• Title/Summary/Keyword: electrocardiography (ECG)

Search Result 80, Processing Time 0.029 seconds

Estimated Action Potentials During Repolarization Phase form the Body Surface Electrocardiogram (심전도의 재분극상에서의 활동전임의 추정)

  • Kang, Hoon;Min, Byoung-Goo;Choi, Keh-Kun
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.20 no.6
    • /
    • pp.81-87
    • /
    • 1983
  • The body surface ECG(electrocardiogram) is produced by the electric fields caused by the propagation of action potentials within the myocardial cells. The repolarization phase of the action potential is very sensitive to factors of clinical importance. Therefore, in this paper of the inverse electrocardiography, we studied a method of estimating the uniform action potentials during repolarization phase from the body surface ECG using digital signal identification techniques. The estimated action potential of a normal was similar to that of clinical data in the repolarization phase.

  • PDF

A Preliminary Study of Pulse Measurement Estimation Using Textile Proximity Sensor (섬유근접센서를 이용한 맥박 측정 평가의 기초연구)

  • Ho, JongGab;Wang, Changwon;Jung, HwaYoung;Na, Ye-Ji;Lee, Sangjoon;Min, Se Dong
    • Annual Conference of KIPS
    • /
    • 2016.04a
    • /
    • pp.865-867
    • /
    • 2016
  • 본 논문에서는 섬유근접센서를 이용하여 측정한 맥박을 평가하기 위해 Biopac MP150에서 획득한 Electrocardiography(ECG)와의 관계를 보았다. 섬유근접센서는 요골동맥에서의 맥박을 측정하기 위해 $5{\times}5$ 크기로 설계하였고, 전처리 과정과 필터링을 거쳐 획득한 데이터 값은 ECG 데이터와 Peak Point의 개수를 비교하여 올바른 맥박이 측정되었는지를 판단하였다. 그 결과 섬유근접센서와 MP150에서 측정한 두 데이터의 Peak Point가 모두 동일한 결과를 보였다.

Implementation of Biosignal Mornitoring System for u-Health (유헬스를 위한 생체신호 모니터링 시스템의 구현)

  • Kim, Kyung Ho;Park, Ji Ho;Park, Young Sik;Hwang, Yu Min;Kim, Jin Young
    • Journal of Satellite, Information and Communications
    • /
    • v.9 no.2
    • /
    • pp.80-84
    • /
    • 2014
  • As an integrated technology with IT and biomedical sciences, U-health offers various healthcare services without time and space limit. In order to make a proper diagnosis, doctors need two key technologies: biosignal measurement and high reliability communication technologies. In this paper, we introduce an implementation process of a bio signal system with using an electrocardiography(ECG) sensor, video, global positioning system(GPS), communication module and micro controller unit(MCU).

Premature Contraction Arrhythmia Classification through ECG Pattern Analysis and Template Threshold (ECG 패턴 분석과 템플릿 문턱값을 통한 조기수축 부정맥분류)

  • Cho, Ik-sung;Cho, Young-Chang;Kwon, Hyeog-soong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.2
    • /
    • pp.437-444
    • /
    • 2016
  • Most methods for detecting arrhythmia require pp interval, diversity of P wave morphology, but it is difficult to detect the p wave signal because of various noise types. Therefore it is necessary to use noise-free R wave. In this paper, we propose algorithm for premature contraction arrhythmia classification through ECG pattern analysis and template threshold. For this purpose, we detected R wave through the preprocessing method using morphological filter, subtractive operation method. Also, we developed algorithm to classify premature contraction wave pattern using weighted average, premature ventricular contraction(PVC) and atrial premature contraction(APC) through template threshold for R wave amplitude. The performance of R wave detection, PVC classification is evaluated by using 6 record of MIT-BIH arrhythmia database that included over 30 PVC and APC. The achieved scores indicate the average of 99.77% in R wave detection and the rate of 94.91%, 95.76% in PVC and APC classification.

