• Title/Summary/Keyword: electromechanical responses

Search Result 29, Processing Time 0.02 seconds

Piezoelectric skin sensor for electromechanical impedance responses sensitive to concrete damage in prestressed anchorage zone

  • Dang, Ngoc-Loi;Pham, Quang-Quang;Kim, Jeong-Tae
    • Smart Structures and Systems
    • /
    • v.28 no.6
    • /
    • pp.761-777
    • /
    • 2021
  • This study presents a numerical investigation on the sensitivity of electromechanical (EM) impedance responses to inner damaged concrete of a prestressed anchorage zone. Firstly, the Ottosen yield criterion is selected to simulate the plasticity behavior of the concrete anchorage zone under the compressive loading. Secondly, several overloading cases are selected to analyze inner damage formations in the concrete of the anchorage zone. Using a finite element (FE) model of the anchorage zone, the relationship between applied forces and stresses is analyzed to illustrate inner plasticity regions in concrete induced by the overloading. Thirdly, EM impedance responses of surface-mounted PZT (lead-zirconate-titanate) sensors are numerically acquired before and after concrete damage occurrence in the anchorage zone. The variation of impedance responses is estimated using the RMSD (root-mean-square-deviation) damage metric to quantify the sensitivity of the signals to inner damaged concrete. Lastly, a novel PZT skin, which can measure impedance signatures in predetermined frequency ranges, is designed for the anchorage zone to sensitively monitor the EM impedance signals of the inner damaged concrete. The feasibility of the proposed method is numerically evaluated for a series of damage cases of the anchorage zone. The results reveal that the proposed impedance-based method is promising for monitoring inner damaged concrete in anchorage zones.

Dynamic response for electromechanical integrated toroidal drive to electric excitation

  • Xu, Lizhong;Hao, Xiuhong
    • Structural Engineering and Mechanics
    • /
    • v.26 no.6
    • /
    • pp.635-650
    • /
    • 2007
  • In this paper, the equivalent exciting force caused by electric excitation is derived. By dividing load and displacement vectors into mean values and time-varying ones, the dynamic equations of the system are transformed into linear ones for time-varying portion of the displacements. The analytical equations of the forced time responses of the drive system to electric excitations are obtained. Using the Laplace transformation, the transfer function of the drive system is obtained. These equations are used to analyze the time and frequency responses of the drive system to the electric excitation. It is known that electric excitation can cause forced responses of the drive system, the total dynamic responses are decided by three phase exciting voltages, exciting frequency and natural frequencies of the drive system, and the drive parameters have obvious influence on the time and frequency responses.

Computational Study to Understand the Cardiac Electromechanical Responses in LBBB and RBBB to the Application of CRT and LVAD

  • Heikhmakhtiar, Aulia Khamas;Lim, Ki Moo
    • Proceeding of EDISON Challenge
    • /
    • 2017.03a
    • /
    • pp.650-652
    • /
    • 2017
  • the aim of this study was to observe the combined effect of the CRT and LVAD on electromechanical cardiac behavior under LBBB and RBBB conditions computationally. We performed simulation by using advanced electromechanics model of failing ventricle combined with lumped model represents circulatory system, CRT and LVAD. We analyzed seven failing ventricle model including normal sinus rhythm, LBBB, LBBB coupled with CRT, LBBB coupled with CRT and LVAD, RBBB, RBBB coupled with CRT, and RBBB coupled with CRT and LVAD. We compared the effect from CRT and the effect from combined CRT and LVAD to both under LBBB and RBBB conditions. The results showed that the combined CRT and LVAD contributed a better hemodynamic compared to single CRT. This combined system synchronized the electrical activation greatly under LBBB and slightly under RBBB. It also shortened mechanical activation time which resulted short electromechanical delay. More importantly, the combined system produced better mechanical responses under both LBBB and RBBB conditions.

  • PDF

Double displacement coupled forced response for electromechanical integrated electrostatic harmonic drive

  • Xu, Lizhong;Zhu, Cuirong;Qin, Lei
    • Structural Engineering and Mechanics
    • /
    • v.29 no.5
    • /
    • pp.581-597
    • /
    • 2008
  • In this paper, the double displacement coupled statics and dynamics of the electromechanical integrated electrostatic harmonic drive are developed. The linearization of the nonlinear dynamic equations is completed. Based on natural frequency and mode function, the double displacement coupled forced response of the drive system to voltage excitation are obtained. Changes of the forced response along with the system parameters are investigated. The voltage excitation can cause the radial and tangent coupled forced responses of the flexible ring. The flexible ring radius, ring thickness and clearance between the ring and stator have obvious influences on the double displacement coupled forced responses.

Poisson Effect on Electromechanical Impedance of Unconstrained Piezoelectric Patch

  • Shin, Sung-Woo;Kwon, Oh-Heon
    • International Journal of Safety
    • /
    • v.8 no.2
    • /
    • pp.26-30
    • /
    • 2009
  • In this study, the Poisson effect on resonant frequency behaviors of the unconstrained piezoelectric patch is investigated. The electromechanical impedance models for the un-bonded patch are derived from the two existing bonded patch models and numerical analysis for a given piezoelectric material is performed. From the analysis, it is found that the Poisson effect is not important as long as the electromechanical impedance model is used to predict the locations of resonant frequencies. However, Poisson effect should be considered when predicting the location of the largest resonant frequency of the patch since the amplitude responses are different with the model used.

