• Title/Summary/Keyword: electrode wear

Search Result 86, Processing Time 0.032 seconds

Design of Compression Pants for Wireless sEMG Monitoring using e-textile (E-textile을 이용한 무선 sEMG 모니터링 컴프레션 바지 설계)

  • Heejae Jin;Hyojeong Lee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.48 no.1
    • /
    • pp.94-107
    • /
    • 2024
  • This study developed compression pants with excellent wearability and signal quality by approaching the design of wireless sEMG monitoring pants from the perspective of technical design, including the evaluation of wearability and the stable wireless transmission of signals through electrode and circuit design, and using e-textiles. An electrode, sewn with silver thread and a circuit stitched in a zigzag pattern using stainless steel wire, were applied. Additionally, polyurethane sealing tape was used to enhance adherence to the skin and reduce electrical resistance. Conductive snaps completed the design, allowing attachment and detachment to the bio-signal acquisition mainboard. Through the subjects' evaluation, it was determined that the final pants were applied with a pattern reduction rate of 25% to provide superior comfort according to different body parts while also minimizing skin irritation around the thigh circuit. The final pants for wireless sEMG monitoring, which demonstrated stable transmission of wireless measurements, was positively evaluated in terms of cognitive acceptability. This study is significant in that it achieved an optimal design by considering both technical aspects and the electrical characteristics of bio-signal monitoring garments, as well as the wearer's perception when designing smart wear.

A study for its Characteristics with Electric Variation in an Electrical Discharge Machining (방전가공에서 전기적 변화가 갖는 방전 특성에 관한 연구)

  • 신근하
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1996.03a
    • /
    • pp.132-136
    • /
    • 1996
  • A Study is a experiment which is figure out to aptimum discharge cutting condition of the surfaceroughness, electric discharging speed and electro wear ratio with Ton Toff and V(voltage) as an input condition according to the current(Ip) in an electric spark machine ; 1)Electrode is utilized Cu(coper) and Graphite. 2)Work piece is used the material of carbon steel. The condition of experiment is; 1)Current is varied 0.7(A) to 50(A). 2)Pulse time(Ton) is varied 3($\mu$s) to 240($\mu$s) and also Toff is varied 7($\mu$s) to 20($\mu$s). 3)The time of electric discharging to work piece in each time is 30(min) to 60(min) 4)After the upper side of work piece was measured in radius (5${\mu}{\textrm}{m}$) of syulus analyzed the surface roughness to made the table and graph of Rmax by yielding data. 5)Electro wear ratio is; \circled1Coper was measured cx-machining and post machining but the electronic baiance. \circled2The ex-machining of graphite measured by it, the post-machining was found the data from volume specific gravity and analyzed to made its table and graph on ground the data 6)In order to keep the accuracy of voltage affected to the work piece was equipped with the A.V.R(Automatic Voltage Regulator). 7)The memory scope was sticked to the electric spark machine. 8)In order to preserve the precision of current, to get rid of the noise occured by internal resistance of electric spark machine and to force injecting for the discharge fluid, it made the fixed table for a work piece to minimize the work error by means of one's failure during the electric discharging According to above results, the surface roughness by the variation of electrodw and current was analyzed to compare KS(Korea Standards) It was decided the optimum condition of electric discharge cutting through analyzing the effect of electric discharge speed and electro wear ratio.

  • PDF

Development of the Practical Garment Apparatus to Measure Vital Sign of ECG for U-Health Care (ECG 생체신호 측정을 위한 실용적 U-헬스케어 의복개발)

  • Park, Hye-Jun;Hong, Kyung-Hi;Kim, Seung-Hwan;Shin, Seung-Shul
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.31 no.2 s.161
    • /
    • pp.292-299
    • /
    • 2007
  • Development of portable device measuring the vital sign continuously with no limit of time and space is absolutely prerequisite for the U-health care that grafts the ubiquitous concept into medical system. Accordingly, it requires to develop a garment style apparatus for measuring vital-sign that is easy to wear on for a long time period. This study suggests a method to improve the insulation of electric cable and the skin adhesion of electrode by integrating the electric conductive material to garment, in order to develop a garment apparatus for measuring ECG for U-health care. Results of the research are as follows; In order to provide the adjacent conductive yarns with insulation, braid with narrow woven end was interlaced using polyester yarn. As a result, the direct contact between electric conductive yarns was restrained, which would be interposed into pin-tuck structured cable. Washable silicone gel applied around the electrode made of electric conductive fabric improved the adhesion, which prevents electrodes from dropping off from the skin surface during body movement. ECG signals on the human subject were tested using the garment apparatus developed by the above method. And the result was that the clear QRS wave formation in the typical form of ECG could be measured in both conditions of still and moving state as well. The result of this study is expected to contribute for the production of U-health care related medical apparatus by accelerating the practical uses of the garment measuring vital sign at a reasonable price.

Micro Electrical Discharge Milling Using Deionized Water (탈이온수를 이용한 미세 방전 밀링)

  • Chung Do-Kwan;Chu Chong-Nam;Kim Bo-Hyun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.3 s.180
    • /
    • pp.69-75
    • /
    • 2006
  • In this paper, micro electrical discharge milling using deionized water as dielectric fluid was investigated. In EDM, dielectric fluid is an important factor which affects machining characteristics. When deionized water was used as dielectric fluid, machining characteristics were investigated according to voltage, capacitance, and resistivity of deionized water. Machining gap increased with increasing voltage and capacitance. As the resistivity of deionized water decreased, the machining gap increased. The wear of a tool electrode and machining time can be reduced by using deionized water instead of EDM oil. Surface roughness was also improved when deionized water was used.

