• Title/Summary/Keyword: electronic control

Search Result 7,294, Processing Time 0.2 seconds

Body Weight Changes and Lifestyle in Women within 1 year after Childbirth (여성의 출산 후 체중변화와 생활양식)

  • Chung, Chae Weon;Kim, Hyewon;Kim, Hyojung
    • Perspectives in Nursing Science
    • /
    • v.13 no.2
    • /
    • pp.88-95
    • /
    • 2016
  • Purpose: Gestational weight gain and prepregnancy body weight are important factors of childbirth outcomes, which further cause obesity, metabolic diseases, or psychological problems later in women's lives. Changes in diet, westernized lifestyle, traditional postpartum care, and childbirth at older age are thought to be threats to proper weight management in Korean women of reproductive age. Public health and antenatal care need to focus on the proper body weight management of women by carefully planning pregnancy to postpartum periods. Purpose: This study explored the body weight changes from pregnancy to postpartum and the related characteristics in women within 12 months after childbirth. Methods: A cross-sectional, retrospective study was conducted with 102 Korean women within 12 months after childbirth. Data were collected using an online survey system, and a structured questionnaire available for electronic self-administration was modified to include demographics, obstetrical history, and body weight at 6 time points. The International Physical Activity Questionnaire and Eating Habit Measurement instruments were also used in data collection. A professional survey agency recruited the participants, and data were automatically saved and then analyzed. Results: The average age of the participants was 33.8 years, 48% were housewives and were well-educated. Seventy-two percent of the participants were primiparas and 82% had breastfed their babies. The body mass index (BMI) ranged from 17.3 to 27.8, indicating that 21.5% of the participants were overweight or obese. The mean gestational weight gain was 11.8 kg, and weight loss was apparent during the first 3 months postpartum. The mean decline in weight was 3.4 kg at one year after childbirth. Women wanted to lose 5.6 kg (range: 3~20 kg), however 44% of them reported that they had not engaged in any weight control efforts. Further, 72% of them reported having engaged in a low level of physical activity. Body weight was not associated with women's characteristics, physical activity score, and diet. Conclusion: Women's awareness of gestational weight gain, lifestyle modification, and the risk of prolonged weight retention should be promoted through the antenatal and women's healthcare systems. As pregnancy and childbirth are critical events that affect women's health, integrative education to ensure healthy transition to life after delivery is required.

Smart Headlamp Optics Design with Multi-array LEDs (멀티 어레이 엘이디를 이용한 지능형 전조등 광학 설계)

  • Yu, Jin Hee;Ro, Suk Ju;Lee, Jun Ho;Hwang, Chang Kook;Go, Dong Jin
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.5
    • /
    • pp.231-236
    • /
    • 2013
  • We investigated the optical design of a smart headlamp capable of producing various beam patterns through only on/off modulation of light sources. This was implemented by forming a continuous matrix of beams from discontinuous beam patterns by means of a multi-array LED optical system. As one such optical system, the multi-array LED system is a convenient and economical device for implementing beam patterns with the simple on/off modulation of the light sources. A single optical assembly module can be made by combining a multiple-LED array, optical system module, and electronic control with no need for any additional mechanical components. The present optical system was designed to include a secondary lens and a projection lens mounted at the front of each LED in the array to realize accurate lighting patterns as well as the required luminosity at a distance of 25 m in the forward direction. Finally, we identified and analyzed the patterns implemented by the designed optical system that produced satisfactory performance of high beams and adaptive driving beams (ADB).

The Comparative Study between Korean and Indian Students regarding Relationship among Self-leadership Types, Performance and Class Attendance Attitudes (학습태도를 매개변수로 한 셀프리더십 유형과 학업성과간 관계: 한국과 인도간 비교연구)

