• 제목/요약/키워드: electrode impedance

검색결과 686건 처리시간 0.031초

Characterization of a LSCF/GDC Cathode Composite in Solid Oxide Fuel Cells Using Impedance Spectroscopy

  • Hwang, Jin-Ha;Lee, Byung-Kook
    • 한국세라믹학회지
    • /
    • 제42권12호
    • /
    • pp.793-799
    • /
    • 2005
  • A composite cathode of LSCF$(La_{0.6}Sr_{0.4}Co_{0.2}Fe_{0.8}O_3)\;and\;GDC\; (Gd_2O_3-doped\;CeO_2:Ce_{0.9}Gd_{0.1}O_{1.95_})$ was characterized in terms of an electrode response, using a point contact in an Yttria-Stabilized Zirconia (YSZ) electrolyte incorporated into AC two-point impedance spectroscopy. The point-contacted configuration amplifies the responses occurring near the YSZ/cathode interface through the aligned point contact on the planar LSCF/GDC electrode. The point contact interface increases the bulk resistance allowing the estimation of the point contact geometry and resolving the electrode-related responses. The resultant impedance spectra are analyzed through an equivalent circuit model constructed by resistors and constant phase elements. The bulk responses can be resolved from the electrode-related portions in terms of spreading resistance. The electrode-related polarizations are measured in terms of temperature and oxygen partial pressure. The modified impedance spectroscopy is discussed in terms of methodology and analytical aspects, toward resolving the electrode-polarization issues in solid oxide fuel cells.

펄스코로나 방전의 전극길이, 펄스반복율에 따른 부하 임피던스 변화 특성 및 EMTP 해석 (The EMTP Analysis and Characteristics of Load Impedance on Various Electrode length, Pulse Repetition in Pulse Corona Discharging)

  • 정종한;송우정;전진안;정현주;홍정환;김희제
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권4호
    • /
    • pp.158-163
    • /
    • 2002
  • The pulsed Power system has been widely used to many applications, such as E/P(Electrostatic Precipitator), DeNOx/DeSOx power system, often generator, etc. In this paper, we study EMTP analysis and characteristics of critical voltage and load in impedance on various electrode length of pulse corona. To obtain a stable pulse voltage, we designed a compact pulse generator switched MOSFET and tested their characteristics by adjusting electrode length and pulse repetition. As a re sult, critical voltage of pulse corona and load impedance on increasing electrode length were decreased. These results indicate we can control critical voltage of pulse corona and suppress arc discharging between two electrodes.

다중 채널 전극의 제작 및 특성 평가 (Fabrication and Characterization of Multi-Channel Electrode Array (MEA))

  • 성락선;권광민;박정호
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제51권9호
    • /
    • pp.423-430
    • /
    • 2002
  • The fabrication and experimentation of multi-channel electrodes which enable detecting and recording of multi-site neuronal signals have been investigated. A multi-channel electrode array was fabricated by depositing 2000${\AA}$ thick Au layer on the 1000${\AA}$ thick Ti adhesion layer on a glass wafer. The metal paths were patterned by wet etching and passivated by depositing a PECVD silicon nitride insulation layer to prevent signals from intermixing or cross-talking. After placing a thin slice of rat cerebellar granule cell in the culture ring located in central portion of the multi-channel electrode plate, a neuronal signal from an electrode which is in contact with the cerebellar granule cell has been detected. It was found that the electrode impedance ranges 200㏀∼1㏁ and the impedance is not changed by cleaning with nitric acid. Also, the impedance is inversely proportion to the exposed electrode area and the cross-talk is negligible when the electrode spacing is bigger than 600$\mu\textrm{m}$. The amplitude and frequency of the measured action potential were 38㎷ and 2㎑, which are typical values. From the experimental results, the fabricated multi-channel electrode array proved to be suitable for multi-site neuronal signal detection for the analysis of a complicated cell network.

