Field Evaluation of Particulate Control Efficiency of Electrostatic Precipitator in Thermoelectric Power Plant Associated with Addition of Triethyl Amino(TEA)  

Jo, Wan-Kuen (Department of Environmental Engineering, Kyungpook National University)
Jeon, Ok-Sang (Gumi Thermoelectric Power Plant)
Publication Information
Abstract
Present study was designed to evaluate the practical application of triethyl amine(TEA) injection for improving the collection efficiency of electrostatic precipitator(ESP) connected to a real operating plant. The major fuels used at the domestic power stations were bituminous coals imported from Australia, China, South Africa, and USA. Although the values of the electric resistance would be more or less different according to the type of the coals used, the unique electric resistance values of fly ash from the coals were mostly higher than $1{\times}10^{12}\;{\Omega}-cm$ and therefore, back corona problems were always expected to occur in the electrostatic precipitator. The particulates concentrations, smoke concentrations and their electric resistivity measured at the outlet of ESP, and the inspection of collection indicated that the injection of TEA improved the collection efficiency of particulate at collection plates of ESP. The electric resistance for, fly ash with the injection concentration of TEA 15 ppm(Purity 99.7%) was lowered to $2.1{\times}10^{11}\;{\Omega}-cm$ after injection from $1.9{\times}10^{12}\;{\Omega}-cm$ before injection. Under this condition, the dust emission content at the stack was reduced to approximately 80%, lowering the average outlet concentrations of particulates from $70\;mg/Sm^3$ to $14\;mg/Sm^3$.
Keywords
Collection Efficiency; Electric Resistivity; Real Plant; Bituminous Coal; Smoke; Fly Ash;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Tsai, C. J., Miao, C. C., and Lu, H. C., 'White smoke emission from a semiconductor manufacturing plant,' Environ. Int., 23, 489-496(1997)   DOI   ScienceOn
2 Schmidt, W. A. and Flodin, C. R., 'Fundamental Principles, Design, Application, Performance, and Limitations of Electrical Precipitation Equipment,' In: United States Conference on Air Pollution, May 3-5, 1950. Washington, D.C. L.C. McCabe, Chairman. McGraw-Hill Book Co., New York, N.Y.(1952)
3 Riehle, C. and Loffler, F., 'The effective migration rate in electrostatic precipitator,' Aerosol Sci. Technol., 6, 1-14(1992)
4 Zhibin, Z. and Guoquan, Z., 'New model of electrostatic precipitation efficiency accounting for turbulenet mixing,' J. Aerosol Sci., 23, 115-121(1992)   DOI   ScienceOn
5 한국산업단지공단, '구미열병합발전소 발전연보, 유연탄 탄종별 사용 현황,' 한국산업단지공단(1996)
6 U.S. Environmental protection Agency, 'Air Pollution Engineering Manual,' Office of Air and Water programs, research Triangle Park, N.C. 27711(1991)
7 Bai, H. and Chang, C. L., 'A model to predict the system performance of an electrostatic precipitator for collecting polydisperse particles,' J. Air Waste Manage. Assoc., 45, 908-916(1995)   DOI   ScienceOn
8 한재균, 최금찬, '연소장치를 이용한 소형 전기집진장치의 집진효율에 관한 연구,' 한국대기보전학회지, 9, 125-131(1993)
9 한국산업단지공단, '구미열병합발전소 발전연보, 유연탄 탄종별 사용 현황,' 한국산업단지공단(1997)
10 전옥상, '트리에틸아민 조질 첨가제 사용에 따른 집진 효율 변화특성,' 경북대학교, 석사학위논문(2000)
11 한국산업단지공단, '구미열병합발전소 발전연보, 유연탄 탄종별 사용 현황,' 한국산업단지공단(1998)
12 Varonos, A. A., Anagnostopoulos, J. S., and Bergeles, G. C., 'Prediction of the cleaning efficiency of an electrostatic precipitator,' J. Electrostatics, 55, 111-133 (2002)   DOI   ScienceOn
13 환경실무, '한국전력공사 삼천포연수원 A-I-1,'(1998)
14 Jedrusik, M., Swierczok, A., and Teisseyre, A, 'Experimental study of fly ash precipitation in a model electrostatic precipitator with discharge electrodes of different design,' Powder Technol., 135, 295-301(2003)   DOI   ScienceOn
15 Zhibin, Z. and Guoquan, Z., 'Investigation of the collection efficiency of an electrostatic precipitator with turbulene effects,' Aerosol Sci. Technol., 20, 169-176 (1994)   DOI   ScienceOn
16 화력발전소 환경종합 대책수립(II) p. 50-67(1991)
17 SinSang Plant Co., 'Performance Calculation of Electrostatic Precipitator for Kumi Co-Gen Plant,' Kumi CoGen Plant Coal Ultimate Analysis Report of the Coal Research Institute of Korea Coal Corporation 1998. 12(1991)