Proposal for Evacuee Guidance of Cloud-based Elevator System in Emergency Situation (클라우드 기반 비상탈출 시 피난유도 승강기시스템 제안)

  • Choi, Jun-Ho;Shin, Seung-Jung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.1
    • /
    • pp.25-28
    • /
    • 2015
  • Lifts are used as an essential means of transportation within the building in an emergency situation, when used as a means of escape, so expect a lot of research has been conducted high effect. Number of stories in the Seoul-rise building guidelines underground 7th floor, 53 ground floor, floor area $6,800m^2$, floor area $127,050m^2$, use is cultural and convention facilities and sales facilities, business facilities and accommodation (hotel), the construction of public housing (apartments) hagieneun not efficient to install elevators for evacuation mothada was determined separately in designing the lift is designed according to the standards of passenger lifts installed under a judgment as to use for evacuation. However, this does not include detailed design guidelines so far.[1] We propose the Evacuee Guidance of Elevator System that can be used as entering air equipment, sprinkler and smart phone evacuation system.

Analyzing Accessibility of Emergency Shelters Based on Service Population: The Case of Outdoor Evacuation Places for Earthquake in Jung-gu, Seoul (생활인구를 고려한 대피시설 접근성 분석: 서울 중구지역 지진 옥외 대피장소를 사례로)

  • Kim, Sang-Gyoon;Shin, Sang-Young;Nam, Hyeon-Jung
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.1
    • /
    • pp.51-62
    • /
    • 2022
  • Purpose: This study analyzes accessibility of outdoor evacuation places for earthquake and the accessibility improvement effects when expanding the evacuation places in accessibility-deficient areas. In order to consider real-world evacuees, the accessibility analysis is based on service population not on resident population. Method: Location-allocation model as a GIS-based spatial optimization mode is used to analyze accessibility and vulnerable areas to evacuation places. Of location-allocation problem types, 'Maximize Coverage' method is chosen to allocate as many potential evacuees as possible to evacuation places. And impedence cutoffs or evacuation distances (times) are applied to three classes: 500m (7.5 minutes), 1,000m (15 minutes), and 1,500m (22.5 minutes). Case study area is Jung-gu areas, Seoul as a high-density downtown area. Result: Results show that accessibility-deficient areas and population to evacuation places are much more in service population than in resident population. Accessibility is significantly improved when increases when expanding the evacuation places in accessibility-deficient areas. Yet, accessibility-deficient areas are still remained since available lands are insufficient in the high-density downtown area. Conclusion: The study suggests that temporary evacuation facilities like outdoor evacuation places for earthquake need to consider real potential evacuees based not only on resident population but also on service population. Also, policy measures to provide emergency shelters need to more utilize spatial optimization tools like location-allocation model.

A Study on the Residents Consciousness in Emergency Planning Zone for Radioactive Disasters (방사능 재난에 대한 방사선비상계획구역내 주민의식조사)

  • Namhee Park
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.4
    • /
    • pp.729-745
    • /
    • 2022
  • Purpose: This study collects basic data on the awareness of evacuation methods and evacuation facilities in the event of a radiological disaster of residents living in the emergency planning zone. Method: The residents of emergency planning zone were sampled using a random sampling method. A 1:1 interview was conducted using a structured questionnaire, and statistical analysis was performed using the minitab program. Result: First, the survey subjects showed a relatively low and negative awareness of the local government's work on radioactive disasters. Second, in terms of resident safety education, they had little experience in education, but they felt it was necessary and wanted education on evacuation methods, action tips, and the location of relief centers. Third, the location of the relief centers related to radioactive disasters was not well known, and there were many responses that they did not receive any guidance, and that they would be with their families when using the relief centers. Satisfaction levels were generally low with regard to the relief facilities. Fourth, the necessary priorities in preparation for radioactive disasters were education and training for radioactive disasters, facility supplementation, and supply of protective chemicals. Conclusion: The residents of emergency planning zone perceived the policies and tasks of the government or local governments relatively negatively in preparation for the occurrence of radioactive disasters, and their satisfaction was low. Regarding the matters pointed out as a priority, the government and local governments should publicize and educate the residents of accurate information and policies on radioactive disasters.

