• Title/Summary/Keyword: electronic skin

Search Result 250, Processing Time 0.026 seconds

Impedance of CoZrNb Film as a Function of Frequency (CoZrNb막의 주파수에 따른 임피던스의 변화)

  • Hur, J.;Kim, Y.H.;Shin, K.H.;Park, K.I.;SaGong, G.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.778-781
    • /
    • 2002
  • MI(Magneto-Impedance) sensor which is made by thin films has significantly high detecting sensitivity in weak magnetic field. It also has a merit to be able to build in the low power system. Its structure is simple, which makes it easier to prepare a miniature. In this study, its magnetic permeability and anisotropy field$(H_k)$ as a function of a thickness of sputtered amorphous CoZrNb films with zero-magnetostriction and excellent soft magnetic property are investigated. In order to make a uniaxial anisotropy, film was subjected to the post annealing in a static magnetic field with 1KOe intensity at 250, 300, and $320^{\circ}C}$ respectively for 2 hours. Anisotropy field$(H_k)$ of film is measured by using a MH loop tracer. Its magnetic permeability of a film is measured over the frequency range from 1 MHz to 750MHz. It has shown that the magnetic permeability of amorphous CoZrNb film is decreased due to the skin effect with increasing a thickness of the CoZrNb film, and hence its driving frequency is lowered. And, it was examined on the permeability and impedance to fabricate the MI sensor which acts at a low frequency by thickening a CoZrNb film relatively.

  • PDF

Ear Detection using Haar-like Feature and Template (Haar-like 특징과 템플릿을 이용한 귀 검출)

  • Hahn, Sang-Il;Cha, Hyung-Tai
    • Journal of Broadcast Engineering
    • /
    • v.13 no.6
    • /
    • pp.875-882
    • /
    • 2008
  • Ear detection in an image processing is the one of the important area in biometrics. In this paper we propose a human ear detection algorithm with side face images. First, we search a face candidate area in an input image by using skin-color model and try to find an ear area based on Haar-like feature. Then, to verity whether it is the ear area or not, we use the template which is excellent object classification compare to recognize the characters in the plate. In this experiment, the proposed method showed that the processing speed is improved by 60% than previous works and the detection success rate is 92%.

A Study on the Immunohistology in Injury Cure of Rat by using InGaAlP Laser Diode (InGaAlP 레이저다이오드를 적용한 Rat의 착상 치유에서 면역조직화학적 연구)

  • Yu, Seong-Mi;Park, Yong-Pil;Cheon, Min-Woo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.5
    • /
    • pp.431-435
    • /
    • 2009
  • The apparatus has been fabricated using the laser diode and microprocessor unit. The apparatus used a InGaAlP laser diode for laser medical therapy and was designed for a pulse width modulation type to increase stimulation effects. To raise the stimulus effect of the human body, the optical irradiation frequency could be set up. The study has executed in-vivo experiment by employing our own developed laser diode irradiation system to investigate the effects of the InGaAlP laser diode irradiation on the wound healing as a preliminary study aimed at the application of InGaAlP laser diode to wound healing of human skin injury. The study cut out whole skin layers of Sprague-Dawley rat on the back part in 1 cm circle and observed developing effects after executing light irradiation for 9 days, and in result it is found that the light irradiation rat showed earlier wound healing than non-irradiation rat during the experimental period. In addition, there are some differences found regarding the healing process between laser diode irradiated rats and non-irradiated ones.

