• 제목/요약/키워드: electrospray

검색결과 440건 처리시간 0.021초

A Comprehensive Identification of Synaptic Vesicle Proteins in Rat Brains by cRPLC/MS-MS and 2DE/MALDI-TOF-MS

  • Lee, Won-Kyu;Kim, Hye-Jung;Min, Hye-Ki;Kang, Un-Beom;Lee, Cheol-Ju;Lee, Sang-Won;Kim, Ick-Young;Lee, Seung-Taek;Kwon, Oh-Seung;Yu, Yeon-Gyu
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권9호
    • /
    • pp.1499-1509
    • /
    • 2007
  • Proteomic analyses of synaptic vesicle fraction from rat brain have been performed for the better understanding of vesicle regulation and signal transmission. Two different approaches were applied to identify proteins in synaptic vesicle fraction. First, the isolated synaptic vesicle proteins were treated with trypsin, and the resulting peptides were analyzed using a high-pressure capillary reversed phase liquid chromatography/tandem mass spectrometry (cRPLC/MS/MS). Alternatively, proteins were separated by two-dimensional gel electrophoresis (2DE) and identified by matrix-assisted laser desorption ionization mass spectrometry (MALDI-TOF/MS). Total 18 and 52 proteins were identified from cRPLC/MS-MS and 2DE-MALDI-TOF-MS analysis, respectively. Among them only 2 proteins were identified by both methods. Of the proteins identified, 70% were soluble proteins and 30% were membrane proteins. They were categorized by their functions in vesicle trafficking and biogenesis, energy metabolism, signal transduction, transport and unknown functions. Among them, 27 proteins were not previously reported as synaptic proteins. The cellular functions of unknown proteins were estimated from the analysis of domain structure, expression profile and predicted interaction partners.

Structural Analysis of Cu Binding Site in [Cu(I)·d(CpG)·d(CpG)-2H]-1 Complex

  • Im, Yu-Jin;Jung, Sang-Mi;Kang, Ye-Song;Kim, Ho-Tae
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권4호
    • /
    • pp.1232-1236
    • /
    • 2013
  • The Cu cation binding sites of $[Cu(I){\cdot}d(CpG){\cdot}d(CpG)-2H]^{-1}$ complex have been investigated to explain the $[Cu{\cdot}DNA]$ biological activity caused by the Cu association to DNA. The structure of $[Cu(I){\cdot}d(CpG){\cdot}d(CpG)-2H]^{-1}$ complex was investigated by electrospray ionization mass spectrometry (ESI-MS). The fragmentation patterns of $[Cu(I){\cdot}d(CpG){\cdot}d(CpG)-2H]^{-1}$ complex were analyzed by MS/MS spectra. In the MS/MS spectra of $[Cu(I){\cdot}d(CpG){\cdot}d(CpG)-2H]^{-1}$ complex, three fragment ions were observed with the loss of d(CpG), {d(CpG) + Cyt}, and {d(CpG) + Cyt + dR}. The Cu cation binds to d(CpG) mainly by substituting the $H^+$ of phosphate group. Simultaneously, the Cu cation prefers to bind to a guanine base rather than a cytosine base. Five possible geometries were considered in the attempt to optimize the $[Cu(I){\cdot}d(CpG){\cdot}d(CpG)-2H]^{-1}$ complex structure. The ab initio calculations were performed at B3LYP/6-31G(d) level.

