• Title/Summary/Keyword: elevation correction

Search Result 115, Processing Time 0.022 seconds

Relationship Analysis between Topographic Factors and Land Surface Temperature from Landsat 7 ETM+ Imagery (Landsat 7 ETM+ 영상에서 얻은 지표온도와 지형인자의 상관성 분석)

  • Lee, Jin-Duk;Bhang, Kon Joon;Han, Seung Hee
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.11
    • /
    • pp.482-491
    • /
    • 2012
  • Because the satellite imagery can detect the radiative heat from the surface using the thermal IR (TIR) channel, there have been many efforts to verify the relationship between the land surface temperature (LST) and urban heat island. However, the relationship between geomorphological characteristics like surface aspects and LST is relatively less studied. Therefore, the geomorphological elements, for example, surface aspects and surface slopes, are considered to evaluate their effects on the change of the surface temperature distribution using the Landsat 7 ETM+ TIR channel and the possibility of the image to detect anthropogenic heat from the surface. We found that the surface aspect is ignorable but the surface slope with the sun elevation influences on the surface temperature distribution. Also, the radiative heat from the surface to the atmosphere could not be accurately recorded by the satellite image due to the surface slope but the slope correction process used in this study could correct the surface temperature under slope condition and the slope correction, in fact, was not influenced on the average temperature of the surface. The possibility of the anthropogenic heat detection from the surface from the satellite imagery was verified as well.

Analysis on the estimation errors of the lowest and highest astronomical tides for the southwestern 2.5 GW offshore wind farm, Korea

  • Ko, Dong Hui;Jeong, Shin Taek;Cho, Hong-Yeon;Kang, Keum-Seok
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.10 no.1
    • /
    • pp.85-94
    • /
    • 2018
  • For the design of wind-power facilities, the highest and lowest astronomical tides (HAT and LAT, respectively) are needed for the tidal-water levels regarding international designs; however, the approximate highest high water and approximate lowest low water AHHW and ALLW, respectively, have been used in Korea. The HAT and LAT in the wind-farm test-bed sea should be estimated to satisfy the international standard. In this study, the HAT and LAT are therefore estimated using the hourly tidal-elevation data of the Eocheongdo, Anmado, Younggwang, Gunsan, Janghang, and Seocheon tidal-gauging stations that are located in the adjacent coastal sea. The nodal variation patterns of the major lunar components, such as $M_2$, $O_1$, and $K_1$ are analyzed to check the expected long-term lunar cycle, i.e., 18.61 year's nodal-variation patterns. The temporal amplitude variations of the $M_2$, $O_1$, and $K_1$ clearly show the 18.61-years periodic patterns in the case of the no-nodal correction condition. In addition, the suggested HAT and LAT elevations, estimated as the upper and lower confidence limits of the yearly HAT and LAT elevations, are 50 cm greater than the AHHW and 40 cm lower than the ALLW, respectively.

Design and Evaluation of Intelligent Helmet Display System (지능형 헬멧시현시스템 설계 및 시험평가)

  • Hwang, Sang-Hyun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.5
    • /
    • pp.417-428
    • /
    • 2017
  • In this paper, we describe the architectural design, unit component hardware design and core software design(Helmet Pose Tracking Software and Terrain Elevation Data Correction Software) of IHDS(Intelligent Helmet Display System), and describe the results of unit test and integration test. According to the trend of the latest helmet display system, the specifications which includes 3D map display, FLIR(Forward Looking Infra-Red) display, hybrid helmet pose tracking, visor reflection type of binocular optical system, NVC(Night Vision Camera) display, lightweight composite helmet shell were applied to the design. Especially, we proposed unique design concepts such as the automatic correction of altitude error of 3D map data, high precision image registration, multi-color lighting optical system, transmissive image emitting surface using diffraction optical element, tracking camera minimizing latency time of helmet pose estimation and air pockets for helmet fixation on head. After completing the prototype of all system components, unit tests and system integration tests were performed to verify the functions and performance.

