• Title/Summary/Keyword: electromagnetic damper

Search Result 54, Processing Time 0.033 seconds

Controllable Squeeze Film Damper Using an Electromagnet (전자석을 이용한 가제어형 스퀴즈필름댐퍼)

  • 안영공;하종룡;양보석;김동조
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.6
    • /
    • pp.484-489
    • /
    • 2003
  • The paper represents stability of a rotor system with the squeeze film damper (SFD) using an electromagnet. The electromagnet is installed in the inner damper of the SFD. The proposed SFD has basically the property of a conventional SFD and variable damping property according to variation of the applied electric current. Therefore, when the applied current Is controlled, the whirling vibration of the rotor system can be effectively reduced in a wide operational speed range. In the present work, the performance of the SFD was experimentally investigated according to changing the magnetic field strength. As the applied current increased, damping ratios increased, while whirling amplitudes greatly reduced.

Performance verification of Smart Complex Damping System for Suppressing Vibration of Stay Cable (케이블 진동 저감을 위한 스마트 복합 감쇠 시스템의 성능평가)

  • Park, Chul-Min;Jung, Hyung-Jo;Ko, Man-Gi;Lee, In-Won
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2006.03a
    • /
    • pp.453-460
    • /
    • 2006
  • Stay cables, such as used in cable-stayed bridges, are prone to vibration due to their low inherent damping characteristics. Recently some studies have shown that active and semiactive control system using MR damper can potentially achieve both higher performance levels than passive control system and adaptability with few of the detractions. However, a control system including a power supply, controller, and sensors is required to maximize the performance of the MR damper and this complicated control system is not effective to most of large civil structures. This paper proposes a smart complex damping system which consists of toggle system and MR dampers by introducing electromagnetic induction(EMI) system as an external power source to MR damper. The performance of the proposed damping device has been compared with that of the passive-type control systems employing a MR damper, a linear viscous damper, and EMI system.

  • PDF

High Stability and High Efficiency Power Amplifier with Switchable Damper for Plasma Applications (플라즈마 응용을 위한 선택적 감쇠기를 사용한 고안정 고효율 전력증폭기)

  • Kim, Ji-Yeon;Lee, Dong-Heon;Chun, Sang-Hyun;Yoo, Ho-Joon;Kim, Jong-Heon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.1
    • /
    • pp.1-11
    • /
    • 2009
  • In this paper, a new 1 kW power amplifier with high efficiency and high stability in a RF generator is designed and fabricated for plasma applications. The efficiency of power amplifier is improved by using class-E amplifier that consists of one push-pull MOSFET and high current drive IC instead of class-C amplifier composed of several single ended MOSFET. Switchable damper that allows selecting three different modes of amplifiers for considering efficiency and stability is added into the amplifier for plasma applications. Stable region of an early electronic discharge section is extended to VSWR of 4.5:1 compared to conventional VSWR of 3.8:1 through using switchable damper. The dimension of the amplifier is also reduced to 30 % of conventional amplifier. The 80 % efficiency of power amplifier with switchable damper is obtained the output power of 1 kW in operating frequency of 13.56 MHz. In comparison of conventional power amplifier for plasma applications, 13 % efficiency is improved.

The tuned mass-damper-inerter for harmonic vibrations suppression, attached mass reduction, and energy harvesting

  • Marian, Laurentiu;Giaralis, Agathoklis
    • Smart Structures and Systems
    • /
    • v.19 no.6
    • /
    • pp.665-678
    • /
    • 2017
  • In this paper the tuned mass-damper-inerter (TMDI) is considered for passive vibration control and energy harvesting in harmonically excited structures. The TMDI couples the classical tuned mass-damper (TMD) with a grounded inerter: a two-terminal linear device resisting the relative acceleration of its terminals by a constant of proportionality termed inertance. In this manner, the TMD is endowed with additional inertia, beyond the one offered by the attached mass, without any substantial increase to the overall weight. Closed-form analytical expressions for optimal TMDI parameters, stiffness and damping, given attached mass and inertance are derived by application of Den Hartog's tuning approach to suppress the response amplitude of force and base-acceleration excited single-degree-of-freedom structures. It is analytically shown that the TMDI is more effective from a same mass/weight TMD to suppress vibrations close to the natural frequency of the uncontrolled structure, while it is more robust to detuning effects. Moreover, it is shown that the mass amplification effect of the inerter achieves significant weight reduction for a target/predefined level of vibration suppression in a performance-based oriented design approach compared to the classical TMD. Lastly, the potential of using the TMDI for energy harvesting is explored by substituting the dissipative damper with an electromagnetic motor and assuming that the inertance can vary through the use of a flywheel-based inerter device. It is analytically shown that by reducing the inertance, treated as a mass/inertia-related design parameter not considered in conventional TMD-based energy harvesters, the available power for electric generation increases for fixed attached mass/weight, electromechanical damping, and stiffness properties.

