• Title/Summary/Keyword: electronic skin

Search Result 249, Processing Time 0.035 seconds

The Development of ACNR Conductor( I ) - Mechanical Properties (ACNR가공송전선의 개발( I ) - 기계적 특성)

  • Kim, Shang-Shu;Kim, Byung-Geol;Lee, Hee-Woong;Park, Joo-Hwan
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.635-636
    • /
    • 2005
  • 최근에 미국이나 러시아를 중심으로 가공승전선의 승전효율을 증대시키고자 하는 연구가 활발히 이루어지고 있으며 어느 정도 성과를 거두고 있다. ACSR가공송전선에서 교류전류의 흐름에 의하여 코어 (Core)에 자기장이 발생되어 투자율이 증가되고 이로 인하여 알루미늄층에서 전류밀도의 재 분포, skin effect 등으로 인하여 전력손실이 발생된다. 본 연구에서는 기존의 ACSR가공송전선의 코어 (Core)인 고탄소강선 대신에 비자성이면서 고강도인 새로운 강선을 코어재료로 채택한 ACNR(Aluminum Conductor Nonmagnetic Steel Reinforced)가공송전선을 개발하여 전력손실을 감소시켰다.

  • PDF

An electronic auscultation system design using a polymer based adherent differential output sensor (Polymer based adherent differentil output sensor를 이용한 전자 청진 시스템 설계)

  • 한철규;고성택;최민주
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2000.08a
    • /
    • pp.185-188
    • /
    • 2000
  • Heart sound contains rich information regarding the dynamics of the heart and the auscultation has been a first choice of routine procedures for diagnosis of the heart. However, heart sounds captured using a conventional stethoscope are not often loud or clear enough for doctors to precisely classify their characteristics, especially, under the noisy environments of the hospital. A simple auscultation device that removed shortcomings of the conventional stethoscope was constructed in the study. The device employed a polymer based adherent differential output sensor which was on contact with skin through a coupling medium and appropriated electronic circuits for signal amplification and conditioning. An ordinary headphone is taken to hear the captured heart sounds and the volume can be adjusted to hear well. It is also possible that the device sends the captured heart sound signals to a PC where the signals are further processed and viualized.

  • PDF

Study on the MTTF of Multi Wave Lengths IR and NIR LEDs Module (다파장 IR과 NIR 모듈의 평균 수명 예측에 관한 연구)

  • Kim, Dong Pyo;Kim, Kyung Seob
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.34 no.1
    • /
    • pp.44-49
    • /
    • 2021
  • Recently, infrared (IR) and near-infrared (NIR) light-emitting diodes (LEDs) were widely used for home medical applications owing to its low output power and wide exposed area for curing. For deep penetration of the light under the skin, multiple LEDs with wavelengths of 700~10,000 nm were located on a flexible printed circuit board. When multiple wavelengths of LEDs were soldered on a circuit board, the lifetime of LED module highly depends on LEDs with a short lifetime. The mean time to failure (MTTF) was able to calculate with the experimental results under high temperature and the Arrhenius model. The results of this study could help companies to approve the warranty of LED modules and its product.

Regional Skin Maximal Elongation Rate for Appling E-textiles to Tight-Fit Clothing (전자섬유의 피부 밀착의복 적용을 위한 인체 부위별 피부 최대변형률)

