• 제목/요약/키워드: embedded footing

검색결과 17건 처리시간 0.025초

3차원 수직 좌표계의 지반-구조물 상호작용해석을 위한 동적 무한요소의 개발 (3-DIMENSIONAL DYNAMIC INFINITE ELEMENTS IN CARTESIAN COORDINATES FOR MULTI-LAYERED HALF-SPACE)

  • 서춘교;윤정방
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2006년도 학술발표회 논문집
    • /
    • pp.628-636
    • /
    • 2006
  • This paper presents 3D infinite elements in Cartesian coordinates for the elastodynamic problem in multi-layered half-space. Five kinds of infinite elements are developed by using approximate expressions of multiple wave components for the wave function in exterior far-field soil region. They are horizontal, horizontal-corner, vertical, vertical-corner and vertical-horizontal-corner elements. The elements can be used for the multi-wave propagating problem. Numerical example analyses are presented for rigid disk, square footings and embedded footing on homogeneous and layered half-space. The numerical results obtained show the effectiveness of the proposed infinite elements.

  • PDF

기초 및 바닥층 동시타설 공사의 개선방안 연구 (An Improvement of Concurrent Placement of Footing and Slab Concrete)

  • 이동훈;최재휘;길종일;서덕석;김선국
    • 한국건축시공학회지
    • /
    • 제9권6호
    • /
    • pp.121-129
    • /
    • 2009
  • 중소규모 건축물의 시공 현장은 기초의 크기가 작고 터파기 깊이가 얕은 경우가 많다. 이런 경우 일반 거푸집을 이용하여 2회에 걸쳐 타설하는 기존의 재래식 공법보다 매립형 보조거푸집을 이용하여 기초 및 지중보와 바닥슬래브를 동시에 타설하는 공법을 사용하면 지하층 골조공기의 단축과 그에 따른 원가절감을 기대 할 수 있다. 기존의 매립형 보조거푸집은 거푸집의 종류에 따라서 자재와 인건비에 따른 원가, 품질상의 문제들이 있기 때문에 사용에 제약이 있다. 따라서 본 연구에서는 개선방안으로써 발포폴리스티렌을 매립형 보조거푸집으로 이용한 기초 및 지중보와 바닥슬래브 콘크리트 동시 타설공법을 제안하고, 기존의 공법들과 비교하며, 공법별 평가를 통하여 효용성을 검증하고자 한다.

기초형식 및 지반조건에 따른 하우스파이프기초의 인발저항력 특성 (Characteristics of Uplift Capacity of House Pipe Foundation according to Foundation Types and Soil Conditions)

  • 송창섭;장웅희;최득호;김정철
    • 한국농공학회논문집
    • /
    • 제62권1호
    • /
    • pp.117-126
    • /
    • 2020
  • The area of facility horticulture in Korea is increasing rapidly, the single-span pipe house which uses galvanized steel pipe as the main rafters occupies 78.7% of the facility area. Lightweight structures such as the single-span pipe house are vulnerable to meteorological disasters such as strong winds, economic losses of the state, local governments and farmers are continuing as construction does not meet the design standards. In order to minimize economic losses in the horticultural specialty facilities sector, the Rural Development Administration has been operating the horticultural disaster resilient standard for horticultural specialty facilities since April 2007. The only standard for the pipe connector is the disaster resilient standard, there is no standard for the uplift capacity of the house pipe foundation and the research on it is also insufficient. The purpose of this study is to investigate the characteristics of uplift capacity according to the foundation type, compaction ratio and embedded depth through soil box test. The results of the maximum uplift capacity according to the type, compaction ratio and embedded depth can be used as the basic data for the basic design of the pipe house conforming to the disaster resilient standard. Due to the limitation of soil box test, it may be different from the behavior of pipe house installed on site. In the future, the field test and the actual pipe house should be made and supplemented by comparing this result with the field test values.

Numerical study on the influence of embedment footing and vertical load on lateral load sharing in piled raft foundations

  • Sommart Swasdi;Tanan Chub-Uppakarn;Thanakorn Chompoorat;Worathep Sae-Long
    • Geomechanics and Engineering
    • /
    • 제36권6호
    • /
    • pp.545-561
    • /
    • 2024
  • Piled raft foundation has become widely used in the recent years because it can increase bearing capacity of foundation with control settlement. The design for a piled raft in terms vertical load and lateral load need to understands contribution load behavior to raft and pile in piled raft foundation system. The load-bearing behavior of the piled raft, especially concerning lateral loads, is highly complex and challenge to analyze. The complex mechanism of piled rafts can be clarified by using three dimensional (3-D) Finite Element Method (FEM). Therefore, this paper focuses on free-standing head pile group, on-ground piled raft, and embedded raft for the piled raft foundation systems. The lateral resistant of piled raft foundation was investigated in terms of relationship between vertical load, lateral load and displacement, as well as the lateral load sharing of the raft. The results show that both vertical load and raft position significantly impact the lateral load capacity of the piled raft, especially when the vertical load increases and the raft embeds into the soil. On the same condition of vertical settlement and lateral displacement, piled raft experiences a substantial demonstrates a higher capacity for lateral load sharing compared to the on-ground raft. Ultimately, regarding design considerations, the piled raft can reliably support lateral loads while exhibiting behavior within the elastic range, in which it is safe to use.

