• Title/Summary/Keyword: electrospray ionization

Search Result 317, Processing Time 0.028 seconds

Quantitative Analysis of Eleven Bioactive Constituents of a Traditional Herbal Medicine, Yeonggyechulgam-tang using, Liquid Chromatography-Electrospray Ionization Tandem Mass Spectrometry

  • Seo, Chang-Seob;Shin, Hyeun-Kyoo
    • Natural Product Sciences
    • /
    • v.23 no.2
    • /
    • pp.84-91
    • /
    • 2017
  • This study proposes a sensitive and selective liquid chromatography-electrospray ionization tandem mass spectrometry method of efficiently assessing the quality of a traditional herbal medicine called Yeonggyechulgam-tang (YGCGT). The following compounds 1 - 11, namely, liquiritin apioside (1), liquiritin (2), liquiritigene (3), coumarin (4), cinnamic acid (5), cinnamaldehyde (6), glycyrrhizin (7), atractylenolide III (8), atractylenolide II (9), atractylenolide I (10), and pachymic acid (11) were separated on a UPLC BEH $C_{18}$ column ($2.1{\times}100mm$, $1.7{\mu}m$) at a column temperature of $45^{\circ}C$ eluted with a gradient condition of 0.1% (v/v) formic acid in distilled water and acetonitrile. The correlation coefficient of the calibration curve of the eleven constituents was ${\geq}0.9936$. The limits of detection and quantification of the compounds 1 - 11 were 0.06 - 4.73 ng/mL and 0.17-14.20 ng/mL, respectively. Using this analytical method, the compound 11 in lyophilized YGCGT decoction extract was not detected, while the compounds 1 - 10 were detected 0.13-166.43 mg/g.

Effects of Column Length and Particle Diameter on Phospholipid Analysis by Nanoflow Liquid Chromatography-Electrospray Ionization-Mass Spectrometry

  • Lee, Ju-Yong;Lim, Sang-Soo;Moon, Myeong-Hee
    • Mass Spectrometry Letters
    • /
    • v.2 no.3
    • /
    • pp.65-68
    • /
    • 2011
  • The effects of column length and particle size on the efficiency of separation and characterization of phospholipids (PLs) are investigated using nanoflow liquid chromatography-electrospray ionization-tandem mass spectrometry (nLC-ESI-MS-MS). Since PLs are associated with cell proliferation, apoptosis, and signal transduction, it is of increasing interests in lipidomics to establish reliable analytical methods for the qualitative and quantitative profiling of PLs related to biomarker development in adult diseases. Due to the complexity of PLs, the preliminary separation of PLs is necessary prior to MS analysis. In this study, length of capillary column and the particle size of reversed phase ($C_{18}$) packing materials are varied to find a reliable condition for the high speed and high resolution separation using 8 PL standard mixtures. From experiments, it was found that a capillary column of nLC-ESI-MS-MS analysis for PL mixtures can be minimized to a 5 cm long pulled tip column packed with 3 ${\mu}m$ $C_{18}$ particles without losing resolution.

Electronic Photodepletion Spectroscopy of Dibenzo-18-crown-6 with a Potassium Ion

  • Kim, Hwan-Jin;Shin, Won-Jik;Choi, Chang-Min;Lee, Jun-Ho;Kim, Nam-Joon
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.10
    • /
    • pp.1973-1976
    • /
    • 2008
  • Electronic photodepletion spectrum of dibenzo-18-crown-6 with a potassium ion ($K^+$-DB18C6) was obtained in the gas phase using electrospray ionization and quadrupole ion-trap reflectron time-of-flight mass spectrometry. The spectrum exhibited rather a broad absorption band at 36350 $cm^{-1}$, which was tentatively assigned as the origin of the S1 band. The photodepletion spectrum of $Cs^+$-DB18C6 was also obtained to elaborate the effects of metal cations on electronic and geometric structures of metal cation-DB18C6 complexes. We found that the S1 band of $Cs^+$-DB18C6 was red-shifted by 180 $cm^{-1}$ from that of $K^+$-DB18C6. With the results of quantum theoretical calculations using the density functional theory, we suggested that the red-shift arose mainly from weaker binding of $Cs^+$ to DB18C6 than that of K+, which resulted from a larger size of $Cs^+$ than that of the cavity in DB18C6.