금 전극을 이용한 동물 조직 내 임피던스 측정연구 (A Study on the Measurement of Impedance in Animal Tissue Using Gold Electrodes)

  • 김민수;조영창
    • 전기전자학회논문지
    • /
    • 제25권3호
    • /
    • pp.445-450
    • /
    • 2021
  • 생체임피던스 측정법은 편리성, 저비용 및 저가의 장치를 이용하여 생체정보 획득 및 피부 병 진단 등에 사용 가능한 장치이다. 본 연구에서는 생체 삽입형으로 생체 정보를 획득하기 위해서 동물 생체 모델링을 통한 시뮬레이션 연구와 직접 제작한 건식용 금 전극을 이용하여 생체임피던스를 측정하였다. 동물 조직의 피하부위에 전극을 삽입하여 2 전극법으로 100 uA, 1-100 kHz 주파수를 인가하여 임피던스를 측정하였다. 측정결과 전극의 사이즈를 5 mm전극기준으로 7.5 mm, 10 mm전극과 비교하여 저항을 측정한 결과 5 mm 전극에서 높게 측정됨을 확인할 수 있다. 5 mm전극을 기준으로 7.5 mm 전극은 전체 주파수 범위에서 평균 1.49 %차이를 발견하였고, 10 mm 전극은 2.624 %로 임피던스가 차이남을 확인하였다. 향후, 연구결과는 생체 삽입형 심전도 센서 전극 설계 및 제작 등에 활용가치가 있을 것으로 사료된다.

다채널 미세전극칩 임피던스 분석을 위한 자동 스위칭 시스템: 한계점 및 개선 방안 (Automatic Switching System for The Impedance Analysis of Multichannel icroelectrode Arrays: Limits and Improvement Scheme)

  • 이석영;남윤기
    • 대한의용생체공학회:의공학회지
    • /
    • 제32권3호
    • /
    • pp.207-217
    • /
    • 2011
  • Electrode impedances are measured to quantitatively characterize the electrode-electrolyte or cell-electrode interfaces. In the case of high-density microelectrode arrays(MEAs) that have been developed for brainmachine interface applications, the characterization process becomes a repeating and time-consuming task; a system that can perform the measurement and analysis in an automated fashion with accuracy and speed is required. However, due to the large number of channels, parasitic capacitance and off-capacitance components of the switching system become the major factors that decreased the accuracy for the measurement of high impedance microelectrodes. Here we investigated the implementation of automatic impedance measurement system with analyzing the causes of possible measurement-related problems in multichannel switching configuration. Based on our multi-channel measurement circuit model, we suggest solutions to the problems and introduce a novel impedance measurement scheme using electro-mechanical relays. The implemented measurement system could measure |Z| < 700 $k{\Omega}$ of impedance in - 10% errors, which can be widely applicable to high density neural recording MEAs.

수직 접지전극의 접지임피던스 측정에서 도전유도에 의한 오차 평가 (Evaluation of Errors Due to Earth Mutual Resistance in Measuring Ground Impedance of Vertically-driven Ground Electrode)

  • 최종혁;최영철;이복희
    • 전기학회논문지
    • /
    • 제58권9호
    • /
    • pp.1778-1783
    • /
    • 2009
  • Ground impedance for the large grounding system is measured according to the IEEE Standard 81.2 which is based on the revised fall-of-potential method of installing auxiliary electrode at a right angle. When the auxiliary electrodes are located at an angle of $90^{\circ}$, the ground impedance inevitably includes the error due to earth mutual resistance. In this paper, in order to accurately measure the ground impedance of vertically-driven ground electrodes, error rates due to earth mutual resistance are evaluated by ground resistance and ground impedance measuring devices and compared with calculated values. As a result, the measured results are in good agreement with the computed results considering soil layer with different resistivity. The error rates due to earth mutual resistance decrease with increasing the length of ground electrode in the case that the ratio of the distance between the ground rod to be measured and the auxiliary electrodes to the length of ground electrode(D/L) is same. The ground impedance should be measured at the minimum distance between the auxiliary electrodes that will have an estimated measurement accuracy due to earth mutual resistance.

