• Title/Summary/Keyword: electricity saving methods

Search Result 17, Processing Time 0.024 seconds

A Development of Energy Storage Monitoring System Architecture for Triboelectric Nanogenerator in the Implant Environment (임플란트 환경에서 TENG 소자를 고려한 효율적인 에너지 저장 모니터링 시스템 개발)

  • Park, Hyun-Moon;Hwang, Tae-Ho;Kim, Dong-Sun
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.2
    • /
    • pp.473-480
    • /
    • 2018
  • In 2012, a new energy capturing method called TENG was suggested for energy harvesting applications. The TENG which captures electric energy in forms of friction or vibration has been researched as a new energy harvesting generation device. However, TENG works on rather high voltage and yields relatively low current, and this requires additional energy conversion and saving methods with either in semiconductive elements or circuitry for its application. Irregular generation from vibration sources rattle under 5Hz especially requires empirical studies. In this article, we suggest a electricity generation platform with energy storage methods. The platform is mounted on large sized animals, and the generation is actively monitored and controlled via Bluetooth-Low Energy to verify the platform.

A Study on the Thermal Conductivity Measurement for Planting Mats of Landscaping (조경용 식생매트의 열전도율 측정에 관한 연구)

  • Cha, Uk Jin;Yang, Geon Seok
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.46 no.6
    • /
    • pp.85-96
    • /
    • 2018
  • Developed nations have implemented various policies to reduce greenhouse gases since the 1997 Kyoto Protocol in order to minimize the effects of global warming. Korea should also reduce energy consumption in the industrial sector, and the transportation and building sectors in order to achieve its greenhouse gas reduction target of 37 percent compared to the Business As Usual levels. The government implements various laws and regulations for reducing energy consumption. To reduce energy consumption in the building sector, in particular, the Energy Conservation Design Standards are enforced according to the 'Enforcement Support for Green Building Construction'. The amount of electricity used to maintain room temperature at $28^{\circ}C$ in these buildings have a 30% reduction (measured on the walls and rooftop) in power usage compared to buildings not required to meet these standards. Although the effect of these energy savings on landscaping is proven, this demonstration is not effective for energy saving since it is not a suitable method for the 'Energy Saving Design Standards of Buildings'. For landscaping to be effective as far as a component of energy reduction, the perfusion rate of the building should be calculated based on the thermal conductivity of the component materials for the energy saving designs with respect to the basis of Article 14 of the Green Building Act. Therefore, the purpose of this study is to ensure that the planting-based mats currently being widely used in the landscape industry can have insulating performance suitable for the 'Energy Saving Design Standards' of Buildings according to the 'Enable Green Building Construction Methods'.

Performance Investigation of Solar-Heating Ocean Thermal Energy Conversion (SH-OTEC) in Korea (태양열 이용 해양온도차발전시스템의 성능 예측)

  • Nguyen, Van Hap;Lee, Geun Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.1
    • /
    • pp.43-49
    • /
    • 2013
  • The use of ocean thermal energy conversion (OTEC) to generate electricity is one of the methods proposed to utilize renewable energy and to protect the environment. In this study, simulations were performed to investigate the effect of weather conditions in the Ulsan region, Korea, on the efficiency of a solar-heating OTEC (SH-OTEC) system. This system utilizes solar thermal energy as the secondary heat source. Various working fluids were also simulated to select one that is suitable for this system. The results showed that R152A, R600, and R600A, in that order, were the most suitable working fluids. The effective area of the solar collector for a $20^{\circ}C$ increase in the collector outlet temperature fluctuated from 50 to $97m^2$ owing to the change in the monthly average solar gain. The annual average efficiency of the SH-OTEC increases to 6.23%, compared to that of a typical conventional OTEC, which is 2-4%.

A Survey on the Electric Power Consumptions of Apartments located at Coastal Area : Yeongdo-gu, Busan, Korea (연안지역 아파트의 전력소비량 실태조사 - 부산광역시 영도구에 대한 사례연구 -)

  • Hwang, Kwang-Il
    • Journal of Navigation and Port Research
    • /
    • v.33 no.3
    • /
    • pp.241-245
    • /
    • 2009
  • Because of the heat island phenomenon and sea wind, there can be thermal conditions' differences around buildings at downtown and coastal area respectively in coastal city, like Busan, Incheon, Mokpo. For the final purpose of the buildings' energy saving design and operation considering of above mentioned environments differences, energy consumption including heating and cooling loads, electric loads are necessary to be accumulated and analyzed in as the database. As a part of this concept, this study aims to survey and analyze each loads of 22 apartments which has at least 100 households respectively and is located at Yeongdo island, Busan, Korea It is cleared that despite the residents living in this district can use sea wind as a natural ventilation and/or cooling methods, they mainly depends on the electric-driven air-conditioners for cooling with window-closed because of anti-salt problems of the sea wind. This leads the maximum power consumption of the surveyed-22-apartments to be appeared in August like that of inland buildings.

