• Title/Summary/Keyword: electron microscopic

Search Result 1,229, Processing Time 0.028 seconds

Isolation and Identification of Cellulase-producing Microorganism, and Determination of Optimal Culture Condition (토양으로부터 Cellulose 분해효소를 생산하는 미생물의 분리, 동정 및 최적배양조건의 결정)

  • Hahm, Byoung-Kwon;Kim, Yoon-Keun;Yu, Ju-Hyun;Bai, Dong-Hoon
    • Korean Journal of Food Science and Technology
    • /
    • v.29 no.5
    • /
    • pp.1028-1032
    • /
    • 1997
  • The strain No. 33, which produces cellulose-degrading enzyme, was isolated from soil. Yellow halo was identified when the culture supernatant of the strain was loaded onto agar plate containing 2.0% CMC using paper disc method. From scanning electron microscopic observation, the morphology of the stain was rod-shaped. For identification, several biochemical characteristics were tested, and this strain was identified to Bacillus sp. So, we named this strain as Bacillus sp. No. 33. The maximal growth was observed when the stain was cultured in the medium containing 1.0% glucose, 3.0% yeast extract, 0.5% $KH_2PO_4$, 0.02% $MgSO_4{\cdot}7H_2O$, pH 7.0 at $30^{\circ}C$ for 39 hours with shaking. The maximal enzyme production was accomplished using the medium containing 4.0% CMC, 2.0% yeast extract, 0.5% $KH_2PO_4$, 0.04% $MgSO_4{\cdot}7H_2O$, pH 7.0 at $30^{\circ}C$ for 42 hours with shaking.

  • PDF

AGING EFFECT ON THE MICROTENSILE BOND STRENGTH OF SELF-ETCHING ADHESIVES (자가부식 접착제의 미세인장접착강도에 대한 시효처리 효과)

  • Park, Jin-Seong;Kim, Jong-Sun;Kim, Min-Su;Son, Ho-Hyeon;Gwon, Hyeok-Chun;Cho, Byeong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.6
    • /
    • pp.415-426
    • /
    • 2006
  • In this study, the changes in the degree of conversion (DC) and the microtensile bond strength (MTBS) of self-etching adhesives to dentin was investigated according to the time after curing. The MTBS of Single Bond (SB, 3M ESPE, USA), Clearfil SE Bond (SE, Kuraray, Japan), Xeno-III (XIII, Dentsply, Germany), and Adper Prompt (AP, 3M ESPE, USA) were measured at 48h, at 1 week and after thermocycling for 5,000 cycles between 5$^{\circ}$C and 55$^{\circ}$C. The DC of the adhesives were measured immediately, at 48h and at 7 days after curing using a Fourier Transform Infra-red Spectrometer. The fractured surfaces were also evaluated with scanning electron microscope. The MTBS and DC were significantly increased with time and there was an interaction between the variables of time and material (MTBS, 2-way ANOVA, p = 0.018; DC, Repeated Measures ANOVA, p < 0.001). The low DC was suggested as a cause of the low MTBS of self-etching adhesives, XIII and AP, but the increase in the MTBS of SE and AP after 48h could not be related with the changes in the DC. The microscopic maturation of the adhesive layer might be considered as the cause of increasing bond strength.

SHEAR BOND STREGNTHS OF ONE-BOTTLE DENTIN ABHESIVE SYSTEMS (One-Bottle system 상아질접착제의 전단결합강도 해석)

