• Title/Summary/Keyword: electrocardiogram

Search Result 628, Processing Time 0.023 seconds

Analysis of Electroencephalogram and Electrocardiogram at an Acupoint PC9 during Pulsed Magnetic Field Stimulus

  • Lee, Jin-Yong;Hwang, Do-Gwen;Yoo, Jun-Sang;Lee, Hyun-Sook
    • Journal of Magnetics
    • /
    • v.17 no.2
    • /
    • pp.133-137
    • /
    • 2012
  • We investigated the effects of pulsed magnetic fields (PMF) stimulus on electroencephalogram (EEG) alpha activity and heart rate variability (HRV) from electrocardiogram (ECG) measurements with various stimulus durations at acupoint PC9. The alpha activity in the EEG and the ratio of low frequency power and high frequency power (LHR) in the HRV, a reflection of sympathovagal activity, were increased and decreased, respectively, after PMF stimulus of 3 min. Our spectral analysis quantitatively proved that the changes in the EEG alpha activity were consistent with an autonomic function in the ECG. These findings suggest that appropriate PMF stimulus results in the same effect as that of acupuncture applied to the acupoint PC9, which is closely related to the parasympathetic activity of the autonomic nervous system.

Protective effect of green tea extract on doxorubicin induced cardiotoxicity in rats

  • Patil, Leena;Balaraman, R.
    • Advances in Traditional Medicine
    • /
    • v.5 no.2
    • /
    • pp.137-143
    • /
    • 2005
  • Doxorubicin induces oxidative stress leading to cardiotoxicity causing electrocardiogram abnormalities and increases in biomarkers associated with toxicity. Green tea extract (GTE) is reported to possess antioxidant activity mainly via its polyphenolic constituent, catechins. This study was intended to determine the effect of various doses of GTE (25, 50 and 100 mg/kg/day p.o. for 30 days) on doxorubicin-induced electrocardiographic and biochemical changes in rat heart. The latter included lactate dehydrogenase, creatine kinase, and glutamic oxaloacetate transaminase in serum and superoxide dismutase, catalase, and reduced glutathione, as well as membrane bound enzymes like $Na^+K^+ATPase,\;Ca^{2+}ATPase,\;Mg^{2+}ATPase$ and decreased lipid peroxidation in heart tissue Results demonstrated that rats which received GTE were less susceptible to such changes indicating protection afforded by GTE.

2D ECG Compression Method Using Sorting and Mean Normalization (정렬과 평균 정규화를 이용한 2D ECG 신호 압축 방법)

  • Lee, Gyu-Bong;Joo, Young-Bok;Han, Chan-Ho;Huh, Kyung-Moo;Park, Kil-Houm
    • Proceedings of the IEEK Conference
    • /
    • 2009.05a
    • /
    • pp.193-195
    • /
    • 2009
  • In this paper, we propose an effective compression method for electrocardiogram(ECG) signals. 1-D ECG signals are reconstructed to 2-D ECG data by period and complexity sorting schemes with image compression techniques to Increase inter and intra-beat correlation. The proposed method added block division and mean-period normalization techniques on top of conventional 2-D data ECG compression methods. JPEG 2000 is chosen for compression of 2-D ECG data. Standard MIT-BIH arrhythmia database is used for evaluation and experiment. The results show that the proposed method outperforms compared to the most recent literature especially in case of high compression rate.

  • PDF

The vision thresholds of nigro (Cichlasoma nigrofasciatum) on white LED light through ECG analysis (심전도 분석을 통한 백색 LED광에 대한 니그로 (Cichlasoma nigrofasciatum)의 시각역치)

  • HEO, Min-A;KIM, Min-Son;SHIN, Hyeon-Ok
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.52 no.1
    • /
    • pp.42-47
    • /
    • 2016
  • This study was conducted to investigate visual threshold of nigro (Cichlasoma nigrofasciatum) on white LED light. The visual threshold was obtained by analyzing electrocardiogram (ECG) of the nigro. 5 individuals (body weight: 15.62~45.49 g; TL: 8.9~12.4 cm) were trained for lights by an electric stimulus. And then the heart rate (beats/10s) before and after switching on the light were compared. Light intensity range was from 0.00 to 226.4 lux. Average heart rate was 10.36 beats/10s in the normal condition. When the fish perceived the light, the heart rate was decreased. Visual threshold of the fish was 2.59 lux.

Systematic Diagnosis and Long-term Care of Cardiopulmonary Disease (심폐기 질환의 체계적인 진단과 장기-치료 관찰)

  • 김재웅
    • The Korean Journal of Food And Nutrition
    • /
    • v.11 no.2
    • /
    • pp.171-178
    • /
    • 1998
  • K14 patient with chronic dyspnea, who is senile female, early had suffered from radical mastectomy, radiotherapy, autoplastic transplantation, and knee arthritis. Abnormalities of cardiopulmonary function such as obesita, hypertension, mild left ventricular hypertrophy, and chronic pulmonary disease were found from K14 patient's clinical datas, which based on medical history and diagnosis, as well as evaluation of blood pressure, obesity, clinical diagnosis, chest PA, electrocardiogram, ultrasonocardiograph, and spirometery test. Diagnostic results were exactly analyzed, also long-term cares of K14 patient were discussed with related to the clinical literatures.

