• 제목/요약/키워드: electrochemical phenomenon

검색결과 70건 처리시간 0.026초

고온형 고분자전해질형 연료전지에서의 사형 유로와 평행 유로 성능비교에 대한 수치해석적 연구 (Numerical Study on Comparison of Serpentine and Parallel Flow Channel in High-temperature Proton Exchange Membrane Fuel Cells)

  • 안성하;오경민;주현철
    • 한국수소및신에너지학회논문집
    • /
    • 제29권1호
    • /
    • pp.41-55
    • /
    • 2018
  • General polymer electrolyte fuel cell (PEMFC) operates at less than $80^{\circ}C$. Therefore liquid phase water resulting from electrochemical reaction accumulates and floods the cell which in turn increases the mass transfer loss. To prevent the flooding, it is common to employ serpentine flow channel, which can efficiently export liquid phase water to the outlet. The major drawback of utilizing serpentine flow channel is the large pressure drop that happens between the inlet and outlet. On the other hand, in the high temperature polymer electrolyte fuel cell (HT-PEMFC), since the operating temperature is 130 to $180^{\circ}C$, the generated water is in the state of gas, so the flooding phenomenon is not taken into consideration. In HT-PEMFCs parallel flow channel with lower pressure drop between the inlet and outlet is employed therefore, in order to circulate hydrogen and air in the cell less pumping power is required. In this study we analyzed HT-PEMFC's different flow channels by parallel computation using previously developed 3-D isothermal model. All the flow channels had an active area of $25cm^2$. Also, we numerically compared the performance of HT-PEMFC parallel flow channel with different manifold area and Rib interval against the original serpentine flow channel. Results of the analysis are shown in the form of three-dimensional contour polarization curves, flow characteristics in the channel, current density distribution in the Membrane, overpotential distribution in the catalyst layer, and hydrogen and oxygen concentration distribution. As a result, the performance of a real area fuel cell was predicted.

나피온 폴리머를 이용한 금 전극의 표면 개질 및 이의 삼투압 측정용 임피던스 센서 응용 (Surface Modification of Gold Electrode Using Nafion Polymer and Its Application as an Impedance Sensor for Measuring Osmotic Pressure)

  • 길민식;김민재;윤조희;장진우;이경균;최봉길
    • 공업화학
    • /
    • 제34권1호
    • /
    • pp.9-14
    • /
    • 2023
  • 본 논문에서는 용액의 이온 농도 측정이 가능한 나피온 폴리머(Nafion polymer) 코팅 기반 2상 금 전극의 임피던스(Impedance) 센서를 개발하였다. 스퍼터링(Sputtering) 공정을 통해서 제작된 금 전극의 표면을 나피온 폴리머를 사용하여 표면 개질 하였다. 상기 제작된 전극은 분극 현상 제어가 가능하여 전기화학적 신호를 안정적으로 측정할 수 있도록 하였다. 분광학과 전자주사현미경 관찰을 통하여 박막의 나피온 폴리머 코팅을 확인하였다. 나피온 코팅이 된 전극은 기존 금 전극에 비해 안정적인 임피던스 신호를 보여 주었으며, 표준 염화나트륨(NaCl) 용액 사용 시 임피던스 센서의 신뢰성 높은 검정 곡선(R2 = 0.983)을 나타내었다. 또한, 임피던스 센서는 상용화 전도도 장치와 인공 눈물의 이온 농도 측정 비교 실험을 진행하였으며, 유사한 결과값을 확인하였다.

