• Title/Summary/Keyword: elements in particulate matter

Search Result 55, Processing Time 0.022 seconds

Measurement of the Elemental Composition in Airborne Particulate Matter Using Instrumental Neutron Activation Analys

  • Chung, Yong-Sam;Lim, Jong-Myoung;Moon, Jong-Hwa;Kim, Sun-Ha;Cho, Hyun-Je;Kim, Young-Jin
    • Nuclear Engineering and Technology
    • /
    • v.36 no.5
    • /
    • pp.450-459
    • /
    • 2004
  • For the evaluation of emission sources by air sampling, airborne particulate matter for fine (<2.5 ${\mu}m2$ EAD : $PM_{2.5}$) and coarse partical (2.5-10 ${\mu}m2$ EAD : $PM_{2.5-10}$ fractions were collected using a Gent stacked filter unit low volume sampler and two types of polycarbonate filters. Air samples were collected twice monthly at two regions in and around Daejeon city in the Republic of Korea from January to December 2002. Monthly mass concentration of $PM_{2.5}$ and $PM_{2.5-10}$ were measured and the concentrations of 10 marker elements (Al, Sc, Ti ; Na, Cl ; As, V. Sb, Br, Se) were determined by an instrumental neutron activation analysis. Analytical quality control was corried out using certified reference materials. Enrichment factors were also calculated from the monitoring data to classify the anthropogenic and crustal origins.

Increase of Cardiometabolic Biomarkers Among Vehicle Inspectors Exposed to PM0.25 and Compositions

  • Ramdhan, Doni Hikmat;Kurniasari, Fitri;Tejamaya, Mila;Fitri, Aidila;Indriani, Aisyah;Kusumawardhani, Adinda;Santoso, Muhayatun
    • Safety and Health at Work
    • /
    • v.12 no.1
    • /
    • pp.114-118
    • /
    • 2021
  • Background: Exposure to particulate matter (PM) emitted from vehicle exhaust might disrupt systemic function and elevate the risk of cardiovascular disease. In this study, we examined the changes of cardiometabolic biomarkers among vehicle inspectors exposed daily to PM0.25 and components. Methods: This cross-sectional study was conducted at two vehicle inspection centers, Pulogadung and Ujung Menteng, located in East Jakarta, Indonesia. The exposed respondents were 43 workers from vehicle inspection centers, and the unexposed group consisted of 22 staff officers working in the same locations. Vehicle exhaust particulate matter was measured for eight hours using a Leland Legacy personal pump attached to a Sioutas Cascade Impactor. The used filters were 25 and 37-mm quartz filters. The particulate matter concentration was analyzed using a gravimetric method, whereas trace elements were analyzed using energy dispersive X-ray fluorescence. An EEL Smoke Stain Reflectometer analyzed black carbon. Results: The personal exposure concentrations of PM0.25 were 10.4-fold higher than those in unexposed groups. Calcium and sulfur were the major components in the obtained dust, and their levels were 3.3- and 7.2-fold higher, respectively, in the exposed group. Based on an independent-samples t-test, high-density lipoprotein, triglyceride, HbA1c, total immunoglobulin E, high-sensitivity C-reactive protein, tumor necrosis factor-alpha, and nitric oxide levels were significantly different between the groups. Conclusions: In summary, it was suggested that PM0.25 exposure from vehicle exhaust might affect cardiometabolic biomarkers change.