  • Cho, Byeong-Hoon;Lim, Sung-Sam;Kwon, Hyuck-Choon;Um, Chung-Moon;Son, Ho-Hyun;Bae, Kwang-Sik
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.4
    • /
    • pp.546-553
    • /
    • 1999
  • In Older to evaluate the effectiveness of 'One-bottle dentin adhesive system', the shear bond strengths of two fourth generation dentin adhesive systems and two One-bottle systems to the occlusal dentin of the freshly extracted third molars were measured by the regulation of the ISO TR 11405. The fourth generation dentin adhesive systems used in this study were Scotchbond Multi-Purpose Plus and All-Bond 2, and the One-bottle systems were Single Bond and One-Step. The effects of the thickness of hybrid layer and adhesive layer, the diameter of resin tag and the ratio between the diameter of resin tag and that of dentinal tubule were analyzed as the contributing factors of the shear bond strength of dentin bonding systems from the Scanning Electron Microscopic images. The results were as follows: 1. The shear bond strengths of Scotchbond Multi-Purpose, All-Bond 2, and Single Bond were 16.98${\pm}$3.40 MPa, 15.10${\pm}$2.77 MPa and 15.05${\pm}$3.18 MPa, respectively. There were no statistical differences(p>0.05). 2. But, the shear bond strength of One-Step were significantly lower than those of the other groups (11.81${\pm}$1.95 MPa, p<0.05). 3. The thicknesses of hybrid layer and adhesive layer of One-Step were significantly thinner than those of the other groups(p<0.05). The differences of the diameter of resin tag(p=0.0685) and the ratio between the diameter of resin tag and that of dentinal tubule(p=0.2401) were not significant among all the material groups. 4. The thickness of hybrid layer and adhesive layer might be considered as contributing factors of the she at bond strengths of dentin bonding systems, but the diameter of resin tag and the ratio between the diameter of resin tag and that of dentinal tubule might not.

  • PDF

Characteristics of Tofu Added with Soybeans Cultured by Mycelia of Pleurotus eryngii (큰느타리버섯 균사체를 증식시킨 콩을 첨가제조한 두부의 품질특성)

  • Lee, Ka-Soon;Kim, Hong-Kyu;Oh, Man-Jin
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.35 no.8
    • /
    • pp.1038-1044
    • /
    • 2006
  • The effects of the addition of soybeans cultured by mycelia of Pleurotus eryngii (SMP) on the characteristics of tofu were studied. Protein and ash contents of SMP were higher than those of untreated soybeans: 43.23 and 6.34% for treated soybeans, respectively, and 40.42 and 5.90% for untreated soybeans. But lipid and carbohydrate contents of SMP were lower. For minor elements, Mg and Ca contents of SMP were higher and P was lower than control. Tofu could be manufactured when SMP was added below 25% to the untreated soybean. In scanning electron microscopic observation, tofu tended to break down as the ratio of SMP was over 25% to the untreated soybean. The addition of SMP $(5{\sim}15%)$ increased the yield of tofu to $1.5{\sim}3.5%$. In textural characteristics, hardness of tofu increased as the ratio of SMP increased up to 20%. Cohesiveness, chewiness, springiness and gumminess were high in tofu which was made with $5{\sim}15%$ SMP. Savory taste and overall acceptability of the tofu prepared with $5{\sim}15%$ SMP were higher than those of control when evaluated by sensory test.

A Study on Image Analysis of Graphene Oxide Using Optical Microscopy (광학 현미경을 이용한 산화 그래핀 이미지 분석 조건에 관한 연구)

  • Lee, Yu-Jin;Kim, Na-Ri;Yoon, Sang-Su;Oh, Youngsuk;Lee, Jea Uk;Lee, Wonoh
    • Composites Research
    • /
    • v.27 no.5
    • /
    • pp.183-189
    • /
    • 2014
  • Experimental considerations have been performed to obtain the clear optical microscopic images of graphene oxide which are useful to probe its quality and morphological information such as a shape, a size, and a thickness. In this study, we investigated the contrast enhancement of the optical images of graphene oxide after hydrazine vapor reduction on a Si substrate coated with a 300 nm-thick $SiO_2$ dielectric layer. Also, a green-filtered light source gave higher contrast images comparing to optical images under standard white light. Furthermore, it was found that a image channel separation technique can be an alternative to simply identify the morphological information of graphene oxide, where red, green, and blue color values are separated at each pixels of the optical image. The approaches performed in this study can be helpful to set up a simple and easy protocol for the morphological identification of graphene oxide using a conventional optical microscope instead of a scanning electron microscopy or an atomic force microscopy.

