• Title/Summary/Keyword: electrode array

Search Result 224, Processing Time 0.026 seconds

Fabrication of silicon field emitter array using chemical-mechanical-polishing process (기계-화학적 연마 공정을 이용한 실리콘 전계방출 어레이의 제작)

  • 이진호;송윤호;강승열;이상윤;조경의
    • Journal of the Korean Vacuum Society
    • /
    • v.7 no.2
    • /
    • pp.88-93
    • /
    • 1998
  • The fabrication process and emission characteristics of gated silicon field emitter arrays(FEAs) using chemical-mechanical-polishing (CMP) method are described. Novel fabrication techniques consisting of two-step dry etching with oxidation of silicon and CMP processes were developed for the formation of sharp tips and clear-cut edged gate electrodes, respectively. The gate height and aperture could be easily controlled by varying the polishing time and pressure in the CMP process. We obtained silicon FEAs having self-aligned and clear-cut edged gate electrode opening by eliminating the dishing problem during the CMP process with an oxide mask layer. The tip height of the finally fabricated FEAs was about 1.1 $\mu$m and the end radius of the tips was smaller than 100 $\AA$. The emission current meaured from the fabricated 2809 tips array was about 31 $\mu$A at a gate voltage of 80 V.

  • PDF

Optimization of GTAW Parameters for Horizontal Welding of a STS316L Pipe (STS316L 강관의 수평자세 용접을 위한 GTAW 용접조건의 최적화)

  • Lee, Hyoung-Keun;Bang, Kyoung-Sik
    • Journal of Welding and Joining
    • /
    • v.33 no.5
    • /
    • pp.47-52
    • /
    • 2015
  • In this study, it was tried to analyze the effects of welding parameters on the weld penetration and aspect ratio when a STS316L pipe was welded in a horizontal position by GTAW. Experiments were systematically designed using a L18 orthogonal array, and the effects of welding parameters were statistically analyzed by ANOVA(Analysis of Variance). The shielding gas type has the largest effect on both the penetration and aspect ratio. The welding current type and shielding gas flow rate have a little effect on the penetration, whereas the electrode tip angle has a little effect on the aspect ratio. When welded at a selected welding condition, which is composed of He shielding gas, pulse current of 300/45 A, electrode tip angle of 90o, and shielding gas flow rate of 30 l/min, the estimated interval at least 95 % confidence was $1.99{\pm}0.18mm$ for the penetration and $0.31{\pm}0.04$ for the aspect ratio. From the confirmation experiments, the average penetration and aspect ratio were well agreed with the estimation as 1.96 mm and 0.30, respectively. Additionally, the effects of the welding speed and welding current on the penetration and aspect ratio were experimented and analyzed by linear regression. The penetration was linearly increased with the decrease of the welding speed and with the increase of the welding current, but the aspect ratio showed a tendency to a little decrease with the increase of both the welding speed and current.

Study of Seal-off Triggered Vacuum Switch(TVS) for High Voltage and High Current (고전압 대전류용, Seal-off TVS(Triggered Vacuum Switch) 연구)

  • Park, S.S.;Han, Y.J.;Kim, S.H.;Kwon, Y.K.;Kim, S.H.;Park, Y.J.;Hong, M.S.;Nam, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1823-1826
    • /
    • 2002
  • The purpose of this experiment was to develope Triggered Vacuum Switch (TVS) for the high voltage and high current. The TVS has an array of rods of alternate polarity in which a fixed gap spacing is maintained between the rods. The cross section of each rod has trapezoidal shape. It consists of electrode, ceramic chamber, getter and trigger. Currently, triggered vacuum switch (TVS) with seal-off has been designed and fabricated at PAL. An experimentation and trigger devices for TVS were designed for testing characteristics of electricity. For making the prototype of TVS, it is developed of fabrication process and fined of electrode material. The fabrication of the TVS is a lot of process which have manufacturing of part, chemical clean, ceramic brazing and metal welding. The fabricated TVS is tested of leak for vacuum, hold-off voltage and conditioning of trigger system. The TVS has pinch-off after it is removed of gas in the TVS and activated of getter in degassing furnace. The prototype TVS tested about 20 kV, 75 kA, 83 ${\mu}s$ with 100 kJ capacitor bank and inductance 5 ${\mu}H$. This paper describes the results of tests and the characteristics of the switch.