  • Park, Ki-Ho;Park, Sang-Hyeok
    • Journal of Digital Convergence
    • /
    • v.9 no.4
    • /
    • pp.253-265
    • /
    • 2011
  • A number of organizations have had big interests in studies concerning leadership and not only academia but also psychological areas do also. Until now, leadership has been accentuated by managers or team leaders especially. Recently, however, the concept of self-leadership directing one's own activities through self-control or self-management is being focused on in practices and in academia. This study is to investigate the influence between self-leadership strategies as predictors and learning performance in IT classes as dependents variables mediated by attitude of attendance focused on the social science students in two universities (Korea(116 samples) and India(36 samples)). And this research tried to compare difference between two university students. As a result of empirical analysis, Korean learners making an effort by themselves show a tendency to think constructively. Namely, even though the level of difficulty may be high, by positive self-talk, respondents usually make an effort to get high academic performance. In case of Indian respondents, students who are in behavior-oriented show higher academic performance. Research results can give us direction of task-taking attitudes in firms or learning attitudes in teaching organizations and implications to human resource managers who are in charge of improving learning performance or productivity.

A Study on the Automatic Generation of Test Case Based on Source Code for Quality Improvement (소프트웨어 품질향상을 위한 소스코드 기반의 테스트 케이스 자동 생성에 관한 연구)

  • Son, Ung-Jin;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.19 no.2
    • /
    • pp.186-192
    • /
    • 2015
  • This paper proposes an automatic generation technology of test case based on API in source code for software's quality improvement. The proposed technology is comprised of four processes which are analyzing source code by using the Doxygen open source tool, defining API specification by using analyzed results, creating test design, generating a test case by adapting Pairwise test technology. Analyzing source code by using the Doxygen open source tool is the phase in which API information in source code such as the API name, input parameter and return parameter are extracted. Defined API specification by using analyzed results is the phase where API informations, which is needed to generate test case, are defined as a form of database by SQLite database on the basis of extracted API information. Creating test design is the phase in which the scenario is designed in order to be composed as database by defining threshold of input and return parameters and setting limitations based on the defined API. Generating a test case by adapting Pairwise test technique is the phase where real test cases are created and changed into database by adapting Pairwise technique on the base of test design information. To evaluate the efficiency of proposed technology, the research was conducted by begin compared to specification based test case creation. The result shows wider test coverage which means the more cases were created in the similar duration of time. The reduction of manpower and time for developing products is expected by changing the process of quality improving in software developing from man-powered handwork system into automatic test case generation based on API of source code.

A Study on FPGA Design for Rotating LED Display Available Video Output (동영상 표출이 가능한 회전 LED 전광판을 위한 FPGA 설계에 관한 연구)

  • Lim, Young-Sik;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.19 no.2
    • /
    • pp.168-175
    • /
    • 2015
  • In this paper, we propose FPGA design technique for rotating LED display device which is capable of displaying videos with the use of the afterimage effect. The proposed technique is made up of image data correction process based on inverse gamma correction and error diffusion, block interleaving process, and data serial output process. The data correction process based on inverse gamma correction and error diffusion is an image data correction step in which image data received are corrected by inverse gamma correction process to convert the data into linear brightness characteristics, and by error diffusion process to reduce the brightness reduction phenomenon in low-gray-level which is caused by inverse gamma correction. In the block interleaving process, the data of the frames entered transversely are first saved in accordance with entrance order, and then only the longitudinal image data are read. The data serial output process is applied to convert the parallel data in a rotating location into serial data and send them to LED Driver IC, in order to send data which will be displayed on high-speedy rotating LED Bar. To evaluate the accuracy of the proposed FPGA design technique, this paper used XC6SLX45-FG484, a Spartan 6 family of Xilinx, as FPGA, and ISE 14.5 as a design tool. According to the evaluation analysis, it was found that goal values were consistent with simulation values in terms of accurate operation of inverse gamma and error diffusion correction, block interleaving operation, and serialized operation of image data.

Revised STandards for Reporting Interventions in Clinical Trials of Acupuncture(STRICTA) : Extending the CONSORT Statement (STRICTA(침 임상연구에서 중재 보고를 위한 표준) 개정판: CONSORT Statement의 확충안)

