• Title/Summary/Keyword: embedded testing

Search Result 411, Processing Time 0.025 seconds

Comorbid Gastric Adenocarcinoma and Gastric and Duodenal Strongyloides stercoralis Infection: A Case Report

  • Seo, An Na;Goo, Youn-Kyoung;Chung, Dong-Il;Hong, Yeonchul;Kwon, Ohkyoung;Bae, Han-Ik
    • Parasites, Hosts and Diseases
    • /
    • v.53 no.1
    • /
    • pp.95-99
    • /
    • 2015
  • Strongyloides stercoralis can cause systemic infection, termed strongyloidiasis, and gastrointestinal ulcer disease in immunocompromised patients. However, to our knowledge, there are no reported cases of comorbid gastric adenocarcinoma and S. stercoralis infection. Here, we report a case of an 81-year-old Korean man who presented with S. stercoralis infection coexisting with early gastric adenocarcinoma (T1aN0M0). S. stercoralis eggs, rhabditiform larvae, and adult females were observed in normal gastric and duodenal crypts. They were also observed in atypical glands representative of adenocarcinoma and adenoma. Preliminary laboratory tests revealed mild neutrophilic and eosinophilic leukocytosis. A routine stool test failed to detect rhabditiform larvae in the patient's fecal sample; however, S. stercoralis was identified by PCR amplification and 18S rRNA sequencing using genomic DNA extracted from formalin-fixed paraffin-embedded tissues. Postoperatively, the patient had a persistent fever and was treated with albendazole for 7 days, which alleviated the fever. The patient was followed-up by monitoring and laboratory testing for 4 months postoperatively, and no abnormalities were observed thus far. The fact that S. stercoralis infection may be fatal in immunocompromised patients should be kept in mind when assessing high-risk patients.

Clinical Characteristics of Patients with Major Depressive Disorder on Military Service and Conscription Issues Using K-WAIS-IV : A Retrospective Study (한국판 성인용 웩슬러 지능검사 4판(K-WAIS-IV)으로 살펴본 병무용 진단서 대상 주요우울장애 환자의 특성 : 후향적 연구)

  • Kim, Jiyoung;Park, Eunhee
    • Anxiety and mood
    • /
    • v.16 no.1
    • /
    • pp.32-40
    • /
    • 2020
  • Objective : The purpose of this study was to investigate the cognitive performance of major depressive disorder (MDD) in military service/conscription personnel who visited the psychiatric clinic for a medical certificate to consider the situation from the perspective of Korea's unique compulsory military system. We used the Korean Wechsler Adult Intelligence Scale-IV (K-WAIS-IV) as the test for verifying the suitable level of cognitive functioning for military service and as the embedded measure with reflecting suboptimal effort. Methods : The study was conducted on 56 (28 males, age 19-34) in/out-patients admitted to the psychiatry department and diagnosed with MDD (DSM-IV). All participants completed a structured clinical interview (MINI-Plus), as well as self-report questionnaires related to demographics and severity of clinical symptoms. K-WAIS-IV was administered to each subject to assess cognitive characteristics. Results : Military group showed significantly lower processing speed index (PSI) score including subtests of symbol search (SS) and coding (CD) score, compared to the control group. There was no other significant differences in the Full Scale IQ (FSIQ), Verbal Comprehension Index (VCI), Perceptual Reasoning Index (PRI), Working Memory Index (WMI) scores including sub-tests comprised of the above indices, and Reliable Digit Span (RDS), Enhanced-RDS-Revised (E-RDS-R) between the study and control groups. Conclusion : This study was the first effort to verify the characteristics of Korea's military group with MDD and suggest the applicability of PSI and processing speed of K-WAIS-IV as an embedded performance index to test sub-optimal effort or low motivation beyond the purpose of testing cognitive deficits.

Quality monitoring of complex manufacturing systems on the basis of model driven approach

  • Castano, Fernando;Haber, Rodolfo E.;Mohammed, Wael M.;Nejman, Miroslaw;Villalonga, Alberto;Lastra, Jose L. Martinez
    • Smart Structures and Systems
    • /
    • v.26 no.4
    • /
    • pp.495-506
    • /
    • 2020
  • Monitoring of complex processes faces several challenges mainly due to the lack of relevant sensory information or insufficient elaborated decision-making strategies. These challenges motivate researchers to adopt complex data processing and analysis in order to improve the process representation. This paper presents the development and implementation of quality monitoring framework based on a model-driven approach using embedded artificial intelligence strategies. In this work, the strategies are applied to the supervision of a microfabrication process aiming at showing the great performance of the framework in a very complex system in the manufacturing sector. The procedure involves two methods for modelling a representative quality variable, such as surface roughness. Firstly, the hybrid incremental modelling strategy is applied. Secondly, a generalized fuzzy clustering c-means method is developed. Finally, a comparative study of the behavior of the two models for predicting a quality indicator, represented by surface roughness of manufactured components, is presented for specific manufacturing process. The manufactured part used in this study is a critical structural aerospace component. In addition, the validation and testing are performed at laboratory and industrial levels, demonstrating proper real-time operation for non-linear processes with relatively fast dynamics. The results of this study are very promising in terms of computational efficiency and transfer of knowledge to manufacturing industry.