Elemental Composition and Source Identification of PM2.5 in Jeju City (제주시 미세먼지(PM2.5)에 함유된 원소의 조성특성 및 오염원)

  • Lee, Ki-Ho;Hu, Chul-Goo
    • Journal of Environmental Science International
    • /
    • v.27 no.7
    • /
    • pp.543-554
    • /
    • 2018
  • From November 2013 to December 2016, ambient fine particulate matter ($PM_{2.5}$) was sampled in the downtown area of Jeju City, South Korea, which has seen rapid urbanization. The atmospheric concentrations of elements were measured in the $PM_{2.5}$ samples. This study focused on Cd, Cr, Cu, Mn, Ni, Pb, As, Sb, Sn, V, and Zn. The concentrations of Al, Na, K, Fe, Ca, Mg, Sr, and La were also obtained for reference. The objectives of this study were to examine the contributions of these elements to $PM_{2.5}$ concentrations in downtown Jeju City, and to investigate the inter-element relationships and the elemental sources by using enrichment factors and principal components analysis (PCA). A composition analysis showed that the 19 elements constituted 6.65 % of the $PM_{2.5}$ mass, and Na, K, Al, Fe, Ca, Mg, and Zn constituted 98 % of the total ion mass. Seasonal trend analysis for the sampling period indicated that the concentrations of the elements increased from November to April. However, no substantial seasonal variations were found in the concentrations of the elements. The composition ratios of some elements (Cu/Zn, Cu/Cd, Cu/Pb, V/Ni, and V/La) were found to be out of range when compared to the literature from other urban areas. The ratios between the elements and the PCA results showed that local contaminant sources in Jeju City rarely influence the composition of $PM_{2.5}$. This suggests that the major sources of $PM_{2.5}$ in Jeju City may include long-range transport of fine particulate matter produced in other areas.

Characteristics of Atmospheric Respirable Particulate Matters and Trace Elements within Industrial Complex and Residential Sites in an Industrial City (산업 도시의 산업단지 부지와 주거 지역의 대기 중 호흡성 분진과 구성 미량 원소의 특성)

  • Kim, Mo-Geun;Shin, Seung-Ho;Jo, Wan-Kuen
    • Environmental Analysis Health and Toxicology
    • /
    • v.25 no.1
    • /
    • pp.27-40
    • /
    • 2010
  • The current study was designed to scientifically evaluate the atmospheric particulate pollution in residences relative to their proximity to a Korean major iron/metal industrial complex (IMIC). This objective was achieved by measuring the concentrations and elemental composition of particulate matter with aerodynamic diameters equal to or less than 10 ${\mu}m$(PM10) in industrial ambient air from IMIC and residential ambient air with relative proximities to IMIC. The trace metals were analyzed using an inductively coupled plasma-atomic emission spectroscopy (ICP-AES). The industrial mean values exceeded the Korean year/70-${\mu}g/m^3$ standard for PM10, whereas the residential mean values did not. However, the maximum residential values did exceed or were close to the Korean PM10 year standard. For individual elements, the ambient concentrations ranged widely from values in the order of a few $ng/m^3$ to thousands of $ng/m^3$. The residential mean mass concentrations in the PM10 measured in the present study were higher than or similar to those reported in earlier studies. This study suggests that residents in neighborhoods near the IMIC are exposedto elevated particulate levels compared to residents living further away from such a source.

Study on Airborne Particulate Matter ($PM_{10}$) Monitoring in Urban and Rural Area by Using Gent SFU Sampler and Instrumental Neutron Activation Analysis (중성자 방사화분석법과 Gent SFU 샘플러를 이용한 도시의 농촌지역의 대기분지($PM_{10}$)관측 연구)

