• Title/Summary/Keyword: electron paramagnetic resonance

Search Result 96, Processing Time 0.033 seconds

Fingernail electron paramagnetic resonance dosimetry protocol for localized hand exposure accident

  • Jae Seok Kim;Byeong Ryong Park;Minsu Cho;Won Il Jang;Yong Kyun Kim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.1
    • /
    • pp.270-277
    • /
    • 2023
  • Exposure to ionizing radiation induces free radicals in human nails. These free radicals generate a radiation-induced signal (RIS) in electron paramagnetic resonance (EPR) spectroscopy. Compared with the RIS of tooth enamel samples, that in human nails is more affected by moisture and heat, but has the advantages of being sensitive to radiation and easy to collect. The fingernail as a biological sample is applicable in retrospective dosimetry in cases of localized hand exposure accidents. In this study, the dosimetric characteristics of fingernails were analyzed in fingernail clippings collected from Korean donors. The dose response, fading of radiation-induced and mechanically induced signals, treatment method for evaluation of background signal, minimum detectable dose, and minimum detectable mass were investigated to propose a fingernail-EPR dosimetry protocol. In addition, to validate the practicality of the protocol, blind and field experiments were performed in the laboratory and a non-destructive testing facility. The relative biases in the dose assessment result of the blind and field experiments were 8.43% and 21.68% on average between the reference and reconstructed doses. The results of this study suggest that fingernail-EPR dosimetry can be a useful method for the application of retrospective dosimetry in cases of radiological accidents.

A Study of Electron Paramagnetic Resonance of Sugar Irradiated X-ray (X-선에 조사된 설탕의 전자 상자성 공명 연구)

  • Ok, Chi-Il;Son, Phil-Kook;Heo, Kyoung-Chan;Shon, Jong-Gi;Lee, In;Kim, Jang-Whan
    • Journal of radiological science and technology
    • /
    • v.23 no.2
    • /
    • pp.39-42
    • /
    • 2000
  • When ordinary sugar is exposed to ionizing radiation, a number of free radical are created in sugar, and Electron Paramagnetic Resonance (EPR) signal appears from the sugar because of the paramagnetic property of free radical. In this paper, EPR signal intensity has been measured in x-ray irradiated sugar for various absorbed doses, irradiated dose up to 50 Gy. The EPR intensity signals are increased as the x-ray irradiation increases. Also, the fading value decreased to about 3% in 30day after the irradiation. Therefore, the sugar is a useful material for emergency dosimeter as the free radical dosimetry with the EPR equipment.

  • PDF

Temperature Dependence of Mn2+ Paramagnetic Ion in a Stoichiometric LiNbO3 Single Crystal

  • Yeom, Tae Ho;Lee, Soo Hyung
    • Journal of Magnetics
    • /
    • v.18 no.3
    • /
    • pp.221-224
    • /
    • 2013
  • Electron paramagnetic resonance (EPR) spectra of $Mn^{2+}$ impurity ion in Stoichiometric $LiNbO_3$ single crystal (SLN) was investigated with an X-band EPR spectrometer in the temperature range of 3 K~296 K. The intensity of EPR spectrum of $Mn^{2+}$ ion was increased to 20 K and decreased again below 20 K as the temperature decreases. The zero-field splitting parameter D decreased as the temperature increases. It was suggested that $Mn^{2+}$ ion substitute for $Nb^{5+}$ ion instead of $Li^+$ ion. No changes for hyperfine interaction of $Mn^{2+}$ ion was obtained in the temperature range of 3 K~296 K.

Pulsed Electron Paramagnetic Resonance Application on the Photoinduced Charge Separation of Alkylphenothiazine Derivatives in Molecular Assemblies

  • Kang, Young-Soo;Park, Chan-Young
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.4 no.2
    • /
    • pp.82-90
    • /
    • 2000
  • Photoinduced charge separation of alkylphenothiazines in molecular assemblies such as positively, negatively and neutrally charged micelle interface results in the paramagnetic phenothiazine cation radical. This was studied as a model system for the light energy conversion into chemical energy. The photoproduced phenothaizne cation radical was identified and its amount was quantized with electron spin resonance (ESR). The microenvironment of photoproduced cation radical was studied with pulsed-ESR. Such a charge separation is enhanced by the optimization of various structural factors of the molecular assemblies. The structural factors of molecular assemblies have focused on the interface charge, interface structure with different headgroups and interfacial perturbation by disolving interface active organic additives.

  • PDF

Development of a Wideband EPR Spectrometer with Microstrip and Loop Antennas

  • Ponomaryov, A.N.;Choi, K.Y.;Suh, B.J.;Jang, Z.H.
    • Journal of Magnetics
    • /
    • v.18 no.2
    • /
    • pp.178-182
    • /
    • 2013
  • We have developed a new non-conventional electron paramagnetic resonance (EPR) spectrometer, in which no resonant cavity was used. We previously demonstrated a wide frequency range operation of an EPR spectrometer using two loop antennas, one for a microwave transmission and the other for signal detection [1]. In contrast to Ref. [1], the utilization of a microstrip antenna as a transmitter enhanced a capability of wide-band operation. The replacement of conventional capacitors with varactor diodes makes resonance condition easily reproducible without any mechanical action during tuning and matching procedure since the capacitance of the diodes is controlled electronically. The operation of the new EPR spectrometer was tested by measuring a signal of 1,1-diphenil-2-picrylhydrazyl (DPPH) sample in the frequency range of 0.8-2.5 GHz.

