• 제목/요약/키워드: electrostatic precipitator (ESP)

검색결과 66건 처리시간 0.024초

공기정화용 소형 전기집진장치의 집진효율에 관한 연구 (A Study on Collection Efficiency of Compact and Small Size Air-Cleaning Electrostatic Precipitator)

  • Lee, S.H.;Yum, M.O.;Kang, K.O.
    • 한국정밀공학회지
    • /
    • 제14권1호
    • /
    • pp.84-89
    • /
    • 1997
  • Recentely, a compact and small size air-cleaning Electrostatic Precipitator(ESP) is needed to develop for air conditioning devices. From Deutsch formula for ESP efficiency, collection efficiency is affected not only the structure of collection section but also the charge rate of dust. In terms of collection area, the most useful type is a scroll type ESP. In this work, we investigated experimentally aptimum design factor of scroll type ESP by application of Taguchi method. And we developed the scroll type ESP by using optimal condition of control factor.

  • PDF

코로나 방전기가 없는 전기집진기의 나노입자 집진에 관한 수치해석 (NUMERICAL INVESTIGATION ON CAPTURE OF NANOPARTICLES IN ELECTROSTATIC PRECIPITATOR WITHOUT CORONA DISCHARGER)

  • 이진운;장재성;이성혁
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2010년 춘계학술대회논문집
    • /
    • pp.103-108
    • /
    • 2010
  • This article presents computational fluid dynamics (CFD) simulations of nanoparticle movements and flow characteristics in laboratory-scale electrostatic precipitator (ESP) without corona discharge, and for simulation, it uses the commercial CFD program(CFD-ACE) including electrostatic theory and Lagrangian-based equation for nanoparticle movement. For validation of CFD results, a simple cylindrical type of ESP is simulated and numerical prediction shows fairly good agreement with the analytical solution. In particular, the present study investigates the effect of particle diameter, inlet flow rate, and applied electric potential on particle collection efficiency and compares the numerical prediction with the experimental data, showing good agreement. It is found that the particle collection efficiency decreases with increasing inlet flow rate because the particle detention time becomes shorter, whereas it decreases with the increase in nanoparticle diameter and with the decrease of applied electric voltage resulting from smaller terminal electrostatic velocity.

  • PDF

와이어-평판 형태의 전기집진기식 바이오-에어로졸 포집기 성능 수치해석: 이온풍의 영향 (Numerical Analysis on Wire-Plate Electrostatic Precipitator Performance for Bioaerosol Capture: Effect of Ionic Wind)

  • 최현식;유기현;황정호
    • 한국입자에어로졸학회지
    • /
    • 제19권3호
    • /
    • pp.89-100
    • /
    • 2023
  • In our previous study, a wire-plate type electrostatic precipitator (ESP) was developed to collect bioaerosols of 100 nm size. In the study, various flow rates (40 ~ 100 L/min) and applied voltages (3 ~ 10 kV) were tested for experiment. In this study, numerical analysis was performed for the ESP of the previous study with the same flow rates and applied voltages, but with varying the size of bioaerosols to 0.04 ~ 2.5 ㎛. Overall, the numerical analysis results well predicted the experimental data. Bioaerosols of 0.1 ~ 0.5 ㎛ showed the minimum collection efficiency for all conditions because of low charge number. The effect of the ionic wind generated by the corona discharge was calculated. However, the ionic wind did not affect much the collection efficiency. The aerosol collection in the ESP of this study was due to the electrostatic force generated by particle charge in the electric field. This numerical study on the ESP can be used for the design and optimization of higher flow rate (> 100 L/min) ESP.

디젤엔진용 코로나 방전식 전기집진장치의 개발 과정에서의 배기 정화 성능에 관한 기초연구 (A Study on the Performances of Exhaust Gas Purification at Process on the Development of Corona Discharge Type Electrostatic Precipitator for Diesel Engines)

  • 손병호;배종욱
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권8호
    • /
    • pp.904-910
    • /
    • 2007
  • In this study an experimental research has been conducted to reduce NOx and smoke emission from diesel engine exhaust gas simultaneously by application of corona discharge type electrostatic precipitator(ESP). The ESP was installed between exhaust gas silencer and outlet terminal of exhaust gas system. The operating conditions as input parameters taken in this experiment were corona power input, gas velocity and equivalence ratio of gas. It was found that the corona discharge type ESP has notable effect on reducing smoke in exhaust gas but appeared to bring slight effect on reducing NOx.