Identification of Evacuation Route Planning Elements for the Disabled by Considering Universal Design - A Study on the Welfare Center for the Disabled - (유니버설 디자인을 고려한 지체장애인 대피경로 계획요소 규명 - 장애인 종합복지관 시설을 대상으로 -)

  • Jung, Tae-Ho;Yang, Won-Jik
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.3
    • /
    • pp.672-686
    • /
    • 2022
  • Purpose: This study derived the planning factors affecting the evacuation route of facilities for the disabled and to identify the planning factors that affect each facility. Method: The PLS(Partial Least Square)Regression analysis was used to solve the problem of multicollinearity and number of samples. Result: As a result of analysis, The most important planning elements for each facility were derived as door: closing time (1.131), corridor: ramp for wheelchairs (1.227), stairs: emergency lighting for stairs (1.117), and evacuation space: evacuation space convenience facilities (1.106). Conclusion: In order to plan an effective evacuation route for the disabled, a universal design should be applied to consider the perception, needs, and satisfaction of the disabled, rather than a comprehensive reflection.

Analysis of the Evacuation Safety in a Fire at Welfare Center for Disabled (장애인복지관 화재 시 피난안전성 분석)

  • Park, Sunah;Lee, Jai Young
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.12
    • /
    • pp.315-322
    • /
    • 2021
  • This study analyzes the Required Safe Egress Time (RSET), in the event of a fire at a welfare center for the disabled, using the emergency passage according to the floor arrangement of users to evaluate the safety and the difference in RSET for each emergency passage using the Pathfinder simulation program to suggest an efficient evacuation method. As a result of RSET, it was found that there is no problem in evacuation safety for the current state of the facility's personnel allocation by satisfying the standard RSET in case of fire, and evacuation can be completed safely by evacuating through stairs rather than using elevators if possible. It is necessary for employees to be provided sufficient education and training in advance so that they can evacuate effectively with the disabled in case of fire. This study gives significance in saving many precious lives and safely evacuate in case of fire as evacuation routes were secured through the design, construction and operation of facilities for the disabled and the RSET was shortened through regular evacuation practices. It is necessary to discuss the further RSET studies based on the automatic fire shutters open or not when a fire occurs at a specific location following the installation of automatic fire shutter at the entrance of each floor of the facilities.

Development of M2M-based Underground Space (subway) Disaster Response Network and EL Display Integrated Board (M2M기반 지하공간(지하철) 재난대응 네트워크 및 EL 디스플레이 통합 보드 개발)

  • Park, Miyun;Kwon, Segon;Park, EunChurn;Lee, Jeonhun
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.4
    • /
    • pp.422-441
    • /
    • 2017
  • Notifying emergency evacuation methods, accurate disaster location and evacuation route guidance can be very active alternatives to quickly minimize evacuation and casualties in disaster situation in the development of subway disaster prevention detection system that detects the disaster signs at the subway station early on the basis of Internet of things and leads passengers to evacuate. It's not easy to ensure perfect functioning of fire fighting facilities and equipments due to underground space structure with narrow exits. Therefore, we developed disaster provision EL Display integrated board that can induce the most efficient evacuation and the field experiment was conducted to examine the practical application in this study. Especially the applicability was verified by field application test because there is no case in which EL panels are used to evacuate disasters.

Study on Disaster Prevention in Case of Fire at Subway Platform with Platform Screen Door

  • Rie, Dong-Ho;Yoon, Sung-Wook;Ko, Jae-Woong;Lee, Keun-Oh
    • International Journal of Safety
    • /
    • v.4 no.2
    • /
    • pp.36-42
    • /
    • 2005
  • A study on fire phenomena in a subway transit mass station has been carried out as a part of disaster prevention plan at the subway station. The ventilation facilities installed in both the platform and the trackway are designed to convert into a smoke exhaust system in emergency situation, creating an environment necessary for evacuation. 3 dimensional Numerical Simulations based on the CFD are carried out using a simulation tool, Fire Dynamic Simulator. Total of six different cases are made and performances are compared each other to find optimal vents operation to ensure safer environment for evacuation at the platform area considering the installation of platform screen door.

