• 제목/요약/키워드: electro

검색결과 6,451건 처리시간 0.034초

조구(S38)-승산(B57)혈의 전침 자극이 동결견 환자의 관절가동범위에 미치는 영향 (The Effect of Electro-acupuncture Stimulation of Tiaoko(S38)-Chengsan(B57) on Shoulder ROM with Frozen Shoulder Patient)

  • 권오현;한진태;이상열;이명희;배성수
    • 한방재활의학과학회지
    • /
    • 제18권3호
    • /
    • pp.81-90
    • /
    • 2008
  • Objectives : The purpose of this study was to identify the effect of electro-acupuncture stimulation regarding restoration of range of motion on patients with frozen shoulder. Methods : Experimental group measured with shoulder flexion and abduction angle at pre and post electro-acupuncture stimulation. Results : There were statistically significant difference regarding change of flexion angle of electro-acupuncture stimulation(p<0.01) and the testing value of all levels had a significant difference with the value of final post-test(p<0.01). There were statistically significant difference regarding change of abduction angle of electro-acupuncture stimulation(p<0.01). Conclusions : Electro-acupuncture stimulation of distal part increased range of motion of frozen shoulder. Therefore, application of electro-acupuncture should be developed as a therapeutic method in treatment of frozen shoulder. Also, it can contribute as one of good therapeutic methods offered to patients through approach of oriental rehabilitation medicine.

Prevention of Work-related Musculoskeletal Disorders in Grapes Pinching by Using Electro-motion Scissors Designed Ergonomically

  • Chae, Hye-Seon;Kim, Sung-Cheol;Kim, Kwan-Woo;Lee, Kyung-Suk;Kim, Hoy-Cher;Park, Keun-Sang
    • 대한인간공학회지
    • /
    • 제30권6호
    • /
    • pp.749-755
    • /
    • 2011
  • Objective: The purpose of this study is to assess the reducing effect of workload on developed electro-motion scissors. Methods: To achieve this, we measured the pressure distribution, Joint angle of fingers and JSI(Job Strain Index) for electro-motion scissors and hand-operated scissor in objective assessment and surveyed the uncomfortable degree in subjective assessment. Results: As a result, The peak of pressure in the electro-motion scissors was generally lower than the hand-operated scissors. JSI and overall joint angle of fingers for the electro-motion scissors were remarkably lower than the hand-operated scissors. Also, the subjective uncomfortable degree showed that the uncomfortable point of electro-motion scissors were generally lower than the hand operated scissors. Conclusion: The impact of reducing the work load as well as distributing the pressure around the hand by using electro-motion scissors during grapes pinching was confirmed.

태충 유침 및 전침이 병태모델 흰쥐의 장운동에 미치는 영향 (Effect of Acupuncture and Electro-acupuncture at $LR_3$ on Intestinal Motility in Rats)

  • 임성철;이현
    • Journal of Acupuncture Research
    • /
    • 제25권5호
    • /
    • pp.27-42
    • /
    • 2008
  • Objectives : The purpose of this study was to observe the effects of acupuncture and electro-acupuncture at $LR_3$ on intestinal motility in rat. Methods : We made over-activated state of intestinal motility with carbachol and suppressed state of intestinal motility with loperamide in rat and carried out needle retention acupuncture and high frequency electro-acupuncture at $LR_3$ in rat devided into pre-treatment group and post-treatment group. The charcoal travel rate was measured to evaluate the intestinal motility. Results : 1. High frequency electro-acupuncture at $LR_3$ have significant influences on intestinal motility of rat in normal state. 2. Pre-treatment of needle retention acupuncture, high frequency electro-acupuncture significantly decreased intestinal motility in rat which over-activated with carbachol. 3. Post-treatment of high frequency electro-acupuncture significantly increased intestinal motility in rat which suppressed with loperamide. Conclusions : These results suggest that acupuncture and electro-acupuncture at $LR_3$ are effective on intestinal motility in rat.