  • 정용삼;문종화;김선하;박광원;강상훈
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.5
    • /
    • pp.453-467
    • /
    • 2000
  • The aim of this research is to collect and characterize fine particles (FPM:$\leq$2.5${\mu}{\textrm}{m}$) and coarse particles (CPM: 2.5~10${\mu}{\textrm}{m}$) using a low volume air sampler provided by the IAEA, at urban (Taejon) and rural area(Wonju) for a period of about two years(April 1996 to May 1998) and to promote a use of nuclear analytical techniques for air pollution studies. For the collection of airborne particulate matter (PM(sub)10), the Gent stacked filter unit sampler and polycarbonate membrane filters were employed. The concentration of trace elements in collected APM samples were determined byu instrumental Neutron Activation Analysis. For validation of the analytical data, internal quality control were implemented by using both the comparison of the analytical results of standard reference materials(NIST SRM 1648) and interlaboratory comparison for proficiency test (NAT-3). The standard uncertainty was less than 15% and Z-score of two samples were within $\pm$1. The monitoring of (PM(sub)10) mass concentration and elemental concentrations were carried out weekly. The average mass concentration of (PM(sub)10) in urban and rural areas were 59.2$\pm$36.5$\mu\textrm{g}$/㎥ and 41.4$\pm$23.7$\mu\textrm{g}$/㎥, respectively. To investigate the emission source, the enrichment factors were calculated for the fine and coarse particle fractions at two sites, respectively and these values were classified for anthropogenic and soil origin elements.

  • PDF

Emission Characteristics of Elemental Constituents in Fine Particulate Matter Using a Semi-continuous Measurement System (준 실시간 측정시스템을 이용한 미세입자 원소성분 배출특성 조사)

  • Park, Seung-Shik;Ondov, John M.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.2
    • /
    • pp.190-201
    • /
    • 2010
  • Fine particulate matter < $1.8{\mu}m$ was collected as a slurry using the Semicontinuous Elements in Aerosol Sampler with time resolution of 30-min between May 23 and 27, 2002 at the Sydney Supersite, Florida, USA. Concentrations of 11 elements, i.e., Al, As, Cd, Cr, Cu, Fe, Mn, Ni, Pb, Se, and Zn, in the collected slurry samples were determined off-line by simultaneous multi-element graphite furnace atomic absorption spectrometry. Temporal profiles of $SO_2$ and elemental concentrations combined with meteorological parameters such as wind direction and wind speed indicate that some transient events in their concentrations are highly correlated with the periods when the plume from an animal feed supplement processing facility influenced the Sydney sampling site. The peaking concentrations of the elemental species during the transient events varied clearly as the plume intensity varied, but the relative concentrations for As, Cr, Pb, and Zn with respect to Cd showed almost consistent values. During the transient events, metal concentrations increased by factors of >10~100 due to the influence of consistent plumes from an individual stationary source. Also the multi-variate air dispersion receptor model, which was previously developed by Park et al. (2005), was applied to ambient $SO_2$ and 8 elements (Al, As, Cd, Cr, Cu, Fe, Pb, and Zn) measurements between 20:00 May 23 and 09:30 May 24 when winds blew from between 70 and $85^{\circ}$, in which animal feed processing plant is situated, to determine emission and ambient source contributions rates of $SO_2$ and elements from one animal feed processing plant. Agreement between observed and predicted $SO_2$ concentrations was excellent (R of 0.99; and their ratio, $1.09{\pm}0.35$) when one emission source was used in the model. Average ratios of observed and predicted concentrations for As, Cd, Cr, Pb, and Zn varied from $0.83{\pm}0.26$ for Pb to $1.12{\pm}0.53$ for Cd.

Comparison of Characteristics of Local Meteorological and Particulate Matter(TSP) on the Beopjusa Temple and Seonamsa Temple (법주사와 선암사의 국지 기상 및 미세먼지 특성 비교)

