• 제목/요약/키워드: electromagnetic actuator

검색결과 226건 처리시간 0.036초

약물 전달용 유연한 플랩 밸브의 제작 (Fabrication of a Flexible Flap Valve for Drug Delivery Systems)

  • 임인호;이기정;심우영;양상식
    • 전기학회논문지
    • /
    • 제58권4호
    • /
    • pp.801-805
    • /
    • 2009
  • This paper reports on a flexible flap valve actuated by electromagnetic force under a constant pressure source. The flexible flap valve consists of the three main components: a flexible flap with a steel disk embedded in PDMS, an electromagnetic actuator and two glass plates with inlet and outlet. The flap valve is fabricated by SU-8 mold process, the EDM process and oxygen plasma treatment. The dimension of an assembled flap valve is $12[mm]{\times}20[mm]{\times}28[mm]$. The stroke volume of the flap valve is measured for various pressures. And the time of the applied input voltage is varied to change the open time of the valve. When the input voltage of 30[V] is applied for 0.25[s], the minimum stroke volume of the flap valve is $40[{\mu}L]$ at 70 [kPa].

자기시스템의 전자력 밀도 해석 (Electromagnetic Force Density Analysis of Magnetic System)

  • 이세희;최명준;김창욱;박일한
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 A
    • /
    • pp.201-203
    • /
    • 1997
  • As electromagnetic systems have the complexity and high performance, they should be designed to take into account the vibration, noise and strain of mechanical aspect as well as electrical problems. Until now, mechanical approaches have been tried to analyze the subject, but it is difficult to figure out the matter in mechanical consideration. Because they are mainly related to electromagnetic phenomena. This paper deals with the theories and numerical formulations of magnetic force density. Several methods are applied to an actuator and DC machine model to calculate magnetic force density. These results are compared with the total force obtained by maxwell stress tensor and virtual work principle.

  • PDF

약물 전달용 전자력 마이크로 밸브의 설계 및 제작 (Design, Fabrication of Electromagnetic Microvalve for Drug Delivery Systems)

  • 임인호;이기정;윤현중;심우영;양상식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1526-1527
    • /
    • 2007
  • This paper presents the design, fabrication and experimental results of an electromagnetic microvalve for drug delivery systems. The microvalve consists of two silicon substrates with a silicone rubber diaphragm and a flow channel, a PDMS layer, and an electromagnetic actuator. Each substrate is fabricated by using the silicon wet etch, SU-8 mold process and $O_2$ plasma bonding.

  • PDF

유전체 장벽 방전 플라즈마의 전자파 산란 특성 분석 (Analysis of Electromagnetic Wave Scattering Characteristics of Dielectric Barrier Discharge Plasma)

  • 이수민;오일영;홍용준;육종관
    • 한국전자파학회논문지
    • /
    • 제24권3호
    • /
    • pp.324-330
    • /
    • 2013
  • 본 논문은 대기압 환경에서 발생하는 유전체 장벽 방전(dielectric barrier discharge: DBD) 플라즈마의 전자파 산란 특성을 측정하였다. 본 논문에서는 기본적인 DBD 플라즈마 발생기 구조를 병렬로 연결하여 넓은 면적의 플라즈마 발생기를 제작하였고, 14 kV, 4 kHz의 고전압 발생장치를 이용해 플라즈마가 발생하는 것을 확인하였다. 두 개의 혼 안테나와 벡터 네트워크 분석기를 이용해 S-parameter의 비교를 통해 전자파 산란 특성을 측정하였다. 전방 산란의 경우 제작된 플라즈마 발생기의 구조적 특성으로 인해 안테나의 편파에 따라 다른 결과 값을 얻었다. 편파가 수평일 때 최대 2 dB의 산란파 감쇠 특성을 확인할 수 있었다. 또한, 편파가 수평일 경우, 플라즈마 발생기 뒤에 PEC를 설치한 후 후방 산란 특성을 측정하였다. 그 결과, 5 GHz에서 안테나 관찰 각도가 $40^{\circ}C$, $60^{\circ}C$일 때 최대 2 dB 산란파 감쇠 특성을 얻었다.

박막 재료 시험기 개발 및 응용 (Development and Applications of Material Testers for the Thin Films)

  • 안현균;이학주;오충석
    • 한국정밀공학회지
    • /
    • 제23권3호
    • /
    • pp.163-170
    • /
    • 2006
  • Thin films play an important role in many technological applications including microelectronic devices, magnetic storage media, MEMS and surface coatings. It is well known that a thin film's material properties can be very different front the corresponding bulk properties and thus there has been a strong need for the development of a miniature tester to measure the mechanical properties of a thin film. Two testers are designed and set up in small size of 62 mm width, 20 mm depth and 90-120 mm height to fit in a chamber of scanning electron microscope (SEM). One tester has a homemade 0.2 N load cell and a low-priced electromagnetic actuator. The other has a commercial 5 N load cell, a $52{\mu}m$ piezoelectric actuator and some novel grips. Two types of 3.5 microns thick polysilicon specimen are tested to prove the testers' applicability. The strain is measured by the two ways. Firstly, it is measured by an ISDG system in the atmosphere far the reference. Secondly, the same test is repeated in a SEM chamber to monitor the strain as an in-situ experiment. The strain is evaluated by observing the gap change between two markers.