Biochemical, Hematological, and Electrocardiographic Changes in Buffaloes Naturally Infected with Theileria annulata

  • Hasanpour, A.;Moghaddam, G.A.;Nematollahi, Ahmad
    • Parasites, Hosts and Diseases
    • /
    • v.46 no.4
    • /
    • pp.223-227
    • /
    • 2008
  • Changes in selected blood and serum components and electrocardiography (ECG) were investigated in 20 adults (13 females and 7 males) of water buffaloes suffering from severe theileriosis. The age of all animals used in this study ranged 1.5-5yr. Theileriosis was diagnosed by observation of parasites in the peripheral blood and the presence of schizonts in lymphocytes that were provided from swollen lymph nodes. Statistically significant decreases were observed in the means of RBC, WBC, and packed cell volume (PCV) in blood of infected animals. The means levels of sodium, calcium, phosphorus, and potassium of infected animals were lower than healthy animals, but only the decrease of potassium was significant. The mean serum activities of aspartate transferase and alanine aminotransfrase were significantly higher than in un infected animals. Three cases had atrial premature beat, 2 cases had sinus tachycardia, 2 had sinus arrhythmia, and 1 had first degree of atrioventricular block in ECG. The present study showed that T. annulata infection in cattle is associated with hematological and biochemical, and ECG changes.

The Determination of the Duration of Electroconvulsive Therapy-Induced Seizure Using Local Standard Deviation of the Electroencephalogram Signal and the Changes of the RR Interval of Electrocardiogram

  • Kim, Eun Young;Yoo, Cheol Seung;Jung, Dong Chung;Yi, Sang Hoon;Chung, In-Won;Kim, Yong Sik;Ahn, Yong Min
    • Korean Journal of Biological Psychiatry
    • /
    • v.27 no.1
    • /
    • pp.1-8
    • /
    • 2020
  • Objectives In electroconvulsive therapy (ECT) research and practice, the precise determination of seizure duration is important in the evaluation of clinical relevance of the ECT-induced seizure. In this study, we have developed computerized algorithms to assess the duration of ECT-induced seizure. Methods Subjects included 5 males and 6 females, with the mean age of 33.1 years. Total 55 ECT sessions were included in the analysis. We analyzed the standard deviation of a finite block of electroencephalography (EEG) data and the change in the local slope of RR intervals in electrocardiography (ECG) signals during ECT-induced seizure. And then, we compared the calculated seizure durations from EEG recording (EEG algorithm) and ECG recording (ECG algorithm) with values determined by consensus of clinicians based on the recorded EEG (EEG consensus), as a gold standard criterion, in order to testify the computational validity of our algorithms. Results The mean seizure durations calculated by each method were not significantly different in sessions with abrupt flattened postictal suppression and in sessions with non-abrupt flattened postictal suppression. The intraclass correlation coefficients (95% confidence interval) of the three methods (EEG algorithm, ECG algorithm, EEG consensus) were significant in the total sessions [0.79 (0.70-0.86)], the abrupt flattened postictal suppression sessions [0.84 (0.74-0.91)], and the non-abrupt flattened postictal suppression sessions [0.67 (0.45-0.84)]. Correlations between three methods were also statistically significant, regardless of abruptness of transition. Conclusions Our proposed algorithms could reliably measure the duration of ECT-induced seizure, even in sessions with non-abrupt transitions to flat postictal suppression, in which it is typically difficult to determine the seizure duration.

Efficiency of MVP ECG Risk Score for Prediction of Long-Term Atrial Fibrillation in Patients With ICD for Heart Failure With Reduced Ejection Fraction

  • Levent Pay;Ahmet Cagdas Yumurtas;Ozan Tezen;Tugba Cetin;Semih Eren;Goksel Cinier;Mert Ilker Hayiroglu;Ahmet Ilker Tekkesin
    • Korean Circulation Journal
    • /
    • v.53 no.9
    • /
    • pp.621-631
    • /
    • 2023
  • Background and Objectives: The morphology-voltage-P-wave duration (MVP) electrocardiography (ECG) risk score is a newly defined scoring system that has recently been used for atrial fibrillation (AF) prediction. The aim of this study was to evaluate the ability of the MVP ECG risk score to predict AF in patients with an implantable cardioverter defibrillator (ICD) and heart failure with reduced ejection fraction in long-term follow-up. Methods: The study used a single-center, and retrospective design. The study included 328 patients who underwent ICD implantation in our hospital between January 2010 and April 2021, diagnosed with heart failure. The patients were divided into low, intermediate and high-risk categories according to the MVP ECG risk scores. The long-term development of atrial fibrillation was compared among these 3 groups. Results: The low-risk group included 191 patients, the intermediate-risk group 114 patients, and the high-risk group 23 patients. The long-term AF development rate was 12.0% in the low-risk group, 21.9% in the intermediate risk group, and 78.3% in the high-risk group. Patients in the high-risk group were found to have 5.2 times higher rates of long-term AF occurrence compared to low-risk group. Conclusions: The MVP ECG risk score, which is an inexpensive, simple and easily accessible tool, was found to be a significant predictor of the development of AF in the long-term follow-up of patients with an ICD with heart failure with reduced ejection fraction. This risk score may be used to identify patients who require close follow-up for development and management of AF.

