• 제목/요약/키워드: electrospray ionization (ESI)

검색결과 186건 처리시간 0.021초

Profiling of the leaves and stems of Curcuma longa using LC-ESI-MS and HPLC analysis

  • Gia Han Tran;Hak-Dong Lee;Sun-Hyung Kim;Seok Lee;Sanghyun Lee
    • Journal of Applied Biological Chemistry
    • /
    • 제66권
    • /
    • pp.338-344
    • /
    • 2023
  • Curcuma longa is a plant belonging to the genus Curcuma and is distributed across various Asian regions. This plant is widely known for its rhizomes, which possess a variety of pharmacological properties. However, although the leaves and stems of this plant also contain several health-promoting secondary metabolites, very few studies have characterized these compounds. Therefore, our study sought to quantify the secondary metabolites from the leaves and stems of Curcuma longa L. (LSCL) using liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS) and high-performance liquid chromatography (HPLC). Our LC-ESI-MS analyses detected twenty-one phenolic compounds in the LSCL, among which fifteen compounds were detected via HPLC analysis. Four compounds, namely vanillic acid (0.129 mg/g), p-coumaric acid (0.431 mg/g), 4-methylcatechol (0.199 mg/g), and afzelin (0.074 mg/g) were then quantified. These findings suggest that LSCL is rich in secondary metabolites and holds potential as a valuable resource for the development of functional and nutritional supplements in the future.

A Simple and Sensitive High Performance Liquid Chromatography-Electrospray Ionization/Mass Spectrometry Method for the Quantification of Ethyl Pyruvate in Rat Plasma

  • Kim, Hyun-Ji;Kim, Seung-Woo;Lee, Ja-Kyeong;Yoon, Sung-Hwa
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권4호
    • /
    • pp.1221-1227
    • /
    • 2011
  • Ethyl pyruvate (EP) is known as a scavenger of reactive oxygen species (ROS) in the body through its role in the donation of diketone groups to metals to form an EP-metal complex. In order to develop a method for the quantification of EP in biological media, a sensitive and specific, high-performance liquid chromatographyelectrospray ionization-mass spectrometry (HPLC-ESI/MS) method is used to determine the EP-alkali metal ion binding species. The analyte was separated on a ZORBOX SB-C8 ($3.5{\mu}m$, $30mm{\times}2.1mm$ I.D.) column and analyzed in selected ion monitoring (SIM) mode with a positive ESI interface using the m/z 255 $[2M + Na]^+$ ion. The method was validated over the concentration range of $0.5-60.0\;{\mu}g$/mL under 1/9 (v/v) of acetonitrile/methanol solvent system with flow rate 0.05 mL/min. The limit of quantification (LOQ) was $0.5{\mu}g$/mL.

The Influence of Mixed Solvents Volatility on Charge State Distribution of Peptides During Positive Electrospray Ionization Mass Spectrometry

  • Nielsen, Birthe V.;Abaye, Daniel A.;Nguyen, Minh T.L.
    • Mass Spectrometry Letters
    • /
    • 제8권2호
    • /
    • pp.29-33
    • /
    • 2017
  • Understanding the mechanisms that control and concentrate the observed electrospray ionisation (ESI) response from peptides is important. Controlling these mechanisms can improve signal-to-noise ratio in the mass spectrum, and enhances the generation of intact ions, and thus, improves the detection of peptides when analysing mixtures. The effects of different mixtures of aqueous: organic solvents (25, 50, 75%; v/v): formic acid solution (at pH 3.26) compositions on the ESI response and charge-state distribution (CSD) during mass spectrometry (MS) were determined in a group of biologically active peptides (molecular wt range 1.3 - 3.3 kDa). The ESI response is dependent on type of organic solvent in the mobile phase mixture and therefore, solvent choice affects optimal ion intensities. As expected, intact peptide ions gave a more intense ESI signal in polar protic solvent mixtures than in the low polarity solvent. However, for four out of the five analysed peptides, neither the ESI response nor the CSD were affected by the volatility of the solvent mixture. Therefore, in solvent mixtures, as the composition changes during the evaporation processes, the $pK_b$ of the amino acid composition is a better predictor of multiple charging of the peptides.