CHANGES IN THE SHAPE AND ULTRASTRUCTURE OF THE ARTICULAR DISC OF THE RAT MANDIBULAR JOINT WITH AGING (가령에 따른 백서 악관절 원판의 형태 및 미세구조적 변화)

  • Suh, Hye-Kyung;Kyung, Hee-Moon;Sung, Jae-Hyun;Bae, Yong-Chul
    • The korean journal of orthodontics
    • /
    • v.24 no.2
    • /
    • pp.331-348
    • /
    • 1994
  • The purpose of this study was to investigate changes in the shape and ultrastructure of the articular disc of the rat mandibular joint with aging. Mechanical stress applied to the articular disc changes during neonatal, suckling, juvenile, adult and senile stages. Mandibular joints of 6 groups of rats(1-, 7-, 17-, 27-, 55-day and over-1-year groups) were removed en bloc and processed for light and electro microscopic study. The changes in the shape of articular disc were examined by light microscope in each group. Structural and ultrastructural changes in the articular disc were examined by light and electron microscope in each group. The results were as follows : In the 1-day and 7-day groups, the articular disc was long and slender in shape and the articular disc was not fitted with the shape of the mandibular fossa and condyle. However' after that time, the anterior and posterior portions of the articular disc were more bulged and the middle portion was shorter and biconcave. Thus the articular disc was well fitted with the shape of the mandibular fossa and condyle. The cell density decreased with aging. In the l -day and 7-day groups, the Golgi apparatus, rough endoplasmic reticulum and free ribosome, which are involved in the synthesis of intracellular and extracellular matrix, were developed. In the 17-day, 27-day and 55-day groups, not only the cell organelles involved in the synthesis of the intracellular and extracellular matrix but also the cell organelles involved in the remodeling of the extracellular matrix(i.e., finger-like cell process, lysosome and mitochondria)were well developed. With advancing age, intracytoplasmic microfilaments were more accumulated and condroid cells increased. In the over-1-year group, the majority of cells of the articular disc were chondroid cells. The majority of cytoplasmic compartment were filled with intracytoplasmic microfilaments and cell organelles were not developed. Therefore, metabolic activities of the cell was markedly reduced and cells contained structures enduring mechanical stress, and cells which were in the process of degeneration were observed occasionally.

  • PDF

Quantitative Ultrastructural Analysis of Endings Presynaptic to the Tooth Pulp Afferent Terminals in the Trigeminal Oral Nucleus

  • Lee, Suk-Ki;Kim, Tae Heon;Lee, Cheon-Hee;Park, Sook Kyung;Bae, Yong Chul
    • International Journal of Oral Biology
    • /
    • v.41 no.3
    • /
    • pp.133-139
    • /
    • 2016
  • The ultrastructural parameters related to synaptic release of endings which are presynaptic to tooth pulp afferent terminals (p-endings) were analyzed to understand the underlying mechanism for presynaptic modulation of tooth pulp afferents. Tooth pulp afferents were labelled by applying wheat-germ agglutinin conjugated horseradish peroxidase to the rat right lower incisor, whereafter electron microscopic morphometric analysis with serial section and reconstruction of p-endings in the trigeminal oral nucleus was performed. The results obtained from 15 p-endings presynaptic to 11 labeled tooth pulp afferent terminals were as follows. P-endings contained pleomorphic vesicles and made symmetrical synaptic contacts with labeled terminals. The p-endings showed small synaptic release-related ultrastructural parameters: volume, $0.82{\pm}0.45{\mu}m^3$ ($mean{\pm}SD$); surface area, $4.50{\pm}1.76{\mu}m^2$; mitochondrial volume, $0.15{\pm}0.07{\mu}m^3$; total apposed surface area, $0.69{\pm}0.24{\mu}m^2$; active zone area, $0.10{\pm}0.04{\mu}m^2$; total vesicle number, $1045{\pm}668.86$; and vesicle density, $1677{\pm}684/{\mu}m^2$. The volume of the p-endings showed strong positive correlation with the following parameters: surface area (r=0.97, P<0.01), mitochondrial volume (r=0.56, P<0.05), and total vesicle number (r=0.73, P<0.05). However, the volume of p-endings did not positively correlate or was very weakly correlated with the apposed surface area (r=-0.12, P=0.675) and active zone area (r=0.46, P=0.084). These results show that some synaptic release-related ultrastructural parameters of p-endings on the tooth pulp afferent terminals follow the "size principle" of Pierce and Mendell (1993) in the trigeminal nucleus oralis, but other parameters do not. Our findings may demonstrate a characteristic feature of synaptic release associated with p-endings.