  • PDF

New Active Snubber Boost PFC Converter for Efficiency Improvement in Home Appliances Applications

  • Jeong, In Wha;Park, Mingyu;Um, Kee-Ju;Heo, Chang Jae;Lee, JunHo;Kim, Kwangsoo;Suh, Bum-Seok;Kim, Yong-Wook;Kim, Rae-Young
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.289-290
    • /
    • 2012
  • This paper proposes a new active snubber boost PFC converter to provide a zero-voltage-switching (ZVS) turn-on condition and reduce electromagnetic interference (EMI) noise in home appliances and renewable energy applications, including solar or fuel cell electric systems. The proposed active snubber circuit enables a main boost switch of the boost-type PFC or grid converter to turn on under a ZVS condition and reduce the switching losses of the main boost switch. Moreover, for the purpose of a specialized intelligent power module (IPM) fabrication, the proposed boost circuit is designed to satisfy some design aspects such as space saving, low cost, and easy fabrication. Simulation and experimental results of a 2kW IPM boost-type PFC converter are provided to verify the effectiveness of the proposed active snubber boost circuit.

  • PDF

잉크젯 헤드내 발생한 기포에 따른 토출 변화 연구 (Studies on Changes of the Droplets by Bubbles in Piezoelectric Inkjet Head)

  • 유영석;김영재;심원철;박창성;박정훈;강필중;정재우;오용수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1544-1545
    • /
    • 2007
  • 본 논문은 피에조방식으로 구동하는 MEMS 구조의 산업용 잉크젯 헤드를 제작하여 잉크를 충진하여 토출하는 과정에서 토출이 되지 않는 원인 중 하나인 기포에 대해서 연구하였다. 기포를 직접 관찰하기 위한 방법으로 투명한 유리로 Membrane을 제작하여 기포가 발생하여 거동하는 모습을 관찰하였으며 Actuator가 구동하는 헤드내 기포를 구동 중에 관찰하기 위한 방법으로 LDV(Laser Doffler Vibrometer)를 이용하였다. 그 결과, 구동하면서 발생하는 변위의 미세한 차이를 관찰할 수 있었으며 주파수 data의 차이를 관찰함으로써 기포의 크기에 따른 토출의 양태를 구별할 수 있었다.

  • PDF

전해연마면의 표면경도 향상을 위한 플라즈마 이온질화 처리법에 관한 실험적 연구 (A experimental study about plasma ion treatment to improve hardness of electro-polished surface)

  • 김진범;홍필기;서태일;손창우
    • Design & Manufacturing
    • /
    • 제13권1호
    • /
    • pp.13-18
    • /
    • 2019
  • The size and prospects of the domestic semiconductor equipment market are increasing every year. In the case of various parts used inside semiconductor equipments, high durability such as high strength and abrasion resistance is demanded. Particularly, the gases used in semiconductor production processes are toxic. In order to prevent such toxic gas leakage, a precision processing technique and a surface treatment technique for preventing corrosion are required. Electro-polishing is an electro-chemical method of polishing a metal surface to make it smooth and polished. Electro-polishing is mainly used in the finishing process of metal surface. Unlike mechanical polishing, electro-polishing is used in many fields, such as fine chemical etching equipment, since no damaged layer or burr, fine polishing groove and particles are generated. However, in order to withstand the gas used in the semiconductor equipment, the parts must have high corrosion resistance. However, the surface hardness generally become lowered through electro-polishing. Therefore, in this study, surface hardness were experimentally observed before and after electro-polishing. Then, a method of improving hardness by preparing a nitrided layer by plasma ion nitriding treatment.