HPLC/DAD/ESI-MS를 이용한 혈장시료 중 갑상선 호르몬 분석 (Determination of thyroid hormones in plasma samples by high performance liquid chromatograph/diode array detector/electrospray ionization mass spectrometer)

  • 곽선영;문명희;표희수
    • 분석과학
    • /
    • 제20권5호
    • /
    • pp.424-433
    • /
    • 2007
  • 혈장시료 중의 갑상선 호르몬을 고체상 추출법을 이용하여 추출한 후 HPLC/DAD/ESI-MS (high-performance liquid chromatograph/diode array detector/electrospray ionization-mass spectrometer)를 사용하여 분석하였다. 7종의 thyroid hormones의 HPLC 분리조건은 Hypersil ODS 컬럼(4.6 mm I.D., 250 mm length, particle size $5{\mu}m$)을 사용하고 ammonium formate buffer와 아세토나이트릴을 이동상으로 하여 기울기 용리한 결과 완전 분리가 가능하였으며, UV spectra 및 질량스펙트럼을 확인할 수 있었다. 고체상추출법에 의한 전처리 최적 조건을 조사한 결과 시료를 pH 3으로 한 후 C18 고체상을 사용하여 4 mL의 메탄올로 용리할 경우 회수율이 74.5-115.7%로 나타났다. HPLC/ESI-MS를 이용하여 20-500 ng/mL범위에서 검량선을 작성한 결과 $r^2$값은 0.9939-0.9978으로 나타났으며 검출한계는 20-50 ng/mL (38.1-162.8 pmol/mL)로 계산되었다. 정상인의 혈장에서 thyroxine의 정량이 가능하였으며 그 결과 50.98-112.97 ng/mL로 검출되었다.

Phospholipid Analysis by Nanoflow Liquid Chromatography-Tandem Mass Spectrometry

  • Moon, Myeong Hee
    • Mass Spectrometry Letters
    • /
    • 제5권1호
    • /
    • pp.1-11
    • /
    • 2014
  • Lipids play important roles in biological systems; they store energy, play a structural role in the cell membrane, and are involved in cell growth, signal transduction, and apoptosis. Phospholipids (PLs) in particular have received attention in the medical and lipidomics research fields because of their involvement in human diseases such as diabetes, obesity, atherosclerosis, and many cancers associated with lipid metabolic disorders. Here I review experimental strategies for PL analysis based on nanoflow liquid chromatography-electrospray ionization-tandem mass spectrometry (nLC-ESI-MSn). In particular, discussed are lipid extraction methods, nanoflow LC separation of PLs, effect of ionization modifiers on the ESI of PLs, influence of chain lengths and unsaturation degree of acyl chains of PLs on MS intensity, structural determination of the molecular structure of PLs and their oxidized products, and quantitative profiling of PLs from biological samples such as tissue, urine, and plasma in relation to cancer and coronary artery disease.

전기 분무 이온화를 이용한 단백질 질량분석용 마이크로 유체 소자의 제작 및 실험 (Sheathless electrospray ionization with integrated metal emitter on microfluidic device)

  • 김민수;주황수;이국녕;김병기;김용권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.2102-2104
    • /
    • 2004
  • In this study, sheathless electrospray from PDMS/glass microchips with conducting metal emitter tip is described. A chip-based capillary electrophoresis/mass spectrometry (CE/MS) system has advantages of the CE separation and on-line electrospray detection of peptide solution. We have fabricated a new electrospray ionization(ESI) device composed of the metal emitter tip and CE separation channel monolithically in a glass microchip. The separation channel and metal emitter tip are fabricated using a glass wet etching and gold electro plating process, respectively. The fabricated micro electrospray chip was tested by spraying peptide sample for mass spectrometric analysis. Singlely-charged peak and doublely-charged peak of peptide were detected and further MS/MS fragmentation was performed in each peak. Direct comparisons with conventional glass or fused silica emitters showed very similar performance with respect to signal strength and stability.

  • PDF

Determination of nucleosides in human urine by high-performance liquid chromatography with electrospray ionization mass spectrometry(LC/ESI-MS)

  • Lee, Sang-Hee;Jung, Byung-Hwa;Kim, Sun-Yeou;Kim, Ho-Cheol;Chung, Bong-Chul
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2003년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.1
    • /
    • pp.290.1-290.1
    • /
    • 2003
  • Oxidative DNA damage has been associated with many disease. Quantation of DNA adducts is considered to be a useful biomarker of oxidative DNA damage because its formation can also be induced by oxidative stress. Extensive efforts have been taken to identify the analytical methods for minimizing the artifactual formation of oxidative DNA damage. We have done direct analysis of DNA adducts using LC/ESI-MS without urine sample extraction. (omitted)

  • PDF

Examination of Various Metal Ion Sources for Reducing Nonspecific Zinc finger-Zn2+ Complex Formation in ESI Mass Spectrometry