Bio-Medical Data Transmission System using Multi-level Visible Light based on Resistor Ladder Circuit (저항 사다리 회로 기반의 다중레벨 가시광을 이용하는 의료 데이터 전송 시스템)

  • An, Jinyoung;Chung, Wan-Young
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.131-137
    • /
    • 2016
  • In this study, a multilevel visible light communication (VLC) system based on resistor ladder circuit is designed to transmit medical data. VLC technology is being considered as an alternative wireless communication due to various advantages such as ubiquity, license free operation, low energy consumption, and no radio frequency (RF) radiation characteristics. With VLC even in places where traditional RF communication (e.g., Wi-Fi) is forbidden, significant bio-medical signal including the electrocardiography (ECG) and photoplethysmography (PPG) data can be transmitted. More lives could be saved anywhere by this potential advantage of VLC with a fast emergency response time. A multilevel transmission scheme is adopted to improve the data capacity with keeping simplicity, where data transmission rate can increase by log2m times (m is the number of voltage levels) than that of conventional VLC transmission based on on/off keying. In order to generate multi-amplitudes, resistor ladder circuit, which is a basic principle of digital to analog convertor, is employed, and information is transferred through LED (Light-Emitting Diode) with different voltage level. In the receiver side, multilevel signal is detected by optical receiver including a photo diode. Then, the collected data are analyzed to serve the necessary medical care to the concerned patient.

Electrocardiographic Findings in School Children (국민학생 및 중학생의 심전도 소견)

  • Jun, Jin-Gon;Kim, Jeong-Lan;Park, Jae-Hong
    • Journal of Yeungnam Medical Science
    • /
    • v.4 no.2
    • /
    • pp.23-27
    • /
    • 1987
  • Mass electrocardiographic (ECG) examination was performed on 13,801 children (male 7,526 and female 6,275) of elementary and middle school in Taegu from May 1. 1986. to April 30. 1987. We read their ECG according to the "Pediatric Electrocardiography." The results were as following; The Incidence of ECG abnormality was 1.05%(male 1.3% and female 0.75%). Fifty eight children (0.42%) had atrial and ventricular hypertrophy; two right atrial hypertrophy, five left atrial hypertrophy, thirty five fight ventricular hypertrophy and sixteen left ventricular hypertrophy respectively. Ectopic beats occurred in 25 children (0.18%) ; They were atrial in 12 children, ventricular in 8 children and junctional in 5 children. There were 62 children (0.45%) of conduction disturbance ; They were first degree atrioventricular (A-V) block in 21 children, type I second degree A-V block in 1 child, A-V dissociation in 1 child, right bundle branch block in 36 children, left bundle branch block in 1 child and WPW syndrome in 2 children. Nonspecific ST, T changes and sinus tachycardia were found in 3 and one children respectively.

  • PDF

A Study on Performance Evaluation for Electrocardiography Signal Measurement Electrode based on Conductive Fabric (전도성 섬유 기반 심전도 전극의 성능 평가에 관한 연구)

  • Kang, Bo Kyu;Yoo, Sun Kook
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.2
    • /
    • pp.210-220
    • /
    • 2013
  • Recently, as we move toward a society with an increasingly aged population, wearable U-health devices in various shapes with smart wear have been developed in order to conveniently measure health variables without using hands in daily life or at home. However, the problem is that only supply of the wearable U-health devices is focused and its applicable devices are studied and developed, which has resulted in lack of awareness of importance of performance evaluation. In this study, two electrodes were fabricated using conductive fabric which can be used as electrode if attached to wearable U-health devices or smart wear in order to measure ECG signal. Two electrodes those were fabricated using conductive fabric were compared the correlation, impedance and CMRR with patch typed Ag-AgCl electrode-normally used for measurement of ECG signal, so that the study would find out if the fabricated electrode can be used with the wearable U-health devices by testing and evaluating performances.