Identification of Glutathione Conjugates of 2, 3-Dibromopropene in Male ICR Mice

  • Lee Sang Kyu;Baik Seo Yeon;Jeon Tae Won;Jun In Hye;Kim Ghee Hwan;Jin Chun Hua;Lee Dong Ju;Kim Jun Kyou;Yum Young Na;Jeong Tae Cheon
    • Archives of Pharmacal Research
    • /
    • 제29권2호
    • /
    • pp.172-177
    • /
    • 2006
  • Hepatotoxic potential of 2, 3-dibromopropene (2, 3-DBPE) and its conjugation with glutathione (GSH) were investigated in male ICR mice. Treatment of mice with 20, 50, and 100 mg/kg of 2, 3-DBPE for 24 h caused elevation of serum alanine aminotransferase and aspartate aminotransferase activities. The hepatic content of GSH was not changed by 2, 3-DBPE. Meanwhile, the GSH content was slightly reduced when mice were treated with 2, 3-DBPE for 6 h and significantly increased 12 h after the treatment. Subsequently, a possible formation of GSH conjugate of 2, 3-DBPE was investigated in vivo. After the animals were treated orally with 20, 50, and 100 mg/kg of 2, 3-DBPE, the animals were subjected to necropsy 6, 12, and 24 h later. A conjugate of S-2-bromopropenyl GSH was identified in liver and serum treated with 100 mg/kg of 2, 3-DBPE by using liquid chromatography-electrospray ionization tandem mass spectrometry. The protonated molecular ions $[M+H]^+$ of S-2-bromopropenyl GSH were observed at m/z 425.9 and 428.1 in the positive ESI spectrum with a retention time of 6.35 and 6.39 min, respectively. In a time-course study in livers following an oral treatment of mice with 100 mg/kg of 2, 3-DBPE for 6, 12, and 24 h, the 2, 3-DBPE GSH conjugate was detected maximally 6 h after the treatment. The present results suggested that 2, 3-DBPE-induced hepatotoxicity might be related with the production of its GSH conjugate.

Quantitative Analysis of Lysophosphatidic Acid in Human Plasma by Tandem Mass Spectrometry

  • Kim, Ho-Hyun;Yoon, Hye-Ran;Pyo, Dong-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권8호
    • /
    • pp.1139-1143
    • /
    • 2002
  • Analysis of lysophosphatidic acids (LPAs) is of clinical importance as they can serve a potential marker for ovarian and other gynecological cancers and obesity. It is critically important to develop a highly sensitive and specific method for the early detection of gynecological cancers to improve the overall outcome of this disease. We have established a novel quantification method of LPAs in human plasma by negative ionization tandem mass spectrometry (MS-MS) using multiple reaction monitoring (MRM) mode without the conventional TLC step. Protein-bound lipids, LPAs in plasma were extracted with methanol : chloroform (2:1) containing LPA C14:0 as an internal standard under acidic condition. Following back extraction with chloroform and water, the centrifuged lower phase was evaporated and reconstituted in methanol. The reconstituted solution was directly injected into electrospray source of MS/MS. For MRM mode, Q1 ions selected were m/z 409, 433, 435, 437 and 457 which corresponds to molecular mass [M-H]- of C16:0, C18:2, C18:1, C18:0 and C20:4 LPA, respectively. Q2 ions selected for MRM were m/z 79, phosphoryl product. Using MS/MS with MRM mode, all the species of LPAs were completely separated from plasma matrix without severe interferences. This method allowed simultaneous detection and quantification of different species of LPAs in a plasma over a linear dynamic range of 0.01-25 ㎛olL-1 . The detection limit of the method was 0.3 pmol/mL, with a correlation coefficient of 0.9983 in most LPAs analyzed. When applied to the plasmas of normal and gynecological cancer patients, this new method differentiated two different groups by way of total LPA level.

High Speed Separation of PFCs in Human Serum by C18-Monolithic Column Liquid Chromatography-Tandem Mass Spectrometry

  • Lee, Won-Woong;Lee, Sun-Young;Yu, Se Mi;Hong, Jongki
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권11호
    • /
    • pp.3727-3734
    • /
    • 2012
  • An analytical method has been developed for the rapid determination of perfluorinated compounds (PFCs) in human serum samples. The extraction and purification of PFCs from human serum were performed by the modified method of previous report. Ten PFCs were rapidly separated within 3.3 min by C18-monolithic column liquid chromatography (LC) and detected by electrospray ionization (ESI) tandem mass spectrometry (MS/MS) in negative ion mode. The runtime of PFCs on monolithic column LC was up to 4-fold faster than that on conventional column LC. The effect of triethylamine (TEA) to the mobile phase has investigated on the overall MS detection sensitivity of PFCs in ESI ionization. Quantification was performed by LC-MS/MS in multiple-ion reaction monitoring (MRM) mode, using $^{13}C$-labeled internal standards. Method validation was performed to determine recovery, linearity, precision, and limits of quantification, followed by, the analysis of a standard reference material (SRM 1957 from NIST). The overall recoveries ranged between 81.5 and 106.3% with RSDs of 3.4 to 16.2% for the entire procedure. The calibration range extended from 0.33 to 50 $ng\;mL^{-1}$, with a correlation coefficient ($R^2$) greater than 0.995 and the limits of quantification with 0.08 to 0.46 $ng\;mL^{-1}$. This approach can be used for rapid and sensitive quantitative analysis of 10 PFCs in human serum with high performance and accuracy.