디지털 프린팅을 위한 전도성 배선에 관한 연구 (Investigation of Conductive Pattern Line for Direct Digital Printing)

  • 김용식;서상훈;이로운;김태훈;박재찬;김태구;정경진;윤관수;박성준;정재우
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.502-502
    • /
    • 2007
  • Current thin film process using memory device fabrication process use expensive processes such as manufacturing of photo mask, coating of photo resist, exposure, development, and etching. However, direct printing technology has the merits about simple and cost effective processes because inks are directly injective without mask. And also, this technology has the advantage about fabrication of fine pattern line on various substrates such as PCB, FCPB, glass, polymer and so on. In this work, we have fabricated the fine and thick metal pattern line for the electronic circuit board using metal ink contains Ag nano-particles. Metal lines are fabricated by two types of printing methods. One is a conventional printing method which is able to quick fabrication of fine pattern line, but has various difficulties about thick and high resolution DPI(Dot per Inch) pattern lines because of bulge and piling up phenomenon. Another(Second) methods is sequential printing method which has a various merits of fabrication for fine, thick and high resolution pattern lines without bulge. In this work, conductivities of metal pattern line are investigated with respect to printing methods and pattern thickness. As a result, conductivity of thick pattern is about several un.

  • PDF

Bidirectional Hybrid DWDM-PON for HDTV/Gigabit Ethernet/CATV Applications

  • Lu, Hai-Han;Tsai, Wen-Shing;Chien, Tzu-Shen;Chen, Shih-Hung;Chi, Yu-Chieh;Liao, Che-Wei
    • ETRI Journal
    • /
    • 제29권2호
    • /
    • pp.162-168
    • /
    • 2007
  • A new scheme for bi-directional HDTV/Gigabit Ethernet/CATV transmission over a hybrid dense-wavelength-division-multiplexing passive optical network (DWDM-PON) is proposed and demonstrated. It is based on injection-locked vertical-cavity surface-emitting lasers and distributed-feedback laser diodes as transmitters. Services with 129 HDTV channels, a 1.25 Gbps Gigabit Ethernet connection, and 77 CATV channels are successfully demonstrated over 40 km single-mode fiber links. Good performance of bit error rate, carrier-to-noise ratio, composite second order, and composite triple beat is achieved in our proposed bidirectional DWDM-PON.

  • PDF

유비쿼터스 헬스케어를 위한 무구속 전자청진 하드웨어 시스템 개발 (Development of Wearable Electro-Stethoscope Hardware System for the Ubiquitous Healthcare)

  • 김동준
    • 전기학회논문지
    • /
    • 제56권6호
    • /
    • pp.1139-1143
    • /
    • 2007
  • For the possible application of monitoring or diagnosing heart sounds in an ubiquitous healthcare environment. a small and light electro-stethoscope that can be attached in human body should be exploited. With this aim, this study proposes a new style of electro-stethoscope device that is composed of four hardware modules in wearable style. For this ambulatory heart sound collecting device, the several tests must be performed to check portability and material capability for collecting heart sounds. It turned out to be that the multi-channel electro-stethoscope can detect heart sound signals well even if it is not pinpointed in the accurate stethoscope point on a heart. Consequently, our ambulatory electro-stethoscope hardware system can be applied to monitor or diagnose abnormal heart sounds in the ubiquitous healthcare system.

하전방식에 따른 전기싸이클론의 집진특성 (Collection Characteristics of Electro-Cyclone with Charging Type)

  • 여석준
    • 한국대기환경학회지
    • /
    • 제15권4호
    • /
    • pp.463-473
    • /
    • 1999
  • The main purpose of this study is to investigate the characteristics of precharge electro-cyclone compared to those of innercharge electro-cyclone, experimentally. Especially, the experiment is executed focusing on the improvement of collection efficiency with the charging types including the experimental parameters such as the discharge electrode shapes, applied voltages and gas inlet velocities. Results show that the overall collection efficiency of precharge electro-cyclone is increased over 20% than that of the innercharge type for the same discharge electrode(ø 4 mm, screw rod) in the inlet velocity of 4 m/s, and applied voltage of 30kV. Moreover, the pressure drop of precharge type becomes 10% lower than that of the innercharge type for the inlet velocity of 12 m/s owing to the disturbance of inner vortex flow by the discharge electrode equipped in the center region of cyclone body.

  • PDF