막다른 미세유로 내부의 농축 동역학 분석 (Analysis of Preconcentration Dynamics inside Dead-end Microchannel)

  • 이효민
    • Korean Chemical Engineering Research
    • /
    • 제61권1호
    • /
    • pp.155-161
    • /
    • 2023
  • 이온 농도 분극 현상은 전기투석, 전기화학 전지에서 일어나는 기초 이동 현상일 뿐만 아니라, 생체 물질 전처리용 농축 장치의 핵심 기작으로 활용된다. 외부 인가 전압에 의해 발생한 이온 농도 분극 현상은 분석 물질의 농축에 필요한 국소적으로 증폭된 전기장을 통해 물질의 농축을 가능케 한다. 그러나 기존의 농축 기작은 농축의 평형 지점이 불분명하며, 농축 플러그의 유체역학적 불안정성의 두가지 문제점을 가지고 있다. 본 연구에서는, 이온 농도 분극 기반의 농축 기작의 한계점을 해결하기 위해 막다른 미세유로와 양이온 교환막을 사용한 농축 방법을 연구하였다. 막다른 미세유로의 공간 제약적 구조를 통해 유체역학적 안정성을 확보할 수 있으며, 분석 물질의 농축 지점이 이온 공핍 영역의 충격 전단과 일치함을 수치적으로 확인하였다. 또한 농축 공정의 핵심 인자로써 인가 전압과 미세유로의 체적 전하 농도를 변화시켜가며, 농축 물질의 전기동역학적 거동을 연구하였다. 본 연구의 결과는 현장 진단 검사(point-of-care)와 같은 초단시간의 농축을 필요로 하는 미세유체역학 장치에 유효한 기작으로 사용될 수 있을 것이다.

폴리아크릴로니트릴 기반 3D 탄소나노섬유 스펀지의 제조 및 오일 흡착 특성 (Preparation and Oil Absorption Properties of PAN Based 3D Shaped Carbon Nanofiber Sponge )

  • 주혜원;강진혁;박종호;고재경;국윤수;남창우;김병석
    • Composites Research
    • /
    • 제36권3호
    • /
    • pp.217-223
    • /
    • 2023
  • 본 연구에서는 폴리아크릴로니트릴계 탄소나노섬유 스펀지의 제조 및 오일 흡착 거동을 조사하였다. 제조된 탄소나노섬유 스펀지는 물과 기름의 혼합용액에서 우수한 선택적 오일 흡착 능력을 보였으며, 탄소나노섬유 스펀지의 재사용시 흡착 능력도 확인하였다. 또한, 흡착제 내부구조에 정렬된 채널을 형성함으로써, 모세관 현상에 의하여 빠른 오일 흡착 거동을 보이는 탄소나노섬유 스펀지를 제조할 수 있었다. 이후 사용 폐기된 탄소나노섬유 스펀지는 질소 분위기에서 800℃로 열처리하여, 4-아미노페놀의 전기화학적 검출을 위한 센서로의 가능성을 검토하였다.

탄화수소계 고분자-실리카 복합막이 적용된 연료전지 스택 성능평가 (Characterization of Fuel Cell Stack Using Hydrocarbon Polymer-Silica Composite Membranes)

  • 강현우;황두성;박치훈;이영무
    • 멤브레인
    • /
    • 제33권3호
    • /
    • pp.127-136
    • /
    • 2023
  • 본 연구에서는 실리카 복합막 기반 고분자 전해질막을 5단 연료전지 스택에 적용하여 성능 평가를 수행하였다. 이를 통하여, 개별 구성 요소의 성능도 중요하지만, 전체적인 관점에서 공급되는 연료의 유량이 스택 성능에 중요한 역할을 하며, 특히 수소의 유량에 크게 의존한다는 사실이 확인하였다. 산소의 유량을 증가시켜도 성능의 변화는 미미한 반면, 수소의 유량을 증가시키면 성능이 향상되는 것을 확인하였다. 그러나 수소의 유량 증가는 수소와 산소 유량 비율의 불균형을 초래하여 장기적으로는 스택 성능과 내구성을 저하시키는 문제가 관찰되었다. 이러한 현상을 스택 구성 요소 및 개별 단위 셀에서도 관찰할 수 있었으며, 따라서 스택 운전 시 각 구성 요소의 성능을 최적화하는 것 외에도 균일한 유량 제어를 위해 유로 설계 및 운전 조건을 최적화하는 것이 중요하다는 것을 알 수 있었다. 마지막으로 실리카 복합막은 최대 출력 기준 25 W 이상의 성능을 나타내어 실제 연료전지 시스템에 적용하기에 충분한 성능을 갖춘 것으로 판단된다.