  • PDF

Geophysical Survey in the Taran Area on the Central Kalimantan, Indonesia (인도네시아 중부 칼리만탄 타란지역에서의 물리탐사)

  • 조진동;김인준;박인화
    • Economic and Environmental Geology
    • /
    • v.35 no.2
    • /
    • pp.155-162
    • /
    • 2002
  • There are many typical epithermal deposits scattering in the Taran of central Kalimantan. Indonesia. To get the shallow geological information, we carried out the geophysical exploration: spontaneous potential survey, in-suite magnetic susceptibility measurement and relistivity survey method in this area for a few weeks from September 30th to October 27th in 1997. SP survey (Fluke 27 multimeter)/magnetic susceptibility (EK -7 meter) measurement was carried out with a 250m$\times$10m lattice net in N45$^{\circ}$W direction. The dipole-dipole array resistivity survey was conducted with an electrode spacing of ${\alpha}$=30 m and electrode separation index n=7 at the line 5. The result shows that was the gold bearing quartz vein area can be divided into two type lone: low sulfidation type and high sulfidation type zone. The low resistivity value in the survey line 5 indicated a fracture Bone associated with the high sulfidation zone.

Effectiveness of the Electrode Arrays for Delineating 2-D Subsurface Structure (2차원 지하구조 규명을 위한 전극배열의 효율성)

  • Yoon, Jong-Ryeol;Lee, Kiehwa
    • Economic and Environmental Geology
    • /
    • v.29 no.3
    • /
    • pp.345-355
    • /
    • 1996
  • The effectiveness of various electrode configurations in horizontal mappings and 1-D inversions of vertical sounding data for delineating 2-D structures was studied. Apparent resistivity values of three point, dipole-dipole, Wenner, and Schlumberger mappings were simulated for such structures as vertical dyke, tabular prism, buried vertical fault, ramp and complex structure by finite difference method (FDM) and they were compared with each other. Also 2-D cross sections for three structures obtained by interpolation of 1-D inverted sounding data in terms of three layers were compared for Schlumberger and Wenner arrays. On these cross sections, horizontal and vertical resistivity interfaces of the 2-D structures are revealed relatively clearly. Apparent resistivity curves of Schlumberger mapping show vertical resistivity discontinuities very well. On the whole, Schlumberger array is superior to the other arrays in electric sounding as well as mapping. This study clearly indicates that interpretations of 2-D structures based on 1-D inversion are possible.

  • PDF

Development of Multi Dielectric Barrier Discharge Plasma Reactor for Water Treatment (수처리용 다중 유전체 방벽 방전 플라즈마 반응기 개발)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.22 no.7
    • /
    • pp.863-871
    • /
    • 2013
  • Dielectric discharges are an emerging technique in environmental pollutant degradation, which that are characterized by the production of hydroxyl radicals as the primary degradation species. For practical application of the plasma reactor, reactor that can handle large amounts of water are needed. Plasma research to date has focused on small-scale water treatment. This study was carried out basic study for scale-up of a single DBD (dielectric barrier discharge) plasma reactor. The degradation of N, N-Dimethyl-4-nitrosoaniline (RNO, indicator of the generation of OH radical) was used as a performance indicator of multi-plasma reactor. The experiments is divided into two parts: design parameters [effect of distance of single plasma module (1~14 cm), arrangement of ground electrode (single and multi), rector number (1~5) and power number (1~5)]; operation parameter [effect of applied voltage (60~220 V), air flow rate (1~5 L/min), electric conductivity of solution ($1.4{\mu}S/cm$, deionized water)~18.8 mS/cm (addition of NaCl 10 g/L) and pH (5~9)]. Considering the electric stability of the plasma reactor, optimum spacing between the single plasma module was 2 cm. Multi discharge electrodes - single ground electrode array was selected. Combination of power 3-plasma module 5 was the optimal combination for maximum RNO degradation. The optimum 1st voltage and air flow rate for RNO degradation were 180 V and 4 L/min, respectively. The pH and conductivity of the solution was not influencing the RNO degradation.

Properties of Urchin-Structured Zinc Oxide Nanorods Gas Sensor by Using Polystyrene Sphere Array (Polystyrene 입자 정렬을 이용한 성게 구조 ZnO 나노막대 가스 센서의 특성)

  • Kim, Jong-Woo;Kim, Do Hoon;Ki, Tae Hoon;Park, Jung Hyuk;Myoung, Jae-Min
    • Korean Journal of Materials Research
    • /
    • v.27 no.12
    • /
    • pp.658-663
    • /
    • 2017
  • Urchin-structured zinc oxide(ZnO) nanorod(NR) gas sensors were successfully demonstrated on a polyimide(PI) substrate, using single wall carbon nanotubes(SWCNTs) as the electrode. The ZnO NRs were grown with ZnO shells arranged at regular intervals to form a network structure with maximized surface area. The high surface area and numerous junctions of the NR network structure was the key to excellent gas sensing performance. Moreover, the SWCNTs formed a junction barrier with the ZnO which further improved sensor characteristics. The fabricated urchin-structured ZnO NR gas sensors exhibited superior performance upon $NO_2$ exposure with a stable response of 110, fast rise and decay times of 38 and 24 sec, respectively. Comparative analyses revealed that the high performance of the sensors was due to a combination of high surface area, numerous active junction points, and the use of the SWCNTs electrode. Furthermore, the urchin-structured ZnO NR gas sensors showed sustainable mechanical stability. Although degradation of the devices progressed during repeated flexibility tests, the sensors were still operational even after 10000 cycles of a bending test with a radius of curvature of 5 mm.