3차원 지반-구조물 상호작용해석을 위한 입방형 무한요소 (Cuboidal Infinite Elements for Soil-Structure-Interaction Analysis in Multi-Layered Half-Space)

  • 서춘교;윤정방;김재민
    • 한국전산구조공학회논문집
    • /
    • 제20권1호
    • /
    • pp.39-50
    • /
    • 2007
  • 본 논문은 다중 적층지반상의 지반-구조물 상호작용 해석을 위한 3차원 무한요소를 소개한다. 본 무한요소는 Cartesian 좌표계에서 정식화되었으며, 수평, 수평모서리, 수직, 수직 모서리 그리고 수평 수직 모서리 무한요소로서 총 5개의 무한요소로서 구성된다 적용한 형상함수 내부의 파동함수들은 적층지반의 파동문제를 효과적으로 모사하며 다중파동성분을 포함하고 있다. 본 요소의 성능을 검증하기 위하여 주파수영역에서 여러 가지 예제해석을 수행하였다. 균질 및 적층지반상 강체기초와 묻힌 케이슨 기초의 무차원 동적 거동(compliance & impedance)을 구하였으며, 기연구자들의 값과 비교 검토하였다.

급속시공형 프리캐스트 합성교각의 성능 (Performance of Precast Composite Piers for Fast Construction)

  • 심창수;정영수;윤재영;박지호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.221-224
    • /
    • 2008
  • 조립식 교각을 교량의 하부구조에 적용하는 다양한 기술들이 최근에 활발히 개발되고 있다. 이 논문에서는 프리스트레스를 필요로 하지 않는 형태의 프리캐스트 합성교각을 제안하였다. 낮은 강재비를 갖는 합성교각의 정적 및 내진성능 평가에 기반하여 교각 단면을 설계하고 기초부와의 연결상세는 교각 단면이 기초부로 일부 매입된 상태에서 볼트 연결로 설계하여 설계의 단순화를 도모하였다. 새롭게 제안된 프리캐스트 합성교각에 대한 구조적 성능을 검증하기 위해 준정적실험을 수행하였다. 실험을 통하여 정적 성능과 내진성능을 함께 평가하고 기존의 현장타설 합성교각의 거동과 비교를 수행하였다. 프리캐스트로 제작할 경우에 기초와 만나는 교각 끝단의 보강 상세가 요구되고 이와 관련한 상세 제안사항을 도출하였다.

  • PDF

강관 및 PHC 매입말뚝의 최적화에 따른 교량기초의 공사비 비교 (Comparison of Construction Costs for Bridge Foundation with Optimization of Steel and PHC Embedded Piles)

  • 윤중만;여규권;김홍연;김동민;김수로
    • 한국지반신소재학회논문집
    • /
    • 제15권4호
    • /
    • pp.71-78
    • /
    • 2016
  • 본 연구에서는 동일한 지층 및 하중조건에서 PHC말뚝을 강관말뚝으로 대체할 경우 말뚝 본수의 변화와 푸팅을 포함한 공사비를 비교하였다. 얕은 풍화암층에 강관말뚝을 지지할 경우 PHC말뚝과 비교하여 12.5%의 본수가 절감되었다. 실 사례로부터 가정된 1.7m 두께의 풍화암층을 통과하여 깊은기초를 연암층에 지지할 경우 일반 및 고강도 강관말뚝은 각각 풍화암층에 설치한 PHC 말뚝 대비 35.7% 및 46.4%, 강관말뚝 대비 26.5% 및 38.8%의 본수가 절감되는 효과가 있는 것으로 나타났다. 푸팅두께가 일정하다고 가정할 경우 풍화암층을 관통하여 연암층에 설치된 일반 및 고강도 강관말뚝은 풍화암층에 설치된 PHC말뚝 대비 각각 12.2% 및 45.4%까지 푸팅의 소요면적을 절감할 수 있는 것으로 나타났다. 이러한 결과를 가지고 말뚝시스템의 전체 공사비를 산정한 결과 풍화암에 지지된 PHC말뚝과 비교할 때 연암층에 설치된 일반 강관말뚝의 비용은 12% 높게 산정된 반면, 이를 고강도 강관말뚝으로 대체하였을 경우는 오히려 16% 절감효과가 있는 것으로 나타났다. 이는 고강도 강관말뚝의 재료비가 상대적으로 높으나 말뚝 본수 및 푸팅면적의 감소로 인한 비용 절감효과가 더 크기 때문이다. 풍화암층 두께를 변화시키며 해석하여 말뚝시스템의 공사비를 비교한 결과 풍화암층 두께가 5m 이하인 조건에서는 PHC말뚝을 풍화암층에 지지하는 것보다 이를 관통하여 연암층에 고강도 강관말뚝을 지지하는 것이 전체 공사비 측면에서 유리한 것으로 나타났다.