaline exhaust gases simultaneously. Acetone, isopropyl alcohol (IPA), and propylene glycol methyl ether acetate (PGMEA) were used as VOCs and ammonia was used as an alkali exhaust material. Independent and VOC-ammonia mixture combustion tests were conducted for each material. The combustion tests for the VOCs confirmed that complete combustion occurred at an equivalence ratio of 1.4. In the ammonia combustion test, the NOX concentration decreased at a lower equivalence ratio. In the co-combustion of VOC and ammonia, NO was dominant in the NOX emission while NO2 was detected at approximately 10 ppm. Overall, the concentration of nitrogen oxide decreased due to the activation of the oxidation reaction as the reaction temperature increased. On the other hand, the concentration of carbon dioxide increased. Flameless combustion with an electric heat source achieved successful combustion of VOC and ammonia. This technology is expected to have advantages in cost and compactness compared to existing organic and alkaline treatment systems applied separately.