타공판에 따른 전기집진기 내의 유동분포 (Flow Distribution in an Electrostatic Precipitator with a Perforated Plate)

  • 김동욱;정상현;심성훈;김진태;이상섭
    • 청정기술
    • /
    • 제25권2호
    • /
    • pp.147-152
    • /
    • 2019
  • 각종 산업시설과 발전시설에서 배출되는 입자상 물질의 문제로 인하여, 입자상 물질의 제거 효율이 뛰어난 전기집진기의 중요성이 증가하고 있다. 전기집진기의 효율은 전기집진기 내부의 유동분포에 매우 큰 영향을 받으므로, 전기집진기 내부의 유동 균일화를 위한 연구가 지속적으로 이루어지고 있다. 본 연구에서는 유입부, 디퓨저, 본체, 수축부로 구성된 길이 3.5 m, 높이 0.875 m 전기집진기를 제작하였다. 디퓨저에는 3개의 타공판을 설치하였다. 5개의 피토관을 높이 방향으로 부착하여 전기집진기 단면 55지점의 유속을 측정하였다. 디퓨저에 타공판이 설치되었을 때, 전기집진기 내부의 유동분포는 RMS%를 이용하여 평가하였다. 또한 타공판의 타공률 변화에 따른 유속분포도 분석하였다. 그 결과, 타공판이 전기집진기 내부의 유동분포에 미치는 영향이 매우 큼을 확인하였고, 디퓨저 입구에서부터 40%, 50%, 50% 타공률을 가진 타공판을 설치하였을 때, 가장 균일한 유동분포를 나타내었다.

전기집진기에서의 에어로졸 나노입자의 하전 및 집진 특성 연구 (Charging and Collection Characteristics of Aerosol Nanoparticles in an Electrostatic Precipitator)

  • 한방우;황순철;홍원석;정상현;김용진
    • 연구논문집
    • /
    • 통권34호
    • /
    • pp.21-28
    • /
    • 2004
  • In this study, we report an investigation for the charging and collection of aerosol nanoparticles in an electrostatic precipitator (ESP) according to particle charging and diffusion effects. The competition between charging probability and diffusion effect determines the collection efficiency of nanoparticles in the ESP. In conclusion, collection efficiency continuously decreased with the reduction in the particle size. This indicates that poor partial charging effect of nanoparticles is more dominant than their diffusion effect in the ESP for the nanoparticles in the particle size range of 4-20 nm. Theoretical calculations using a unipolar diffusion charing theory were in good agreement with the experimental data for the nanoparticles less than 20 nm in diameter.

  • PDF

Design and Experiment of an Electromagnetic Vibration Exciter for the Rapping of an Electrostatic Precipitator

  • Kim, Je-Hoon;Kim, Jin-Ho;Jeong, Sang-Hyun;Han, Bang-Woo
    • Journal of Magnetics
    • /
    • 제17권1호
    • /
    • pp.61-67
    • /
    • 2012
  • The miniaturization of an electrostatic precipitator has become a key element in successfully constructing an efficient electrostatic precipitator because of the limited space allowed for installation in a subway tunnel. Therefore, the miniaturization of the rapping system of the electrostatic precipitator has also become important. This research proposes a resonant-type electromagnetic vibration exciter as a vibrating rapper for an electrostatic precipitator. The compact vibrating rapper removes collected dust from the collecting plates without direct impact on those collecting plates. To characterize the dynamic performance of the electromagnetic vibration exciter, finite element analysis was performed using a commercial electromagnetic analysis program, MAXEWLL. Moreover, we analyzed the resonant frequency of an electrostatic precipitator, to which the electromagnetic vibration exciter was applied, by ANSYS. Also, to measure the acceleration generated by the electromagnetic vibration exciter, we manufactured a prototype of the ESP and electromagnetic vibration exciter and measured its acceleration at the resonant frequency.

