• Title/Summary/Keyword: electrostatic analysis

Search Result 384, Processing Time 0.029 seconds

Performance Analysis and Modifications of Axi-Symmetric Electrostatic Lens for Sub-Micron Ion Beam System (Sub-micron의 이온빔 직경을 가지는 축대칭 정전렌즈의 성능 해석 및 개선)

  • 이종현;배남진;김보우
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.9
    • /
    • pp.1348-1358
    • /
    • 1989
  • We analyzed electrostatic lens with axi-symmetic configurations using the analytic equation for a single apertured lens. The developed computer code afforded to estimate ion optical properties such as ion trajectories, aberrations and ion beam diameters, and was found to have advantages of a shorter calculation time. The calculated ion optical properties for several types of electrostatic lens were in good agreement with Burghard's ones and it was seem that 20% reduction of ion beam diameter could be obtained by the change of aperture diameters.

  • PDF

The Analysis of Electrostatic Contour Distribution in a Polymer Electret Acoustic Sensor Using Finite Element Method (유한요소법을 이용한 고분자 일렉트렛트 음향센서의 전위분포 해석)

  • Jang, In-Beom;Lee, Su-Kil;Jung, Il-Hyung;Lee, Joon-Ung
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.398-400
    • /
    • 1995
  • In this Study, the Electrostatic Coutour Distribution in Polymer Electret Acoustic Sensor is calculated using Finite Element Method. As a result, the Electrostatic Countour Distribution is visualized and the design modification could be processed.

  • PDF

Analysis on particle deposition onto a heated, horizontal free-standing wafer with electrostatic effect (정전효과가 있는 가열 수평웨이퍼로의 입자침착에 관한 해석)

  • Yoo, Kyung-Hoon;Oh, Myung-Do;Myong, Hyon-Kook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.10
    • /
    • pp.1284-1293
    • /
    • 1997
  • The electrostatic effect on particle deposition onto a heated, Horizontal free-standing wafer surface was investigated numerically. The deposition mechanisms considered were convection, Brownian and turbulent diffusion, sedimentation, thermophoresis and electrostatic force. The electric charge on particle needed to calculate the electrostatic migration velocity induced by the local electric field was assumed to be the Boltzmann equilibrium charge. The electrostatic forces acted upon the particle included the Coulombic, image, dielectrophoretic and dipole-dipole forces based on the assumption that the particle and wafer surface are conducting. The electric potential distribution needed to calculate the local electric field around the wafer was calculated from the Laplace equation. The averaged and local deposition velocities were obtained for a temperature difference of 0-10 K and an applied voltage of 0-1000 v.The numerical results were then compared with those of the present suggested approximate model and the available experimental data. The comparison showed relatively good agreement between them.

Numerical Analysis on Wire-Plate Electrostatic Precipitator Performance for Bioaerosol Capture: Effect of Ionic Wind (와이어-평판 형태의 전기집진기식 바이오-에어로졸 포집기 성능 수치해석: 이온풍의 영향)

  • Hyun Sik Choi;Gihyeon Yu;Jungho Hwang
    • Particle and aerosol research
    • /
    • v.19 no.3
    • /
    • pp.89-100
    • /
    • 2023
  • In our previous study, a wire-plate type electrostatic precipitator (ESP) was developed to collect bioaerosols of 100 nm size. In the study, various flow rates (40 ~ 100 L/min) and applied voltages (3 ~ 10 kV) were tested for experiment. In this study, numerical analysis was performed for the ESP of the previous study with the same flow rates and applied voltages, but with varying the size of bioaerosols to 0.04 ~ 2.5 ㎛. Overall, the numerical analysis results well predicted the experimental data. Bioaerosols of 0.1 ~ 0.5 ㎛ showed the minimum collection efficiency for all conditions because of low charge number. The effect of the ionic wind generated by the corona discharge was calculated. However, the ionic wind did not affect much the collection efficiency. The aerosol collection in the ESP of this study was due to the electrostatic force generated by particle charge in the electric field. This numerical study on the ESP can be used for the design and optimization of higher flow rate (> 100 L/min) ESP.

