• 제목/요약/키워드: electrostatic precipitator

검색결과 198건 처리시간 0.024초

정전분무 방전극을 이용한 습식 전기집진장치의 미세먼지 집진효율 평가 (Evaluation of Particle Collection Efficiency in a Wet Electrostatic Precipitator Using an Electrosprayed Discharge Electrode)

  • 김홍직;김종현;김종호
    • 한국대기환경학회지
    • /
    • 제31권6호
    • /
    • pp.530-537
    • /
    • 2015
  • The wet electrostatic precipitator (wet ESP) is an effective control device which removes submicron particles reentrained in a collection plate and water soluble gas. However, its collection efficiency decreases, as its operation is subject to water-induced distortion of the collection electrode. In order to make up for the limitation, we modified the wet ESP system by installing electrosprayed discharge electrodes. The modified wet ESP system can wash both the collection plate and discharge electrode. As a result, we were able to fabricate a compact wet ESP with a small specific collecting area ($0.18m^2(m^3/min)$) that can accomplish a high collection efficiency of fine particles (97.1%). In addition, the device obtained a relatively low specific corona power of approximately $10W/(m^3/min)$.

Bunkder C유 회분의 물리적, 화학적, 전기적 특성분석 (A Characteristic Analysis of Physical, Chemical and Electrical Property for Bunker C Fly Ash)

  • 이재근;이정언;안영철
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1996년도 춘계학술발표회 초록집
    • /
    • pp.88-96
    • /
    • 1996
  • The characteristic analysis of fly ash generated from a fired power plant using bunker-C oil has been investigated. Ash size distribution by an optical microscopy with image processing technique, morphological shape by a scanning electron microscope(SEM) and microscope, chemical composition by the inductively coupled plasma emission spectrometry(ICP), and resistivity measurement as a function of temperature and moisture content by the resistivity meter are performed. A study of physical, chemical and electrical characteristics of bunker-C fly ash plays an important role of improving the performance of an electrostatic precipitator and protecting air pollution. The samples of bunker-C fly ash for analysis were collected from the electrostatic precipitator hopper of Ulsan Power Plant Unit 1 and Pusan Power Plant Unit 1. Mass median diameter(MMD) of bunker-C fly ash was measured 12.7${\mu}{\textrm}{m}$, while MMD of fly ash generated from the mixture of bunker-C oil(40%) and domestic anthracitic coal(60%) was 25.7${\mu}{\textrm}{m}$. The morphological structure of bunker-C fly ash consisted of fine particles of non-spherical shape. The primary chemical components of bunker-C fly ash were composed of SiO2(2.36%), Al2O3(4.91%), Fe2O3(14.33%) and C(11.84%). Resistivity of bunker-C fly ash was found to be increased with increasing temperature at the range of 100~15$0^{\circ}C$ and was measured 103~104 ohm-cm.

  • PDF

A Numerical Study on the Triboelectrostatic Separation of PVC Materials From Mixed Plastics for Waste Plastic Recycling

  • Ha, Man-Yeong;Jeon, Chung-Hwan;Park, Doo-Seong;Park, Hae-Jin
    • Journal of Mechanical Science and Technology
    • /
    • 제17권10호
    • /
    • pp.1485-1495
    • /
    • 2003
  • We investigate the triboelectrostatic separation of polyvinylchloride (PVC) from mixed plastics in the laboratory scale triboelectrostatic separation system. The flow and electric fields in the precipitator are obtained from the numerical solution of finite volume method. Using these flow and electric fields, we solved the particle motion equation considering the inertia, drag, gravity and electrostatic forces acted on the particles. The particle trajectories are obtained using a Lagrangian method as a function of different important variables such as Reynolds number, Stokes number, electrostatic force, electric charge and electric field distribution, inclined angle of plane electrodes, particle rebounding, particle charge decay rate after impact on the electrode surface, etc., in order to determine the optimal design conditions. The present predicted results for the cumulative yield represent well the experimental ones.

지하전철 구간의 미세먼지 제거를 위한 전기집진기 개발에 관한 연구 (A study on the Electrostatic Precipitator evolution for PM-10 elimination of subway station)

  • 노성찬;김윤호;김수홍;이수원;유광균
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 춘계학술대회 논문집
    • /
    • pp.1482-1485
    • /
    • 2004
  • Electrostatic Precipitators have been used widely in industry, and play an important role in environmental protection. Electrostatic Precipitators (ESP) can be operated with a high collection efficiency and low pressure drop. Pulse energization is a technique to cope with high resistivity dust, and this results in lower power consumption. In this paper, Pulse energization ESP to use subway station air clean in subway station, design and test a pulse power supply for ESP.

