• 제목/요약/키워드: electrostatic spray

검색결과 60건 처리시간 0.032초

Evaluation of the Induction and Ionized Field Charging Methods for Electrostatic Nozzles of Orchard Sprayer

  • Laryea, G.N.;No, S.Y.;Lee, D.H.
    • Agricultural and Biosystems Engineering
    • /
    • 제3권1호
    • /
    • pp.29-34
    • /
    • 2002
  • Two charging methods of electrostatic nozzle, i.e. induction and ionized field corona charging, were designed and evaluated for orchard sprayer application. An artificial (metallic) target was constructed and used in this experiment. The charge-to-mass ratio for the induction electrode was measured by using the Faraday cage. Two conventional pressure-swirl nozzles have been employed with different orifice diameters under the same experimental operating conditions. A commercial pressure-swirl nozzle with orifice diameter of 1.0 was used for the conventional spray. The diameter of the electrostatic was 0.59 mm. The experiment was carried out for individual nozzle sprays at $0^{\circ}$, $20^{\circ}$ and $50^{\circ}$ oriented angles and three nozzles, sprayed simultaneously at a distance of 1.0 and 2.0 m from the nozzle tip to the target. The nozzles were mounted on a carriage with constant speed of 1.26 km/h with a blower attached. The weighing method was employed to evaluate for the spray deposition, ground loss and estimated drift. The results show more promising for the induction charging method, especially at $20^{\circ}$oriented angle at a distance of 1.0 m from the target for a single nozzle and when all three nozzles were operated simultaneously for spray deposition. The results of the induction charging method show promising with the developed electrostatic technique.

  • PDF

정전분무법을 이용한 YSZ 박막 제조 (Preparation of Thin YSZ Film by Electrostatic Spray Deposition)

  • 권병완;김진수;박정훈
    • 공업화학
    • /
    • 제19권1호
    • /
    • pp.117-121
    • /
    • 2008
  • 본 연구에서는 정전분무법을 이용하여 YSZ 박막을 제조하였다. 제조된 박막은 제조시 전구체 용액, 지지체 온도 등에 크게 영향을 받았으며, 특히 지지체 온도가 $400^{\circ}C$일 때 치밀한 YSZ 박막을 형성할 수 있었다. 최적조건 하에서 정전분무법을 활용하면 약 $12{\mu}m/h $의 속도로 치밀한 YSZ 박막을 형성할 수 있었다. 제조된 박막은 XRD, FE-SEM, EDX 등을 이용하여 분석하였다.

Electrostatic Spray 기술을 이용한 GABA 생성 유산균 함유 곡류 제품 개발 (Development of Cereal Product Containing γ-Aminobutyric Acid Producing Lactic Acid Bacteria Using Electrostatic Spray Technology)

  • 정지희;안도균;김동균;김광엽
    • 한국식품영양과학회지
    • /
    • 제46권8호
    • /
    • pp.979-985
    • /
    • 2017
  • 본 연구는 유산균에 의한 gamma aminobutyric acid(GABA)의 생산 및 쌀겨 추출물을 이용한 최적 배지의 제조를 목표로 하고 electrostatic spray는 곡물에 GABA 함량을 증진시키기 위해 사용하였다. 분리한 Lactobacillus brevis CFM11을 MRS 배지를 이용하여 최적 조건($37^{\circ}C$, 24시간, pH 6.5)에서 배양시킨 결과, $600.12{\mu}g/mL$의 GABA 생성량을 나타냈고 0.8% MSG를 함유한 MRS 배지에서 배양시켰을 때 $2,002.93{\mu}g/mL$의 GABA 생성량을 나타냈다. 미강 추출물 배지에 MSG 0.4%, sucrose 2%, skim milk 1%, magnesium sulfate 0.2%를 첨가했을 때 GABA 생산량은 $585.80{\mu}g/mL$로 나타났다. 최적화 배지에 L. brevis CFM11을 배양시켜 얻은 GABA를 쌀 표면에 electrostatic spray 처리 후 GABA량은 $228.10{\mu}g/g$으로 나타난 반면, 아무것도 처리하지 않은 곡류에서의 GABA량은 $32.23{\mu}g/g$이었다. 이러한 결과로 보아 미강 추출물은 GABA 생산을 위한 MRS 배지의 대체물로서 산업적인 가치를 증가시킬 수 있을 것으로 판단된다.

공압과 정전기력을 이용한 스프레이 박막 코팅 기술 개발 (Development of Spray Thin Film Coating Method using an Air Pressure and Electrostatic Force)

  • 김정수;김동수
    • 한국정밀공학회지
    • /
    • 제30권6호
    • /
    • pp.567-572
    • /
    • 2013
  • In many electro-devices, the vacuum process is used as the manufacturing process. However, the vacuum process has a problem, it is difficult to apply to a continuous process such as a R2R(roll to roll) printing process. In this paper, we propose an ESD (electro static deposition) printing process has been used to apply an organic solar cell of thin film forming. ESD is a method of liquid atomization by electrical forces, an electrostatic atomizer sprays micro-drops from the solution injected into the capillary with electrostatic force generated by electric potential of about several tens kV. The organic solar cell based on a P3HT/PCBM active layer and a PEDOT:PSS electron blocking layer prepared from ESD method shows solar-to-electrical conversion efficiency of 1.42% at AM 1.5G 1sun light illumination, while 1.86% efficiency is observed when the ESD deposition of P3HT/PCBM is performed on a spin-coated PEDOT:PSS layer.