Analysis of Building Emergency Evacuation Process with Interactions in Human Behaviors (화재 시 재실자 행동의 상호 작용을 고려한 건물 피난 행태 분석)

  • Choi, Minji;Park, Moonseo;Lee, Hyun-Soo;Hwang, Sungjoo
    • Korean Journal of Construction Engineering and Management
    • /
    • v.14 no.6
    • /
    • pp.49-60
    • /
    • 2013
  • Evacuation process has been considered as one of the most important elements to be managed in public facilities. Although the importance is highlighted through numerous literatures, disaster evacuation planning, particularly fire accidents, faces a number of human behavior related limitations for a similar application to different types of facilities/occupants. To overcome the obstacles including complexity in human behaviors, a number of simulation techniques with limited consideration on human behaviors are utilized to predict foreseeable problems in evacuation process. Therefore, this research aims to propose system dynamics models incorporating human behaviors considering different types of occupants under disaster evacuation events. Analysis on emergent human behaviors such as group forming and interactions under urgent situation are conducted based on the main stream theories in social science field. The results suggest the influences of human behavior factors including cooperative intention, information sharing, and mobility change to evacuation behavior. The implications are expected to provide safety consideration at planning/designing phase of buildings and help facility safety managers for evacuation planning with more realistic management approaches.

Delineation of the evacuation route plan, relief camp and prioritization using GIScience

  • Joy, Jean;Kanga, Shruti;Singh, Suraj Kumar;Sudhanshu, Sudhanshu
    • Advances in environmental research
    • /
    • v.10 no.1
    • /
    • pp.1-15
    • /
    • 2021
  • Rising urban flood patterns are a universal phenomenon and a significant challenge for city government and urban planners worldwide. Urban flood problems range from relatively localized incidents to substantial incidents, which lead to cities being flooded for a few hours to several days. Therefore, the effect may be widespread, such as the temporary displacement of individuals, disruption to civic facilities, water quality degradation and the possibility of epidemics. The problems raised by urban flooding are highly challengeable and compound by ongoing climate change, with adverse implications for changes in rainfall and gaps in intra-urban rainfall distribution. Unplanned construction and invasions of large houses along rivers and watercourses have interfered in natural rivers and watercourses. As a result, the runoff has risen in proportion to the urbanization of the urban floods. The location of the relief camp and the priority for evacuation were determined, and the safest route to avoid floods were established. This method can be used for emergency planning in future flood incidents, and it will help plan disaster preparedness for Panchayat. This study will promote the flood plain's potential use for disaster management and land use planning virtually.

Analysis of Ambivalence Differences among Groups for Temporary Firefighting Facilities of Workers at Construction Sites (공사현장 근로자의 임시소방시설에 대한 집단 간 Ambivalence 차이분석)

  • Moon, Pil-Jae;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.4
    • /
    • pp.765-778
    • /
    • 2021
  • The purpose of this study is to prevent fire accidents in advance by deriving prior knowledge among groups about temporary fire-fighting facilities of workers at construction sites and devising appropriate improvement measures. The findings are as follows.First, in the case of fire extinguishers, statistical attention was paid to the contractor, supervisor, partner worker and fire extinguisher manager between designations. 87% of fire managers and 70% of facility supervisors said fire extinguisher management managers needed to be designated for each type of construction, which requires designation of fire extinguisher management managers, frequently checking and relocating. Second, in the case of simple fire extinguishing facilities, statistical attention was paid to the application of penalties for unauthorized use of fire extinguishing facilities with construction companies, supervisors, and business partners.Third, in the case of emergency alarm measures, statistical attention was paid to the application of emergency alarm sound to temporary broadcasting facilities with construction works, supervisors, and business partners.Fourth, in the case of induction, statistical attention was paid to the application of connection between construction works, supervisors, and partner workers, such as passage guidance, emergency lighting, etc.It was found that 65% of construction workers and 55% of electrical workers had different applications such as aisle guidance and emergency lighting for each type of business partner. In order to resolve blind spots such as evacuation zone guidance due to the structure of the building, it is necessary to easily distinguish the direction of the entrance door from a long distance by applying it in conjunction with passage guidance lights and emergency lighting.