수소 장입 장치를 활용한 액체수소 저장시스템 강재의 CTOD 시험 분석 (Analysis of CTOD Tests on Steels for Liquefied Hydrogen Storage Systems Using Hydrogen Charging Apparatus)

  • 성기영;김정현;이정희;이정원
    • 한국산업융합학회 논문집
    • /
    • 제26권5호
    • /
    • pp.875-884
    • /
    • 2023
  • Hydrogen infiltration into metals has been reported to induce alterations in their mechanical properties under load. In this study, we conducted CTOD (Crack Tip Opening Displacement) tests on steel specimens designed for use in liquid hydrogen storage systems. Electrochemical hydrogen charging was performed using both FCC series austenitic stainless steel and BCC series structural steel specimens, while CTOD testing was carried out using a 500kN-class material testing machine. Results indicate a notable divergence in behavior: SS400 test samples exhibited a higher susceptibility to failure compared to austenitic stainless steel counterparts, whereas SUS 316L test samples displayed minimal changes in displacement and maximum load due to hydrogen charging. However, SEM (Scanning Electron Microscopy) analysis results presented challenges in clearly explaining the mechanical degradation phenomenon in the tested materials. This study's resultant database holds significant promise for enhancing the safety design of liquid hydrogen storage systems, providing invaluable insights into the performance of various steel alloys under the influence of hydrogen embrittlement.

전기화학적 기법에 의한 미생물연료전지 내부저항 특성 파악 및 전력관리시스템 연계 전압 변화와 유기물 저감에 미치는 영향 (Identification of Internal Resistance of Microbial Fuel Cell by Electrochemical Technique and Its Effect on Voltage Change and Organic Matter Reduction Associated with Power Management System)

  • 장재경;박혜민;김태영;양윤석;여정진;강석원;백이;권진경
    • 대한의용생체공학회:의공학회지
    • /
    • 제39권5호
    • /
    • pp.220-228
    • /
    • 2018
  • The internal resistance of microbial fuel cell (MFC) using stainless steel skein for oxidizing electrode was investigated and the factors affecting the voltage generation were identified. We also investigated the effect of power management system (PMS) on the usability for MFC and the removal efficiency of organic pollutants. The performance of a stack microbial fuel cell connected with (PMS) or PMS+LED was analyzed by the voltage generation and organic matter reduction. The maximum power density of the unit cells was found to be $5.82W/m^3$ at $200{\Omega}$. The maximum current density was $47.53A/m^3$ without power overshoot even under $1{\Omega}$. The ohmic resistance ($R_s$) and the charge transfer resistance ($R_{ct}$) of the oxidation electrode using stainless steel skein electrode, were $0.56{\Omega}$ and $0.02{\Omega}$, respectively. However, the sum of internal resistance for reduction electrode using graphite felts loaded Pt/C catalyst was $6.64{\Omega}$. Also, in order to understand the internal resistance, the current interruption method was used by changing the external resistance as $50{\Omega}$, $300{\Omega}$, $5k{\Omega}$. It has been shown that the ohm resistance ($R_s$) decreased with the external resistance. In the case of a series-connected microbial fuel cell, the reversal phenomenon occurred even though two cells having the similar performance. However, the output of the PMS constantly remained for 20 hours even when voltage reversal occurred. Also the removal ability of organic pollutants (SCOD) was not reduced. As a result of this study, it was found that buffering effect for a certain period of time when the voltage reversal occurred during the operation of the microbial fuel cell did not have a serious effect on the energy loss or the operation of the microbial fuel cell.

