• 제목/요약/키워드: emission decay model

검색결과 30건 처리시간 0.027초

구획모델을 이용한 주택에서 이산화질소의 발생강도 및 감소상수 동시 추정 (Estimation of Source Strength and Deposition Constant of Nitrogen Dioxide Using Compartment Model)

  • 양원호;손부순;손종렬
    • 한국환경보건학회지
    • /
    • 제31권4호
    • /
    • pp.260-265
    • /
    • 2005
  • Indoor air quality might be affected by source strength of indoor pollutants, ventilation rate, decay rate, outdoor level, and so on. Although technologies measuring these factors exist directly, direct measurements of all factors are not always practical in most field studies. The purpose of this study was to develop an alternative method to estimate the source strength and deposition constant by application of multiple measurements. For the total duration of 60 days, indoor and outdoor $NO_2$ concentrations every 3 days were measured in 30 houses in Seoul, Asan and Daegu. Using a compartment model by mass balance and linear regression analysis, penetration factor (ventilation divided by sum of air exchange rate and deposition constant) and source strength factor (emission rate divided by sum of air exchange rate and deposition constant) were calculated. Subsequently, the source strength and deposition constant were estimated. Natural ventilation was $1.80{\pm}0.42\;ACH,\;1.11{\pm}0.50\;ACH,\;0.92{\pm}0.26\;ACH$ in Seoul, Asan and Daegu, respectively. Calculated deposition constant(K) and source strength of $NO_2,$ in this study were $0.98{\pm}0.28\;hr^{1}\;and\;16.28{\pm}7.47\;ppb/h,$ respectively.

금호강 유역에서의 4-nitrophenol 배출 특성과 오염원 기여도 모의 연구 (Study on the simulation of emission characteristics and sources contribution of 4-nitrophenol in the Geumho River)

  • 박경덕;양득석;이인정;김일규
    • 상하수도학회지
    • /
    • 제33권1호
    • /
    • pp.43-53
    • /
    • 2019
  • In the Geumho River, 4-nitrophenol has been detected, thus it is necessary to investigate the contamination sources in order to prevent the release of this compound. However, the research to estimate the potential source is regarded as complicated research. In this study, the distributions of 4-nitrophenol were simulated and the contribution of the potential sources was estimated using a numerical model(HydroGeoSphere; HGS) and the measuring data of 4-nitrophenol from 2013 to 2017. The altitude data, the land cover data, the flow rates of the tributaries and wastewater treatment plants, and the decay rate of 4-nitrophenol was used as the input data. The results of this research showed that the contribution rates of potential contamination sources in the upstream area were higher than that of the downstream area. Most of the upstream area is the agricultural area, it seemed that 4-nitrophenol was originated from the pesticides. In order to achieve more specific location of sources, an intensive investigation in the upstream is required.

Intensive Monitoring Survey of Nearby Galaxies (IMSNG) : Constraints on the progenitor system of a normal Type Ia SN 2019ein from its light curve at the early phase

  • 임구;임명신;김도형;백승학;최창수;김소피아;황성용
    • 천문학회보
    • /
    • 제46권1호
    • /
    • pp.55.2-56
    • /
    • 2021
  • The progenitor of Type Ia supernovae (SNe Ia) is mainly believed to be a close binary system of acarbon-oxygen white dwarf (CO WD) and non-degenerate companion (single degenerate) or another WD (double degenerate). However, it is unclear which system is more prevalent. Here, we present a high cadence optical/Near-IR light curve of normal but slightly faint type Ia SN 2019ein from IMSNG project. We fit the early light curve (t <+8.3 days from the first detection) with various models to find the shock-heated cooling emission from SN ejecta-companion interaction. No significant shock-heated cooling emission is found, from which we constrain the progenitor star size as the following. The upper limit (Rupper,*) of the companion size in R-band is ~0.2R when forcing the first light time (tfl) to have one value and ~0.9R when using the mean value of tfl from the fitting in each band. Assuming the source of the I-band curve is almost powered from the radioactive decay, we obtained Rupper,*~1.2R. The early B-V color curve is in agreement with the model color curve of the 2M main sequence companion. These results allow us to at least rule out large stars like red giants as a companion star of the binary progenitor system of this supernova. B-R and V-R color do not show any significant signs of a red bump, which shows a thin helium shell (MHe<0.1M) for the sub-Mch WD (double detonation model). In addition, we estimated the distance to NGC 5353 as 37.098±0.028Mpc.