A Comparison of Correction Models for the Prediction of Tropospheric Propagation Delay of GPS Signals (GPS 신호의 대류층 지연 예측을 위한 보정모델의 비교)

  • 이용창
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.20 no.3
    • /
    • pp.283-291
    • /
    • 2002
  • Since GPS's SA cancellation, the interest is converged in correction of errors such as atmospheric delay and multipath that weight had been small relatively, which can improve the accuracy of positioning through modelling research. The aim of this study have an extensive comparison of the various tropospheric delay models (Goad&Goodman, A&K, Hopfield and Sasstamoinen) and mapping functions(Niell, Chao, and Marini). Expecially, the tropospheric delay amounts by change of the GPS satellite elevations, and the delay by various combination between zenith delay models and mapping functions, compared and examined. For this, programmed the total delay models and the combined models which can be described as a product of the delay at the zenith and a mapping function. The result of study, especially, as the minimum elevation of included data is reduced under $10^{\circ}$, it was considered to be reasonable that the prediction of tropospheric delay considering combination and mapping character of functions about the transition of the zenith delay to a delay with arbitrary zenith angle.

A Study on the Comparison of Channel Selection and Precision Geometric Correction for Image Restoration of an Submerged Water (수몰 지역의 영상복원을 위한 정밀기하보정 및 채널선정 비교연구)

  • Yeon, Sang-Ho
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.7 no.1
    • /
    • pp.1-8
    • /
    • 2004
  • It's a very meaningful experimental study to image restoration of ancient villages vanished at the real life spatial world. Focused on Cheung-Pyung Lake around where most part were flooded by the Chung-Ju large dam founded in early 1980s, we used remote sensing technique in this study in order to restore topographical features before the flood with 3 dimensional effects. It was gathered comparatively good satellite photos and remotely sensed digital images, then its made a new color image from these and the topographical map which had been made before filled water. This task was putting together two kinds of different timed images. And then, we generated DEM(digital elevation model) including the outskirts of that area as harmonizing current contour lines with the map. That could be a perfect 3D image of Cheung-Pyung around before when it had been flood by making perspective images from all directions, north, south, east and west, for showing there in three dimensions. Also, flying simulation we made for close visiting can bring us to experience their real space at that time.

  • PDF

Developing GPS Code Multipath Grid Map (CMGM) of Domestic Reference Station (국내 기준국의 GPS 코드 다중경로오차 격자지도 생성)

  • Gyu Min Kim;Gimin Kim;Chandeok Park
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.13 no.1
    • /
    • pp.85-92
    • /
    • 2024
  • This study develops a Global Positioning System (GPS) Code Multipath Grid Map (CMGM) of each individual domestic reference station from the extracted code multipath of measurement data. Multipath corresponds to signal reflection/refraction caused by obstacles around the receiver antenna, and it is a major source of error that cannot be eliminated by differencing. From the receiver-independent exchange format (RINEX) data for two days, the associated code multipath of a satellite tracking arc is extracted. These code multipath data go through bias correction and interpolation to yield the CMGM with respect to the azimuth and elevation angles. The effect of the CMGM on multipath mitigation is then quantitatively analyzed to improve the Root Mean Square (RMS) of averaged pseudo multipath. Furthermore, the single point positioning (SPP) accuracy is analyzed in terms of the RMS of the horizontal and vertical errors. During two weeks in February 2023, the RMSs of the averaged pseudo multipath for five reference stations decreased by about 40% on average after CMGM application. Also, the SPP accuracies increased by about 7% for horizontal errors and about 10% for vertical errors on average after CMGM application. The overall quantitative analysis indicates that the proposed approach will reduce the convergence time of Differential Global Navigation Satellite System (DGNSS), Real-Time Kinematic (RTK), and Precise Point Positioning (PPP)-RTK correction information in real-time to use measurement data whose code multipath is corrected and mitigated by the CMGM.