Characteristics of RC Circuit with Transistors in Micro-EDM (트랜지스터 부착 RC 방전회로의 마이크로 방전가공 특성)

  • Cho Pil Joo;Yi Sang Min;Choi Deok Ki;Chu Chong Nam
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.12
    • /
    • pp.44-51
    • /
    • 2004
  • In a micro-EDM, it is well known that an RC circuit is suitable as a discharge circuit because of its low pulse width and relatively high peak current. To increase machining speed without changing unit discharge energy, charge resistance should be decreased. But, when the resistance is very low, continuous (or normal) arc discharge occurs, electrode wear increases and machining speed is reduced remarkably. In this paper, an RC circuit with transistors is used in a micro-EDM. Experimental results show that the RC circuit with transistors can cut off a continuous (o. normal) arc discharge effectively if the duty factor and switching period of the transistor are set up optimally. Through experiments with varying charge resistances, it is shown that the RC circuit with transistors has about two times faster machining speed than that of an RC circuit.

PZT membrane Piezoelectric Traveling Wave Motor

  • xin, Shen-De;an, Zhang-Bao;Lu jinan-guo;qing, Yang-Gen;yuan, Wang-Wei
    • Journal of the Korean Vacuum Society
    • /
    • v.6 no.S1
    • /
    • pp.89-95
    • /
    • 1997
  • A new type of piexoelectric membrane traveling wave motor has been designed and forbricated. The small motor is composed by the stator which is the combination of annular/circular membrane and metal elastic base using as the common electrode at some time and the rotor which is placed on the metal elastic body. Thus the motor structure is simple and easy to fabricate. The material of a piezoelectric membrane is fabricated by sol-gel method or wear-down method. A piezoelectric traveling wave motor has been fabricated with the stator diameter 8mm The total thickness of the stator is 350$\mu$m. Under the alternative excitation voltage 10-12V the revolving speed of the rotor is more than 100RPM.

  • PDF

Estimation of Material Removal Volume of a Micro-EDM Drilled Hole Using Discharge Pulse Monitoring

  • Jung, Jae-Won;Ko, Seok-Hoon;Jeong, Young-Hun;Min, Byung-Kwon;Lee, Sang-Jo
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.8 no.4
    • /
    • pp.45-49
    • /
    • 2007
  • When drilling using electrical-discharge machining (EDM), severe electrode wear makes in-process measurements of the depth of the drilled hole and the volume of material removed impossible. To estimate the volume of material removed a reliable real-time discharge pulse counting method is proposed by assuming that the volume removed in EDM is proportional to the number of discharge pulses from an iso-energy pulse generator. The geometry of machined holes, including depths and cross-sectional profiles, is estimated using geometric analysis. A proportional relationship between the volume of material removed and the number of discharge pulses was developed and verified by experiments.

Low Voltage Atmospheric Plasma Generation using DBD Initiation Carrier Injection (유전체 장벽 방전(DBD) 씨드 캐리어를 이용한 저 전압 대기압 플라즈마 발생)

  • Hwang, Sol;Park, Hyunho;Kim, Youngmin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.1
    • /
    • pp.82-86
    • /
    • 2018
  • Low voltage atmospheric plasma generation using DBD Initiation carrier injection is reported. DBD afterglow was used as initiation carriers prior to a primary discharge and a significant reduction in the breakdown voltage of atmospheric discharge was observed when sufficient initiation carriers were provided. Quantative correlation study between the breakdown voltage and the initiation carriers suggests that the atmospheric breakdown voltage reduces to only half of the breakdown voltage for Townsend regime. Also, use of DBD initiation carrier injection likely offers better device reliability by protecting electrodes with a dielectric layer and thus suppressing electrode wear.

Pattern Recognition of Dynamic Resistance and Real Time Quality Estimation (동저항 패턴 인식 및 실시간 품질 평가)

  • 조용준;이세헌
    • Proceedings of the KWS Conference
    • /
    • 2000.04a
    • /
    • pp.303-306
    • /
    • 2000
  • Quality estimation of the weld has been one of the important issues in RSW which is a main process of the sheep metal fabrication in auto-body industry, It was well known that among the various welding process variables, dynamic resistance has a close relation with nugget formation. With this variable, it is possible to estimate the weld quality in real time. In this study, a new quality estimation algorithm is developed with the primary dynamic resistance measured at welding machine timer. For this, feature recognition method of Hopfield neural network is used. Primary resistance patterns are vectorized and classified with five patterns. The network trained by these patterns recognizes the dynamic resistance pattern and estimates the weld quality Because the process variable monitored at the primary circuit is used, it is possible to apply this system to real time application without any consideration of electrode wear or shunt effect.

  • PDF

Characteristics of RC circuit with Transistor in Micro-EDM (트랜지스터 부착 RC 방전회로의 마이크로 방전가공 특성)

  • 조필주;이상민;최덕기;주종남
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.235-240
    • /
    • 2002
  • In micro-EBM, it is well blown that RC circuit is suitable for discharge circuit because of its low pulse width and relatively high peak current. To increase machining speed without changing unit discharge energy, charge resistance should be decreased. But, if very low, continuous (or normal) arc discharge occurs, then increases electrode wear and reduces machining speed remarkably. In this paper, RC circuit with transistor is used to micro-EDM. Experimental results show that RC circuit with transistor can cut off continuous (or normal) arc discharge effectively if duty factor and switching period of transistor are set up optimally. Through experiments with varying charge resistance, it can be known that RC circuit with transistor has about two times faster machining speed than that of RC circuit. Especially, it has prominent rise-effect of machining speed in low unit discharge energy, so that a high-quality and high-speed micro-EDM can be realized through RC circuit with transistor.

  • PDF