• Title/Summary/Keyword: electrode impedance

검색결과 686건 처리시간 0.041초

SUS 기판을 이용한 염료감응형 태양전지용 백금 상대전극의 전기화학적 특성 (Electrochemical Properties of Platinized Counter Electrode on based Stainless Steel Sheet for Dye-Sensitized Solar Cells)

  • 박경희;김태영;백형렬;구할본;김승재;조성용
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 추계학술대회 논문집 Vol.18
    • /
    • pp.262-263
    • /
    • 2005
  • Pt counter electrode based on flexible metal for dye-sensitized solar cells(DSCs) has been investigated. Photovoltaic structures on lightweight substrates have several advantages over the heavy glass-based structures in both terrestrial and space applications. Cyclic voltammetry and impedance spectroscopy were used to investigate electrochemical properties of Pt counter electrode both FTO glass and SUS sheet substrate. The DSCs composed of the counter electrode based on a stainless steel substrate has obtained conversion efficiencies comparable to that based on the conducting glass. The counter electrode based on the stainless steel substrate has the merit of improving the fill factor and conversion efficiency of the DSCs by reducing its internal resistance.

  • PDF

GZO/ZTO 투명전극을 이용한 DSSC의 광전 변환 효율 특성 (Sputtered ZTO as a blocking layer at conducting glass and $TiO_2$ Interfaces in Dye-Sensitized Solar Cells)

  • 박재호;이경주;송상우;조슬기;문병무
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.53.2-53.2
    • /
    • 2011
  • Dye-sensitized solar cells(DSSCs) have been recognized as an alternative to the conventional p-n junction solar cells because of their simple fabrication process, low production cost, and transparency. A typical DSSC consists of a transparent conductive oxide (TCO) electrode, a dye-sensitized oxide semiconductor nanoparticle layer, liquid redox electrolyte, and a Pt-counter electrode. In dye-sensitized solar cells, charge recombination processes at interfaces between coducting glass, $TiO_2$, dye, and electrolyte play an important role in limiting the photon-to-electron conversion efficiency. A layer of ZTO thin film less than ~200nm in thickness, as a blocking layer, was deposited by DC magnetron sputtering method directly onto the anode electrode to be isolated from the electrolyte in dye-sensitized solar cells(DSCs). This is to prevent the electrons from back-transferring from the electrode to the electrolyte ($I^-/I_3^-$). The presented DSCs were fabricated with working electrode of Ga-doped ZnO glass coated with blocking ZTO layer, dye-attached nanoporous $TiO_2$ layer, gel electrolyte and counter electrode of Pt-deposited GZO glass. The effects of blocking layer were studied with respect to impedance and conversion efficiency of the cells.

  • PDF

임피던스 방법을 이용한 체지방 측정 (Measurement of Body Fat by Impedance Technique)

  • 김덕원;송철규;황수관
    • 대한의용생체공학회:의공학회지
    • /
    • 제13권2호
    • /
    • pp.133-140
    • /
    • 1992
  • Bioelectrical Impedance method for measuring human body composition is based upon the principle that the electrical conductivity of the fat-free mass (FFM) is far greater than that of the (at. Deter- mination o( impedance was nlade in 30 healthy and obese men aged $40.9{\pm}14.7$yr (mean${\pm}$SD) and 25 healthy and obese women aged $44.0{\pm}10.2$ yr. A commercial impedance body fat analyzer was used with a four electrode arrangement that introduced a painless constant current(ImA at 50 kHz) into the body. Linear relationships were found between impudence values and FFM(r=-0.786) and between weight and FFM(r=0.837). Signigicant increases in the correlation coefficients were ob served when the predicator Hta/z was regressed against FFM(r=0.912) where Ht Is height and Z Is impedance. A linear regression equation, FFM=0.586(Htf/z) +0.317(Weight) -1.674(r=0.977), was found. The correlation coefficient of % body fat between the impedance and infrared methods was 0.898. These data Indicate that the bioelectrical impedance technique is a reliable and valld approach for the estimation of human body composition. This method Is safe, noninvasivr, prouides rapld measure menu, requires little operator skill and subject cooperation, and Os portable. Finally measurement of percent body fat was made possible using both the regression equation and a developed impedance measuring device which measures impedance between wrist and ankle.

