• Title/Summary/Keyword: electromagnetic simulation

Search Result 1,581, Processing Time 0.035 seconds

Stability Analysis of a Maglev Vehicle Utilizing Electromagnetic Suspension System (상전도 흡인식 자기부상열차의 주행 안정성 해석)

  • Han, Hyung-Suk;Kim, Sook-Hee;Yim, Bong-Hyuk;Hur, Young-Chul
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.3
    • /
    • pp.118-126
    • /
    • 2008
  • The levitation stability of a Maglev vehicle utilizing electromagnetic suspension is primarily influenced by the deformation, roughness, and vibration of the guideway. Optimum design for both the vehicle and the guideway is desirable in order to reduce guideway construction cost, while meeting requirements for stability and ride quality. This paper presents an analysis of the levitation stability of the UTM-01, an urban Maglev vehicle, using a numerical simulation. The ODYN/Maglev, a dynamics analysis program, is used to simulate dynamics to evaluate the stability. A running test of the UTM-01 is also carried out to verify the results of the simulation. Using the simulation results, the levitation stability of the UTM-01 can be numerically analyzed at a variety of vehicle speeds.

Multilayer Power Delivery Network Design for Reduction of EMI and SSN in High-Speed Microprocessor System

  • Park, Seong-Geun;Kim, Ji-Seong;Yook, Jong-Gwan;Park, Han-Kyu
    • Journal of electromagnetic engineering and science
    • /
    • v.2 no.2
    • /
    • pp.68-74
    • /
    • 2002
  • In this paper, a pre-layout design approach for high-speed microprocessor is proposed. For multilayer PCB stark up configuration as well as selection and placement of decoupling capacitors, an effective solution for reducing SSN and EMI is obtained by modeling and simulation of complete power distribution system. The system model includes VRM, decoupling capacitors, multiple power and ground planes for core voltage, vias, as well as microprocessor. Finally, the simulation results are verified by measurements data.

Analysis of Microwave-Induced Thermoacoustic Signal Generation Using Computer Simulation

  • Dewantari, Aulia;Jeon, Se-Yeon;Kim, Seok;Nikitin, Konstantin;Ka, Min-Ho
    • Journal of electromagnetic engineering and science
    • /
    • v.16 no.1
    • /
    • pp.1-6
    • /
    • 2016
  • Computer simulations were conducted to demonstrate the generation of microwave-induced thermoacoustic signal. The simulations began with modelling an object with a biological tissue characteristic and irradiating it with a microwave pulse. The time-varying heating function data at every particular point on the illuminated object were obtained from absorbed electric field data from the simulation result. The thermoacoustic signal received at a point transducer at a particular distance from the object was generated by applying heating function data to the thermoacoustic equation. These simulations can be used as a foundation for understanding how thermoacoustic signal is generated and can be applied as a basis for thermoacoustic imaging simulations and experiments in future research.

Design of Low Pass Filter to reduce EMI from 2.SG SDH system (2.5G SDH 전자파 감소용 저역통과필터 설계)

  • 이성원;김영범
    • Journal of the Korea Society for Simulation
    • /
    • v.10 no.4
    • /
    • pp.21-30
    • /
    • 2001
  • In this paper, EMI measurement, the STGU simulation being conducted, filter design, its characteristics, and its implementation to the PCB, and finally test results are discussed. When the low pass filter was implemented within the STGU, the power of EMI decreased more than 20dBm. Finally, when TE and MTIE, two important quality measure in synchronous reference clock, was assessed, ITU-T G813 requirement was satisfied. EMI(Electromagnetic Interface) is a measure of electomagnetic radiation from equipment in the range of 10KHz to 3GHz, and can cause unexpected reactions of electronics/electrical equipment. In this study, for safe and stable communication operation, a STGU (System Timing Generation Unit), which is a 2.5G SDH System and a major EMI source, was employed to simulate electromagnetic interface. Using Open-Site test, the power of fundamental frequency of EMI of interest and its harmonics were measured. Also, a low pass filter at cut-off frequency of 2GHz was specifically designed for this study to minimize the effect of EMI between electronic components.

  • PDF

Co-Simulation for Systematic and Statistical Correction of Multi-Digital-to-Analog-Convertor Systems

  • Park, Youngcheol;Yoon, Hoijin
    • Journal of electromagnetic engineering and science
    • /
    • v.17 no.1
    • /
    • pp.39-43
    • /
    • 2017
  • In this paper, a systematic and statistical calibration technique was implemented to calibrate a high-speed signal converting system containing multiple digital-to-analog converters (DACs). The systematic error (especially the imbalance between DACs) in the current combining network of the multi-DAC system was modeled and corrected by calculating the path coefficients for individual DACs with wideband reference signals. Furthermore, by applying a Kalman filter to suppress noise from quantization and clock jitter, accurate coefficients with minimum noise were identified. For correcting an arbitrary waveform generator with two DACs, a co-simulation platform was implemented to estimate the system degradation and its corrected performance. Simulation results showed that after correction with 4.8 Gbps QAM signal, the signal-to-noise-ratio improved by approximately 4.5 dB and the error-vector-magnitude improved from 4.1% to 1.12% over 0.96 GHz bandwidth.

A study of electromagnetic proportional flow control valve (비례전자식 유량제어벨브의 해석에 관한 연구)

  • Song, Chang-Seop;Yoon, Jang-Sang;Suh, Jong-Beom
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.10 no.1
    • /
    • pp.100-107
    • /
    • 1993
  • In this study, it is analyzed that an electromagnet whose generating force is proportional to constant current through coil in its coperating range. To find arelation between magnetic force and the structure in electromagnet, computer simulation method is used by permeance modeling method. When the electromagnet is applied to flow control valve, the relation between input current and flow is found. In order to get a reliability of computer simluation, the simulation results are compared to the experimental result. As the simulation is processed repeatedlyl. it is found that the gap size between plunger and guide steel and the length of tapered brass ring are important factors in electromaget.