다상유동 전산모사를 통한 공학 규모의 cathode processor의 성능평가 (Performance Evaluation to Develop an Engineering Scale Cathode Processor by Multiphase Numerical Analysis)

  • 유병욱;박성빈;권상운;김정국;이한수;김인태;이종현
    • 방사성폐기물학회지
    • /
    • 제12권1호
    • /
    • pp.7-17
    • /
    • 2014
  • 용융염 전해정련공정은 사용후핵연료로부터 전기화학적인 방법을 통해 음극에서 우라늄을 회수 하는 공정이다. 이 때 우라늄은 약 30wt%의 염을 포함하고 있어 순수한 우라늄을 얻기 위해서는 염을 제거하는 Cathode Process (CP)가 필수적이다. CP는 대량의 우라늄을 처리해야 하므로 파이로공정의 난관중의 하나로 인식되고 있으며, 우라늄의 순도가 최종적으로 결정되는 단계이므로 매우 중요한 공정이다. 현재, 이에 대한 연구는 주로 실험적 방법에 근거 하고 있어 염 제거 공정 중 온도, 압력, 염 가스의 거동을 관찰하기 어렵다. 따라서 본 연구에서는, 공정의 운전 조건에 대해 적합한 수학적 모델을 이용하여 전산모사 해석을 진행하였다. 본 연구는 증류부에서 염 가스의 증류 량, 확산계수에 의해 계산된 장치 내 염 가스의 이동 그리고 응축부에서의 응결속도를 중점적으로 연구하였다. 장치내의 각각의 염 가스 거동을 정의하기 위해 Hertz-Langmuir 관계식, Chapman-Enskog Theory, ANSYS-CFX의 상용 코드를 사용하였다. 그리고 HSC Chemistry에서 염의 물성 값을 이용하여 모델을 구성하였다. 본 연구의 전산모사 해석을 통해 얻은 연구 결과를 이용하여 염 가스의 거동과 장치의 최적 운전조건을 예측하였다. 따라서 본 해석 결과는 CP의 물리적 현상을 깊게 이해하는데 쓰일 뿐 아니라, 공학규모의 CP 장치를 상용규모로 확장하는데 이용 할 수 있다.

졸-겔법으로 제조된 비정질의 텅스텐 산화물 박막과 황산 전해질 계면에서 일어나는 수소의 층간 반응에 대한 전기화학적 특성 (Electrochemical Characteristic on Hydrogen Intercalation into the Interface between Electrolyte of the 0.1N H2SO4and Amorphous Tungsten Oxides Thin Film Fabricated by Sol-Gel Method)

  • 강태혁;민병철;주재백;손태원;조원일
    • 공업화학
    • /
    • 제7권6호
    • /
    • pp.1078-1086
    • /
    • 1996
  • 본 연구에서는 W-IPA(peroxo-polytungstic acid)를 출발 물질로 하는 졸 용액을 ITO(indium tin oxide)가 입혀진 유리판 위에 침적 도포(dip-coating) 방법으로 침적시키고, 이것을 겔화시킨 후에 열처리하여 전기 발색 소자 (electrochromic device, ECD)의 텅스텐 산화물 박막 전극을 만들어 이의 전기화학적인 특성을 고찰하였다. 가장 좋은 전기 화학적 특성을 나타내는 조건은 $2g/10mL(W-IPA/H_2O)$졸 용액에 15회 침적 도포하여 $230{\sim}240^{\circ}C$의 온도로 최종 열처리 한 텅스텐 산화물 박막 전극이었으며, 침적 횟수의 증가에 따라 산화 텅스텐 박막의 두께는 비례하여 증가하였고, 5회 침적 도포 이후에는 1회 침적 도포시 약 $60{\AA}$ 두께로 막이 생성됨을 알 수 있었다. 졸-겔법으로 제조된 텅스텐 산화물 박막 전극은 X-선 회절 분석에 의하여 비정질 구조, 주사 전자 현미경에 의하여 박막 표면은 균일한 것으로 조사되었다. 다중 순환 전류-전위 주사법에 의하여 작성된 전류-전위 곡선에 의하면 순환 횟수가 수백회 이상임에도 불구하고 소 발색은 뚜렷하게 나타났으나, 더욱 많은 순환 횟수에서는 전해질인 황산 수용액 중에서 텅스텐 산화물 박막의 박리 현상이 일어나 소 발색의 전류 밀도는 차츰 감소하였다. 전위 주사 속도를 변화시키면서 순환 전류-전위 주사법에 의하여 작성된 전류-전위 곡선으로부터 구한 전기화학적 특성 값을 이용하여 반응에 참여하는 수소 이온의 확산 계수를 구할 수 있었다.