Performance Verification of Smart Passive Damping System using MR damper (자기유변유체 감쇠기에 기반한 스마트 수동 감쇠 시스템의 성능 평가)

  • Cho, Sang-Won;Jang, Ji-Eun;Yoon, Woo-Hyun;Lee, In-Won
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2005.03a
    • /
    • pp.505-512
    • /
    • 2005
  • MR damper is one of the most promising control devices for civil engineering applications to earthquake hazard mitigation. However, a control system including a power supply, controller, and sensors is required to maximize the performance of the MR damper and this complicated control system is not effective to most of large civil structures. This paper proposes and experimentally verified a smart passive damping system using MR(Magnetorheological) dampers by introducing electromagnetic induction(EMI) system as an external power source to MR damper. It is easy to build up and maintain EMI system, because it does not require any control system such as a power supply, controller, and sensors. Numerical simulations using experimental model of EMI system are carried to verify the effectiveness of the proposed EMI system. The performances of smart passive damping system are compared with those of passive and semiactive MR dampers.

  • PDF

Seismic Performance Improvement of Base Isolated Buildings using Smart Passive Control System (스마트 수동 제어 시스템을 이용한 면진 건물의 내진 성능 개선)

  • Jung, Hyung-Jo;Jung, Chan-Kuk;Choi, Kang-Min;Lee, In-Won
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.6 s.52
    • /
    • pp.37-46
    • /
    • 2006
  • In this study, the efficacy of the newly developed smart passive control system to improve seismic performance of base isolated building structures is numerically verified. The smart passive control system consists of a magnetorheological (MR) damper and an electromagnetic induction (EMI) part. The damping characteristics of an MR damper can be controlled by the current generated in an EMI part according to the Faraday's law of electromagnetic induction. An EMI part consisting of a permanent magnet and a solenoid coil could substitute a control system including sensors, a controller and an external power supply in a conventional smart control system. The benchmark control problem for a base isolated building presented by the american society of civil engineers is considered for numerical simulation. The control performance of the smart passive control system is compared to that of the conventional smart control system using MR dampers. It is demonstrated from the numerical simulation results that the smart passive control system is useful to improve the seismic performance of base isolated buildings.

Vibration Control of Stay Cable Using Smart Passive Damping System (스마트 수동 감쇠 시스템을 이용한 사장 케이블의 진동 제어)

  • Jung Hyung-Jo;Cho Sang-Won;Jang Ji-Eun;Lee In-Won
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2005.04a
    • /
    • pp.497-504
    • /
    • 2005
  • Stay cables, such as are used in cable-stayed bridges, are prone to vibration due to their low inherent damping characteristics. Several methods have been proposed and implemented to mitigate this problem, though each has its limitations. Recently some studies have shown that active and semiactive control system using MR (Magnetorheological) damper can potentially achieve both higher performance levels than passive control system and adaptability with few of the detractions. However, a control system including a power supply, controller, and sensors is required to maximize the performance of the MR damper and this complicated control system is not effective to most of large civil structures. This paper proposes a smart passive damping system using MR dampers by introducing electromagnetic induction (EMI) system as an external power source to MR damper and verified the performance of smart passive damping system for mitigating the vibration of stay cables. The performances of smart passive damping system are compared with those of linear viscous damper and passive-mode MR damper.

  • PDF

Real-time model updating for magnetorheological damper identification: an experimental study

  • Song, Wei;Hayati, Saeid;Zhou, Shanglian
    • Smart Structures and Systems
    • /
    • v.20 no.5
    • /
    • pp.619-636
    • /
    • 2017
  • Magnetorheological (MR) damper is a type of controllable device widely used in vibration mitigation. This device is highly nonlinear, and exhibits strongly hysteretic behavior that is dependent on both the motion imposed on the device and the strength of the surrounding electromagnetic field. An accurate model for understanding and predicting the nonlinear damping force of the MR damper is crucial for its control applications. The MR damper models are often identified off-line by conducting regression analysis using data collected under constant voltage. In this study, a MR damper model is integrated with a model for the power supply unit (PSU) to consider the dynamic behavior of the PSU, and then a real-time nonlinear model updating technique is proposed to accurately identify this integrated MR damper model with the efficiency that cannot be offered by off-line methods. The unscented Kalman filter is implemented as the updating algorithm on a cyber-physical model updating platform. Using this platform, the experimental study is conducted to identify MR damper models in real-time, under in-service conditions with time-varying current levels. For comparison purposes, both off-line and real-time updating methods are applied in the experimental study. The results demonstrate that all the updated models can provide good identification accuracy, but the error comparison shows the real-time updated models yield smaller relative errors than the off-line updated model. In addition, the real-time state estimates obtained during the model updating can be used as feedback for potential nonlinear control design for MR dampers.

Electromagnetic Characteristics Analysis of Thrust Magnetic Bearing/Damper (축방향 자기 베어링/댐퍼의 전자기적 특성해석)

  • Jang, Seok-Myeong;Lee, Un-Ho;Choi, Jang-Young
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.2014-2015
    • /
    • 2007
  • This paper deals with design and analysis of thrust magnetic bearing. Using the solutions obtained from equivalent magnetic circuit, we predict the electromagnetic characteristics such as thrust, time constant and power loss according to design parameters. And then, using non-linear finite element analysis, a detailed design is performed considering saturation in order to meet requirements.

  • PDF