A Study on the Loss of Tooth Substance and Surface Changes following Root Planing (치근면 활택술후 치질삭제와 표면형태변화에 관한 연구)

  • Heo, Soo-Rye;Kim, Soo-Ah;Seo, Seok-Ran;Kim, Hyoug-Seop
    • Journal of Periodontal and Implant Science
    • /
    • v.28 no.2
    • /
    • pp.351-372
    • /
    • 1998
  • The purpose of this study was to evaluate in vitro effects of the loss of tooth substance and root surface changes following root planing with various periodontal instruments. The 39 extracted human teeth due to severe periodontal disease were included. The total 50 root surfaces of 30 teeth were root planed with following instruments : Group 1, with Gracey curette, Group 2, with ultrasonic scaler, Group 3, with rotating root planing bur, Group 4, with Gracey curette plus rubber cup polishing, and Group 5, with ultrasonic scaler plus rubber cup polishing. Following root planing, the amount of tooth substance loss was evaluated by measuring the weight of the removed tooth substance and then 5 specimens ($5{\times}5{\times}2mm$) were randomly selected from the each group for roughness measurement. Root planed areas of each specimen were subjected to five measurements using the Profilometer and an average surface roughness values(Ra) for each group was obtained. Statistical difference for roughness values of each group was analyzed using oneway ANOVA and student t-test. For scanning electron microscopic(SEM) examination of root surface changes following root planing, 15 root surfaces of remaining 9 teeth were root planed and 3 specimens were randomly selected. The mean loss of tooth substance removed was Group 1, $7.0{\pm}1.09mg$, Group 2, $1.3{\pm}1.00mg$, Group 3, $5.8{\pm}1.72mg$, Group 4, $8.7{\pm}1.34mg$, and Group 5, $4.5{\pm}1.68mg$ following root palning, respectively. These results indicate that curette is effective instrument in the respect of diseased root substance removal. The average surface roughness values are following results : Group 1 and Group 4 were the smoothest surface ($Ra=0.34{\pm}0.06{\mu}m$, $Ra=0.34{\pm}0.04{\mu}m$, respectively) and Group 2 was the roughest surface ($Ra=2.09{\pm}0.06{\mu}m$). Statistical analysis of roughness values demonstrated a highly significant difference (P<0.05) between each experimental groups. However, no statistically significant difference in roughness values were observed between the Group 1 and Group 4. The results in this study suggest that curette and/or polishing procedure should be done after root planing with ultrasonic scaler and caution should be used with dia-mond-coated bur during routine root planing procedure.

  • PDF

Microstructural Change of Implant Surface conditioned with Tetracycline-HCI;SLA and TB surface implant (표면처리 시간에 따른 임플란트 미세구조의 변화;SLA와 TB 표면 임플란트)