  • Kim, Myoung Nam;Lim, Bo A;Lee, Myeong Seong;Jeong, So Young
    • Journal of Conservation Science
    • /
    • v.33 no.4
    • /
    • pp.283-295
    • /
    • 2017
  • It is crucial to measure meteorological elements in relation to the biodeterioration of building cultural heritages. The Beopjusa and Seonamsa temples located respectively in Chungbuk and Jeonnam provinces, Korea, exhibit biological damage to the building cultural heritages and cause noticeable climatic differences. To compare biodeterioration environments of the abovementioned temples, 10 meteorological elements were observed, and particulate matter (TSP) was collected at each location. Furthermore, a correlation analysis was conducted between meteorological elements, and between meteorological elements and TSP. The local meteorology at Beopjusa temple characteristically showcased high total horizontal radiation, UV radiation, evaporation, wind speed, and TSP concentration, whereas, that at Seonamsa temple showcased high temperature, humidity, dew point temperature, air pressure, precipitation and number of days with precipitation. An elemental analysis of TSP revealed the presence of sae-salts at Seonamsa temple, and compared to that of Beopjusa temple, the monthly frequencies of biogenic aerosol and Fe-containing particles were higher. The correlation analysis showed that wind speed and humidity were major meteorological factors at Beopjusa and Seonamsa temples, respectively. Subsequently, the characteristics of the local meteorology at Seonamsa temple are expected to affect the biological damage of the building cultural heritages, which is favorable for the growth of various organisms.

A Study on Airborne Particulate Matter of a Local Area in Seoul (서울시 일부 지역의 대기 중 미세먼지에 관한 연구)

  • Kim Sung-Yeon;Chung Mooh-Ho;Son Bu-Soon;Yang Won-Ho;Choi Kyung-Ho
    • Journal of Environmental Health Sciences
    • /
    • v.31 no.4 s.85
    • /
    • pp.301-308
    • /
    • 2005
  • The purpose of this study was to characterize mass concentration of $PM_{10}\;to,\;PM_{2.5}$ and metallic composition using Minivol Portable Sampler from May 2003 to May 2004 in metropolitan city, Seoul. Annual average concentration of $PM_{10}$ were $57.67({\pm}28.20)\;{\mu}g/m^3\;and\;PM_{2.5},\;were\;42.06({\pm}20.23)\;{\mu}g/m^3$. The concentration was the highest in winter because persistent thermal inversion and in spring, particulate matter concentration was high because of yellow-sand events. The average $PM_{2.5}/PM_{10}$ ratio was 0.73. This indicated $PM_{2.5}$ fraction played a significant role in air pollution. The atmospheric metallic elements in the $PM_{10},PM_{2.5}$ came different emission sources such as soil, traffic, industry and resuspended particles. The results showed that average $PM_{10}$ composition order as Fe>Zn>Pb>Cu>Mn. The metallic elements Zn and Fe were the largest composition in the $PM_{2.5}$

Determination of Metallic Elements in Urban Particulate Matter (SRM 1648) by ICP-MS and AAS (ICP-MS와 AAS를 이용한 대기 입자상 표준물질 (SRM 1648) 금속성분의 정량에 관한 연구)

  • Yoo Su-Young;Choi Kum-Chan;Kim Ki-Hyun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.4
    • /
    • pp.423-430
    • /
    • 2005
  • This study was investigated with sample digestion techniques and a reliability of the analytical results for a quantitative analysis of a standard reference material ('urban particulate matter', SRM 1648). The metallic elements were analyzed by inductively coupled plasma mass spectrometry (ICP-MS) with closed vessel microwave acid digestion method and atomic absorption spectroscopy (AAS). Quality control of the overall analytical procedures for metallic element determinations of standard reference material were estimated by analysis of a SRM 1648. Three digestion solutions $(type\;1:\;HNO_3,\;type\;2:\;HNO_3\;and\;H2O_2(4'1)\;mixture,\;type\;3:5.55\%\; HNO_3\;and\;16.75\%\;HCI\;mixture)$ were applied to SRM 1648. As a result, three digestion solutions used in this study are completely unable to digest Cr of SRM 1648. Reliability of Cr and As showed some errors in the digestion with digestion solution type (3) due to the influence of chlorides. Type (3) digestion solutions are sufficient to fulfill the digestion of As as well as Se in SRM 1648. ICP-MS results showed the improvement in accurate and precise determination of some trace elements like Cd, V and Pb in SRM 1648. It is important to use the proper digestion solution for each element to qualify analytical precision.