Study on Effective EERS Savings Calculating Method through Analysis of Energy Consumption of Electric Motor & Lighting Devices (전동기와 조명기기의 에너지사용 분석을 통해 효과적인 EERS 절감량 산정을 위한 주요인자 도출 연구)

  • Yeom, Jeehoon;Choi, Hanho;Lee, Hyunwoong;Park, Sungwoo;Kim, Changsik;Hahn, Seunghee
    • Journal of Energy Engineering
    • /
    • v.28 no.3
    • /
    • pp.34-41
    • /
    • 2019
  • It is essential to introduce EERS (Energy Efficiency Resource Standards) according to the trend of the era in which energy saving is emphasized, and it is time to settle down in a stable manner. Electric motors and lighting devices, which account for more than 60% of the nation's electricity use, are the most effective items of the EERS. And accurate methods of calculating savings must be preceded. In this study, the operation rate and load rate are measured through the demonstration of energy use at 400 businesses and the measured rates are used for EERS savings calculation. The results imply that the proposed method can be successfully applied to calculate cost-effective and reliable energy savings.

A study of Improvement on Washing and Rinsing Efficiency - Effect of the dissolution of detergent on washing and rinsing efficiency - (세탁 및 헹굼성능 향상 방안 연구 - 세제의 용해가 세탁 및 헹굼 성능에 미치는 영향 -)

  • 이옥기;표상연
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.18 no.1
    • /
    • pp.23-30
    • /
    • 1994
  • The objective of this study was to analyze the effect of the dissolution of detergent on washing and rinsing efficiency, and the possibility of saving detergent in washing. Washing and rinsing efficiency were reviewed in three different ways : A method was to input dissolved detergent by the use of rapid detergent dissolution instrument, B method was to input dissolved detergent beforehand, and C method was to input undissolved detergent. The results were as follows 1. A method > B method > C method was shown in detergency with washing time and three method's gaps were reduced because detergent dissolution effect was reduced by mechanical action in proportion of washing time. Especially, according to detergency of A method of 0.07% and C method of 0.1% was appeared approximately, saving detergent was expected by rapid dissolution of detergent. 2. A method > B method > C method was shown in detergency with washing temperature. As the washing temperature rose, the detergent reached chemically more activated state and become easily soluble. It resulted for the detergent to penetrate and adhere to laundry easily. 3. A method > B method > C method was shown in detergency with detergent concentration and C method was more sensitive than A, B method against change of detergent cocentration. Rapid detergent dissolution made it possible not only to enhance the washing efficiency but also to save the detergent because detergency of A method in low concentration is higher than that of C method. 4. A method $\geq$ B method > C method was shown in rinsing ratio with detergent input method. It indicated input dissolved detergent was advantageous in rinsing. 5. The result of anion surfactant concentration test of each process with detergent input method was shown like that A method In B method > C method in washing and reverse result was shown in rinsing. The anion surfactant concentration of C method was low during washing but high during rinsing. This was identical with previous results which shown the washing and rinsing efficiency improved with dissolved detergent usasge. 6. C method > B method > A method was shown in the degree of remaining detergent after rinsing. There was no remaining detergent after second rinsing in A and B method, but in C method four rinsings were required for the same result. Consequently, in A and B methods, less water and electricity were used, and less abrasion of cloth.

  • PDF

Evaluation of the Oxygen Transfer Parameters (α and F) of a Coarse Bubble Aeration System by Off-gas Column Test (Off-gas Column Test를 이용한 하수처리장 심층포기시스템의 산소전달 매개변수(α와 F)의 산정)

  • Kim, Chul Woong;Lee, Se Ho;Shin, Dong Rok;Lee, Ji Yong;Park, Jae Han;Ahn, Yoon Hee;Ko, Kwang Baik
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.6
    • /
    • pp.1119-1122
    • /
    • 2006
  • Aeration by using diffusers usually requires approximately 50~90% of the total electricity needed to operate WWTP (WasteWater Treatment Plant)s. Accurate evaluation of the oxygen transfer efficiency for an aeration system, and recommendation of a better alternative may help saving WWTP operational costs. Appropriate techniques and methods to achieve this purpose have not been introduced in Korea. In this study, in-process analysis was performed for a coarse bubble aeration system by the off-gas method to evaluate its applicability in Korea. To accomplish this analysis, an off-gas test, unsteady-state clean water test and steady-state off-gas column test was conducted and comparisons to other aeration systems were made. The ${\alpha}$ and the F estimated from the results of the unsteady-state clean water test and the steady-state off-gas column test were 0.61 and 0.90 respectively in a coarse bubble aeration system. The comparison of P.E tube diffusers laid out single spiral roll and ceramic dome diffusers laid out full floor coverage showed that the oxygen transfer efficiency of the coarse bubble aeration system was less than or similar to other aeration systems. But, airflow rates per unit area were 4~5 times greater than other aeration systems. In regards to the oxygen transfer efficiency for airflow rates per unit area, a retrofit to higher efficiency diffusers was urgently needed. This study showed proved that off-gas methods can apply to evaluate diffuser performances to estimate operating factors and to compare other aeration systems in Korea.