• 제목/요약/키워드: electromagnetic field on the human body

검색결과 36건 처리시간 0.027초

Measurement and Modeling of Personal Exposure to the Electric and Magnetic Fields in the Vicinity of High Voltage Power Lines

  • Tourab, Wafa;Babouri, Abdesselam
    • Safety and Health at Work
    • /
    • 제7권2호
    • /
    • pp.102-110
    • /
    • 2016
  • Background: This work presents an experimental and modeling study of the electromagnetic environment in the vicinity of a high voltage substation located in eastern Algeria (Annaba city) specified with a very high population density. The effects of electromagnetic fields emanating from the coupled multi-lines high voltage power systems (MLHV) on the health of the workers and people living in proximity of substations has been analyzed. Methods: Experimental Measurements for the Multi-lines power system proposed have been conducted in the free space under the high voltage lines. Field's intensities were measured using a referenced and calibrated electromagnetic field meter PMM8053B for the levels 0 m, 1 m, 1.5 m and 1.8 m witch present the sensitive's parts as organs and major functions (head, heart, pelvis and feet) of the human body. Results: The measurement results were validated by numerical simulation using the finite element method and these results are compared with the limit values of the international standards. Conclusion: We project to set own national standards for exposure to electromagnetic fields, in order to achieve a regional database that will be at the disposal of partners concerned to ensure safety of people and mainly workers inside high voltage electrical substations.

The Effect of Sub-chronic Whole-Body Exposure to a 1,950 MHz Electromagnetic Field on the Hippocampus in the Mouse Brain

  • Son, Yeonghoon;Jeong, Ye Ji;Kwon, Jong Hwa;Choi, Hyung-Do;Pack, Jeong-Ki;Kim, Nam;Lee, Yun-Sil;Lee, Hae-June
    • Journal of electromagnetic engineering and science
    • /
    • 제15권3호
    • /
    • pp.151-157
    • /
    • 2015
  • The increasing use of mobile phones has raised public concern about the possible biological effects of radiofrequency electromagnetic field (RF-EMF) exposure on the human brain. To investigate the potential effect of RF-EMF exposure on the brain, we examined the behaviors and hippocampal morphology of C57BL/6 mice after sub-chronic exposure to RF-EMFs with a relatively high SAR level (5.0 W/kg). We applied a 2-hour daily exposure of WCDMA 1,950 MHz using a reverberation chamber that was designed for whole-body exposure for 60 days. In the behavioral tests, RF-EMF did not alter the physical activity or long-term memory of mice. Moreover, no alteration was found in the neuronal and glial cells in the hippocampus by RF-EMFs. In this study, we showed that sub-chronic whole body RF exposure did not produce memory impairment and hippocampal morphological alteration in C57BL/6 mice.

인체 부착형 UWB MIMO 안테나 설계 (Design of UWB MIMO Antenna for On-Body Application)

  • 주은만;권결;전재성;김선우;최재훈
    • 한국전자파학회논문지
    • /
    • 제25권2호
    • /
    • pp.137-148
    • /
    • 2014
  • 본 논문에서는 인체 부착형 Ultra-Wideband(UWB) Multiple-Input Multiple-Output(MIMO) 안테나를 제안하고, 인체의 영향을 고려한 안테나 성능과 인체에 미칠 수 있는 영향에 대한 분석을 하였다. 제안된 안테나는 사각 모노폴 형태의 두 안테나와 격리도 특성을 개선하기 위하여 안테나 사이에 위치한 plunger형 isolator로 구성되어 있다. 안테나의 근거리장에 인체가 존재할 때, 인체가 안테나에 미치는 영향을 분석하기 위하여 시뮬레이션과 측정을 수행하였다. 측정 결과, Specific Absorption Rate(SAR) 값은 공급전력 0.5 mW에서 안테나 1, 2 각각 0.132, 0.08 W/Kg으로 1 g 평균 전자파 흡수율을 1.6 W/kg으로 제한한 FCC 지침을 초과하지 않음을 알 수 있다.