  • PDF

임피던스법을 이용한 혈류량 변화 측정 (Measurement of Blood Flow Variation using Impedance Method)

  • 정도운;강성철;전계록
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2006년도 춘계종합학술대회
    • /
    • pp.693-696
    • /
    • 2006
  • 본 연구에서는 생체 임피던스의 변화를 계측하여 혈류량의 변화를 추정하기 위한 시스템을 구현하였다. 구현된 시스템은 인위적인 압력을 가하여 압력의 변화에 따른 임피던스의 변화량을 측정할 수 있도록 구성하였으며, 크게 압력 측정부와 4 전극법을 이용한 임피던스 측정부로 구분할 수 있다. 압력 측정부는 반도체식 압력센서와 센서의 출력신호를 처리하기 위한 전자회로부로 구성하였고, 임피던스 측정부는 교류 정전류원 회로와 임피던스 신호의 검출을 위한 락인 증폭기로 시스템을 구성하였다. 구현된 시스템의 성능평가를 위하여 표준저항을 이용한 임피던스 측정부의 특성조사 실험을 수행 하였다. 그리고 실제 실험군을 대상으로 임피던스의 계측을 통한 혈류량 변화 추정실험을 수행하였고, 혈류량 변화와 평균 동맥압을 이용한 혈류 저항비를 추정하였다 그 결과 혈류저항비와 혈류량의 변화는 반비례관계를 명확하게 보여 주었으며, 상관분석을 수행한 결과 상관계수가 -0.96776으로 강한 음의 상관관계를 나타내었다.

  • PDF

Comparison of Ablation Performance between Octopus Multipurpose Electrode and Conventional Octopus Electrode

  • Sae-Jin Park;Jae Hyun Kim;Jeong Hee Yoon;Jeong Min Lee
    • Korean Journal of Radiology
    • /
    • 제24권2호
    • /
    • pp.86-94
    • /
    • 2023
  • Objective: To compare Octopus multipurpose (MP) electrodes, which are capable of saline instillation and direct tissue temperature measurement, and conventional electrodes for radiofrequency ablation (RFA) in porcine livers in vivo. Materials and Methods: Sixteen pigs were used in this study. In the first experiment, RFA was performed in the liver for 6 minutes using Octopus MP electrodes (n = 15 ablation zones) and conventional electrodes (n = 12 ablation zones) to investigate the effect of saline instillation. The ablation energy, electrical impedance, and ablation volume of the two electrodes were compared. In the second experiment, RFA was performed near the gallbladder (GB) and colon using Octopus MP electrodes (n = 12 ablation zones for each) with direct tissue temperature monitoring and conventional electrodes (n = 11 ablation zones for each). RFA was discontinued when the temperature increased to > 60℃ in the Octopus MP electrode group, whereas RFA was performed for a total of 6 minutes in the conventional electrode group. Thermal injury was assessed and compared between the two groups by pathological examination. Results: In the first experiment, the ablation volume and total energy delivered in the Octopus MP electrode group were significantly larger than those in the conventional electrode group (15.7 ± 4.26 cm3 vs. 12.5 ± 2.14 cm3, p = 0.027; 5.48 ± 0.49 Kcal vs. 5.04 ± 0.49 Kcal, p = 0.029). In the second experiment, thermal injury to the GB and colon was less frequently noted in the Octopus MP electrode group than that in the conventional electrode group (16.7% [2/12] vs. 90.9% [10/11] for GB and 8.3% [1/12] vs. 90.9% [10/11] for colon, p < 0.001 for all). The total energy delivered around the GB (2.65 ± 1.07 Kcal vs. 5.04 ± 0.66 Kcal) and colon (2.58 ± 0.57 Kcal vs. 5.17 ± 0.90 Kcal) were significantly lower in the Octopus MP electrode group than that in the conventional electrode group (p < 0.001 for all). Conclusion: RFA using the Octopus MP electrodes induced a larger ablation volume and resulted in less thermal injury to the adjacent organs compared with conventional electrodes.

축전식 이온제거에 대한 $TiO_2$/Activated Carbon 화합물의 전기흡착 거동 (Electrosorption Behavior of $TiO_2$/Activated Carbon Composite for Capacitive Deionization)

  • 이정원;김홍일;김한주;박수길
    • 공업화학
    • /
    • 제21권3호
    • /
    • pp.265-271
    • /
    • 2010
  • 활성탄에 $TiO_2$를 졸-겔 방법으로 코팅하여 탄소복합전극을 제조하였고 축전식 이온제거(Capacitive deionization : CDI) 과정에서 나타난 제염효과에 대하여 고찰하였다. 본 연구에서 $TiO_2$는 전극의 젖음성을 향상시켜 전극과 전해질의 접촉 저항을 감소시키고, 전기이중층 흡착량을 증가시킬 수 있으므로 CDI전극재로 활성탄에 코팅하였다. TEM, XRD, XPS로 활성탄에 $TiO_2$가 코팅되었는지 확인하였다. 순환전류전압법과 impedance측정 결과 탄소복합전극이 탄소전극보다 전기이중층 용량이 증가하였으며, 전극의 확산저항이 줄어든 것을 확인하였다. 또한 이온제거율을 확인하기 위한 충전-방전 및 이온전도도 평가 결과 전해질 NaCl $1000\;{\mu}S/cm$에서 탄소복합전극이 탄소전극보다 39% 더 많은 이온을 제거하는 것을 확인하였다. 본 연구 결과 CDI용 전극재료 $TiO_2$가 코팅된 탄소복합전극이 탄소전극보다 효과적인 제염효과를 보임을 확인하였다.

