• 제목/요약/키워드: electrochemical polarization test

검색결과 209건 처리시간 0.045초

핵 융합로 구조재료의 예민화 열처리에 따른 극저온 파괴거동 및 분극특성 (Cryogenic fracture behaviors and polarization characteristics according to sensitizing heat treatment on structural material of the nuclear fusion reactor)

  • 권일현;정세희
    • 대한기계학회논문집A
    • /
    • 제22권2호
    • /
    • pp.311-320
    • /
    • 1998
  • The cryogenic fracture behaviors of austenitic stainless steel HN2 developed for nuclear fusion reactor were evaluated quantitatively by using the small punch(SP) test. The electrochemical polarization test was applied to study thermal aging degradation of HN2 steel. The X-ray diffraction(XRD) analysis was conducted to detect carbides and nitrides precipitated on the grain boundary of the heat treated HN2 steel. The mechanical properties of the HN2 steel significantly decreased with increasing time and temperature of heat treatment or with decreasing testing temperature. The integrated charge(Q) obtained from electrochemical polarization test showed a good correlation with the SP energy(ESP) obtained by means of SP tests. From the results observed in the x-ray diffraction and anodic polarization curve, it was known that the material the grain boundary. Combining SP test and electrochemical polarization test, it could be useful tools to non-destructively evaluate the cryogenic fracture behaviors and the aging degradation for cryogenic structural material.

전기화학기법에 의한 슈퍼 오스테나이트 스테인리스강의 열화손상 평가 (An Evaluation of Degraded Damage for Superaustenitic Stainless Steel by Electrochemical Polarization Technique)

  • 권일현;이송인;백승세;이종기;;유효선
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집A
    • /
    • pp.143-148
    • /
    • 2001
  • This research was undertaken to clarify effects of thermal aging on electrochemical and mechanical properties of superaustenitic stainless steel. The steel was artificially aged at $300{\sim}650^{\circ}C$ for $240{\sim}10,000hrs$. and investigated at $-196{\sim}650^{\circ}C$ using small punch(SP) test. Also, the change in electrochemical properties caused by effects of thermal aging was investigated using electrochemical anodic polarization test in a KOH electrolyte. Carbides and ${\eta}-phase(Fe_2Mo)$ precipitated in the grain bounderies seem to deteriorate the mechanical properties by decreasing cohesive strength in the grain bounderies and promote the current density observed in electrochemical polarization curves. The electrochemical and mechanical properties of superaustenitic stainless steel was drastically decreased in the specimen aged at $650^{\circ}C$.

  • PDF

보일러용 STS 444재 용접부의 수소취성에 미치는습기의 영향 (Effect of Humidity on the Hydrogen Embrittlement of STS 444 Weld Zone for Boiler)

  • 임우조;최병일;윤병두
    • 수산해양교육연구
    • /
    • 제18권1호
    • /
    • pp.58-64
    • /
    • 2006
  • In order to examine the effect of humidity on hydrogen embrittlement of STS 444 weld zone for boiler with dry and wet welding conditions, this paper was carried out the accelerated hydrogen osmosis test and the electrochemical Tafel polarization test. In 0.5M $H_2SO_4$ + 0.01M $As_20_3$ solution, this test is added to load of $1400kg/cm^2$ together with hydrogen osmosis by current of $50 {mA/cm^2}$ for 60 min.. The electrochemical Tafel polarization test was carried out in 0.5M $H_2SO_4$ + 0.01M $As_20_3$ solution. Therefore, the effect of humidity on hydrogen embrittlement of STS 444 was considered. The main results are as following: On the basis of hydrogen embrittlement mechanism, that is, integrated electrochemical polarization characteristics with the established mechanism of hydrogen embrittlement, the reduction rate of corrosion current density of weld zone in the wet weld condition is larger than in the dry condition. We can nondestructively predict the degree of hydrogen embrittlement of STS 444 weld zone for boiler through the reduction rate of electrochemical corrosion current density.