6.78 MHz 무선전력전송 시스템에 의한 전자파 노출량 분석 (Analysis of Electromagnetic Wave Exposure Due to 6.78 MHz Wireless Power Transfer System)

  • 윤석;정현종;임영석
    • 한국전자파학회논문지
    • /
    • 제28권12호
    • /
    • pp.954-963
    • /
    • 2017
  • 본 연구에서는 공진형 무선전력전송시스템에 의해 발생되는 자기장과 전기장 강도 및 이에 의한 인체 내부 전자파 비흡수율(Specific Absorption Rate: SAR) 분포를 분석하였다. 연구에서 사용된 동작주파수는 ISM 대역에 해당하는 6.78 MHz이다. 실제 시스템을 제작하고, 시스템의 송신측에 공급되는 가용 전력을 1 W로 제한하여 전기장 및 자기장 분포를 측정하고, 동일한 규격으로 시뮬레이션한 결과와 비교하였다. 피부, 지방, 근육의 순으로 조직층이 구성된 단순인체모델을 이용하여, WPT 시스템으로부터의 거리에 따른 인체 내부의 유도 전류밀도와 SAR 분포를 구하였다. 측정과 시뮬레이션을 통해 얻어진 전자파 노출 정도를 ICNIRP(International Commission on Non-Ionizing Radiation Protection)의 국제 권고기준과 비교하여 분석하였다.

Proteomic analysis of murine peritoneal macrophages after in vitro exposure to static magnetic field

  • Soon, Eun-Jae;Woong, Ko-Dae;Geun, Kwak-Young
    • 한국응용약물학회:학술대회논문집
    • /
    • 한국응용약물학회 2003년도 Annual Meeting of KSAP : International Symposium on Pharmaceutical and Biomedical Sciences on Obesity
    • /
    • pp.113-113
    • /
    • 2003
  • A number of studies have demonstrated recently nonthermal interactions of extremely low frequency electromagnetic fields with cellular systems, such as the cells of the immune system. Particular concern came from epidemiological findings, which correlated environmental exposure of human body to weak electromagnetic fields with an elevated risk for developing certain type of leukemias and cancers. Several home/environmental sources generating extremely low frequency electromagnetic fields, such as 50 - 60 Hz high-voltage transmission lines, video display terminals, electric blankets, clinical nuclear magnetic resonance imaging procedures, etc., may interact with the human body. In this study we examined the effects of static magnetic fields (SMF) on the phagocytosis of the murine peritoneal macrophages (C57BL/6). The cells were exposed in vitro for 24 h at 37$^{\circ}C$ to 400 G SMF. The phagocytic activity of peritoneal macrophages was determined with a luminometer. Exposure to the SMF decreased phagocytic activity of murine peritoneal macrophages. In order to provide a more exact mechanism of the phenomenon, we analyzed peritoneal macrophages for alteration in their proteomes. The expression levels of these 5 proteins were increased in the SMF. In total 5 proteins which were differentially expressed in the SMF compared with control group were identified. The expression levels of these 5 proteins were increased in the SMF.

  • PDF

침과 자석의 전자기적 특성을 이용한 세포막 전해질 흐름 연구 (Cellmembrane Electrolyte Flow Research Using Electromagnetic Characteristics of Needle and Magnet)

  • 이영주;박민용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.3-6
    • /
    • 2002
  • In this paper, the electrolyte flow treatment is suggested using together with needle and magnet. On account of Lorentz force law, we can not only induce the circulation of body fluids at specific hurt but also apply on the treatment of cell membrane voltage control controlling the electrolyte flow. If electric field is added to human body fluid, electrolyte and then magnetic field is taken by magnet, we can induce local region flow through needle, global region flow with artificial electrical field and magnetic field. Electrolyte flow is excellent treatment in clinical treatment.

  • PDF

Development of Korean Male Body Model for Computational Dosimetry

  • Lee, Ae-Kyoung;Choi, Woo-Young;Chung, Min-Suk;Choi, Hyung-Do;Choi, Jae-Ick
    • ETRI Journal
    • /
    • 제28권1호
    • /
    • pp.107-110
    • /
    • 2006
  • The dimensions of the human body vary by age, sex, and race. The internal structure and outer dimensions of a body exposed to an electromagnetic field is important for accurate dosimetry. The average physical size of Korean adult males between the ages 18 to 24 was investigated, and a male volunteer was selected whose physical condition is within the physical standards, ${\pm}5%$. Magnetic resonance images and partially computerized tomography images of the volunteer were acquired. The intervals between the transverse images were 1 mm for the head and 3 mm for the rest of the body. About 30 different tissues were manually classified by an anatomist on the raw images, and the segmented images were implemented in the form of a text file appropriate for numerical formulation.