Impedance Analysis of Resistance Anomaly of $BaTiO_3$ based PTC thermistor

  • Chun, Myoung-Pyo;Myoung, Seong-Jae;Nam, Joong-Hee;Cho, Jeong-Ho
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.182-182
    • /
    • 2009
  • The effect of Re-oxidation on the PTCR properties of Sm-doped barium titanate ceramics was investigated by means of impedance spectroscopy. Electrical properties such as resistance vs. temperature, I-V curve were measured and microstructure was observed with SEM photography. Sample was fabricated with thick film process such as tape casting of green sheet, screen printing of electrode pattern, stacking, firing in reduced atmosphere and re-oxidation, etc. As the temperature of re-oxidation increases, resistance jump as a function of temperature enhances but resistance at room temperature increases. These behavior of resistance as a function of temperature, dependent on the re-oxidation condition, is analyzed with Cole-Cole impedance plot and is shown to be related with the degree of oxidation of grain boundary regardless of grain core during re-oxidation process of sample.

  • PDF

전기임피던스 단층촬영법을 위한 단순화된 매모그래피 구조의 모델 (A Model of a Simplified Mammography Geometry for Breast Cancer Imaging with EIT)

  • 최명환
    • 산업기술연구
    • /
    • 제26권B호
    • /
    • pp.221-226
    • /
    • 2006
  • Electrical impedance tomography (EIT) is a technique for determining the electrical conductivity and permittivity distribution within the interior of a body from measurements made on its surface. One recent application area of the EIT is the detection of breast cancer by imaging the conductivity and permittivity distribution inside the breast. The present "gold standard" for breast cancer detection is X-ray mammography, and it is desirable that EIT and X-ray mammography use the same geometry. This paper presents a forward model of a simplified mammography geometry for EIT imaging. The mammography geometry is modeled as a rectangular box with electrode arrays on the top and bottom planes. A forward model for the electrical impedance imaging problem is derived for a homogeneous conductivity distribution and Validated by experiment using a phantom tank.

  • PDF

백금 전극에 입힌 폴리아닐린의 전기화학적 임피던스 (Electrochemical Impedance Analysis of Polyaniline-Film on Platinum Electrodes)

  • 천정균;민병훈
    • 대한화학회지
    • /
    • 제39권9호
    • /
    • pp.722-727
    • /
    • 1995
  • 순환 전압-전류법으로 합성한 폴리아닐린 막의 전기화학적 임피던스 측정을 0.1M 황산용액에서 수행하였다. 전기 전도성을 갖는 퍼텐셜 영역에서 전하-이동 정항은 낮은 값을 나타냈으며, 따라서 교환 전류밀도는 큰 값으로 측정되었다. 고분자의 축전 용량은 이중층 축전 용량보다 크게 나타났으며 이값은 전극 퍼텐셜에 따라 변하였다. 측정된 임피던스 데이터로부터 전극의 등가 회로를 추정하였으며, 이 등가 회로를 토대로 하여 폴리아닐린 막대에서 혼입된 이온의 물질 이동 파라미터를 산출하였다.

  • PDF

대규모 그리드 접지전극의 과도접지임피던스의 측정 (The transient grounding impedance measurment of large grid grounding electrodes)

  • 전병욱;이수봉;이봉;이승주;정동철;이복희
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 추계학술대회 논문집
    • /
    • pp.69-72
    • /
    • 2008
  • This paper presents the transient and conventional grounding impedance behaviors of large grid grounding system associated with the injection point of impulse current The measurement methods consider two possible errors in the grounding-system impedances: (1) ground mutual resistance due to current flow through ground from the ground electrode to be measured to the current auxiliary, (2) ac mutual coupling between the current test lead and the potential test lead The test circuit was set to reduce the error factors. The transient grounding impedance depends on the rise time and injection point of impulse current It is effective that grounding conductor is connected to the center of the large grid grounding system.

  • PDF