• Title/Summary/Keyword: emergency power supply system

Search Result 90, Processing Time 0.027 seconds

The Construction of the Satellite communication network for Power Industry (전력산업용 위성통신망 구축)

  • Kim, Soo-Bae;Oh, Kyu-Whan;Jung, Kwang-Kyoon;Lee, Beom-Seok;Hyun, Duck-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.497-499
    • /
    • 2006
  • There are several types of communication method which is used for the supply of electric power stably. But the communication methods used in KEPCO have weak points in the viewpoint of economy, technology and management. The Satellite communication systems have competitive power in price and technology for national wide utility owing to its wide area coverage and stability. This paper presents various adapted examples of the Power industry using he satellite communication systems.

  • PDF

Portable Energy Storage System for DC House and Emergency Response in Indonesia

  • Hudaya, Chairul;Aryani, Dwi Riana;Heatubun, Yosca Rose Anggita;Taufiqurahman, Wahyu;Verdianto, Ariono;Garniwa, Iwa;Sung, Yung-Eun
    • Journal of Appropriate Technology
    • /
    • v.5 no.1
    • /
    • pp.33-37
    • /
    • 2019
  • One of main problems in developing electricity grid for archipelago country like Indonesia is the geographical concerns as it consists of many islands. In some rural areas, electricity has not been available yet due to the limited infrastructure access, leading to high investment cost. In this study, a portable energy storage system based on the lithium-ion batteries called Tabung Listrik or TaLis (DC-based power bank) and DC house system were proposed as the solution for providing electricity for rural areas with relatively lower cost. TaLis is designed to be portable so it is easy to carry around as well as it can be used for many purposes. Since 2017, TaLis prototype has been used as the energy storage in a DC house system at Sekolah Master Indonesia, where an array of PV rooftop is functioned as the main DC power supply. Besides, some TaLis were also dispatched for emergency response during the disaster situations in Indonesia, such as during the measles outbreak in Asmat-Papua, the earthquake disaster in Lombok and tsunami in Palu.

Characteristic of VSI Driven by Source Synchronous Type for the Utility Interactive using a Photovoltaic Generation for the LED Luminaire Emergency Exit Sign Operation (LED 비상 유도등 동작을 위한 태양광발전 계통연계 전원동기 방식의 전압형 인버터 구동 특성)

  • Hwang, Lark-Hoon;Na, Yong-Ju
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.5
    • /
    • pp.420-428
    • /
    • 2018
  • In this paper, represented uninterruptible power supply (UPS) equipment maintaining constant output voltage, the proposes a photovoltaic system constructed with a step up boosting chopper and single phase pulse width modulation (PWM) voltage source inverter. as power source disconnection, voltage variation and output current variation with load variation. This system is driven by being synchronized voltage fed inverter and AC source, and in the steady state of power source charge battery connected to DC side with solar cell using a Photovoltaic that it was so called constant voltage charge. It can be results of saving electric power, and through a normal operation of energy storage system (ESS), the system operated the LED a calling on signal changes at the airport in an efficient manner. In addition, better output waveform was generated because of PWM method, and it was proved to test by experiment maintained constant output voltage regardless of AC source disconnection, load variation, and voltage variation of AC power source.

A Study on the Dynamic Voltage Restorer to Application Luminaire for Emergency Exit Sign Operation to the Energy Storage System (에너지 저장장치(ESS)의 비상 유도등 동작을 적용한 순간전압강하 보상장치에 관한 연구)

  • Hwang, Lark-Hoon;Na, Seung-kwon;Kim, Jin Sun
    • Journal of Advanced Navigation Technology
    • /
    • v.19 no.5
    • /
    • pp.433-439
    • /
    • 2015
  • Recently, Interest in power the quality was increased because of increasing the use of sensitive load equipment into an electrical disturbance such as computer, Electricity, Electronics, Telecommunications and semiconductor device. In addition, To enhance power quality, the instantaneous voltage drop occurred in precision load equipment is a need for proper compensation. In order to solve the problem, The developed dynamic voltage restorer (DVR) using an electric double layer capacitor (EDLC) has been applied. In this paper, We will do study to apply hybrid capacitors that have high energy density to the same size compared to the EDLC to DVR. Also, As a emergency luminaires of emergency power supply that we can support more than 10 years of life was confirmed the applicability of hybrid capacitor.

Hard rock TBM project in Eastern Korea

  • Jee, Warren W.
    • Proceedings of the Korean Society for Rock Mechanics Conference
    • /
    • 2008.10a
    • /
    • pp.33-41
    • /
    • 2008
  • The longest tunnel has been halted at Daekwanryung by the failure of the host country of the Winter Olympiad in 2014, but modern High-Power TBM will come to Korea to excavate these long tunnels to establish the better horizontal connection between the western and eastern countries to improve the strong powerful logistic strategy of Korean peninsula. Train operation provides a key function of air movements in a long underground tunnel, and heat generation from transit vehicles may account of the most heat release to the ventilation and emergency systems. This paper indicates the optimal fire suppress services and safety provision for the long railway tunnel which is designed twin tunnel with length 22km in Gangwon province of Korea. The design of the fire-fighting systems and emergency were prepared by the operation of the famous long-railway tunnels as well as the severe lessons from the real fires in domestic and overseas experiences. Designers should concentrate the optimal solution for passenger's safety at the emergency state when tunnel fires, train crush accidents, derailment, and etc. The optimal fire-extinguishing facilities for long railway tunnels are presented for better safety of the comfortable operation in this hard rock tunnel of eastern mountains side of Korea. Since year 1900, hard rock tunnel construction has been launched for railway tunnels in Korea, tunnels have been built for various purposes not only for infrastructure tunnels including roadway, railway, subway, and but also for water and power supply, for deposit food, waste, and oils etc. Most favorable railway tunnel system was discussed in details; twin tunnels, distance of cross passage, ventilation systems, for the comfortable train operations in the future.