Proteomic Analysis of Rat PC12 Cells Exposed to Cyclosporin A

  • Jung, Ji-Yeon;Seol, Kwang;Jeong, Yeon-Jin;Kim, Won-Jae;Oh, Sang-Jin
    • International Journal of Oral Biology
    • /
    • 제34권1호
    • /
    • pp.29-36
    • /
    • 2009
  • Cyclosporin A (CsA) has been used clinically as an immunosuppressive drug to prevent organ transplant rejection and in basic research as a mitochondrial permeability blocker. It has been reported that CsA has a protective role in severed neurons and a neurotrophic effect in neuronal cells. However, the molecular mechanisms underlying the stimulation of neuronal cell proliferation by CsA have not yet been elucidated. In our current study, we investigated CsA responsive proteins in PC12 cells using a systematic proteomic approach. The viability of these cells following CsA treatment increased in a dose- and time-dependent manner. Proteins in the CsA-treated PC12 cells were profiled by two-dimensional gel electrophoresis (2-DE) and identified by matrix-assisted laser desorption ionization time-of flight (MALDI-TOF) and electrospray ionization quadupole time-of-flight mass spectrometries (EIQ-TOFMS). This differential expression analysis showed significant changes for 10 proteins (6 up-regulated and 4 down-regulated) upon CsA treatment that were related to cell proliferation, metabolism and the stress response. These proteomics data further our understanding of the proliferation mechanisms of PC12 cells exposed to CsA and demonstrate that our methodology has potential to further elucidate the mechanisms and pathways involved.

HPLC-DAD-MS/MS를 이용한 금은화 생리활성 물질의 동시분석 (Simultaneous Analysis of Bioactive Metabolites from Lonicera japonica Flower Buds by HPLC-DAD-MS/MS)

  • 유성광;전주은;강경원;강삼식;신종헌
    • 약학회지
    • /
    • 제52권6호
    • /
    • pp.446-451
    • /
    • 2008
  • A high-performance liquid chromatography (HPLC) with diode array detector (DAD) and electrospray ionization mass spectrometry (ESI-MS) was established for the simultaneous determination of chlorogenic acid (1), sweroside (2), luteolin-7-O-glucoside (3), (E)-aldosecologanin (4) and 3,5-dicaffeoylquinic acid (5) from Lonicera joponica flower buds. The optimal chromatographic conditions were obtained on an ODS column (5 ${\mu}m$, 4.6${\times}$150 mm) with the column temperature $25^{\circ}C$. The mobile phase was composed of (A) water with 0.1% formic acid and (B) acetonitrile with 0.1% formic acid using a gradient elution, the flow rate was 0.3 ml/min. Detection wavelength was set at 250 nm. All calibration curves showed good linear regression ($r^2$>0.994) within test ranges. The developed method provided satisfactory precision and accuracy with overall intra-day and inter-day variations of 0.05${\sim}$1.95% and 0.15${\sim}$2.26%, respectively, and the overall recoveries of 97.71${\sim}$103.65% for the five compounds analyzed. The verified method was successfully applied to quantitative determination of the three types (phenolic compounds, iridoids and flavonoids) of bioactive compounds in 21 commercial L. japonica flower buds samples from different markets in Korea and China. The analytical results demonstrated that the contents of the five analytes vary significantly with sources.