Reliability Evaluation of Extrapolated Failure Load of Drilled Shafts Embedded in Weathered Rock (풍화암에 근입된 현장타설말뚝의 외삽 파괴하중 신뢰성 분석)

  • Jung, Sung-Jun;Lee, Sang-Inn;Jeon, Jong-Woo;Kim, Myoung-Mo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.993-1000
    • /
    • 2009
  • In general, a drilled shaft embedded in weathered rock has a large load bearing capacity. Therefore, most of the load tests are performed only up to the load level that confirms the pile design load capacity, and stopped much before the failure load of the pile is attained. If a reliable failure load value can be extracted from the premature load test data, it will be possible to greatly improve economic efficiency as well as pile design quality. The main purpose of this study is to propose a standard for judging the reliability of the failure load of piles that is obtained from extrapolated load test data. To this aim, eleven static load test data of load-displacement curves were obtained from testing of piles to their failures from 3 different field sites. For each load-displacement curve, loading was assumed as 25%, 50%, 60%, 70%, 80%, and 90% of the actual pile bearing capacity. The limited known data were then extrapolated using the hyperbolic function, and the failure load was re-determined for each extrapolated data by the ASCE 20-96 method (1997). Statistical analysis was performed on the reliability of the re-evaluated failure loads. The results showed that if the ratio of the maximum-available displacement to the failure-load displacement exceeds 0.6, the extrapolated failure load may be regarded as reliable, having less than a conservative 20% error on average. The applicability of the proposed standard of judgment was also verified with static load test data of driven piles.

  • PDF

A study on wideband underwater acoustic signal amplifier design for generating multi-frequency (다중 주파수 재생을 위한 광대역 수중 음향 신호 증폭기 설계 연구)

  • Lee, Dong-Hun;Yoo, Seung-Jin;Kim, Hyeong-Moon;Kim, Hyoung-Nam
    • The Journal of the Acoustical Society of Korea
    • /
    • v.36 no.3
    • /
    • pp.179-185
    • /
    • 2017
  • The problem that occurred in the design/fabrication/testing of the wideband transmitting power amplifier for an embedded active SONAR (Sound Navigation and Ranging) system operating underwater was analyzed and the solution of the problem was proposed in this paper. Wideband acoustic SONAR systems had been developed in order to improve the underwater detection performance. The underwater acoustic transmission system had been also developed to achieve the wideband SONAR system. In this paper, the wideband acoustic transmission signal was generated using a 2 Level sawtooth type Class D PWM (Pulse Width Modulation) which was not complicated to implement. When the sonar signals having two or more frequencies were simultaneously generated, parasitic frequencies were added to the original signals by integer multiples of the frequency difference of the original signal. To cope with this problem, we proposed a way to remove the parasitic frequency from the source signal through modeling and simulation of the implemented power amplifier and PWM control hardware using MATLAB and Simulink.

A Novel Test Scheduling Algorithm Considering Variations of Power Consumption in Embedded Cores of SoCs (시스템 온 칩(system-on-a-chip) 내부 코어들의 전력소모 변화를 고려한 새로운 테스트 스케쥴링 알고리듬 설계)

  • Lee, Jae-Min;Lee, Ho-Jin;Park, Jin-Sung
    • Journal of Digital Contents Society
    • /
    • v.9 no.3
    • /
    • pp.471-481
    • /
    • 2008
  • Test scheduling considering power dissipation is an effective technique to reduce the testing time of complex SoCs and to enhance fault coverage under limitation of allowed maximum power dissipation. In this paper, a modeling technique of test resources and a test scheduling algorithm for efficient test procedures are proposed and confirmed. For test resources modeling, two methods are described. One is to use the maximum point and next maximum point of power dissipation in test resources, the other one is to model test resources by partitioning of them. A novel heuristic test scheduling algorithm, using the extended-tree-growing-graph for generation of maximum embedded cores usable simultaneously by using relations between test resources and cores and power-dissipation-changing-graph for power optimization, is presented and compared with conventional algorithms to verify its efficiency.