  • PDF

인체 상 위치를 고려한 다양한 WBAN 안테나 설계 (Design of Various WBAN Antennas Considering for the Location on a Human Body)

  • 탁진필;최재훈
    • 한국전자파학회논문지
    • /
    • 제25권11호
    • /
    • pp.1095-1103
    • /
    • 2014
  • WBAN은 다양한 응용 가능성 때문에 최근 들어 많은 관심을 받고 있다. 본 논문에서는 기기의 위치에 따른 WBAN 통신 환경에 적합한 몇 가지 안테나와 모의 인체 제작에 대하여 소개하고자 한다. WBAN 시스템은 인체 내부 및 인체 표면에서 동작하므로 고유전율 및 고도전율을 갖는 인체 매질에 대한 영향을 고려해야 하며, 특히 안테나는 근역장 매질 특성에 따라 안테나의 방사 특성 및 반사 손실 특성이 변하게 되므로, 이를 고려한 안테나 설계가 요구된다. 또한, 안테나의 인체 영향을 고려하기 위해 모의 인체를 이용해 안테나를 설계하고 측정하였다. 서론에서는 WBAN 통신 채널의 분류를 소개하고, 각각의 통신 채널에 적합한 안테나의 특성에 대해 간단히 언급하였다. 제안된 몇 가지 안테나 사례 및 모의 인체 구현에 대하여 논의하였다. 결론에서는 안테나 설계 시 고려해야 할 사항과 향후 연구에 대해 언급하였다.

전원설비에 의한 공간조건별 전위분포 사례 연구 (Case Studies for Potential Distribution due to Power Source by Environmental Condition)

  • 정진수;정종욱;김선구
    • 조명전기설비학회논문지
    • /
    • 제25권1호
    • /
    • pp.50-58
    • /
    • 2011
  • In this paper, potential distribution analysis through the six kinds of case studies examined in the environmental conditions change within a limited space, by the power supply system installed. To interpret the potential distribution using electromagnetic field analysis program and the parameters were state of the ground, the outer wall of the configuration state and the presence of human potential distribution was simulated. Potential distribution analysis, the size of nominal voltage, depending on the impedance of human body to be determined on the impact of surprise decision, but if equipped with appropriate protective equipment can be protected from lightning have been confirmed.

765 kV 초고압 송전선 주변의 인체 유도전류 계산 (Calculation of Induced Current in the Human Body around 765 kV Transmission Lines)

  • 명성호;이재복;허창수
    • 한국전자파학회논문지
    • /
    • 제9권6호
    • /
    • pp.802-812
    • /
    • 1998
  • 고전압 발/ 변전소의 근무자나 송전선 작업자 및 주변거주자가 전계 노출에 안전해야 함은 중요한 일이다. 본 논문에서는 복잡하고 계산시간이 많이 소요되는 인체의 3차원 유도전류를 계산하기 위해 전압원(송전선 로)의 효과적인 모델링 기법을 사용하여 전압원과 피유도체를 분리하지 않고 직접 3차원 정전용량을 구함으 로써 불평등 전계하의 임의의 3차원 공간상에서도 인체에 미치는 유도전류 해석이 가능한 장접을 갖도록 하 였다. 사례연구로 본 연구에서 제안한 알고리즘을 765 kV급 초고압 송전선로에 적용하여 인체 유도 안전 성을 평가한 결과 765 kV 송전선에서 인체의 단락전류는 인체의 위치에 따라 0.3 mA에서 6.8 mA로 분포 되었다. 특히, 송전선로에서 활선 작업시 단락전류 $I_{sc}$의 크기는 ANSI 허용기준인 5 mA를 념을 수 있어 활 선 작업시 작업자의 전계의 방호 대책을 위해서는 도전물질로 구성된 보호복이 필요함을 알 수 있었다.

  • PDF