  • PDF

매립지 온실 가스 배출량 산정을 위한 IPCC 선정방법별 특성 연구 (Study of Selected IPCC Methodologies for the Estimation of Greenhouse Gas Emissions from a Landfill)

  • 정성훈;황현욱;김명균;엔짜오쩡;느지오카 안토니 무투아;티네가 조셉 냐모코;김영주
    • 자원리싸이클링
    • /
    • 제25권5호
    • /
    • pp.28-35
    • /
    • 2016
  • 본 연구에서는 매립 처리시설를 대상으로 1996 IPCC G/L에 제시된 Tier 1 방법과 GPG 2000의 Tier 2 방법, 2006 IPCC G/L의 Tier 2 방법을 이용하여 매립시설에서 발생되는 온실가스 배출량을 산정하였으며 각 방법론 별로 적용상의 장단점 및 배출결과에 영향을 주는 요인과 산정된 배출량의 특성을 고찰하였다. 온실가스 배출량을 산정한 결과 1996 IPCC G/L Tier 1의 배출량은 2000 ~ 2013년 기간 동안 평균 약 2,760 ton/yr로 산정되었고, GPG 2000 Tier 2의 배출량은 평균 약 1,500 ton/yr, 2006 IPCC G/L Tier 2의 배출량은 평균 약 880ton/yr로 가장 낮게 산정되었다.

온실가스·에너지 목표관리제를 위한 폐기물 매립시설 메탄배출량의 적정 산정방법에 관한 고찰 (Review of the Estimation Method of Methane Emission from Waste Landfill for Korean Greenhouse Gas and Energy Target Management System)

  • 서동천;나제현;배성진;이동훈
    • 대한환경공학회지
    • /
    • 제35권12호
    • /
    • pp.867-876
    • /
    • 2013
  • 우리나라에서 시행되고 있는 '온실가스 에너지 목표관리제'의 효율적인 운영을 통하여 실질적인 온실가스 배출을 감축하고 향후 예정되어 있는 '탄소배출권 거래제'의 원활한 추진을 위해서는 온실가스배출량의 정확한 산정이 요구된다. 폐기물부문에서 주요 온실가스배출원인 폐기물 매립시설에 대해서도 목표관리제 운영지침에서 온실가스배출량 산정방법이 제시되어 있으나 계산방법과 매개변수 등에 오차요인이 있어 적정 산정방법에 대해 검토 제안하고자 하였다. 그 결과, 메탄회수율 0.75를 기준으로 산정방법을 구분하고 그 단일값과 메탄회수량으로부터 메탄발생량을 계산하는 방법은 삭제하여 온실가스배출량 산정과정의 중복적용과 과대평가 발생요인을 해소할 필요가 있음을 알 수 있었다. 메탄발생량은 일차분해모델로 추정하고 메탄회수량은 매립시설에서 측정한 값을 사용하도록 하되 과거 메탄회수량 데이터를 확보하기 곤란한 경우에는 메탄회수량을 산정할 수 있도록 일일복토나 중간복토가 포설된 사용중 매립시설에서는 가스배제공과 간이소각 0.60, 강제포집 시스템 0.65로, 최종복토가 이루어진 사용종료 매립시설은 자연적인 포집이나 강제포집이 수행되면 0.90으로 국내 매립시설에 적합한 조건별 메탄회수율 기준값을 제시하였다. 주요 매개변수 중 분해 가능한 유기탄소 비율(DOC)과 메탄으로 전환 가능한 DOC 비율($DOC_f$)은 국내 폐기물의 조성별 특성을 반영할 수 있도록 국내 연구결과를 이용하여 기준값을 도출하여 사용할 수 있으며, 메탄보정계수(MCF)는 매립시설의 설계나 설치 등의 단순한 기준으로 판단할 수 없으므로 명확한 기준이 요구되는 것으로 나타났다.