마이크로 전해가공에서 임피던스의 영향 (The influence of impedance on micro electrochemical machining)

  • 강성일;주종길;박규열;전종업
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1893-1896
    • /
    • 2003
  • This research aimed to fabricate a micro structure using micro electrochemical machining (${\mu}$-ECM). with a view to that the theory of ${\mu}$-ECM is established accurately in a different way of conventional electrochemical machining. In details, if the impedance is existed in the system, it is difficult to analyze the micro electrochemical reaction efficiently in polarization curve using a potentiodynamic test. Hence, this research investigates the relationships between impedance and electric current measuring with a potentiostatic test applying to a pair or electrode as a constant potential. And this paper examines the influence of temperature of electrolyte on polarization curve for the quantitative analysis of electrochemical reactions.

  • PDF

슈퍼 오스테나이트 스테인리스강의 열화손상에 대한 비파괴적 평가 (An Nondestructive Evaluation of Degraded Damage for Superaustenitic Stainless Steel)

  • 권일현;백승세;;유효선
    • 대한기계학회논문집A
    • /
    • 제26권7호
    • /
    • pp.1332-1339
    • /
    • 2002
  • This research was undertaken to clarify effects of thermal aging on electrochemical and mechanical properties of superaustenitic stainless steel and to detect the material degradation nondestructively. The steel was artificially aged at $300{\sim}650^{\circ}C$ for $240{\sim}10,000h$ and the mechanical properties were investigated at $-196{\sim}650^{\circ}C$ using small punch(SP) test. Also, the change in electrochemical properties caused by effects of thermal aging on superaustenitic stainless steel was investigated using electrochemical anodic polarization test in a KOH electrolyte. Carbides and ${\eta}-phase(Fe_2Mo)$ precipitated in the grain boundaries seem to deteriorate the mechanical properties by decreasing cohesive strength in the grain boundaries and to promote the current density observed in electrochemical polarization curves, The electrochemical and mechanical properties of superaustenitic stainless steel decreased significantly in the specimen aged at $650^{\circ}C$ corresponding to the sensitization temperature for conventional austenitic stainless steels.

전기구리도금에 미치는 Mercapto화합물의 전기화학적 특성 (The Electrochemical Characteristics of Mercapto Compounds on the Copper Electroplating)

  • 손상기;이유용;조병원;이재봉;이태희
    • 전기화학회지
    • /
    • 제4권4호
    • /
    • pp.160-165
    • /
    • 2001
  • 황산원자를 포함하는 mercapto화합물은 도금시 전착속도를 증가시키는 첨가제로 알려져 있는데, 이 중 4가지의 mercapto 화합물을 선정하여 농도를 변화시켜가며 Hull cell test, Haring-Blum cell test, cathodic polarization, EQCM(Electrochemical Quartz Crystal Microbalance)등을 이용하여 도금특성 및 throwing power를 알아보았다. Cathode polarization 및 EQCM을 통한 구리 전착량을 알아본 결과 4가지의 mercapto 화합물 중 3-mercapto-1-propanesulfonic acid가 activator로서 가장 적당하였으며, 그 농도가 20 ppm에서 throwing power를 증가시키고, 농도 및 활성 과전압이 오직 $Cl^-$만 포함되었을 때보다 cathodic scan시 100 mV 만큼 shift되어 증착속도를 증가시킴을 알 수 있었다.

전기화학적 분극법에 의한 1.0Cr-0.5Mo강의 경년열화 평가에 관한 연구 (A study on the evaluation for material degradation of 0.0Cr-0.5Mo steel by a electrochemical polarization method)