전자기력 조합에 기초한 평면 구동기를 이용한 자기 부상 방식 초정밀 스테이지 (Precision Stage Using A Novel Contact-Free Planar Actuator Based on Combination of Electromagnetic forces)

  • 정광석;백윤수
    • 대한기계학회논문집A
    • /
    • 제25권11호
    • /
    • pp.1863-1872
    • /
    • 2001
  • In this Paper, we suggest the precision stage using a novel non-contact planar actuator that utilizes an interaction between an array type of air-core solenoids and permanent magnets. The former with axes arranged in the mutually orthogonal direction is fixed on the stator and the latter with the same polar direction is attached below the stage. The promising magnetic structure has little uncertainty such as hysteresis loss caused by ferromagnetic material, then it is simple to quantify the magnetic phenomenon. And all the magnetic forces are transmitted through narrow air-gap between the coil and the permanent magnet, therefore the structure can be highly compacted. Furthermore, the stage or plate can be perfectly isolated from the stator without any wire connection, leading to diminish the generating possibility of wear particles due to mechanical contact. Then. it is estimated that the proposed operating principle is very suitable for work requiring high accuracy and cleanness. or general-purpose nano stage. The main issues rebated to the plate driving are discussed here.

Design and Analysis Method for A DC Magnetic Contactor with a Permanent Magnet

  • Kim, So-Hyun;Park, Hyeon-Jeong;Ro, Jong-Suk;Jung, Hyun-Kyo
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권4호
    • /
    • pp.481-486
    • /
    • 2014
  • The demand for a DC power distributed system is increasing as renewable energy sources and DC electrical load are proliferating. For the automation of a power system, a magnetic contactor for the DC power system is required. The conventional magnetic contactors are mostly equipped with a solenoid magnetic actuator. However, the conventional magnetic contactor has problems with continuous power consumption, and heat generation. To address these problems, a permanent magnet type DC magnetic contactor is proposed in this paper.

전자기 전달관계를 이용한 원통형 직선 왕복구동 액추에이터의 전자기 특성 해석 및 실험 (Electromagnetic Field Analysis and Measurements of Cylindrical Linear Oscillatory Actuator using Transfer Relations Theorem)

  • 장석명;김현규;최장영;이성호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.89-91
    • /
    • 2008
  • This paper deals with the thrust calculations and the measurements of a cylindrical Linear Oscillatory Actuator (LOA) sing Transfer Relations Theorem (TRT), namely, Melcher's methodology. Using transfer relations derived in terms of a magnetic vector potential and a two-dimensional (2-d) cylindrical coordinate system, this paper derives analytical solutions for the magnetic vector potential, magnetic fields due to Permanent Magnets (PMs) and stator winding currents and the thrust. The analytical results are validated by non-linear Finite Element (FE) analyses. In particular, test results such as thrust and back-emf measurements are given to confirm the analysis.

  • PDF

PWM 제어용 고전압 릴레이의 테스트베드 설계 (Testbed Design of PWM Controlled High Voltage Relay)

  • 김진광
    • 한국산업융합학회 논문집
    • /
    • 제20권5호
    • /
    • pp.419-424
    • /
    • 2017
  • The purpose of this study is to develop a virtual testbed capable of predicting the functional performance of a linear electromagnetic actuator for a high voltage relay in order to reduce its development costs and time. The virtual testbed is defined by a multiphysics coupling approach in order to consider the complex interactions of multi-domains such as the solenoid model of electromagnets, the mass-spring-damper model of mechanical systems, the electric circuit model for an external control unit, and the thermal model for predicting temperature variations. The performances of the existing high voltage relay were estimated by the virtual testbed, and then the effectiveness and validation of the proposed testbed were discussed in comparison with the experimental test results. This study showed that the virtual testbed can be applied in design, optimization, and investigation of high voltage relays.

개별 동점 속도제어를 이용한 다점 지지계의 능동진동제어 (Active vibration isolation of a multiple mount system using decentralised collocated velocity feedback control)

  • 김상명
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.291-298
    • /
    • 2000
  • This paper describes a theoretical and experimental investigation into an active vibration isolation system in which four electromagnetic actuators are installed in parallel with each of four passive mounts placed between a piece of equipment and a vibrating base structure. Decentralised velocity feedback control is employed, where each actuator is operated independently by feeding back the absolute equipment velocity at the same location. Although one end of each actuator acts at the sensor positions on the equipment, the control system is not collocated because of the reactive forces acting on the flexible base structure, whose dynamics are strongly coupled with the mounted equipment. Isolation of low frequency vibration is considered where the equipment can be modelled as a rigid body and the mounts as lumped parameter springs and dampers. Control mechanisms are discussed, and some experimental and simulation results are reported.

  • PDF