물질수지를 이용한 실내공기질 개선정도 평가 (Evaluation Method for Improvement of Indoor Air Quality Using Mass Balance)

  • 김영희;김문현;양원호
    • 한국환경과학회지
    • /
    • 제15권10호
    • /
    • pp.913-918
    • /
    • 2006
  • Despite the wide distribution of air pollutants, the concentrations of indoor air pollutants may be the dominant risk factor in personal exposure due to the fact that most people spend an average of 80% of their time in enclosed buildings. Researches for improvement of indoor air quality have been developed such as installation of air cleaning device, ventilation system, titanium dioxide$(TiO_2)$ coating and so on. However, it is difficult to evaluate the magnitude of improvement of indoor air quality in field study because indoor air quality can be affected by source generation, outdoor air level, ventilation, decay by reaction, temperature, humidity, mixing condition and so on. In this study, evaluation of reduction of formaldehyde and nitrogen dioxide emission rate in indoor environments by $TiO_2$ coating material was carried out using mass balance model in indoor environment. we proposed the evaluation method of magnitude of improvement in indoor air quality, considering outdoor level and ventilation. Since simple indoor concentration measurements could not properly evaluate the indoor air quality, outdoor level and ventilation should be considered when evaluate the indoor net quality.

물질수지를 이용한 학교 실내환경의 포름알데히드(HCHO) 배출량 산정에 의한 실내공기질 개선 평가 (Evaluation of Indoor Air Quality Improvement by Formaldehyde Emission Rate in School Indoor Environment Using Mass Balance)

  • 양원호;손부순;김대원;김영희;변재철;정순원
    • 한국산업보건학회지
    • /
    • 제15권3호
    • /
    • pp.160-165
    • /
    • 2005
  • Schools have significant and serious indoor environmental health problem, of which indoor air quality (IAQ) in school building may affect the health of the students and indirectly affect learning performance. Schools are of special concern when regarding indoor exposure to air pollutants, because students are particularly sensitive to pollutants and spend a significant amount of time in that environment. Therefore researches for improvement of indoor air quality have been developed such as installation of air cleaning device, ventilation system, titanium dioxide(TiO2) coating and so on. However, it is difficult to evaluate the magnitude of improvement of indoor air quality in field study because indoor air quality can be affected by source generation, outdoor air level, ventilation, decay by reaction, temperature, humidity, mixing condition and so on. In this study, evaluation of reduction of formaldehyde emission rate in school indoor environments by far-Infrared ray coating material was carried out using mass balance model in indoor environment. we proposed the evaluation method of magnitude of improvement in indoor air quality, considering outdoor level and ventilation. Since simple indoor concentration measurements could not properly evaluate the indoor air quality, outdoor level and ventilation should be considered when evaluate the indoor air quality.

Intensive Monitoring Survey of Nearby Galaxies (IMSNG) : Constraints on the Progenitor System of a Type Ia Supernova SN 2019ein from Its Early Light Curve

  • 임구;임명신;김도형;백승학;최창수;김소피아;황성용
    • 천문학회보
    • /
    • 제45권1호
    • /
    • pp.36.1-36.1
    • /
    • 2020
  • The progenitor of Type Ia supernovae (SNe Ia) is mainly believed to be a carbon/oxygen white dwarf (WD) with non-degenerate (single degenerate) or another WD companion (double degenerate). However, there is little observational evidence of their progenitor system. Recent studies suggest that shock-breakout cooling emission after the explosion can constrain the size of the progenitor system. To do so, we obtained a optical/Near-IR light curve of SN 2019ein, a normal but slightly sub-luminous type Ia supernova, from the very early phase using our high-cadence observation of Intensive Monitoring Survey of Nearby Galaxies (IMSNG). Assuming the expanding fireball model, the simple power-law fitting of the early part of the light curve gives power indices of 1.91 (B) and 2.09 (R) implying radioactive decay of 56Ni is the dominant energy source. By comparison with the expected light curve of the cooling emission, the early observation provides us an upper limit of the companion size of R∗≤1R⊙. This result suggests that we can exclude a large companion such as red giants, which is consistent with the previous study.

  • PDF

Formation of a large-scale quasi-circular flare ribbon enclosing three-ribbon through two-step eruptive flares