The Evaluation of Accuracy for Airborne Laser Surveying via LiDAR System Calibration (시스템 초기화(Calibration)에 따른 항공레이저측량의 정확도 평가)

  • 이대희;위광재;김승용;김갑진;이재원
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2004.04a
    • /
    • pp.15-26
    • /
    • 2004
  • The calibration for systematic error in LiDAR is crucial for the accuracy of airborne laser scanning. The main error is the misalignment of platforms between INS(Inertial Navigation System) and Laser scanner For planimetrical calibration of LiDAR, the building is good feature which has great changes in height and continuous flat area in the top. The planimetry error(pitch, roll) is corrected by adjustment of height which is calculated from comparing ground control points(GCP) of building to laser scanning data. We can know scale correction of laser range by the comparison of LiDAR data and GCP is arranged at the end of scan angle where maximize the height error. The area for scale calibration have to be large flat and have almost same elevation. At 1000m for average flying height, The Accuracy of laser scanning data using LiDAR is within 110cm in height and ${\pm}$50cm in planmetry so we can use laser scanning data for generating 3D terrain surface, expecically digital surface model(DSM) which is difficult to measure by aerial photogrammetry in forest, coast, urban area of high buildings

  • PDF

Mini Neutron Monitors at Concordia Research Station, Central Antarctica

  • Poluianov, Stepan;Usoskin, Ilya;Mishev, Alexander;Moraal, Harm;Kruger, Helena;Casasanta, Giampietro;Traversi, Rita;Udisti, Roberto
    • Journal of Astronomy and Space Sciences
    • /
    • v.32 no.4
    • /
    • pp.281-287
    • /
    • 2015
  • Two mini neutron monitors are installed at Concordia research station (Dome C, Central Antarctica, $75^{\circ}06^{\prime}S$, $123^{\circ}23^{\prime}E$, 3,233 m.a.s.l.). The site has unique properties ideal for cosmic ray measurements, especially for the detection of solar energetic particles: very low cutoff rigidity < 0.01 GV, high elevation and poleward asymptotic acceptance cones pointing to geographical latitudes > $75^{\circ}S$. The instruments consist of a standard neutron monitor and a "bare" (lead-free) neutron monitor. The instrument operation started in mid-January 2015. The barometric correction coefficients were computed for the period from 1 February to 31 July 2015. Several interesting events, including two notable Forbush decreases on 17 March 2015 and 22 June 2015, and a solar particle event of 29 October 2015 were registered. The data sets are available at cosmicrays.oulu.fi and nmdb.eu.

Generation of the Orthoimage with the Correction of Building Occlusion

  • Yoo, Hwan-Hee;Sohn, Duk-Jae;Park, Hong-Gi
    • Korean Journal of Geomatics
    • /
    • v.1 no.1
    • /
    • pp.7-13
    • /
    • 2001
  • Geospatial Information Systems (GIS) have been employed to systematically manage and design land use in urban areas. This has increased the need for more accurate vector and raster data. In Korea, l/l,000-scale digital maps are used as vector data for the facility management in urban areas. This has increased the need for large scale orthoimages. Orthoimages generated from aerial imagery can provide accurate information, making possible the more effective city management. However, there is a large problem in using the orthoimages, i.e., currently available conventional orthoimages have not been generated based on Digital Elevation Model (DEM) that takes into account the building heights. So this causes the displacements of building image in large scale orthoimages. The present study is an attempt to generate the large scale orthoimages based on building DEM. The semiautomatic building extraction method can detect building outlines by mouse clicking on either building roofs or corners. Building DEM, based on the outline and calculated building height, was used to produce the large scale orthoimages with the corrected building occlusion.

  • PDF

SgrA* 22/43GHz KaVA observation and its Amplitude Calibration

  • CHO, ILJE;JUNG, TAEHYUN;ZHAO, GUANG-YAO;KINO, MOTOKI;SOHN, BONGWON
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.1
    • /
    • pp.73.2-73.2
    • /
    • 2016
  • We present the results of KaVA SgrA* observation together with Takahagi(32m), Yamaguchi(32m) and Nobeyama(45m) telescopes at 22 and 43GHz, respectively. In early 2014, G2 cloud was expected to encounter with SgrA* and to make a significant flux variation, but it has not been measured yet. So it's worth to check our amplitude calibration method to confirm if we have a missing flux caused by uncertainty in measuring it. We have tested both a standard method using system noise temperature(Tsys) with antenna gain information, and a template method in order to calibrate antenna gain using nearby maser source. As a result, we found that the latter method is useful for antennas which have inaccurate gain information or poor Tsys measurements, and is especially effective for sources at low elevation like SgrA*. In addition, the comparison shows that the amplitude calibration by standard method can be improved up to 10% with a correction factor using a template method. This result implies we can get more accurate flux from a standard method when any maser source not exists around target.

  • PDF