나피온 폴리머를 이용한 금 전극의 표면 개질 및 이의 삼투압 측정용 임피던스 센서 응용 (Surface Modification of Gold Electrode Using Nafion Polymer and Its Application as an Impedance Sensor for Measuring Osmotic Pressure)

  • 길민식;김민재;윤조희;장진우;이경균;최봉길
    • 공업화학
    • /
    • 제34권1호
    • /
    • pp.9-14
    • /
    • 2023
  • 본 논문에서는 용액의 이온 농도 측정이 가능한 나피온 폴리머(Nafion polymer) 코팅 기반 2상 금 전극의 임피던스(Impedance) 센서를 개발하였다. 스퍼터링(Sputtering) 공정을 통해서 제작된 금 전극의 표면을 나피온 폴리머를 사용하여 표면 개질 하였다. 상기 제작된 전극은 분극 현상 제어가 가능하여 전기화학적 신호를 안정적으로 측정할 수 있도록 하였다. 분광학과 전자주사현미경 관찰을 통하여 박막의 나피온 폴리머 코팅을 확인하였다. 나피온 코팅이 된 전극은 기존 금 전극에 비해 안정적인 임피던스 신호를 보여 주었으며, 표준 염화나트륨(NaCl) 용액 사용 시 임피던스 센서의 신뢰성 높은 검정 곡선(R2 = 0.983)을 나타내었다. 또한, 임피던스 센서는 상용화 전도도 장치와 인공 눈물의 이온 농도 측정 비교 실험을 진행하였으며, 유사한 결과값을 확인하였다.

On eliminating electrochemical impedance signal noise using Li metal in a non-aqueous electrolyte for Li ion secondary batteries

  • Park, Chul-Wan
    • Carbon letters
    • /
    • 제12권3호
    • /
    • pp.180-183
    • /
    • 2011
  • Li metal is accepted as a good counter electrode for electrochemical impedance spectroscopy (EIS) as the active material in Li-ion and Li-ion polymer batteries. We examined the existence of signal noise from a Li-metal counter quantitatively as a preliminary study. We suggest an electrochemical cell with one switchable electrode to obtain the exact impedance signal of active materials. To verify the effectiveness of the switchable electrode, EIS measurements of the solid electrolyte interphase (SEI) before severe $Li^+$ intercalation to SFG6 graphite (at > ca. 0.25 V vs. Li/$Li^+$) were taken. As a result, the EIS spectra without the signal of Li metal were obtained and analyzed successfully for the following parameters i) $Li^+$ conduction in the electrolyte, ii) the geometric resistance and constant phase element of the electrode (insensitive to the voltage), iii) the interfacial behavior of the SEI related to the $Li^+$ transfer and residence throughout the near-surface (sensitive to voltage), and iv) the term reflecting the differential limiting capacitance of $Li^+$ in the graphite lattice.

Electrochemical Oxidation of Ethanol at $RuO_2-Modified$ Nickel Electrode in Alkaline Media Studied by Electrochemical Impedance Spectroscopy

  • Kim Jae-Woo;Park Su-Moon
    • 전기화학회지
    • /
    • 제3권2호
    • /
    • pp.76-80
    • /
    • 2000
  • Electrochemical oxidation of ethanol has been studied at nickel and $RuO_2-modified$ nickel electrodes in 1 M KOH using electrochemical impedance spectroscopy. Equivalent circuits have been worked out from simulation of impedance data to model oxidation of ethanol as well as the passivation of the electrode. The charge-transfer resistances for oxidation of these electrodes became smaller in the presence of ethanol than in its absence. The nickel substrate facilitated ethanol oxidation at $RuO_2-modified$ nickel electrodes. We also describe the Performance of nanosized electrocatalysts of the same composition in comparison to those of the bulk electrodes. The nanosized electrodes were obtained by electrode-positing the alloy from complexed form of these metal ions with fourth and fifth generation polyamidoamine dendrimers.

전극/전해질 계면의 전기화학적 임피던스 측정 및 전기회로 모델 연구 (A Study on the Electrochemical Impedance Spectroscopy and the Electrical Circuit Model for the Electrode/Electrolyte Interface)

  • 장종현;홍장원;박정호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.274-275
    • /
    • 2007
  • The investigation of the equivalent circuit models for the electrode/electrolyte interface has been pursued for a long time by several researchers. Previous circuit models fit the experimental results in limited conditions such as frequency range, type of electrode, or electrolyte. This paper describes a new electrical circuit model and its capability of fitting the experimental results. Electrochemical impedance spectroscopy was used to characterize the interface for Au, Pt, and stainless steel electrode in 0.9% NaCl solution. Both the proposed model and the previous model were applied to fit the measured impedance results for comparison. The proposed model fits the experimental data more accurately than other models especially at the low frequency range, and it enables us to predict the impedance at very low frequency range, including DC, using the proposed model.

  • PDF