  • PDF

전기집진기의 10 nm 급 초미세 나노입자의 하전 및 집진 특성 (Characteristics of Charging and Collection of 10-nm-Class Ultrafine Nanoparticles in an Electrostatic Precipitator)

  • 한방우;김학준;김용진;송동근;홍원석;신완호
    • 대한기계학회논문집B
    • /
    • 제35권10호
    • /
    • pp.1013-1018
    • /
    • 2011
  • 전기집진에서의 10 nm 급 초미세 나노입자의 하전 및 집진 특성을 파악하였고, 나노입자의 확산효과와 비교해 보았다. 나노입자의 하전율과 확산손실 효과의 지배력에 따라 전기집진기에서의 나노입자 집진효율이 결정되는 것을 확인할 수 있었다. 10nm 급 영역에서는 입자 크기가 작아질수록 지속적으로 집진효율이 감소하였다. 10 nm 이하의 영역에서는 나노입자의 부분적 하전효과가 전기집진기 내의 확산 손실 효과보다 지배적인 것을 알 수 있었다. 10 nm 이하의 나노입자에 대하여 집진효율 실험 결과가 단극 확산 하전 이론을 적용한 입자하전율 계산 결과와도 잘 일치하였다.

오픈 소스 전산 유체 역학 해석 프로그램을 이용한 전기집진기 내부 정전 유동 해석 (Numerical Analysis of Electro-Hydrodynamic (EHD) Flows in Electrostatic Precipitators using Open Source Computational Fluid Dynamics (CFD) Solver)

  • 송동근;홍원석;신완호;김한석
    • 한국입자에어로졸학회지
    • /
    • 제9권2호
    • /
    • pp.103-110
    • /
    • 2013
  • The electrostatic precipitator (ESP) has been used for degrading atmospheric pollutants. These devices induce the electrical forces to facilitate the removal of particulate pollutants. The ions travel from the high voltage electrode to the grounded electrode by Coulomb force induced by the electric field when a high voltage is applied between two electrodes. The ions collide with gas molecules and exchange momentum with each other thus inducing fluid motion, electrohydrodynamic (EHD) flow. In this study, for the simulation of electric field and EHD flow in ESPs, an open source EHD solver, "espFoam", has been developed using open source CFD toolbox, OpenFOAM(R) (Open Field Operation and Manipulation). The electric potential distribution and ionic space charge density distribution were obtained with the developed solver, and validated with experimental results in the literature. The comparison results showed good agreement. Turbulence model is also incorporated to simulate turbulent flow; hence the developed solver can analyze laminar and turbulent flow. In distributions of electric potential and space charge, the distributions become distorted and asymmetric as the flow velocity increases. The effect of electrical drift flow was investigated for different flow velocities and the secondary flow in a flow of low velocity is successfully predicted.

직화구이 음식점 방지시설의 오염물질 저감 효과 평가 - 전기집진방식을 중심으로 - (Evaluation of Removal Efficiency in Emission Pollutants by Air Pollution Prevention Facilities from Meat Grilled Restaurants - Focus on the Electrostatic Precipitator -)

  • 서장원;김영일;이희선;김지훈;김영두;신진호
    • 한국입자에어로졸학회지
    • /
    • 제17권4호
    • /
    • pp.115-123
    • /
    • 2021
  • The emission gas from meat grilled restaurants has unpleasant odor and sticky particulate matters (PM) in form of oil mist. This affects the residents living nearby. In oder to decrease the odor and PM, electrostatic precipitators (ESP) were installed at several restaurants by support of Seoul metropolitan government and emission characteristics of PM and odor were investigated. The removal efficiency of odor and PM at before- and after-ESP was that total hydrocarbon (THC), NH3, H2S, acetaldehyde, butyraldehyde were not much decreased. Total suspended particles (TSP) emitted from the vent was below the value of 7 mg/m3 regardless of the concentration of before-ESP and removal efficiency was in the range of 64 ~ 86%. The ratio of PM1.0 to PM10 of emission gas was over 0.9. So it was revealed that most PM of emission gas was PM1.0. The PM concentration in the air of the street near the vent was higher than another street due to the emission gas and the PM of indoor air of restaurant grilling meats was measured very high compared to outdoor air. So it needs more powerful ventilation of indoor air.