  • PDF

Numerical analysis of channel connectors under fire and a comparison of performance with different types of shear connectors subjected to fire

  • Shahabi, S.E.M.;Ramli Sulong, N.H.;Shariati, M.;Mohammadhassani, M.;Shah, S.N.R.
    • Steel and Composite Structures
    • /
    • v.20 no.3
    • /
    • pp.651-669
    • /
    • 2016
  • The behavior of shear connectors plays a significant role in maintaining the required strength of a composite beam in normal and hazardous conditions. Various types of shear connectors are available and being utilized in the construction industry according to their use. Channel connectors are a suitable replacement for conventional shear connectors. These connectors have been tested under different types of loading at ambient temperature; however, the behavior of these connectors at elevated temperatures has not been studied. This investigation proposes a numerical analysis approach to estimate the behavior of channel connectors under fire and compare it with the numerical analysis performed in headed stud and Perfobond shear connectors subjected to fire. This paper first reviews the mechanism of various types of shear connectors and then proposes a non-linear thermo-mechanical finite element (FE) model of channel shear connectors embedded in high-strength concrete (HSC) subjected to fire. Initially, an accurate nonlinear FE model of the specimens tested at ambient temperature was developed to investigate the strength of the channel-type connectors embedded in an HSC slab. The outcomes were verified with the experimental study performed on the testing of channel connectors at ambient temperature by Shariati et al. (2012). The FE model at ambient temperature was extended to identify the behavior of channel connectors subjected to fire. A comparative study is performed to evaluate the performance of channel connectors against headed stud and Perfobond shear connectors. The channel connectors were found to be a more economical and easy-to-apply alternative to conventional shear connectors.

The effect of various commercially available bleaching agents on the microshear bond strength of composite resin to enamel

  • Chang, Hoon-Sang;Cho, Kyung-Mo;Kim, Jin-Woo
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.3
    • /
    • pp.219-225
    • /
    • 2004
  • This study evaluated the microshear bond strength of composte resin to teeth bleached with commercial whitening strips and compared with those bleached with home bleaching gel. Twelve extracted human central incisors were cut into pieces and central four segments were chosen from each tooth and embedded in acrylic resin. Four blocks with 12 tooth segments embedded in acrylic resin were acquired and numbered from group one to group four. Group 1 was bleached with Crest Whitestrips, group 2 with Claren, group 3 with Opalescence tooth whitening gel (10% carbamide peroxide). Group 4 was used as control. The bleaching procedure was conducted for 14 days according to the manufacturer's instructions ; the bleaching strips twice a day for 30 min and the bleaching gel once a day for 2hr. After bleaching, composite resin (Filtek Supreme) was bonded to the enamel surfaces with a self-etching adhesive (Adper Prompt L-Pop) using Tygon tube. Microshear bond strength was tested with a universal testing machine (EZ-test). The data were statistically analysed by one-way ANOVA. The study resulted in no statistical differences in microshear bond strength between the tooth segments bleached with 2 different whitening strips and bleaching gel. It can be concluded that the effect of bleaching with either commercial whitening strips or bleaching gel on enamel is minimal in bonding with self-etching adhesive to composite resin.

A study on Communication Robustness Testing for Industrial Control Devices (산업용 제어기기의 통신 견고성 시험 방안 연구)

  • Park, Kyungmi;Shin, Donghoon;Kim, WooNyon;Kim, SinKyu
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.29 no.5
    • /
    • pp.1099-1116
    • /
    • 2019
  • Industrial control systems(ICS) are widely used in various industrial area and critical infrastructure. To mitigate security threats on ICS, the security assurance test for industrial control devices has been introduced and operating. The test includes testing of the security function of the device itself and testing of communication robustness. In this paper, we describe the security requirements of EDSA, Achilles, and Korea's TTA standard(security requirements for ICS). And also, we analyzed the characteristics of communication robustness test(CRT) of each certification. CRT verifies the device's operation of essential function while transmitting fuzzing and stress packets. Existing test methods are mostly focused on the embedded devices and are difficult to apply to various devices. We propose a method to test communication robustness which reflect the characteristics of control H/W, control S/W, field devices and network devices in ICS. In the future, we will apply the proposed communication robustness test to actual products and present solutions for arising issues.

A Study on the Evaluation of Radiation Safety in Opened-Ceiling-Facilities for Radiography Testing (천장 개방형 RT 사용시설의 방사선 안전성 평가 연구)

  • Sung-Hoe, Heo;Won-Seok, Park;Seung-Uk, Heo;Byung-In, Min
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.6
    • /
    • pp.741-749
    • /
    • 2022
  • Radiography-Testing that verify the quality of welding structures without destruction are overwhelmingly used in industries, but many safety precautions are required as radiation is used. The workers for Radiography-Testing perform the inspection by moving the Iridium-192 radiation source embedded in the transport container of the gamma-ray irradiator within or outside the facility. The general facility is completely blocked about radiation from the outside with thick concrete, but if it is difficult for worker to handle object of inspection, facilities ceiling can be opened. A general facility may be constructed using a theoretical dose evaluation method because all exterior facilities are blocked, but if the ceiling is open, it is not appropriate to evaluate radiation safety with a simple theoretical calculation method due to the skyshine effect. Therefore, in this study, the radiation safety of the facility was evaluated in the actual field through an ion chamber survey-meter and an accumulated dose-meter called as OSLD, and the actual evaluation environment was modeled and evaluated using the Monte Carlo simulation code as FLUKA. According to the direction of the irradiation, the radiation dose at the facility boundary was difficult to meet the standards set by the regulatory authority, and radiation safety could be secured through additional methods. In addition, it was confirmed that the simulation results using the Iridium-192 source were valid evaluation with the actual measured results.