  • Woo, Jung-A;Herr, Yeek;Kwon, Young-Hyuk;Park, Joon-Bong;Chung, Jong-Hyuk
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.4
    • /
    • pp.921-937
    • /
    • 2005
  • Mechanical and chemical methods are the two ways to treat the implant surfaces. By using mechanical method, it is difficult to eliminate bacteria and by-products from the rough implant surface and it can also cause the structural change to the implant surface. Therefore, chemical method is widely used in order to preserve and detoxicate the implant surface more effectively. The purpose of this study is to evaluate the effect of tetracylcline- HCl on the change of implant surface microstructure according to application time. Implants with pure titanium machined surface, SLA surface and $TiO_2blasted$ surface were used in this study. Implant surface was rubbed with sponge soaked in 50mg/ml tetracycline - HCl solution for $\frac{1}{2}$ min., 1min., $1\frac{1}{2}$ min., 2 min., and $2\frac{1}{2}min.$ respectively in the test group and with no treatment in the control group. The sponge was soaked in every 30 seconds. Then, the specimens were processed for scanning electron microscopic observation. Based upon the analysis of photographs by three dentists who are not related with this study, the results were obtained as follows; 1. In the pure titanium machined surfaces, the control specimen showed a more or less rough machined surface composed of alternating positive and negative lines corresponding to grooves and ridges. After treatment, machining line was more pronounced for the control specimens. but in general, test specimens were similar to control. 2. In the SLA surfaces, the control specimen showed that the macro roughness was achieved by large-grit sandblasting. Subsequently, the acid-etching process created the micro roughness, which thus was superimposed on the macro roughness. Irrespective of the application time of 50mg/ml tetracycline - HCl solution, in general, test specimens were similar to control. 3. In the $TiO_2blasted$ surfaces, the control specimen showed the rough surface With small pits. The irregularity of the $TiO_2blasted$ surfaces with 50mg/ml tetracycline - HCl solution was lessened and the flattened areas got wider after 1 minute.

In vitro study of compressive fracture strength of Empress 2 crowns cemented with various luting agents

  • Kim Min-Ho;Yang Jae-Ho;Lee Sun-Hyung;Chung Hun-Young;Chang Ik-Tae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.3
    • /
    • pp.260-272
    • /
    • 2001
  • All-ceramic restorations have had a more limited life expectancy than metal ceramic restorations because of their low strength. Their relatively lower strength and resistance to fracture have restricted the use of all-ceramic crowns to anterior applications where occlusal loads are lower. But there has been increasing interest in all-ceramic restorations because patients are primarily concerned with improved esthetics. Many efforts have been made to in prove the mechanical properties of dental ceramics. This study was designed to elucidate the influence of the luting agent on the strength of the Empress 2 crown (staining technique) cemented on human teeth. Seventy extracted human permanent molar teeth were chosen. Teeth were prepared for Empress 2 crowns with milling machine on a surveyor. A dental bur was placed in the mandrel that was positioned so that the long axis of the bur was perpendicular to the surveyor base. Dimensions of the Empress 2 crown preparation were $6^{\circ}$ taper on each side, $1.5{\pm}0.1mm$ shoulder margin, and 4mm crown height. The luting cements used in this study were as follow: 1. Uncemented 2. Zinc phosphate cements (Confi-Dental) 3. Conventional glass ionomer cement : Fuji 1 (GC) 4. Resin-modified glass ionomer cements : Fuji plus (GC) 5. Adhesive cements : Panavia F (Kuralay), Variolink II (Vivadent), Choice (Bisco). Fracture test using Instron. The crowns were loaded in compressive force to evaluate the effect of these cements on the breaking strength of these all-ceramic crowns. A steel ball with a diameter of 4mm was placed on the occlusal surface and load was applied to the steel ball by a cylindrical bolt with a crosshead speed of 0.5mm per minute until fracture occurred. The fractured surface was examined using Scanning Electron Microscopic Image (SEM) to discover the correlation between fracture strength and bonding capacity. Within the limitation of this in vitro study design, the results were as follows : 1. fomentations significantly increased the fracture resistance of Empress ceramic crowns compared to control. Uncemented (206.9 N): ZPC (812.9 N): Fuji 1 (879.5 N): Fuji Plus (937.7 N): Choice (1105.4 N): Variolink II (1221.1 N): Panavia F (1445.2 N). 2. Resin luting agent, treated by a silane bond enhancing agents, yielded a significant increase in fracture resistance. In some of the Panavia F group, a fracture extended into dentin. 3. According to SEM images of fractured Empress crowns, the stronger the bond at both interfaces(crown and die), the more fracture strength was acquired.

  • PDF