  • Jung, Dahee;Kim, So-Yeon;Sohn, Arim;Jeon, Bo-Young;Kim, Seon-Young;Lee, Joo-Young
    • The Korean Journal of Community Living Science
    • /
    • v.28 no.3
    • /
    • pp.365-375
    • /
    • 2017
  • The purpose of this study was to investigate the maximal elongation rate and area expansion ratio of human skin in various postures. Five males and five females (male: $23{\pm}2yr$ in age, $177.9{\pm}4.8cm$ in height, $76.7{\pm}8.8kg$ in body weight, $24.2{\pm}2.5$ in BMI, $16.2{\pm}3.4%$ in body fat; female: $22{\pm}1yr$, $163.2{\pm}3.6cm$, $51.4{\pm}2.7kg$, $19.3{\pm}1.6$, $27.4{\pm}6.7%BF$) participated in this study. Measurements were conducted using a pen and tape on the elbow, knee, wrist, shoulder, and neck. Subjects held postures so that each joint of the body regions was bent at its maximal level. The results were as follows: 1) The maximal elongation rate of skin showed a significant difference among the regions: $16.6{\pm}3.4%$ for the wrist, $22.4{\pm}5.5%$ for the neck (back), $37.6{\pm}11.3%$ for the shoulder, $42.6{\pm}10.0%$ for the knee, and $43.9{\pm}4.0%$ for the elbow (p<0.05). 2) The maximal expansion rate of the body surface area had the greatest values on the elbow ($93.7{\pm}6.4%$) and knee ($74.8{\pm}10.8%$). 3) No significant difference was found between males and females. In summary, maximal values of skin elongation and expansion rates in vivo were greater than in vitro values known from previous reports. These results can be applied to develop electronic fibers or textiles for wearable tight fit work clothing as well as fitness wear.

A Study on Development of Wrinkle Evaluation Software and Verification of Skin Wrinkle Improvement of Cog Suture (주름 평가 소프트웨어 개발과 Cog형 봉합사의 피부 주름 개선 검증에 관한 연구)

  • Jeong, Jin-Hyoung;Lee, Sang-Sik
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.12 no.4
    • /
    • pp.336-342
    • /
    • 2019
  • With the entry of an aging society, the average life span of accreditation has been extended. Therefore, interest in the appearance of men and women in modern society has increased. It is the wrinkles of the face that can judge the most outwardly. People tend to have various kinds of treatments to have a clean, wrinkle-free and resilient healthy skin regardless of sex. There is a lot of practice of lifting procedures in one of the procedures. A suture using a melting thread is a method of lifting by squeezing it into the skin as a non-incision type centering on a region where the thread can be fixed in the skin by injecting it into the subcutaneous fat layer. To evaluate the lifting efficacy of Cog - type suture for the improvement of skin wrinkles, preclinical experiments were conducted. We developed a wrinkle evaluation program using Labview. Data from preclinical experiments were used at 8 weeks after suturing. The average wrinkle depth was 415.6 mm in the control group. At 8 weeks, the depth of wrinkles was deepened to 888.3mm due to the aging process of the control group. On the other hand, the depth of the wrinkles before surgery was 640.3 mm in the suture group. It was confirmed that the depth of wrinkles decreased to 566.5mm at 8th week after the suture operation.

Fabrication and Characterization of Triboelectric Nanogenerator based on Porous Animal-collagen (다공성 동물성-콜라겐을 이용한 마찰전기 나노발전기 제작 및 특성평가)

  • Shenawar Ali Khan;Sheik Abdur Rahman;Woo Young Kim
    • Journal of the Korean Applied Science and Technology
    • /
    • v.40 no.1
    • /
    • pp.179-187
    • /
    • 2023
  • Nanogenerators containing biomaterials are eco-friendly electronic devices in terms of being a non-polluting energy source and biodegradable electronic waste. In particular, the amount of waste will be also reduced if the biomaterial can be extracted from biowaste. In this study, a triboelectric nanogenerator was fabricated using animal collagen present in the skin of a mammal and its characteristion was proformed. The electro-anodic layer of the triboelectric nanogenerator was constructed by forming a collagen film using the spin coating method, and it was confirmed that the film was porous from scanning electron microscopy. The fabricated triboelectric nanogenerator exhibited an open-circuit voltage from 7 V at 3 Hz to 15 V at 5 Hz due to periodic mechanical movement, and a short-circuit current of 3.8 uA at 5 Hz. In conclusion, collagen-containing triboelectric nanogenerators can be power source for low-power operating devices such as sensors and are also expected to be useful for reducing electronic waste.