  • Lee, Hyang-Sook;Cha, Su-Jin;Park, Hi-Joon;Seo, Jung-Chul;Park, Jong-Bae J.;Lee, Hye-Jung
    • Korean Journal of Acupuncture
    • /
    • v.27 no.3
    • /
    • pp.1-23
    • /
    • 2010
  • Objectives and methods : The Standards for Reporting Interventions in Clinical Trials of Acupuncture (STRICTA) were published in five journals in 2001 and 2002. These guidelines, in the form of a checklist and explanations for use by authors and journal editors, were designed to improve reporting of acupuncture trials, particularly the interventions, thereby facilitating their interpretation and replication. Subsequent reviews of the application and impact of STRICTA have highlighted the value of STRICTA as well as scope for improvements and revision. To manage the revision process a collaboration between the STRICTA Group, the CONSORT Group, and the Chinese Cochrane Centre was developed in 2008. An expert panel with 47 participants was convened that provided electronic feedback on a revised draft of the checklist. At a subsequent face-to-face meeting in Freiburg, a group of 21 participants further revised the STRICTA checklist and planned dissemination. Results : The new STRICTA checklist, which is an official extension of CONSORT, includes six items and 17 sub-items. These set out reporting guidelines for the acupuncture rationale, the details of needling, the treatment regimen, other components of treatment, the practitioner background, and the control or comparator interventions. In addition, and as part of this revision process, the explanations for each item have been elaborated, and examples of good reporting for each item are provided. In addition, the word "controlled" in STRICTA is replaced by "clinical", to indicate that STRICTA is applicable to a broad range of clinical evaluation designs, including uncontrolled outcome studies and case reports. Conclusions : It is intended that the revised STRICTA, in conjunction with both the main CONSORT Statement and extension for nonpharmacologic treatment, will raise the quality of reporting of clinical trials of acupuncture.

Development of an EEG Software for Two-Channel Cerebral Function Monitoring System (2채널 뇌기능 감시 시스템을 위한 뇌파 소프트웨어의 개발)

  • Kim, Dong-Jun;Yu, Seon-Guk;Kim, Seon-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.1
    • /
    • pp.81-90
    • /
    • 1999
  • This paper describes an EEG(electroencephalogram) software for two-channel cerebral function monitoring system to detect the cerebral ischemia. In the software, two-channel bipolar analog EEG signals are digitized and from the signals various EEG parameters are extracted and displayed on a monitor in real-time. Digitized EEG signal is transformed by FFT(Fast Fourier transform) and represented as CSA(compressed spectral array) and DSA(density spectral array). Additional 5 parameters, such as alpha ratio, percent delta, spectral edge frequency, total power, and difference in total power, are estimated using the FFT spectra. All of these are effectively merged in a monitor and displayed in real-time. Through animal experiments and clinical trials on men, the software is modified and enhanced. Since the software provides raw EEG, CSA, DSA, simultaneously with additional 5 parameters in a monitor, it is possible to observe patients multilaterally. For easy comparison of patient's status, reference patterns of CSA, DSA can be captured and displayed on top of the monitor. And user can mark events of surgical operation and patient's conditions on the software, this allow him jump to the points of events directly, when reviewing the recorded EEG file afterwards. Other functions, such as forward/backward jump, gain control, file management are equipped and these are operated by simple mouse click. Clinical tests in a university hospital show that the software responds accurately according to the conditions of patients and medical doctors can use the software easily.

  • PDF

Conduction Path Dependent Threshold Voltage for the Ratio of Top and Bottom Oxide Thickness of Asymmetric Double Gate MOSFET (비대칭 이중게이트 MOSFET의 상하단 산화막 두께비에 따른 전도중심에 대한 문턱전압 의존성)

  • Jung, Hakkee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.11
    • /
    • pp.2709-2714
    • /
    • 2014
  • This paper has analyzed the change of threshold voltage and conduction path for the ratio of top and bottom gate oxide thickness of asymmetric double gate MOSFET. The asymmetric double gate MOSFET has the advantage that the factor to be able to control the current in the subthreshold region increases. The analytical potential distribution is derived from Poisson's equation to analyze the threshold voltage and conduction path for the ratio of top and bottom gate oxide thickness. The Gaussian distribution function is used as charge distribution. This analytical potential distribution is used to derive off-current and subthreshold swing. By observing the results of threshold voltage and conduction path with parameters of bottom gate voltage, channel length and thickness, projected range and standard projected deviation, the threshold voltage greatly changed for the ratio of top and bottom gate oxide thickness. The threshold voltage changed for the ratio of channel length and thickness, not the absolute values of those, and it increased when conduction path moved toward top gate. The threshold voltage and conduction path changed more greatly for projected range than standard projected deviation.