  • Park, Soo-Jin;Park, Sun-Hee;Oh, Joo-Yeon;Han, Sang-Yun;Jo, Kyu-Bong;Oh, Han-Bin
    • Mass Spectrometry Letters
    • /
    • 제3권3호
    • /
    • pp.82-85
    • /
    • 2012
  • The formation of zinc finger peptide-$Zn^{2+}$ complexes in electrospray ionization mass spectrometry (ESI-MS) was examined using three different metal ion sources: $ZnCl_2$, $Zn(CH_3COO)_2$, and $Zn(OOC(CHOH)_2COO)$. For the four zinc finger peptides (Sp1-1, Sp1-3, CF2II-4, and CF2II-6) that bind only a single $Zn^{2+}$ in the native condition, electrospray of apo-zinc finger in solution containing $ZnCl_2$ or $Zn(CH_3COO)_2$ resulted in the formation of zinc finger-$Zn^{2+}$ complexes with multiple zinc ions. This result suggests the formation of nonspecific zinc finger-$Zn^{2+}$ complexes. Zn(tartrate), $Zn(OOC(CHOH)_2COO)$, mainly produced specific zinc finger-$Zn^{2+}$ complexes with a single zinc ion. This study clearly indicates that tartrate is an excellent counter ion in ESI-MS studies of zinc finger-$Zn^{2+}$ complexes, which prevents the formation of nonspecific zinc finger-$Zn^{2+}$ complexes.

Characterization of Basic Nitrogen-Containing Compounds in the Products of Lube Base Oil Processing by Electrospray Ionization Fourier Transform Ion Cyclotron Resonance Mass Spectrometry

  • Li, Xiaohui;Zhu, Jianhua;Wu, Bencheng
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권1호
    • /
    • pp.165-172
    • /
    • 2014
  • The distribution of basic nitrogen-containing compounds in three vacuum gas oils (VGOs) with different boiling ranges and their dewaxed oils from the lube base oil refining unit of a refinery were characterized by positive-ion electrospray ionization (ESI) Fourier transform-ion cyclotron resonance mass spectrometry (FT-ICR MS). It turned out that the composition of basic nitrogen compounds in the samples varied significantly in DBE and carbon number, and the dominant basic N-containing compounds in these oil samples were N1 class species. $N_1O_1$, $N_1O_2$, and $N_2$ class species with much lower relative abundance were also identified. The composition of basic nitrogen compounds in VGOs and dewaxed VGOs were correlated with increased boiling point and varied in DBE and carbon numbers. The comparison of the analytical results between VGOs and dewaxed VGOs indicated that more basic N-containing compounds in VGO with low carbon number and small molecular weight tend to be removed by solvent refining in lube base oil processing.

Discovery to Human Disease Research: Proteo-Metabolomics Analysis

  • Minjoong Joo;Jeong-Hun Mok;Van-An Duong;Jong-Moon Park;Hookeun Lee
    • Mass Spectrometry Letters
    • /
    • 제15권2호
    • /
    • pp.69 -78
    • /
    • 2024
  • The advancement of high-throughput omics technologies and systems biology is essential for understanding complex biological mechanisms and diseases. The integration of proteomics and metabolomics provides comprehensive insights into cellular functions and disease pathology, driven by developments in mass spectrometry (MS) technologies, including electrospray ionization (ESI). These advancements are crucial for interpreting biological systems effectively. However, integrating these technologies poses challenges. Compared to genomic, proteomics and metabolomics have limitations in throughput, and data integration. This review examines developments in MS equipped electrospray ionization (ESI), and their importance in the effective interpretation of biological mechanisms. The review also discusses developments in sample preparation, such as Simultaneous Metabolite, Protein, Lipid Extraction (SIMPLEX), analytical techniques, and data analysis, highlighting the application of these technologies in the study of cancer or Huntington's disease, underscoring the potential for personalized medicine and diagnostic accuracy. Efforts by the Clinical Proteomic Tumor Analysis Consortium (CPTAC) and integrative data analysis methods such as O2PLS and OnPLS extract statistical similarities between metabolomic and proteomic data. System modeling techniques that mathematically explain and predict system responses are also covered. This practical application also shows significant improvements in cancer research, diagnostic accuracy and therapeutic targeting for diseases like pancreatic ductal adenocarcinoma, non-small cell lung cancer, and Huntington's disease. These approaches enable researchers to develop standardized protocols, and interoperable software and databases, expanding multi-omics research application in clinical practice.