Development of Global Simulator of $O_2$ Discharge in High Density Transformer Coupled Plasma Source (고밀도 유도결합 플라즈마 장치의 $O_2$ 방전에 대한 공간 평균 시뮬레이터 제작)

  • Kim, Hyung-Yong;Yoon, Nam-Sik;Kwon, Deuk-Chul;Kim, Jeong-Hyung;Jeong, Kwang-Hwa;Sin, Yong-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.550-551
    • /
    • 2005
  • 고밀도 유도결합 플라즈마 장치의 $O_2$ 방전에 대한 공간 평균 시뮬레이터를 제작하였다. 제작된 시뮬레이터는 $O_2$ 플라즈마 방전에서 발생되는 전자, 양이온, 음이온 및 중성종, 활성종들에 대해 공간 평균된 유체 방정식을 기반으로 하고 있으며, 고밀도 유도결합 플라즈마 장치에서 전자가열 모델은 anomalous skin effect 를 고려한 파워 흡수 모델을 적용하여 전자가 흡수하는 고주파 파워량을 결정하였다. 완성된 시뮬레이터에서 RF- 파워, gas-inlet, pumping-speed등의 조정 변수를 비롯한 여러 가지 장치 변수들의 변화에 대한 하전입자, 중성종, 활성종들의 밀도 변화 및 전자 온도 의존성을 계산하였다.

  • PDF

Fabrication and Electrical Evaluation of Al/Cu Composite Conductor (Al/Cu 복합도체 제조 및 전기적 특성 평가)

  • Sim, Ki-Deok;Cho, Jeon-Wook;Bae, Jun-Han;Jung, Won-Mo;Sin, Deok-Su
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.621-622
    • /
    • 2005
  • Copper is widely used in electric wire, cable, conductor in electric devices. As the demand for electric power is increasing rapidly, electric power devices are getting amazingly bigger and complicated. The using of light-weight conductor can reduce the size and making cost of the electric devices. In high-frequency application, Electric current the current in a conductor tends to shift to the surface of the conductor, resulting in an uneven current distribution in the inner conductor. In the extreme case the current may essentially concentrate in the "skin" of the inner conductor as a surface current. In high frequency application, therefore, inner area of copper conductor may replace with aluminum conductor, which reduces the weight of conductor. This paper describes the manufacture and evaluation of composite conductors made of copper and aluminum.

  • PDF

Development of 6-Axis Stiffness Measurement Device for Prosthetic Socket Design (의수 소켓 설계를 위한 6축 인체 탄성도 측정 장치 개발)

  • Oh, Donghoon;Lee, Seulah;Choi, Youngjin
    • The Journal of Korea Robotics Society
    • /
    • v.14 no.1
    • /
    • pp.58-64
    • /
    • 2019
  • The paper proposes a stiffness measurement device composed of a measurement part including six indenters and a fixing part including four fixtures. The device is able to make simultaneously measurements of the stiffness of human arm. The six indenters make use of both position and force control schemes sequentially whenever needed. In addition, the loadcells and the digital encoders are attached to the indenters and electric motors, respectively, so that the data can be provided in real time. On the end of the indenter, two-axis potentiometer is attached in order to measure the angle difference between the applied force axis and the axis normal to the skin of human arm, and to convert the force measured on the loadcell into the actual applied force to skin. For this purpose, the mapping between the voltage output and the angle of potentiometer was obtained by fitting it for each axis. Ultimately, the measurement device was able to measure the stiffnesses of six regions of human arm.

Highly Sensitive Stretchable Electronic Skin with Isotropic Wrinkled Conductive Network

  • Seung Hwan Jeon;Hyeongho Min;Jihun Son;Tae Kon Ahn;Changhyun Pang
    • Journal of Sensor Science and Technology
    • /
    • v.33 no.1
    • /
    • pp.7-11
    • /
    • 2024
  • Soft-pressure sensors have numerous applications in soft robotics, biomedical devices, and wearable smart devices. Herein, we present a highly sensitive electronic skin device with an isotropic wrinkled pressure sensor. A conductive ink for soft pressure sensors is produced by a solution process using polydimethylsiloxane (PDMS), poly 3-hexylthiophene (P3HT), carbon black, and chloroform as the solvents. P3HT provides high reproducibility and conductivity by improving the ink dispersibility. The conductivity of the ink is optimized by adjusting the composition of the carbon black and PDMS. Soft lithography is used to fabricate a conductive elastic structure with an isotropic wrinkled structure. Two conductive elastic structures with an isotropic wrinkle structure is stacked to develop a pressure sensor, and it is confirmed that the isotropic wrinkle structure is more sensitive to pressure than when two elastic structures with an anisotropic wrinkle structure are overlapped. Specifically, the pressure sensor fabricated with an isotropic wrinkled structure can detect extremely low pressures (1.25 Pa). Additionally, the sensor has a high sensitivity of 15.547 kpa-1 from 1.25 to 2500 Pa and a linear sensitivity of 5.15 kPa-1 from 2500 Pa to 25 kPa.