도장설비에서의 정전기 재해 사례 연구 (Case Study on the Electrostatic Hazards in the Coating Mechanical System)

  • 김길태;정영만;이재근
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.602-606
    • /
    • 2006
  • The electrostatic is well known phenomena. The fires and explosions caused by electrostatic occur often in the coating mechanical system. This paper presents various cases of electrostatic hazards, reasons why electrostatic hazards are happened, and methods for preventing electrostatic hazards. Generally the electrostatic can be lead to corona discharging, streaming electrification, and impinging electrification in the coating process. Corona discharging happens at electrostatic spray gun with 70 kV. Streaming electrification occurs at mixing process between paint and thinner, and transportation process with thinner. Impinging electrification is shown when the thinner are sprayed to drums. For the purpose of preventing the electrostatic discharge and damage, conductors should be ground, surface electric potential of should be decreased in using electrostatic shielding and ground, and flow of thinner should be controlled acceptable velocity.

  • PDF

정전 분무 간접 하전 방식에서 미세액적 최적 발생 조건에 관한 연구 (A Study on the Optimal Generation Conditions of Micro-Droplet in Electrostatic Spray Indirect Charging Method)

  • 이지희;김성환;정해영
    • 한국전기전자재료학회논문지
    • /
    • 제37권1호
    • /
    • pp.79-87
    • /
    • 2024
  • This paper is a study on the optimal microdroplet generation conditions in indirect charging electrostatic spraying. Unlike the direct charging method, which applies power to the nozzle, the indirect charging method applies power to the discharge electrode between the nozzle and the collection electrode. Therefore, an electrically simplified system can be obtained by minimizing the insulation part a stable spray pattern can be obtained with a wide spray angle, and a stable spray pattern can be obtained with a wide spray angle. To conduct the study, an indirect charging type electrostatic spray visualization system was constructed and the static characteristics of the microdroplets were analyzed through image processing of the spray shape of the microdroplets. The total number of microdroplets and the number of microdroplets per power consumption are confirmed according to the changes in the distance between the discharge electrode and the collection electrode, the flow rate, and the applied voltage, which affect the generation of microdroplets, and using this, the optimal generation conditions are derived and the corresponding microdroplet size distribution was analyzed. As a result of the experiment, it was confirmed that the optimal generation condition was at a flow rate of 15 to 20 mL/min and a voltage of -22.5 to -25 kV in terms of the number of microdroplets, and at a flow rate of 15 to 20 mL/min and a voltage of -20 kV in terms of energy consumption efficiency.

펄스 코로나 농약산포장치의 분무대전 특성 (Pulsed Corona Charging Characteristics of Aqueous Pesticide Spray)

  • 문재덕;이운태;배창환;권남열
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권9호
    • /
    • pp.388-394
    • /
    • 2003
  • Many toxic pesticides as aqueous-base sprays are dispensed for protection of food crops from pests into farm fields. When dispensed with conventional nozzles, a large portion of the spray is often lost by airborne drifts of droplets away and lack of deposition onto the plants due to rapid gravitational settling of droplets to the soil beneath. And target deposition efficiencies poorer than 20% are often encountered in agricultural pesticides. An electrostatic spraying technology offers a very favorable means to increasing pesticides droplets deposition onto biological surfaces of living crops. In this paper a corona type spray nozzle, utilizing a set of corona charging devices and a pulsed droplet-charging voltage applied, has been proposed and tested its potential experimentally. As a result, it exhibits a large current deposition of aqueous pesticide sprays on the sensing target, which, however, promise to be as one of the effective electrostatic spraying nozzle.

Photoluminescence Characteritics of Electrosprayed Eu(III) Doped Y2O3 Nanorods on a Si Substrate

  • 신원규;박미소;손영구
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.435-435
    • /
    • 2014
  • Eu(III)-doped Y2O3 nanorods were deposited onto a Si substrate using electrostatic spray system. The photoluminescence imaging profiles were compared between the electrospray film and powder form. Using electrostatic spraying technique is very advantageous to generate a uniform monolayer film without much clustering of nanorods. Strong emission peaks were observed between 580 and 730 nm in response to an indirect excitation transition. Our results indicate that the electrospray technique could be very useful for generating thin films for displays and sensors.

  • PDF

정전기 분무 열분해법에 의한 MgO 박막 증착과 AC-PDP로의 용용에 대한 연구 (Deposition of MgO Thin Films by Electrostatic Spray Pyrolysis(ESP) method and Application to AC-PDP)

  • 김수길;은재환;김형준;김영기;박정후
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 춘계학술대회 논문집 디스플레이 광소자 분야
    • /
    • pp.133-138
    • /
    • 2000
  • MgO thin films were deposited using $Mg(tmhd)_2$ as a precursor dissolved in a solvent by electrostatic spray pyrolysis. When a pure tetra hydro furan was used as a solvent, a large number of particles appeared on the MgO thin film surface due to homogeneous nucleation. However, by adding 1-butyl alcohol or 1-octyl alcohol to THF, homogeneous nucleation was restricted and the number density of the large particles was also drastically reduced. X-ray diffraction analysis showed that the MgO films had a (100) preferred orientation regardless of the type of solvents used. Characterization using Fourier Transformed-Infrared and spectroscopic photometer revealed that the crystallized MgO thin films on the glass substrate had a high optical transmittance (> 85 %) in the visible range. Discharge characteristics of MgO thin films deposited by ESP method on an alternating-current plasma display panel were compared with a MgO thin film prepared by reactive radio-frequency planar magnetron sputtering.

  • PDF