  • PDF

법랑질 변연으로 이루어진 복합레진 수복물의 체적과 C-factor가 미세누출에 미치는 영향 (THE EFFECT OF C-FACTOR AND VOLUME ON MICROLEAKAGE OF COMPOSITE RESIN RESTORATIONS WITH ENAMEL MARGINS)

  • 구봉주;신동훈
    • Restorative Dentistry and Endodontics
    • /
    • 제31권6호
    • /
    • pp.452-459
    • /
    • 2006
  • 와동벽과 복합레진 수복물이 접착될 때, 복합레진의 치질에 대한 접착력과 레진 자체의 중합 시 발생하는 수축응력이 상충하게 된다. 이러한 수축응력의 크기는 와동의 형태요소 (C-factor)와 수복물의 체적에 영향을 받는다. 이에 본 실험에서는 단일 병 접착제를 사용한 복합레진 수복 시 법랑질 변연만으로 이루어진 와동의 C-factor와 체적이 미세누출에 미치는 영향을 미세 전류 측정법을 이용하여 정량적으로 분석하고 평가하였다. 연마기를 이용하여 40개의 건전한 우치 협면에 편평한 법랑질 표면을 형성하였다. 각각 10개의 치아에 원통형 와동을 형성하였으며, 와동의 깊이와 직경에 따라 4개 군으로 분류하였다 ( I군: 1.5 mm ${\times}$ 2.0 mm, II군: 1.5 mm ${\times}$ 6.0 mm, III군: 2.0 mm ${\times}$ 1.72 mm, IV군: 2.0 mm ${\times}$ 5.23 mm). 각기 와동의 C-factor는 4, 5.62, 2, 2.54를 보였다. 산 부식 후 단일 병 접착제인 BC Plus$^{TM}$ (Vericom, Korea)를 제조사의 지시에 따라 적용하고, 미세혼합형 복합레진인 Denfil$^{TM}$(Vericom)을 충전하였다. 40초씩 광중합 후 치아를 실온에서 증류수에 24시간 동안 보관한 다음, Sof-Lex system을 이용하여 연마하였고, 5$^{\circ}$C와 55$^{\circ}$C범위에서 500회 열순환을 시행하였다. 이후 미세전류 측정을 위해 치수강 내에 증류수를 채우고 치근단공을 통해 0.018 stainless wire를 삽입한 후 sticky wax로 근첨부를 밀봉하였으며, nail varnish를 수복물의 변연에서 1 mm를 제외한 전체 치면에 2회 도포하였다. 미세누출의 측정은 전기 화학적 방법을 이용하여 측정하였으며, 통계적 유의성은 95% 유의 수준의 Two-way ANOVA로 검증하여 , 다음과 같은 결과를 얻었다. 1. 복합레진 수복물의 체적이 적은 것이 큰 것에 비해 미세누출도가 적었으나, 통계학적으로 유의한 차이는 없었다. 2. 와동 형태와 연관된 C-factor는 복합레진 수복물의 미세누출도에 영향을 주지 않았다. 법랑질 변연을 갖는 와동에 단일 병 접착제를 사용한 본 실험에서는 복합레진의 중합 시 발생하는 수축응력에 영향을 미치는 것으로 알려진 수복물의 체적과 C-factor가 미세누출도에 영향을 주지 못하였다. 이는 법랑질과 접착시스템과의 강력한 접착력에 기인한 것으로 보이며, 앞으로 이에 대한 더 많은 연구가 필요할 것으로 사료된다.