주거건물용 이중외피 통합형 전기집진기의 미세먼지 집진성능 수치해석 평가 (Numerical Study of Particle Collection Performance of Electrostatic Precipitator Integrated with Double Skin Façade in Residential Buildings)

  • 엄예슬;최동희;강동화
    • 대한건축학회논문집:구조계
    • /
    • 제34권12호
    • /
    • pp.73-82
    • /
    • 2018
  • The objective of this study was to evaluate particle collection performance of electrostatic precipitator (ESP) integrated with double skin façade in naturally ventilated residential buildings using numerical method. To evaluate the efficiency, computational fluid dynamics (CFD) simulation based on electric potential and Lagrangian method was applied. The CFD model was validated by comparing the simulated results with the experimental data including thermal characteristic of double skin façade (DSF) and particle removal characteristic of electrostatic precipitator. The validation results showed that the root mean square error (RMSE) between predicted values and measured values of velocity and temperature in intermediate space of DSF was 1.2%. The adequacy of ion space charge density and turbulent model were determined. The RMSE between predicted values and measured values of collection efficiency of ESP was 9.2%. In addition, the case study was performed to present the application of the numerical method based on validation results of ESP integrated with façade.

Removal of Serratia marcescens Aerosols Using an Electrostatic Precipitator Air-Cleaner

  • Ko, Gwang-Pyo;Burge, Harriet
    • Journal of Microbiology and Biotechnology
    • /
    • 제17권10호
    • /
    • pp.1622-1628
    • /
    • 2007
  • We characterized the efficacy of an electrostatic precipitator (ESP) air-cleaner in reducing the concentration of Serratia marcescens in an enclosed space. We used an experimental room ($4.5{\times}3{\times}2.9\;m$) in which electrostatic air-cleaners were located. Two air-cleaners enhanced the equivalent ventilation rates in the chamber by about 3.3 air changes per hour (ACH) over the 2 ACH provided by the mechanical ventilation system. Natural die-off of the organisms provided an additional equivalent of 3 ACH, so that the total ventilation rate with the ESP air-ccleaners was 8.3 ACH. We also examined whether the ESP air-cleaners altered the deposition of Serratia marcescens aerosols on the experimental room surfaces. We did not find any significant differences in the number of colony forming units recovered from surfaces with and without the air-cleaners. We installed UV lights inside the ESPs and determined if UV light, in addition to electrical fields, increased the efficacy of the ESPs. The presence of UV light inside the ESP reduced S. marcescens aerosols by approximately 2 ACH. Finally, a box model indicates that the efficiency of the air-cleaner increases for both biological and nonbiological particles at ventilation rates of 0.2-1, which are typical for residential settings.

전기집진기 (ESP) 덕트 내부 유동 균일화를 위한 연구 (Optimization of Flow Uniformity in an Electrostatic Precipitator (ESP) Duct)

  • 홍준형;황민승;한종호;최웅철;성정모;황원태
    • 한국가시화정보학회지
    • /
    • 제20권3호
    • /
    • pp.86-93
    • /
    • 2022
  • An electrostatic precipitator (ESP) is an industrial post processing facility for high efficiency dust mitigation. Uniformity of the flow passing through the inlet duct leading into the main chamber is important for efficient reduction of dust. To examine flow uniformity, this study conducted a numerical analysis of the flow within a scale-down ESP inlet duct. Magnetic resonance velocimetry (MRV) results from a prior study were utilized to validate the Reynolds-averaged Navier-Stokes (RANS) numerical simulations. Both the experimental and computational results displayed a similar recirculation zone shape and normalized velocity profile near the duct outlet for the baseline geometry. To optimize the uniformity of the flow, the number of guide vanes was modified, and the guide vanes were partially extended straight upward. Design evaluation is done based on the outlet velocity distribution and mass flowrate balance between the two outlets. Simulation results indicate that the vane extension is critical for flow optimization in curved ESP ducts.