전기역학적 스크린을 이용한 집진판 표면 위 입자 세정성능 연구 (A study on cleaning performance of particles on collection plates using an electrodynamic screen)

  • 조윤희;신동호;김영훈;박인용;김상복;이건희;한방우
    • 한국입자에어로졸학회지
    • /
    • 제19권3호
    • /
    • pp.63-76
    • /
    • 2023
  • An electrostatic precipitator (ESP) has a low pressure drop and a high collection efficiency but its collection efficiency can be reduced due to dust accumulation on the collection plates during long-term operations. In order to maintain the initial dust collection efficiency, it is necessary to periodically clean the collection plates. The common cleaning methods are using physical impacts or water sprays. These cleaning methods can lead to damage to the collection plate or generate wastewater. Herein, we implemented an electrodynamic screen (EDS) for ESP cleaning and evaluated its surface cleaning performance of particles. The EDS is an electrostatic system that can electrostatically repel particles on surfaces, allowing it to clean the ESP without causing damage and wastewater generation. Our evaluation included the analysis of the effects of AC voltage characteristics, electrode configuration and environmental conditions on the cleaning performance of the EDS with the aim of achieving effective surface cleaning. It has been demonstrated that activating the EDS cleans up to 65% of the particles on the surface, which indicates about 94% of our target cleaning zone.

정전 방식 디젤 PM 포집 장치 성능 및 엔진 적용성 평가 (Evaluation on Performance of an Electrostatic Diesel PM Trap Device and Its Application to Diesel Engine After-treatment)

  • 김학준;한방우;김용진
    • 한국자동차공학회논문집
    • /
    • 제16권6호
    • /
    • pp.176-183
    • /
    • 2008
  • Performance of electrostatic diesel PM filtration systems (E-DPS) with different types has been tested using the carbon particles generated by spark discharge in laboratory. Among the five electrostatic precipitators, the multiple wires cylindrical E-DPS with the highest collection efficiency and relatively lower differential pressure at the flow rate of $1\;m^3$/min, as an applicable device to diesel engine as an after treatment system, has been combined with another collection cylinder to improve the collection efficiency of diesel particulate matters generated from diesel engines. The multiple wires cylindrical E-DPS combined with the cylindrical collector showed the collection efficiency of more than 60% at the engine speed of 2,000 rpm with the engine loads of 25 and 50%.

트리에틸아민 첨가에 따른 열병합발전소 전기집진장치의 집진효율 특성의 현장 평가 (Field Evaluation of Particulate Control Efficiency of Electrostatic Precipitator in Thermoelectric Power Plant Associated with Addition of Triethyl Amino(TEA))

  • 조완근;전옥상
    • 대한환경공학회지
    • /
    • 제27권4호
    • /
    • pp.445-449
    • /
    • 2005
  • 본 연구의 목적은 실제 가동 장치에 연결된 전기집진장치의 제거효율을 향상시키기 위하여 주입되는 트리에틸아민 주입 조건에 대한 실제 장치의 효능을 평가하는 것이다. 국내 발전소에서는 주로 호주, 중국, 남아프리카 및 미국에서 수입되는 비스무스 석탄을 이용하는데 비록 이러한 수입 석탄의 종류에 따라 발생되는 비산재의 전기저항도값이 다소 차이가 있지만, 석탄 연소시 배출되는 비산재의 대표적인 전기저항도값은 $1{\times}10^{12}\;{\Omega}-cm$ 큰 것으로 나타났다. 이 때문에 국내 대부분의 적기집진기 가동시 백 코로나 문제가 빈번하게 나타난 것으로 확인되었다. 전기집진장치 출구에서 직접 측정된 분진의 농도, 매연도 및 분진의 전기저항도와 집진효율을 동시에 확인한 결과에 따르면, 트리메틸아민의 주입이 전기집진장치의 집진효율을 상당량 증가시키는 것으로 확인되었다. 트리에틸아민 주입 전에 비산재의 전기저항도값이 $1.9{\times}10^{12}\;{\Omega}-cm$이던 것이 15 ppm(순도 99.7%) 주입시 비산재의 전기저항도값이 $2.1{\times}10^{11}\;{\Omega}-cm$으로 감소하였다. 이러한 조건에서 연돌에서 배출되는 분진의 배출량은 대략 80% 정도 감소율을 나타내며 농도 대비 $70\;mg/Sm^3$ to $14\;mg/Sm^3$수준이었다.