Electron Paramagnetic Resonance Study of impurity Fe3+ ion in LiTaO3 single crystal (Fe3+ 불순물이 첨가된 LiTaO3 단결정에서의 전자 상자성 공명 연구)

  • Min, S.G.;Yeon, T.H.;Lee, S.H.;Lee, M.K.;Shin, H.K.;Yu, Y.M.;Kim, T.H.;Yu, S.C.
    • Journal of the Korean Magnetics Society
    • /
    • v.13 no.4
    • /
    • pp.171-175
    • /
    • 2003
  • Electron paramagnetic resonance (EPR) of Fe$^{3+}$ in LiTaO$_3$ single crystal, grown by Czochralski method, has been studied by employing an X-band spectrometer. Resonance spectra of Fe$^{3+}$ ion on the crystallographic principal axes were obtained with 9.447 ㎓ at room temperature. The spectroscopic splitting parameter g and zero-field splitting (ZFS) parameter D (= 3 B$_{2}$sup 0/) are calculated with effective spin Hamiltonian. Fe$^{3+}$ center in stoichometric single crystal turns out to be different with that in congruent single crystal reported previously. From the analysis of temperature dependence of resonance fields for Fe$^{3+}$ ion, there is no any phase transition at the temperature range (from -160 $^{\circ}C$ to 20 $^{\circ}C$).

Characteristics of MnxSi1-xTe Compound Studied by Electron Magnetic Resonance and Other Experiments

  • Na, Sung-Ho;Kim, Heung-Chul;Park, Jung-Woo;Kim, Jang-Whan
    • Journal of Magnetics
    • /
    • v.13 no.1
    • /
    • pp.23-29
    • /
    • 2008
  • The magnetic and other physical characteristics of $Mn_xSi_{1-x}Te$ have been investigated by electron magnetic resonance (EMR), X-ray diffraction (XRD) and other experiments. $Mn_xSi_{1-x}Te$ is found to have corundum structure for manganese contents up to 10% and also to be ferromagnetic for temperatures below 80 K. While ferromagnetic resonance signal coexists with the usual paramagnetic resonance signal, invariance of the g-factor inferred from the electron paramagnetic resonance signals throughout all temperature ranges clearly confirms that the manganese ions are in the electronic 3d5 state. The temperature dependence of EMR line-width is the same as other diluted magnetic semiconductors. From the EMR signals relaxation times $T_2$ and $T_1$ of $Mn_xSi_{1-x}Te$ compounds are estimated to be about $4.4{\times}10^{-10}s$ and $9.3{\times}10^{-8}s$ respectively and are found to vary slightly with temperature or composition change. Exchange narrowing of the EMR line-width becomes dominant for the sample in which the substitution ratio, x = 30%. For one sample, in which x = 0.5%, spin glass-like behavior is indicated by EMR signals for temperatures lower than 60 K. This behavior may authentic for samples within a certain range of x.

Electron Paramagnetic Resonance Study on the Photoproduced Cation Radical of N-Methylphenothiazine in the Gel Matrices

  • Lee, Don-Keun;Zhang, Dong-Ri;Kang, Youn-Soo
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.6 no.2
    • /
    • pp.103-112
    • /
    • 2002
  • The photoproduced cation radical of N-methylphenothiazine $(PC_1)$ doped into phenyltriehtoxysilane (PhiTEOS), vinyltriethoxysilane (VTEOS) and methyltriethoxysilane (METOS) was studied with electron spin resonance (ESR) and electron nuclear double resonance (ENDOR). The photoinduced charge separation efficiency was determined by integration of ESR spectra which correspond to the amount of photoproduced cation radical in the matrices. This was correlatively studied with the polarity and pore size of the gel matrices. The relative polarity of the matrices was determined by measuring ${\lambda}_{max}$ values of $PC_1$ in the different matrices. The relative pore size among the matrices was determined by measuring relative proton matrix ENDOR line widths of the photoproduced cation of $PC_1$. The decay kinetic constants of the cation radical of $PC_1$ in the different matrices with relatively studied with fitting the biexponential decay curves after exposure at the ambient condition. This is correlatively interpreted with the polarity and pore size of the matrices.

  • PDF

Second intercomparison on electron paramagnetic resonance (EPR) retrospective dosimetry in Korea using hydroxyapatite

  • HyoJin Kim;Jae Seok Kim;Byeong Ryong Park;Seongjae Jang;Han-Ki Jang;Ki-Taek Han;Hoon Choi;Jeongin Kim;In Jung Kim;Yunho Kim;Wi-Ho Ha;Jungil Lee;Yeong-Rok Kang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.12
    • /
    • pp.4576-4582
    • /
    • 2023
  • The Korea retrospective dosimetry (KREDOS)-electron paramagnetic resonance (EPR) group undertook an intercomparison investigation utilizing hydroxyapatite. This analysis involved four institutions: the Korea Institute of Radiological and Medical Sciences, Dongnam Institute of Radiological and Medical Sciences, Korean Association for Radiation Application, and Radiation Health Institute of Korea Hydro & Nuclear Power. Following the irradiation of the hydroxyapatite sample, the recorded build-up was analyzed. To validate the reliability of the EPR dosimetry findings and enhance its operational performance, a hydroxyapatite dose-response curve was plotted and dosimetry was performed for a blind sample. The proficiency of each laboratory was assessed by employing an interlaboratory comparison methodology. This involved a comparative analysis of the measurement results by calculating the relative bias, z-score, and En value. The results submitted by the participating laboratories demonstrated satisfactory ratings for doses of 1.006, 3.999, and 6.993 Gy. Following the second intercomparison, efforts to optimize their hydroxyapatite-EPR dosimetry systems are underway in the participating laboratories. The current assessment of hydroxyapatite dose yielded the foundational data required to establish the parameters of dental dosimetry. In future, the third intercomparison experiment will be conducted for exploring other materials.