  • PDF

A Simple Algorithm for Measuring the Position and Time Interval of the ECG Wave Components (ECG 파형 성분의 위치와 time interval 측정알고리즘)

  • 이명호;윤형로
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.53-62
    • /
    • 1985
  • The position and time interval of wave components of the electrocardiogram are used as important data for physician's diagnosis. In case of using the existing definition of the onset of the wave component of the electrocardiogram, they have some problems of defining the precise position of the isoelectric line, of defining the limit of the gradient accepted as the onset, and of the gradient being changed by noise. Therefore, in this paper all time intervals and positions of wave components needed for data of diagnosis were obtained correctly by turning point data reduction algorithm and linear regression intersection algorithm, and the viability of the method of intersecting lines was established in comparison to the four methods of calculating the PR interval.

  • PDF

A Study on Plantar Electrocardiogram Measurement Using a Conductive Textile (전도성 섬유를 이용한 발바닥 심전도 측정에 관한 연구)

  • Yoo, Soo-Han;Lee, Yoo-Jung;Im, Do Hwi;Jung, Hwa-Yung;Wang, Changwon;Min, Se Dong
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2016.04a
    • /
    • pp.887-889
    • /
    • 2016
  • 본 연구는 전도성 섬유를 양말에 부착하여 발바닥에서 심전도(ECG, Electrocardiogram) 신호를 검출하였다. 발바닥에서 측정한 심전도 신호와 손목에서 측정한 심전도 신호에 Pan-Tompkins algorithm을 적용하였고 R-R interval을 검출하였다. 이후 발바닥과 손목에서 측정된 심전도의 유의성을 검출하기 위해 비모수 검정법인 Spearman검정을 사용하여 상관분석을 수행하였다. 상관분석 결과, 유의확률 p=0.00에서 correlation coefficient=0.901로 두 데이터는 강한 양의 선형 관계에 있는 것으로 나타났다.

A Study of Biosignal Analysis System for Sensibility Evaluation (감성을 평가하기 위한 생체신호 분석 시스템에 관한 연구)

  • Lee, Ji-Hyeoung;Kim, Kyung-Ho
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2010.07a
    • /
    • pp.35-38
    • /
    • 2010
  • 본 논문에서는 일상생활 속에서 무자각적으로 생체신호를 측정하고 분석하여 감성을 평가할 수 있는 임베디드 시스템에 관하여 연구하였다. 지속적으로 변화하는 감성을 일관적이며 신뢰성이 높은 생리적인 방법으로 평가하기 위해 심전도(ECG:Electrocardiogram), 맥파(PPG:Photoplethysmogram)의 두 가지 생체신호를 측정하고, 무선전송(Bluetooth) 장치를 이용하여 측정한 생체신호를 실시간으로 노트북PC로 전송하여 분석하였다. 생체신호의 분석방법은 FFT(Fast Fourier Transform)과 전력스펙트럼밀도(Power Spectrum Density)를 이용한 주파수 분석방법으로 두 생체신호의 특정 주파수 대역이 가지는 자율신경계의 활성도의 비율을 분석하여 비교 연구하였다. 또한 보다 빠르고 정확한 감성을 평가하기 위하여 분석알고리즘의 연산을 최소화 하였으며 그래프를 이용한 분석결과의 시각화를 하였다. 본 논문에서는 무자각적인 생체신호 측정 시스템을 이용하여 다양한 상황에서 생체신호를 측정하고, 개발한 분석 알고리즘으로 분석한 결과의 차이를 연구하여 정확도 및 신뢰도를 기준으로 감성을 평가하기 위한 분석 시스템을 평가하였다.

  • PDF

Compression of Electrocardiogram Using MPE-LPC (MPE-LPC를 이용한 심전도 신호의 압축)

  • 이태진;김원기;차일환;윤대희
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.28B no.11
    • /
    • pp.866-875
    • /
    • 1991
  • In this paper, multi pulse excited-linear predictive coding (MPE-LPC), where the correlation eliminated residual signal is modeled by a few pules, is shown to be effective for the compression of electrocardiogram (ECG) data, and a more efficient scheme for a faithful reconstruction of ECG is proposed. The reconstruction charateristic of QRS's and P.T waves is improved using the adaptive pulse allocation (APA), and the compression ratio (CR) can be changed by controlling the mumber of modeling pulses. The performance of the proposed method was evaluated using 10 normal and 10 abnormal ECG data. The proposed method had a better performance than the variable threshold amplitude zone time epoch coding (AZTEC) algorithm and the scan-along polygonal approximation (SAPA) algorithm with the same CR. With the CR in kthe range of 8:1 to 14:1, we could compress ECG data efficiently.

  • PDF

Estimated Action Potentials During Repolarization Phase form the Body Surface Electrocardiogram (심전도의 재분극상에서의 활동전임의 추정)

  • Kang, Hoon;Min, Byoung-Goo;Choi, Keh-Kun
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.20 no.6
    • /
    • pp.81-87
    • /
    • 1983
  • The body surface ECG(electrocardiogram) is produced by the electric fields caused by the propagation of action potentials within the myocardial cells. The repolarization phase of the action potential is very sensitive to factors of clinical importance. Therefore, in this paper of the inverse electrocardiography, we studied a method of estimating the uniform action potentials during repolarization phase from the body surface ECG using digital signal identification techniques. The estimated action potential of a normal was similar to that of clinical data in the repolarization phase.

  • PDF