Genome-Wide Association Analyses on Blood Pressure Using Three Different Phenotype Definitions

  • Park, Ji-Wan;Uhmm, Saan-Yong;Shin, Chol;Cho, Nam-H.;Cho, Yoon-Shin;Lee, Jong-Young
    • Genomics & Informatics
    • /
    • v.8 no.3
    • /
    • pp.108-115
    • /
    • 2010
  • Hypertension is the most prevalent disease worldwide and is itself a risk factor for cerebral, cardiac, and renal diseases. The inconsistency of candidate genes suggested by previous genomewide association studies (GWASs) may be due to not only differences in study design and genetic or environmental background but also the difference in the power of analysis between continuous traits and discrete traits. We analyzed 352,228 single nucleotide polymorphisms (SNPs) in 8842 unrelated Koreans obtained from Ansan and Ansung cohorts. We performed a series of GWA analyses using three different phenotype models; young hypertensive cases (278 subjects) versus elderly normotensive controls (680 subjects); the upper 25% (2211 hypertensive cases) versus the lower 25% of the SBP distribution (2211 hypotensive controls); and finally SBP and DBP as continuous traits (8842 subjects). The numbers of young hypertensive cases and elderly normotensive controls were not large enough to achieve genomewide significance. The model comparing the upper 25% subjects to the lower 25% of subjects showed a power that was approximate to that of QTL analysis. Two neighboring SNPs of the ATP2B1 gene, rs17249754 (SBP, p=$2.53^{-10}$; DBP, p=$1.28{\times}10^{-8}$) and rs7136259 (SBP, p=$1.30{\times}10^{-9}$; DBP, p=$6.41{\times}10^{-8}$), were associated with both SBP and DBP. Interestingly, a SNP of the RPL6 gene, rs11066280, revealed a significant genomewide association with SBP in men only (p=$3.85{\times}10^{-8}$), and four SNPs located near the MAN2A1 gene showed a strong association with DBP only in elderly men aged 60-70 years (e.g., rs6421827, p=$4.86{\times}10^{-8}$). However, we did not observe any gene variant attaining genomewide significance consistently in the three phenotype models except for the ATP2B1 gene variants. In general, the association signal with blood pressure was stronger in women than in men. Genes identified in GWASs are expected to open the way for prevention, early diagnosis, and personalized treatment of hypertension.

PRODUCT10N OF KSR-III AIRGLOW PHOTOMETERS TO MEASURE MUV AIRGLOWS OF THE UPPER ATMOSPHERE ABOVE THE KOREAN PENINSULAR (한반도 상공의 고층대기 중간 자외선 대기광 측정을 위한 KSR-III 대기광도계 제작)

  • Oh, T.H.;Park, K.C.;Kim, Y.H.;Yi, Y.;Kim, J.
    • Journal of Astronomy and Space Sciences
    • /
    • v.19 no.4
    • /
    • pp.305-318
    • /
    • 2002
  • We have constructed two flight models of airglow photometer system (AGP) to be onboard Korea Sounding Rocket-III (KSR-III) for detection of MUV dayglow above the Korean peninsular. The AGP system is designed to detect dayglow emissions of OI 2972${\AA}$, $N_2$ VK(0,6) 2780${\AA}$, $N_2$ 2PG 3150${\AA}$ and background 3070${\AA}$ toward the horizon at altitudes between 100 km and 300 km. The AGP system consists of a photometer body, a baffle an electronic control unit and a battery unit. The MUV dayglow emissions enter through a narrow band interference filter and focusing lens of the photometer, which contains an ultraviolet sensitive photomultiplier tube. The photometer is equipped with an in-flight calibration light source on a circular plane that will rotate at the rocket's apogee. A bane tube is installed at the entry of the photometer in order to block strong scattering lights from the lower atmosphere. We have carried out laboratory measurements of sensitivity and in-flight calibration light source for the AGP flight models. Although absolute sensitivities of the AGP flight models could not be determined in the country, relative sensitivities among channels are well measured so that observation data during rocket flight in the future can be analyzed with confidence.