  • Lim, Eun-Kyung;Yurchyshyn, Vasyl;Kumar, Pankaj;Cho, Kyuhyoun;Kim, Sujin;Cho, Kyung-Suk
    • 천문학회보
    • /
    • 제41권2호
    • /
    • pp.42.1-42.1
    • /
    • 2016
  • The formation process and the dynamical properties of a large-scale quasi-circular flare ribbon were investigated using the SDO AIA and HMI data along with data from RHESSI and SOT. Within one hour time interval, two subsequent M-class flares were detected from the NOAA 12371 that had a ${\beta}{\gamma}{\delta}$ configuration with one bipolar sunspot group in the east and one unipolar spot in the west embedded in a decayed magnetic field. Earlier M2.0 flare was associated with a coronal loop eruption, and a two-ribbon structure formed within the bipolar sunspot group. On the other hand, the later M2.6 flare was associated with a halo CME, and a quasi-circular ribbon developed encircling the full active region. The observed quasi-circular ribbon was strikingly large in size spanning 650" in north-south and 500" in east-west direction. It showed the well-known sequential brightening in the clockwise direction during the decay phase of the M2.6 flare at the estimated speed of 160.7 km s-1. The quasi-circular ribbon also showed the radial expansion, especially in the southern part. Interestingly, at the time of the later M2.6 flare, the third flare ribbon parallel to the early two-ribbon structure also developed near the unipolar sunspot, then showed a typical separation in pair with the eastern most ribbon of the early two ribbons. The potential field reconstruction based on the PFSS model showed a fan shaped magnetic configuration including fan-like field lines stemming from the unipolar spot and fanning out toward the background decayed field. This large-scale fan-like field overarched full active region, and the footpoints of fan-like field lines were co-spatial with the observed quasi-circular ribbon. From the NLFF magnetic field reconstruction, we confirmed the existence of a twisted flux rope structure in the bipolar spot group before the first M2.0 flare. Hard X-ray emission signatures were detected at the site of twisted flux rope during the pre-flare phase of the M2.0 flare. Based on the analysis of both two-ribbon structure and quasi-circular ribbon, we suggest that a tether-cutting reconnection between sheared arcade overarching the twisted flux rope embedded in a fan-like magnetic field may have triggered the first M2.0 flare, then secondary M2.6 flare was introduced by the fan-spine reconnection because of the interaction between the expanding field and the nearby quasi-null and formed the observed large-scale quasi-circular flare ribbon.

  • PDF

일부 제조업 사업장의 사무 및 공장동에서의 라돈농도 수준 및 유효선량 평가 (Evaluation of Effective Dose and Exposure Levels of Radon in Office and Plant Buildings)

  • 정은교;김기웅
    • 한국산업보건학회지
    • /
    • 제27권1호
    • /
    • pp.38-45
    • /
    • 2017
  • Objectives: Radon may be second only to smoking as a cause of lung cancer. Radon is a colorless, tasteless radioactive gas that is formed via the radioactive decay of radium. Therefore, radon levels can build up based on the amount of radium contained in construction materials such as phospho-gypsum board or when ventilation rates are low. This study provides our findings from evaluation of radon gas at facilities and offices in an industrial complex. Methods: We evaluated the office rooms and processes of 12 manufacturing factories from May 14, 2014 to September 23, 2014. Short-term data were measured by using real-time monitoring detectors(Model 1030, Sun Nuclear Co., USA) indoors in the office buildings. The radon measurements were recorded at 30-minute intervals over approximately 48 hours. The limit of detection of this instrument is $3.7Bq/m^3$. Also, long-term data were measured by using ${\alpha}-track$ radon detectors(${\alpha}-track$, Rn-tech Co., Korea) in the office and factory buildings. Our detectors were exposed for over 90 days, resulting in a minimum detectable concentration of $7.4Bq/m^3$. Detectors were placed 150-220 cm above the floor. Results: Radon concentrations averaged $20.6{\pm}17.0Bq/m^3$($3.7-115.8Bq/m^3$) in the overall area. The monthly mean concentration of radon by building materials were in the order of gypsum>concrete>cement. Radon concentrations were measured using ${\alpha}-track$ in parallel with direct-reading radon detectors and the two metric methods for radon monitoring were compared. A t-test for the two sampling methods showed that there is no difference between the average radon concentrations(p<0.05). Most of the office buildings did not have central air-conditioning, but several rooms had window- or ceiling-mounted units. Employees could also open windows. The first, second and third floors were used mainly for office work. Conclusions: Radon levels measured during this assessment in the office rooms of buildings and processes in factories were well below the ICRP reference level of $1,000Bq/m^3$ for workplaces and also below the lower USEPA residential guideline of $148Bq/m^3$. The range of indoor annual effective dose due to radon exposure for workers working in the office and factory buildings was 0.01 to 1.45 mSv/yr. Construction materials such as phospho-gypsum board, concrete and cement were the main emission sources for workers' exposure.