LC/ESI-MS/MS를 이용한 식육(소, 돼지)중 잔류 phoxim 분석 (Analysis of Phoxim Residue in Animal Food Production (Cattle and Pig) by LC/ESI-MS/MS)

  • 박미선;이진주;명승운
    • 대한화학회지
    • /
    • 제55권4호
    • /
    • pp.626-632
    • /
    • 2011
  • 폭심(phoxim)은 널리 사용되고 있는 구충제인 동물용의약품이다. 본 논문에서는 소와 돼지 근육에 잔류하는 폭심을 분석하기 위해서, 실리카 고체상과 아세토니트릴을 사용하여 추출/정제하였다. 분석을 위해서 LC/ESI-MS/MS 방법이 사용되었다. HPLC에서 $C_{18}$ 컬럼($2.1{\times}100\;mm$, $3.5\;{\mu}m$)이 사용되었으며, 이동상으로는 0.1% formic acid와 물이 사용되었다. 소(0.0048~2.0 mg/kg)와 돼지(0.0055~2.0 mg/kg)에 소량첨가하여 얻은 검정곡선은 좋은 직선성($r^2$=0.995)을 나타내었다. 소와 돼지의 매트릭스에 대해서 0.0048~0.2 mg/kg범위에서 68.2~106.9%의 정확도를 나타내었으며, LOD는 0.0014~0.0017 mg/kg, LOQ는 0.0048~0.0055 mg/kg범위에 있었으며, 11.2%의 상대표준편차를 나타내었다.

Rapid Determination of Imatinib in Human Plasma by Liquid Chromatography-Tandem Mass Spectrometry: Application to a Pharmacokinetic Study

  • Yang, Jeong Soo;Cho, Eun Gi;Huh, Wooseong;Ko, Jae-Wook;Jung, Jin Ah;Lee, Soo-Youn
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권8호
    • /
    • pp.2425-2430
    • /
    • 2013
  • A simple, fast and robust analytical method was developed to determine imatinib in human plasma using liquid chromatography-tandem mass spectrometry with electrospray ionization in the positive ion mode. Imatinib and labeled internal standard were extracted from plasma with a simple protein precipitation. The chromatographic separation was performed using an isocratic elution of mobile phase involving 5.0 mM ammonium formate in water-5.0 mM ammonium formate in methanol (30:70, v/v) over 3.0 min on reversed-stationary phase. The detection was performed using a triple-quadrupole tandem mass spectrometer in multiple-reaction monitoring mode. The developed method was validated with lower limit of quantification of 10 ng/mL. The calibration curve was linear over 10-2000 ng/mL ($R^2$ > 0.99). The method validation parameters met the acceptance criteria. The spiked samples and standard solutions were stable under conditions for storage and handling. The reliable method was successfully applied to real sample analyses and thus a pharmacokinetic study in 27 healthy Korean male volunteers.

In situ 광전자분광/역광전자분광 분석을 이용한 유기물 계면의 전자구조 연구 (In situ photoemission and inverse photoemission studies on the interfacial electronic structures of organic materials)

  • 이연진
    • 진공이야기
    • /
    • 제2권2호
    • /
    • pp.4-11
    • /
    • 2015
  • 본 글에서는 광전자 분광 및 역광전자 분광을 이용한 유기분자 시스템의 전자구조 연구에 대하여 기술하였다. 다양한 유기물간의 계면 연구가 급속도로 늘어나고 있으며, 폴리머, 거대 분자 등 기존의 in situ 분석 방법으로 실험이 어려운 물질까지도 연구의 필요성이 늘어나고 있다. Electrospray 증착 방법이 이러한 새로운 물질들의 계면 전자구조 연구를 가능하게 할 수 있음을 살펴보았으며, 다양한 새로운 분석 기법들의 출현을 기대해 본다. 몇 가지 예에서 살펴본 바와 같이 전자구조는 소자 구동 특성을 직접적으로 지배하는 핵심적인 물리량이며, 전자구조의 이해를 통해 전자소자의 구동 원리, 성능 최적화 및 소자 특성 열화의 원인을 파악할 수 있다. 현재, 유기물 소자 관련 기술의 성숙도는 전자구조 분석과 같은 기초 연구 결과 없이는 더 이상 발전할 수 없는 정도에 이르러, 관련 분석 기술에 대한 수요가 더욱 늘어날 것으로 전망된다.