The Experimental Estimation of the Effect on the Body Heat by the Artemisia-Lotion Pad

  • Jo, Bong-Kwan;Ko, Yeong-Guy;Jang, Sang-Yeoul;Bae, Jong-Il;Kim, Jong-Kyung;Lee, Dong-Cheol;Lee, Dong-Young;Lee, Ho-Jin;Jo, Bong-Jo;Gu, Ja-Seung;Kwon, Mi-Ja
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2206-2208
    • /
    • 2003
  • This paper is performed to find the effects on body heat by stimulating the skin with the heat of a moxibustion cauterizer and the Artemisia-lotion which cause the extension of the blood vessel. The Artemisia-lotion is made by extracting the vasodilator and antioxidant compounds from the $Artemisia-CH_2Cl_2$ fraction. The moxibustion cauterizer is constructed with a DC power supply and 3 heating electrodes with PTC(Positive Temperature Coefficients) thermistor. The stimulation temperature level of the moxibustion cauterizer is $45^{\circ}C\;-48^{\circ}C$. We gave the subjects the following stimulating conditions; only heat stimulation, only Artemisia -lotion stimulation, and both stimulations. The measurement of body heat was performed with a infrared thermography system . Finally we could estimate the effects of a betterment of circulation of the blood from $Artemisia-CH_2Cl_2$ fraction.

  • PDF

Electronic structure and magnetism of catalytic material Pt3Ni surfaces: Density-functional study

  • Sharma, Bharat Kumar;Kwon, Oryong;Odkhuu, Dorj;Hong, Soon Cheol
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2012.11a
    • /
    • pp.172-172
    • /
    • 2012
  • A Pt-skin $Pt_3Ni$(111) surface was reported to show high catalytic activity. In this study, we investigated the magnetic properties and electronic structures of the various oriented surfaces of bulk-terminated and Pt-segregated $Pt_3Ni$ by using a first-principles calculation method. The magnetic moments of Pt and Ni are appreciably enhanced at the bulk-terminated surfaces compared to the corresponding bulk values, whereas the magnetic moment of Pt on the Pt-segregated $Pt_3Ni$(111) surface is just slightly enhanced because of the reduced number of Ni neighboring atoms. Spin-decomposed density of states shows that the dz2 orbital plays a dominant role in determining the magnetic moments of Pt atoms in the different orientations. The lowering of the d-band center energy (-2.22 eV to -2.46 eV to -2.51 eV to -2.65 eV) in the sequence of bulk-terminated (100), (110), (111), and Pt-segregated (111) may explain the observed dependence of catalytic activity on surface orientation. Our d-band center calculation suggests that an observed enhanced catalytic activity of a $Pt_3Ni$(111) surface originates from the Pt-segregation.

  • PDF

A New Accurate Interconnect Delay Model and Its Experiment Verification (연결선에 기인한 시간지연의 정확한 모델 및 실험적 검증)

  • Yoon, Seong-Tae;Eo, Yung-Seon;Shim, Jong-In
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.9
    • /
    • pp.78-85
    • /
    • 2000
  • A new analytical VLSI interconnect delay model is presented and its accuracy is experimentally verified. In the model, the transmission line parameter variations due to skin effect, proximity effect, and silicon substrate effect are taken into account. That is, the circuit model of the interconnect line that includes these effects is newly developed and analyzed. For the model verification, test patterns combined the coplanar structure with microstrip were designed by using 0.35${\mu}m$ CMOS process technology. It is shown that the accuracy of the model is less than about 10% error.

  • PDF

A Fast and Accurate Face Tracking Scheme by using Depth Information in Addition to Texture Information

  • Kim, Dong-Wook;Kim, Woo-Youl;Yoo, Jisang;Seo, Young-Ho
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.707-720
    • /
    • 2014
  • This paper proposes a face tracking scheme that is a combination of a face detection algorithm and a face tracking algorithm. The proposed face detection algorithm basically uses the Adaboost algorithm, but the amount of search area is dramatically reduced, by using skin color and motion information in the depth map. Also, we propose a face tracking algorithm that uses a template matching method with depth information only. It also includes an early termination scheme, by a spiral search for template matching, which reduces the operation time with small loss in accuracy. It also incorporates an additional simple refinement process to make the loss in accuracy smaller. When the face tracking scheme fails to track the face, it automatically goes back to the face detection scheme, to find a new face to track. The two schemes are experimented with some home-made test sequences, and some in public. The experimental results are compared to show that they outperform the existing methods in accuracy and speed. Also we show some trade-offs between the tracking accuracy and the execution time for broader application.