  • PDF

Precision Validation of Electromagnetic Physics in Geant4 Simulation for Proton Therapy (양성자 치료 전산모사를 위한 Geant4 전자기 물리 모델 정확성 검증)

  • Park, So-Hyun;Rah, Jeong-Eun;Shin, Jung-Wook;Park, Sung-Yong;Yoon, Sei-Chul;Jung, Won-Gyun;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.225-234
    • /
    • 2009
  • Geant4 (GEometry ANd Tracking) provides various packages specialized in modeling electromagnetic interactions. The validation of Geant4 physics models is a significant issue for the applications of Geant4 based simulation in medical physics. The purpose of this study is to evaluate accuracy of Geant4 electromagnetic physics for proton therapy. The validation was performed both the Continuous slowing down approximation (CSDA) range and the stopping power. In each test, the reliability of the electromagnetic models in a selected group of materials was evaluated such as water, bone, adipose tissue and various atomic elements. Results of Geant4 simulation were compared with the National Institute of Standards and Technology (NIST) reference data. As results of comparison about water, bone and adipose tissue, average percent difference of CSDA range were presented 1.0%, 1.4% and 1.4%, respectively. Average percent difference of stopping power were presented 0.7%, 1.0% and 1.3%, respectively. The data were analyzed through the kolmogorov-smirnov Goodness-of-Fit statistical analysis test. All the results from electromagnetic models showed a good agreement with the reference data, where all the corresponding p-values are higher than the confidence level $\alpha=0.05$ set.

  • PDF

Analysis of Electromagnetic Wave Exposure Due to 6.78 MHz Wireless Power Transfer System (6.78 MHz 무선전력전송 시스템에 의한 전자파 노출량 분석)

  • Yoon, Seok;Jung, Hyeonjong;Lim, Yeongseog
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.12
    • /
    • pp.954-963
    • /
    • 2017
  • In this paper, we analyzed the electric/magnetic field distribution and SAR distribution in a human body due to the resonant-type wireless power transfer(WPT) system with an operating frequency of 6.78 MHz. To analyze the field distribution under the unperturbed condition, a prototype system was fabricated and the measured results were compared with the simulation results. For safety during measurement, the available power to the transmitter coil is limited to 1 W. To analyze the induced current density and SAR distribution, a simple human model consisting of three layers, skin, fat, and muscle, was used for the simulation. The electromagnetic wave exposure levels obtained through measurement and simulation were compared with the recommended levels by the ICNIRP.

Development of Massage Seat Actuator for Automobile using Electromagnetic Analysis and Simulation (전자기해석 및 시뮬레이션을 적용한 차량용 마사지 시트 액츄에이터 개발)

  • Chung, Myung-Jin
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.517-523
    • /
    • 2019
  • Recently, researches about automobile seat having function to support the comfort to driver and passenger during the driving are conducted in various fields including automobile seat having massage function. The effect of massage depends on the pattern of massage such as time, magnitude, and shape. In this paper, linear motor actuator, which is used as driving method in the automobile massage seat, and electromagnetic analysis method, which is used to improve the magnetic efficiency in the design of autuator, is proposed. Electromagnetic analysis using finite element method is conducted in the design of linear motor actuator. Input voltage shape for massage pattern is calculated by simulation using mathematical model of actuator. Performance test for massage pattern generation is conducted with automobile massage seat having developed actuator and controller. It is verified that developed actuator system is applicable in the automobile massage seat.

Effect of a Coil Shape on an Impulse Velocity of the Electromagnetic Welding (전자기 용접의 충돌 속도에 대한 코일 형상의 영향)

  • Park, H.;Lee, K.;Lee, J.;Lee, Y.;Kim, D.
    • Transactions of Materials Processing
    • /
    • v.28 no.3
    • /
    • pp.135-144
    • /
    • 2019
  • Electromagnetic impulse welding (EMIW) is a type of solid state welding using the Lorentz force generated by interaction between the magnetic field of the coil and the current induced in the workpiece. Although many experimental studies have been investigated on the expansion and compression welding of tube using the EMIW process, studies on the EMIW process of lap joint between flat sheets are uncommon. Since the magnetic field enveloped inside the tube can be controlled with ease, the electromagnetic technique has been widely used for tube welding. Conversely, it is difficult to control the magnetic field in the flat sheet welding so as to obtain the required welding velocity. The current study analyzed the effects of coil shape on the impulse velocity for suitable flat one-turn coil for the EMIW of the flat sheets. The finite element (FE) multi-physics simulation involving magnetic and structural field of EMIW were conducted with the commercial software LS-DYNA to evaluate the several shape variables, viz., influence of various widths, thicknesses, gaps and standoff distances of the flat one-turn coil on the impulse velocity. To obtain maximum impulse velocity, the flat one-turn coil was designed based on the FE simulation results. The experiments were performed using an aluminum alloy 1050 sheets of 1.0mm thickness using the designed flat one-turn coil. Through the microscopic interfacial analysis of the welded specimens, the interfacial connectivity was observed to have no defects. In addition, the single lap joint tests were performed to evaluate the welding strength, and a fracture occurred in the base material. As a result, a flat one-turn coil was successfully designed to guarantee welding with bond strength equal to or greater than the base material strength.