  • 나의균;김훈;이종기
    • 대한기계학회논문집A
    • /
    • 제22권1호
    • /
    • pp.177-189
    • /
    • 1998
  • The contents of this paper include a non-destructive technique for evaluating the degradation of the boiler superheater tube in a fossil power plant through an electrochemical polarization test. Correlation between Ip of polarization parameter and SP-DBTT for the superheater tubes in long-term use was obtained. 1.0Cr-0.5Mo steel was degraded by softening, and the degree of degradation was dependent upon carbides with Cr and Mo elements. Since brittle fracture at low temperature and ductile fracture mode at high temperature were shown, similarity between standard Charpy and small punch tests could be found. In addition, SP-DBTT showing the degree of degradation was higher, as the time-in use of the materials got longer. Electrolyte including picric acid of 1.3 g in distilled water of 100ml at 25.deg. C temperature and sodium tridecylbenzene sulfonate with 1g could be applied to evaluate the degradation of 1.0Cr-0.5Mo steel by means of the electrochemical polarization test. Ip and Ipa values measured through the electrochemical test are the appropriate parameters for representing the degradation of the superheater tube(1.0Cr-0.5Mo steel) for the fossil power plant. It is poassible to evaluate the degradation of materials with different time histories electrochemically, by Ip value only, at field test.

인발률에 따른 자동차 냉각 배관용 Al 합금의 부식 특성에 관한 연구 (Effect of Drawing Rate on the Corrosion Behavior of Al Alloy Tubes for Automotive Cooling System)

  • 박병준;김정구;안승호;곽동호;손현수
    • 대한금속재료학회지
    • /
    • 제46권8호
    • /
    • pp.489-494
    • /
    • 2008
  • The effect of drawing rate on the electrochemical properties of 3003 Al alloys in 5 wt.% NaCl solution was investigated by electrochemical techniques (potentiodynamic polarization test, potentiostatic polarization test, electrochemical impedance spectroscopy (EIS)) and surface analyses (OM, SEM, EDS). Four kinds of automotive pipe materials were prepared (raw material, drawing rate = 5, 10, 15%). As the drawing rate of Al alloy tube increased, the pitting corrosion resistance increased due to the enrichment of Al oxides on the surface.

Ag925의 전기화학적 특성에 미치는 네오디뮴 함량의 영향 (Effect of Neodymium concentration on electrochemical properties of 925 silver)

  • 신병현;정승진;정원섭
    • 한국표면공학회지
    • /
    • 제54권2호
    • /
    • pp.71-76
    • /
    • 2021
  • Ag925, silver with added copper, is popular alloy due to its low price. However, it has a difficult to use because of the low corrosion resistance. In various alloys, neodymium (Nd) works as an element to improve corrosion resistance by reacting with interstitial elements in the alloy. When 1.5 wt. % Neodymium was added to Ag925, the potential on the activated polarization in a potentiodynamic polarization test was increased from -0.15 V to -0.05 V. Ag925 with added neodymium showed the passivation after activation polarization. But When the potential increased around 50 mV, the current density is increased to 3 × 10-3. Ag925 with the 1.5 wt. % Nd had the low corrosion rate.

용접조건에 따른 페라이트 스테인리스강에 대한 수소취성의 전기화학적 분극특성에 관한 연구 (The Study on the Electrochemical Polarization Characteristics of Hydrogen Embrittlement for Ferrite Stainless Steel with Welding Conditions)

  • 최병일;임우조
    • 한국가스학회지
    • /
    • 제9권4호
    • /
    • pp.30-35
    • /
    • 2005
  • 스테인리스 강재 STS444에 있어서 용접조건에 따른 수소취성의 전기화학적 분극특성을 고찰하고자 수소침투 실험과 전기화학적 분극실험을 실시하였다. 즉, $0.5M\; H_2SO_4+0.001M\;As_2O_3$ 수용액 중에서 $1,400kg/cm^2$의 하중을 부가하는 동시에 전기화학적 분극시험 장치로 $30mA/cm^2$전류를 60분간 인가하여 수소를 침투시켰으며 같은 수용액에서 양극분극실험을 하였다. STS444에 있어서 용접조건이 수소취성에 미치는 특성을 연구함에 있어 전보에서는 용접 전 기름이나 물의 흡착 영향으로 인장강도나 연신율이 낮아지는 현상을 규명하였지만, 본보에서는 기존의 보고된 수소취성의 발생 기구를 기초로 하여 전기화학적 부식거동을 접목하여 수소취성의 발생기구를 제안함으로써 부식전류밀도를 알면 수소취성의 민감 정도를 비파괴적으로 예측할 수 있을 것으로 판단된다.

  • PDF