A Study on Application of Electrical Resistivity Survey to Detect the Leakage of Embankment with Weak Zone (취약대가 존재하는 제방의 누수 탐지를 위한 전기비저항 탐사의 적용성 연구)

  • Park, Samgyu;Kim, Jaehong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.4
    • /
    • pp.5-13
    • /
    • 2013
  • The water leakage of reservoir embankment usually occurs around channelling pipes, which gives little influence on the embankment in a normal state. However, the embankment can be destroyed when the water level of reservoir increases with heavy rain and the rainy season in summer. Investigating the water vein and its path is therefore very important from the viewpoint of disaster prevention and embankment maintenance. The water leakage in dams and levees where the channelling pipes are working as weak zone was analyzed by using both numerical simulation and experimental method in this study. To detect the water leakage, an electrical resistivity survey was used and investigated for its' usability. The numerical results show the size and location of weak zone increases the importance of selection of electrode spacing. The leakage experiments of model embankment present the best result is obtained under the conditions of electrode spacing of 0.3m and dipole-dipole array. By studying the water leakage in dams and levees, the electrical resistivity survey is observed it is a very useful method to predict the leakage.

Robust 1D inversion of large towed geo-electric array datasets used for hydrogeological studies (수리지질학 연구에 이용되는 대규모 끄는 방식 전기비저항 배열 자료의 1 차원 강력한 역산)

  • Allen, David;Merrick, Noel
    • Geophysics and Geophysical Exploration
    • /
    • v.10 no.1
    • /
    • pp.50-59
    • /
    • 2007
  • The advent of towed geo-electrical array surveying on water and land has resulted in datasets of magnitude approaching that of airborne electromagnetic surveying and most suited to 1D inversion. Robustness and complete automation is essential if processing and reliable interpretation of such data is to be viable. Sharp boundaries such as river beds and the top of saline aquifers must be resolved so use of smoothness constraints must be minimised. Suitable inversion algorithms must intelligently handle low signal-to-noise ratio data if conductive basement, that attenuates signal, is not to be misrepresented. A noise-level aware inversion algorithm that operates with one elastic thickness layer per electrode configuration has been coded. The noise-level aware inversion identifies if conductive basement has attenuated signal levels so that they are below noise level, and models conductive basement where appropriate. Layers in the initial models are distributed to span the effective depths of each of the geo-electric array quadrupoles. The algorithm works optimally on data collected using geo-electric arrays with an approximately exponential distribution of quadrupole effective depths. Inversion of data from arrays with linear electrodes, used to reduce contact resistance, and capacitive-line antennae is plausible. This paper demonstrates the effectiveness of the algorithm using theoretical examples and an example from a salt interception scheme on the Murray River, Australia.

Reliability improvement of an ion-measuring system using FET sensor array (FET 센서 어레이를 이용한 이온 측정 시스템의 신뢰도 개선)

  • Choi, Jung-Tae;Lee, Seung-Hyup;Kim, Young-Jin;Lee, Young-Chul;Cho, Byung-Woog;Sohn, Byung-Ki
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.341-346
    • /
    • 1999
  • In general cases, compared with glass electrode, FET type electrolyte sensors have many advantages. But the drift, memory effect and the poor reproducibility of the FET type electrolyte sensor cause the decrease of the reliability in the measurement system. To improve the reliability, an ion-measuring system using FET type electrolyte sensor array with 8 sensors has been developed. Developed system employed the electronic switchs to connect a signal detecting circuit with 8 sensor array and the system can measure ion concentration of 4 different type electrolyte($H^+$, $Na^+$, $K^+$, $Ca^{2+}$). The signal processing algorithm with insertion sorting method was adopted to enhance the reliability. We measured 3 different ion($H^+$, $Na^+$, $K^+$) to evaluate the performance of developed system. The results show that the designed signal processing algorithm can reduce the error range in comparison with a simple arithmetic mean and the developed system has a good reliability over the previous single channel sensor system.

  • PDF