Development of a Comb-parallel Type Micro Actuator with High Aspect Ratio (높은 세장비의 Comb-parallel 타입 마이크로 액츄에이터의 개발)

  • 이승재;조동우;김종영
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.848-853
    • /
    • 2001
  • Electrostatic actuation was adopted for ease of fabrication. We proposed a new driving scheme that uses the vector sum of force generated by comb-finger and by parallel plate. The moving and fixed electrodes are arranged to maximize the driving force. In this paper, an electrostatic field analysis is performed by Maxwell analysis tool for micro actuators. From the analysis, a comb-parallel type micro-actuator with 4${\mu}{\textrm}{m}$ width, 6${\mu}{\textrm}{m}$ overlap and 45${\mu}{\textrm}{m}$ height could be designed. In order to compare the new type of actuator with the conventional comb type of actuator, we arranged that both types have the same area and the same number of actuators. To make a high aspect ratio structure, we are developing fabrication process using SU-8 and electro-plating.

  • PDF

Dynamic analysis of charged human body electrostatic discharge - comparison with quasi-static discharge (대전인체의 정전기 방전에 대한 동적해석 - 준정적해석과의 비교)

  • 이종호;김두현;김상철;김상렬
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 1998.05a
    • /
    • pp.257-262
    • /
    • 1998
  • In order to understand the characteristics of electrostatic discharge (ESD) by a charged human body, a dynamic analysis method based on RCL circuit and a quasi-static analysis method based on two-body model are introduced. In this paper, these methods calculate waveforms, discharge energy and potential difference to analyze the ESD phenomena from given initial conditions and geometry. Results are compared and discussed.

  • PDF

Skewed Electrode Array(SEA) and Its Application as an Angular Microactuator (경사 전극 배열을 이용한 각도방향 마이크로 구동부 제작)

  • Choi, Seok-Moon;Park, Sung-Jun
    • Journal of Institute of Convergence Technology
    • /
    • v.1 no.2
    • /
    • pp.16-24
    • /
    • 2011
  • The angular electrostatic microactuator using skewed electrode array (SEA) scheme was proposed. The moving and fixed electrodes are arranged to make the driving force perpendicular to the rotating moment of arm. By changing the electrode overlap length, the magnitude of electrostatic force and stable displacement will be changed. In order to optimize the design, electrostatic FE analysis were carried out and the empirical force model was established for SEA. Simulation was performed to make the comparison between conventional actuators and SEA. The proposed SEA generates actuating torque 2 times greater than a comb-drive and stable actuator displacement 40% greater than a parallel plate type actuator. The angular electrostatic microactuator using skewed SEA scheme was designed and fabricated using SoG process.

  • PDF

Solvent Effect on the Dynamics of Radical Ion Pair Separation

  • Han, Chul-Hee
    • Journal of Photoscience
    • /
    • v.8 no.1
    • /
    • pp.33-37
    • /
    • 2001
  • Picosecond absorption spectroscopy has been employed in the study of the solvent dynamics of 1, 2, 4, 5-tetracyanobenzene/biphenyl derivative radical ion pairs, and the resulting rates of radical ion pair separation are faster in acetonitrile than in dichloromethane. In an effort to account quantitatively for such solvent effect on the rate of radical ion pair separation, an equation for the rate of radical ion pair separation is introduced, in which the rate depends exponentially on the electrostatic interaction energy in the radical ion pair. In our analysis of the types of electrostatic interaction energy based on the conducting spheres in dielectric continuum was chosen, and the rate equation employing this electrostatic energy provided information on the distance on the distance of radical ion pair separation and solvation energy of the radical ion pair, thereby providing quantitative explanation for the observed solvent effect on the rate of radical ion pair sepaaration.

  • PDF

Analysis of Micromechanical Characteristics of Microactuator Materials Using the Electrostatic Force (정전기력을 이용한 마이크로 액츄에이터 소지의 미소 기계적 구동특성 분석)

  • Lee, Se-Ho;Kim, Jae-Sug;Son, Dong-Il;Pak, Yu-Keun;Kwon, Dong-Il
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3286-3288
    • /
    • 1999
  • The electrostatically actuated test structure was presented to measure the micro mechanical characteristics of micromaterials as thin films forming the microactuators. The test structure was fabricated by the surface micromachining processes and driven by the electrostatic force, In order to measure the fracture toughness, the sharp notch in the test structure was introduced by the etching process. On the basis of the beam bending theory, the elastic modulus was measured by using the microcantilevr beam and the mechanical displacement, curvature and deflection curve under the electrostatic force was evaluated by using the electrostatic structure.

  • PDF