Dynamics of electric system for electromechanical integrated toroidal drive under mechanical disturbance

  • Hao, Xiuhong;Xu, Lizhong
    • Interaction and multiscale mechanics
    • /
    • v.2 no.2
    • /
    • pp.189-207
    • /
    • 2009
  • Dynamics of the electric system for the toroidal drive under mechanical disturbance is presented. Using the method of perturbation, free vibrations of the electric system under mechanical disturbance are studied. The forced responses of the electric system to voltage excitation under mechanical disturbance are also presented. We show that as the time grows, the resonance vibration caused by voltage excitation still exists and the vibrations caused by mechanical disturbance are enlarged. The coupled resonance vibration caused by mechanical disturbance and voltage excitation is discussed. The conditions of the occurrence of coupled resonance are studied.

Optimization of active vibration control for random intelligent truss structures under non-stationary random excitation

  • Gao, W.;Chen, J.J.;Hu, T.B.;Kessissoglou, N.J.;Randall, R.B.
    • Structural Engineering and Mechanics
    • /
    • v.18 no.2
    • /
    • pp.137-150
    • /
    • 2004
  • The optimization of active bars' placement and feedback gains of closed loop control system for random intelligent truss structures under non-stationary random excitation is presented. Firstly, the optimal mathematical model with the reliability constraints on the mean square value of structural dynamic displacement and stress response are built based on the maximization of dissipation energy due to control action. In which not only the randomness of the physics parameters of structural materials, geometric dimensions and structural damping are considered simultaneously, but also the applied force are considered as non-stationary random excitation. Then, the numerical characteristics of the stationary random responses of random intelligent structure are developed. Finally, the rationality and validity of the presented model are demonstrated by an engineering example and some useful conclusions are obtained.

Analysis of Ventricular Electromechanical Characteristics by Lesions in Sudden Myocardial Infraction: Computer Simulation Study (급성 심근경색 병변에 따른 심실의 전기 역학적 특성 분석: 컴퓨터 시뮬레이션 연구)

  • Baek, Dong Geun;Jeong, Da Un;Lim, Ki Moo
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.6
    • /
    • pp.313-320
    • /
    • 2017
  • Myocardial infarction is a disease caused by stenosis of the coronary arteries. The high risk of sudden cardiac death due to myocardial infarction has triggered related researches that have been actively studied so far. However, these studies focused on the clinical results, which are mainly based on observations of symptoms due to infarction through electrocardiograms. Therefore, in this study, we tried to analyze the behavior of heart according to the position and volume of infarction lesion through the computer simulation study using three dimensional ventricular models. In order to implement infarction, commercial software was used to simulate cell necrosis due to blockage of a specific coronary. In addition, the conduction block due to infarction was mimicked by reducing the electrical conduction in the infarcted area, which was 100 times less than the electrical conduction of the whole ventricular lattice implemented by the finite element analysis method. Thus, this study classified the infarcted cases into the upper, middle, lower, and apex according to lattice data of eight different infraction areas. In other words, we assumed that myocardial infarction would have inherent electro-dynamic characteristics depending on the location and extent, and analyzed the ventricular electromechanical responses for infarction lesions using a three dimensional cardiac physiome model. The results showed that the volume of infarction did not directly affect the cardiac responses, but the location of the infarction lesions could influence the ventricular pumping efficiency. These suggest that the occlusion of specific coronary arteries may have a fatal effect on the decline in ventricular performance. In conclusion, although location of myocardial infarction lesions is considered to be an important variable to be considered clinically rather than lesion size, quantitative predictions should be made more in the future considering physiological factors such as lesion location and direction of myocardial fiber at that location.

Development of the Control System for the Motor-Driven Electromechanical Total Artificial Hearta

  • Kim, Hee-Chan;Lee, Sang-Hun;Kim, Jong-Won-;Kim, Jin-Tae-;Min, Byoung-Goo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1988.10b
    • /
    • pp.858-863
    • /
    • 1988
  • A micro-processor based control system for a brushless DC motor used in the motor-driven electromechanical total artificial heart was developed. Functionally, the control system is composed of two parts. The first part is the velocity and position controller to assure that the motor follows a predetermined optimal velocity profile with minimal energy consumption, and to guarantee the full stroke length. This part also utilize the passive adaptive control method to be robust against the load disturbance, system parameter variation, and uncertainty which is the environment of artificial heart system. The pump output control is the second part, and this part provides the required responses of the artificial heart to the time-varying physiologic demands. The basic requirements of these responses are preload sensitivity, afterload insensitivity, and the balanced ventricular outputs. The performance and reliability of this control system was evaluated through a series of mock circulation tests and animal implantation, and the results are very encouraging.

  • PDF

Electromechanical coupled nonlinear dynamics of euler beam rails for electromagnetic railgun

  • Xu, Lizhong;Wu, Dewen
    • Smart Structures and Systems
    • /
    • v.19 no.2
    • /
    • pp.213-224
    • /
    • 2017
  • The electromagnetic field can cause an essential change of the dynamic behavior of the railgun. The evaluation of the dynamics performance of railgun is a mandatory task. Here, a nonlinear electromagnetic force equation of the railgun is given in which the clearance, the thickness and the width of the rail are considered. Based on it, the nonlinear electromechanical coupled dynamics equations of Euler beam rails for the railgun are proposed. Using the equations, the nonlinear free vibration frequency of the railgun is investigated and the effects of the system parameters on the frequency are analyzed. The nonlinear forced responses of the rail to the electromagnetic excitation are investigated as well. The results show that as the nonlinearity of the railgun system is considered, the vibration frequencies of the railgun system increase; as the current in the rail increases, the difference between the natural frequencies and the nonlinear vibration frequencies increases significantly; the nonlinearity of the railgun system is more obvious for smaller distance between the two rails, smaller rail thickness, and smaller stiffness of the elastic foundation; the unstable dynamics state of the rail system occurs when the armature runs to the exit of the railgun. The results are useful for design and application of the railgun system.