  • PDF

The Development of Flood Protection System for Pad Transformer using Pneumatic Pressure (공기압을 이용한 패드 변압기 침수방지용 장치 개발에 관한 연구)

  • Kim, Gi-Hyun;Lee, Sang-Ick;Bae, Seok-Myung;Jung, Chan-Oong;Lee, Jae-Yong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.1
    • /
    • pp.90-94
    • /
    • 2009
  • The inundation of substation and ground power equipment breaks out every summer season in low-lying downtown and low-lying shore by localized heavy rain, typhoon and tidal wave. For diminishing flood damage of electrical equipment in the root, flood protection system which is used the basic frame of Pad transformer is developed using pneumatic pressure. This system is established on pressure generator equipment and sensor of flooded level operates at flooding occurrence and is maintained a shutting tightly structure. The system is able to protect indraft water in Pad Transformer and supply the electricity at emergency(flooding). And we tested safety for insulation resistance at flooding and applying an electrical current. We estimate that loss cost which is caused by with flooding and the power failure will be diminished if it is addition to advances the reliability evaluation by setting an example.

Characteristics on Stand-alone Operation of a Doubly-fed Induction Generator Applied to Adjustable Speed Gas Engine Cogeneration System

  • Daido, Tetsuji;Miura, Yushi;Ise, Toshifumi;Sato, Yuki
    • Journal of Power Electronics
    • /
    • v.13 no.5
    • /
    • pp.841-853
    • /
    • 2013
  • An application of doubly-fed induction generator (DFIG), which is one of adjustable speed generators, to a gas engine cogeneration system has been investigated. To operate during a blackout as an emergency power supply is one of important roles for the gas engine cogeneration system. However, the DFIG requires initial excitation for startup during a blackout because the DFIG has no excitation source. In this paper, we propose the "blackout start" as a new excitation method to generate a rated voltage at the primary side during a blackout. In addition, a stand-alone operation following a blackout has been investigated by using experimental setup with a real gas engine. Power flows in the generating set with the DFIG at the stand-alone operation have been investigated experimentally. Experimental investigation of the power flow suggests that the generating set with DFIG has optimal speed in minimizing whole system losses.

Direct Load Control Algorithm Based Locational and Electric Load Characteristics (지역적 특성과 부하특성을 고려한 직접부하제어 알고리즘)

  • Shin, Ho-Sung;Song, Kyung-Bin;Moon, Jong-Fil;Kim, Jae-Chul;Nam, Bong-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.264-265
    • /
    • 2006
  • This paper presents direct load control algorithm based locational and electric load characteristics. Direct load control is defined that demand-side management program activities that can interrupt consumer load at the time of annual peak load by direct control of the utility system operator by interruption power supply to individual appliances or equipment on consumer premises. Korean power system is divided into 14-areas considering branches operating in KEPCO, and electric loads are classified into 19 load groups considering interruption costs in this paper. The purpose of proposed method is to decrease social losses by controlling electric loads mainly whose interruption costs are low. It is expected that the proposed algorithm can be used as the countermeasure for the emergency state of the electric power dispatch in a operation point of view.

  • PDF

An Adaptive Reclosing Algorithm Considering Distributed Generation

  • Seo, Hun-Chul;Kim, Chul-Hwan
    • International Journal of Control, Automation, and Systems
    • /
    • v.6 no.5
    • /
    • pp.651-659
    • /
    • 2008
  • Autoreclosing techniques have been used in power systems to maintain system stability and continuity of supply. Environmental and economical issues have driven significant increases in the development of distributed generation (DG). DG connected to distribution systems, however, may impose negative influences with respect to power quality, protection, and stability, because DG can cause some challenges to protection, especially to reclosing. For this reason, in order to improve the reliability and safety of the distribution system, the rules and guidelines suggest that the DG system needs to be rapidly disconnected from the system before reclosing. We present, in this paper, an adaptive reclosing algorithm considering the DG. The algorithm consists of an angle oscillation's judgment, the emergency extended equal-area criterion (EEEAC), the calculation of an optimal reclosing time, and a reconnection algorithm. Our simulation results for three different DG technologies with Electromagnetic Transient Program (EMTP) indicate that we can maintain transient stability while the DG is protected against disturbances.

An Adaptive Reclosing Technique Considering the Distributed Generation (분산전원을 고려한 적응적 재폐로 기법)

  • Seo, Hun-Chul;Kim, Chul-Hwan;Yeo, Sang-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.2
    • /
    • pp.227-232
    • /
    • 2007
  • The autoreclosing is applied to power system for maintaining system stability and continuity of supply. Developments on distributed generation(DG) grows significantly by environmental issues and economical issues. If the DG is connected to distribution system, the DG influences the technical aspects such as power quality, protection and stability. It causes the challenges to protection, especially to reclosing. In order to achieve reliability and safety of the distribution system, the rules and guidelines suggest that the DG units should be rapidly disconnected from the network before the reclosing. If the DG is disconnected whenever the fault occurs, it cannot be utilized effectively. This paper presents the adaptive reclosing algorithm considering the DG. The algorithm consists of angle oscillation's judgment, EEEAC(Emergency Expanded Equal-Area Criterion), calculation of optimal reclosing time and re-connection algorithm. The simulation is implemented for the DG technology by using EMTP MODELS. The simulation results show that the transient stability is maintained and the DG is protected against disturbance.