Mass Spectrometric Analysis of Eight Common Chemical Explosives Using Ion Trap Mass Spectrometer

  • Park, Sehwan;Lee, Jihyeon;Cho, Soo Gyeong;Goh, Eun Mee;Lee, Sungman;Koh, Sung-Suk;Kim, Jeongkwon
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.12
    • /
    • pp.3659-3664
    • /
    • 2013
  • Eight representative explosives (ammonium perchlorate (AP), ammonium nitrate (AN), trinitrotoluene (TNT), 2,4-dinitrotoluene (DNT), cyclonite (RDX), cyclotetramethylenetetranitramine (HMX), pentaerythritol tetranitrate (PETN), and hexanitrostilbene (HNS)) were comprehensively analyzed with an ion trap mass spectrometer in negative ion mode using direct infusion electrospray ionization. MS/MS experiments were performed to generate fragment ions from the major parent ion of each explosive. Explosives in salt forms such as AP or AN provided cluster parent ions with their own anions. Explosives with an aromatic ring were observed as either $[M-H]^-$ for TNT and DNT or $[M]^{{\cdot}-}$ for HNS, while explosives without an aromatic ring such as RDX, HMX, and PETN were detected as an adduct ion with a formate anion, i.e., $[M+HCOO]^-$. These findings provide a guideline for the rapid and accurate detection of explosives once portable MS instruments become more readily available.

Quantitative Analysis of Twelve Marker Compounds in Palmijihwang-hwan using Ultra-Performance Liquid Chromatography Coupled with Electrospray Ionization Tandem Mass Spectrometry

  • Seo, Chang-Seob;Shin, Hyeun-Kyoo
    • Natural Product Sciences
    • /
    • v.20 no.3
    • /
    • pp.182-190
    • /
    • 2014
  • An ultra-performance liquid chromatography (UPLC) coupled with electrospray ionization (ESI) tandem mass spectrometry (MS) method was established for quantitative analysis of twelve components, allantoin (1), morroniside (2), 5-hydroxymethyl-2-furfural (5-HMF) (3), loganin (4), coumarin (5), cinnamic acid (6), mesaconitine (7), cinnamaldehyde (8), hypaconitine (9), aconitine (10), alisol B (11), and alisol B acetate (12) in a Palmijihwang-hwan decoction. The twelve constituents were separated on a UPLC BEH C18 column ($2.1{\times}100mm$, $1.7{\mu}m$) at a column temperature of $40^{\circ}C$ by gradient elution with 0.1% (v/v) formic acid in water and acetonitrile as the mobile phase. The flow rate was 0.3 mL/min and the injection volume was $2.0{\mu}L$. Calibration curves of all compounds were acquired with values of the correlation coefficient ${\geq}0.99$ within the test ranges. The limits of detection and quantification for all analytes were 0.01 - 4.53 ng/mL and 0.03 - 13.60 ng/mL, respectively. The concentrations of the compounds 1 - 9 and 12 were 72.83, 4389.00, 4859.00, 3155.17, 223.67, 33.50, 1.97, 518.00, 2.25, and $25.00{\mu}g/g$, respectively. However, compounds 10 and 11 were not detected.

Characterization of Triterpenoids, Flavonoids and Phenolic Acids in Eclipta prostrata by High-performance Liquid Chromatography/diode-array Detector/electrospray Ionization with Multi-stage Tandem Mass Spectroscopy

  • Lee, Ki-Yong;Ha, Na-Ry;Kim, Tae-Bum;Kim, Young-Choong;Sung, Sang-Hyun
    • Natural Product Sciences
    • /
    • v.16 no.3
    • /
    • pp.164-168
    • /
    • 2010
  • High-performance liquid chromatographic method with diode-array detector and electrospray ionization with multi-stage tandem mass spectroscopy (HPLC/DAD/ESI-$MS^n$) was used to identify the major constituents in a methanolic extract of Eclipta prostrata. The chromatographic separation was performed on a C18 column. Acetonitrile-water was used as a mobile phase. HPLC/DAD/ESI-$MS^n$ allowed the characterization of constituents of E. prostrata, mainly triterpenoids (eclalbasaponin I, II, III, IV, VI), flavonoids (luteolin 7-O-glucoside, demethylwedelolactone, wedelolactone, luteolin, demetylwedelolactone sulfate, luteolin sulfate, apigenin sulfate) and phenolic acids (5-O-caffeoylquinic acid, 3, 4-O-dicaffeoylquinic acid, 3, 5-O-dicaffeoylquinic acid, 4, 5-Odicaffeoylquinic acid).

Quantitative Analysis of Hyangsayukgunja-Tang Using an Ultra-Performance Liquid Chromatography Coupled to Electrospray Ionization Tandem Mass Spectrometry (LC-MS/MS를 이용한 향사육군자탕의 주요성분의 함량분석)