Preference survey on the development of a bath preparation used by Zizania latifolia (고장초(Zizania latifolia)를 이용한 입욕제 개발제품의 선호도 조사)

  • Oh, Pyung-Il;Hong, Seung-Hui;Lee, Han-Chun;Moon, Kyung-Rye;Lee, Mi-Ja
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.7
    • /
    • pp.1111-1120
    • /
    • 2013
  • Zizania latifola has used for folk medicine in Korea. It is effective in treating skin trouble and sensitivity skins. The purpose of this study was to develop high valuable types of bath preparation of Zizania latifolia. The natural materials were manufactured by the mixed ratio of Zizania latifolia. Product was manufactured by the mixed ratio of Zizania latifolia and 3 natural materials. Green tea was highest in sensory evaluation as similar with Zizania latifolia. optimum condition of mixed ratio was adaptive 50% Houttuynia cordata, 30% green tea with 20% Artemisia vularis. Product's sensory evaluation was showed best in mixing 40% and Zizania latifolia extract 60%. There were optimal condition for manufacturing of cleansing. Therefore, The development of a bath preparation used by Zizania latifolia is very useful for manufacturing cleansing. We suggest that it help for improve skin trouble and make healthy skin.

Analysis of Electromagnetic Wave Characteristics of Microwave Nondestructive Device for Inspecting Human Lower Leg (마이크로파 비파괴 검사를 위한 인체 하지에 대한 전자파특성 분석)

  • Kim, Byung-Mun;Lee, Sang-Min;Park, Young-Ja;Hong, Jae-Pyo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.2
    • /
    • pp.385-394
    • /
    • 2021
  • In this paper, a new equation of electromagnetic wave transmission matrix was proposed to calculate the reflected power and transmitted power for the multi-layered planar lossy structure. The applied human leg was modeled as a four-layer planar structure of skin, fat, muscle and bone. The complex dielectric constant to consider the loss of each of these layers was calculated using the 4-pole cole-cole model parameter. When electromagnetic waves were incident on the skin surface, total reflected and transmitted power, and human body loss were calculated for a frequency band of 0.1 to 20.0 GHz. And for various muscle thicknesses, the power reflected only from the outermost bone and re-radiated from the skin was calculated. It was confirmed that at the muscle thickness of 3.0 mm and the frequency of 4.6 GHz the return loss was -6.13 dB, which was 3.42 dB lower than the average value.

Electrode Characteristics of Non-contact Electrocardiographic Measurement

  • Mathias, Dakurah Naangmenkpeong;Kim, Sung-Il;Park, Jae-Soon;Joung, Yeun-Ho;Choi, Won Seok
    • Transactions on Electrical and Electronic Materials
    • /
    • v.16 no.1
    • /
    • pp.42-45
    • /
    • 2015
  • The ability to take electrocardiographic measurements while performing our daily activities has become the people-choice for modern age vital sign sensing. Currently, wet and dry ECG electrodes are known to pose threats like inflammations, allergic reactions, and metal poisoning due to their direct skin interaction. Therefore, the main goal in this work is to implement a very small ECG sensor system with a capacitive coupling, which is able to detect electrical signals of heart at a distance without the conductive gel. The aim of this paper is to design, implement, and characterize the contactless ECG electrodes. Under a careful consideration of factors that affect a capacitive electrode functional integrity, several different sizes of ECG electrodes were designed and tested with a pilot ECG device. A very small cotton-insulated copper tape electrode ($2.324cm^2$) was finally attained that could detect and measure bioelectric signal at about 500 um of distance from the subject's chest.