  • Seo, Chang-Seob;Shin, Hyeun-Kyoo
    • Korean Journal of Pharmacognosy
    • /
    • v.46 no.4
    • /
    • pp.352-364
    • /
    • 2015
  • The aim of this study was to quantitatively analyze for quality assessment of eighteen marker compounds, including homogentisic acid, 3,4-dihydroxybenzaldehyde, spinosin, liquiritin, hesperidin, ginsenoside Rg1, liquiritigenin, ginsenoside Rb1, glycyrrhizin, 6-gingerol, atractylenolide III, honokiol, costunolide, dehydrocostuslactone, atractylenolide II, nootkatone, magnolol, and atractylenolide I, in Hyangsayukgunja-tang using an ultra-performance liquid chromatography-electrospray ionization-mass spectrometer. The column for separation of eighteen marker components were used a UPLC BEH $C_{18}$ analytical column ($2.1{\times}100mm$, $1.7{\mu}$) and kept at $45^{\circ}C$ by gradient elution with 0.1% (v/v) formic acid in water and acetonitrile as mobile phase. The flow rate and injection volume were 0.3 mL/min and $2.0{\mu}l$, respectively. The correlation coefficient of all marker compounds was ${\geq}0.9914$, which means good linearity, within the test ranges. The limits of detection and quantification values of the all analytes were in the ranges 0.04-1.11 and 0.13-3.33 ng/mL, respectively. As a result, five compounds, homogentisic acid, 3,4-dihydroxybenzaldehyde, spinosin, liquiritigenin, and atractylenolide I, in this sample were not detected and the amounts of the 13 compounds except for the 5 compounds were $8.10-6736.37{\mu}g/g$ in Hyangsayukgunja-tang extract.

Characterization of Basic Nitrogen-Containing Compounds in the Products of Lube Base Oil Processing by Electrospray Ionization Fourier Transform Ion Cyclotron Resonance Mass Spectrometry

  • Li, Xiaohui;Zhu, Jianhua;Wu, Bencheng
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.1
    • /
    • pp.165-172
    • /
    • 2014
  • The distribution of basic nitrogen-containing compounds in three vacuum gas oils (VGOs) with different boiling ranges and their dewaxed oils from the lube base oil refining unit of a refinery were characterized by positive-ion electrospray ionization (ESI) Fourier transform-ion cyclotron resonance mass spectrometry (FT-ICR MS). It turned out that the composition of basic nitrogen compounds in the samples varied significantly in DBE and carbon number, and the dominant basic N-containing compounds in these oil samples were N1 class species. $N_1O_1$, $N_1O_2$, and $N_2$ class species with much lower relative abundance were also identified. The composition of basic nitrogen compounds in VGOs and dewaxed VGOs were correlated with increased boiling point and varied in DBE and carbon numbers. The comparison of the analytical results between VGOs and dewaxed VGOs indicated that more basic N-containing compounds in VGO with low carbon number and small molecular weight tend to be removed by solvent refining in lube base oil processing.

Carbohydrate Drug (Acarbose) Analysis using by the On-line HPLC/Electrospray Ionization-Mass Spectrometry (On-line HPLC/ESI-MS를 이용한 탄수화물제제 (Acarbose) 분석연구)

  • Cho, Hyun-Woo;Myung, Seung-Woon
    • Analytical Science and Technology
    • /
    • v.15 no.6
    • /
    • pp.574-579
    • /
    • 2002
  • A sensitive and easy high performance liquid chromatograph (HPLC) / electrospray ionization (ESI)-mass spectrometric (MS) method has been developed for the quantitative and qualitative analyses of acarbose and its metabolites. After plasma samples were simply filtered with a syringe filter, the filtered plasma was analyzed by LC/MS. The standard calibration curve for acarbose was linear ($r^2=0.9963$) over the concentration range $0.1{\sim}10{\mu}g/m{\ell}$ in plasma. The metabolite component-I and II, which were metabolized by the ${\alpha}$-amylase and ${\beta}$-amylase, were found also by in vitro incubation. The developed method can be utilized to study acarbose and the other carbohydrates.

Quantitative Analysis of the Seventeen Marker Components in Dangguisu-san Using Ultra-performance Liquid Chromatography Coupled to Electrospray Ionization Tandem Mass Spectrometry (LC-MS/MS를 이용한 당귀수산 추출물 중 17종 성분의 함량분석)

  • Seo, Chang-Seob;Shin, Hyeun-Kyoo
    • YAKHAK HOEJI
    • /
    • v.58 no.3
    • /
    • pp.158-164
    • /
    • 2014
  • Dangguisu-san is a well-known traditional Korean herbal medicine prescription and has been widely used to treat ecchymosis, blood stagnation, and pain resulting from physical shock in Korea. In this study, an ultra-performance liquid chromatography-electrospray ionization-mass spectrometer method was established for the simultaneous determination of the 17 biomarker components in Dangguisu-san. All analytes were separated on an UPLC BEH $C_{18}$ ($100{\times}2.1$ mm, $1.7{\mu}m$) column and maintained at $45^{\circ}C$. The mobile phase consisted of two solvent systems, 0.1% (v/v) formic acid in water (A) and acetonitrile (B) by gradient flow. The injection volume was $2.0{\mu}l$ and the flow rate was 0.3 ml/min with detection at mass spectrometer. Calibration curves of the 17 biomarker components were acquired with $r^2$ values ${\geq}0.9951$. The values of limit of detection and quantification of all analytes were 0.02~6.32 ng/ml and 0.05~18.95 ng/ml, respectively. The amounts of the 17 components in Dangguisu-san sample were $3.17{\sim}13,224.50{\mu}g/g$.