Accelerating aging test of distribution lightning arresters (배전용 피뢰기의 가속열화시험)

  • 김주용;송일근;김찬영;이병성;문재덕
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.596-598
    • /
    • 2000
  • This paper presents a new accelerating aging test facility for distribution lightning arresters. Aging parameters of lightning arrester are moisture ingress, electrical stress and surge absorption and so on. In this system, we applied 13.2kV to 6 samples and controled temperature and humidity of chamber and measured leakage currents of the all samples. Also we developed accelerating aging cycle which consists of -35$^{\circ}C$∼90$^{\circ}C$ temperature and 40%∼90% humidity. Through the aging test we found out the leakage current of aged sample increases rapidly according to the temperature rising. Hereafter we can determine the replacement guide of leakage current for field operating arresters and condition assessment of aged samples through this aging test.

  • PDF

Assessment of material analysis for TR CNCE-W (수트리억제 충실 전력 케이블(TR CNCE-W)의 재료에 대한 평가 기술)

  • Soh, Jin-Joong;Shim, Dae-Sub;Kim, Ku-Sub
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.221-222
    • /
    • 2007
  • The test method on materials of electrical power cable are used in accordance with 18 specifications of IEC, ICEA, KS and KEPCO Spec. The validation of test methods were checked and established by solving the problems occurred during the test. These tests are tensile strength, hot creep, shrink back, environmental stress cracking, flammability, oxygen index, absorption coefficient, differential scanning calorimetry, amount of ion in semiconductor, void, amber, contaminant and water tree etc. The performance test of power cable made by A, B, C, D company were evaluated and compared.

  • PDF

A Simulation Test of Load Rejection for Steam Turbine Generator in a 680MW Nuclear Power Plant (680MW 원자력발전소 증기터빈 발전기의 부하차단 모의시험)

  • Choi, In-Kyu;Jeong, Chang-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1605-1606
    • /
    • 2007
  • An electrical generator in power plant is driven and maintained its speed at rated by steam turbine. By the way, after synchronization in parallel with the power system, as the steam flow into turbine can not be reduced fast even though the electrical load is lost, the turbine gets into dangerous situation due to the increase of its speed. At this time, the duty of the turbine governor is to limit the speed to its overspeed trip set point by stopping the steam flow as soon as possible, the test of which is called load rejection test. It is introduced in this paper for a field simulation test of generator load rejection to be implemented on the turbine governor in a 680MW nuclear power plant before its startup.

  • PDF

Design and Test of ESS DC-DC Converter using Zinc-Bromine Redox Flow Battery for Stand-alone Microgrid (Zinc-Bromine 레독스 플로우 배터리를 이용한 독립형 마이크로그리드 ESS DC-DC 컨버터 설계 및 실증)

  • Choe, Jung-Muk;Ra, Sun-Gil;Han, Dong-Hwa;Lee, Yong-Jin;Choe, Gyu-Ha
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.2
    • /
    • pp.106-115
    • /
    • 2014
  • This paper proposes ESS DC-DC Converter using Redox Flow Battery (RFB) for stand-alone microgrid. Price, safety, expandability and dynamics are crucial in ESS. Reports show that Zinc-bromine (ZnBr) RFB is the best choice in ESS. Simple electrical ZnBr RFB model is obtained from charging test. DC-DC converter Inductor current-DClink Voltage model is proposed for the DC microgrid. For the controller design in z-domain, the K-factor method is by considering nature of the digital controller. The control performance has been verified with simulation and hardware experiments. Lastly 10kW DC microgrid using RFB test result is shown.

An Effective Parallel ALPG for High Speed Memory Testing Using Instruction Analyzer (명령어 분석기를 이용한 고속 메모리 테스트를 위한 병렬 ALPG)

  • Yoon, Hyun-Jun;Yang, Myung-Hoon;Kim, Yong-Joon;Park, Young-Kyu;Park, Jae-Seok;Kang, Sung-Ho
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.9
    • /
    • pp.33-40
    • /
    • 2008
  • As the speed of memory is improved vey fast the advanced test equipments are needed to test the ultra-high speed memory devices efficiently. It is necessary to develop the Algorithmic Pattern Generator (ALPG) that tests fast memory devices effectively using the instructions that testers want to use. In this paper, we propose a new parallel ALPG for the ultra-high speed memory testing. The proposed ALPG can generate patterns for fast memory devices at high speed using manual instructions by the Instruction Analyzer.

Electrical Characteristics and Performance Evaluation with Manufacturing Process of Zinc Oxide Varistors (산화아연소자의 성형공정에 따른 전기적 특성과 성능평가)

  • Cho, Han-Goo;Yoon, Han-Soo;Kim, Suk-Soo;Choi, In-Hyuk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.11
    • /
    • pp.1061-1066
    • /
    • 2006
  • This paper presents the electrical characteristics with manufacturing process and performance evaluation of high performance zinc oxide varistors. ZnO varistors were fabricated with typical ceramic production methods with different thickness and the structural and electrical characteristics of ZnO varistors were investigated. All varistors exhibited high density, which was in the range of $5.41{\sim}5.49g/cm^3$. In the electrical properties, the reference voltage increased in the range of $4.410{\sim}5.250kV$ with increasing their thickness and the residual voltage exhibited the same trends as the reference voltage. In the long duration current impulse withstand test, E-2 and F-1 samples failed at the two and four shots of impulse current, respectively, but E-1 and F-2 samples survived 18 shots during the test. Before and after this test, the variation ratio of residual voltage of E-1 and F-2 samples were -0.34 % and 0.05 %, respectively, which were in the acceptance range of 5 %. According to the results of tests, it is thought that if the fabrication process such as insulating coating, sintering condition, and soldering method is improved, these ZnO varistors would be possible to apply to the station class arresters in the near future.

Underwater Discharge Phenomena in Inhomogeneous Electric Fields Caused by Impulse Voltages

  • Lee, Bok-Hee;Kim, Dong-Seong;Choi, Jong-Hyuk
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.2
    • /
    • pp.329-336
    • /
    • 2010
  • The paper describes the electrical and optical properties of underwater discharges in highly inhomogeneous electric fields caused by 1.2/50 ${\mu}s$ impulse voltages as functions of the polarity and amplitude of the applied voltage, and various water conductivities. The electric fields are formed by a point-to-plane electrode system. The formation of air bubbles is associated with a thermal process of the water located at the tip of the needle electrode, and streamer coronas can be initiated in the air bubbles and propagated through the test gap with stepped leaders. The fastest streamer channel experiences the final jump across the test gap. The negative streamer channels not only have more branches but are also more widely spread out than the positive streamer channels. The propagation velocity of the positive streamer is much faster than that of the negative one and, in fact, both these velocities are independent of the water conductivity; in addition the time-lag to breakdown is insensitive to water conductivity. The higher the water conductivity the larger the pre-breakdown energy, therefore, the ionic currents do not contribute to the initiation and propagation of the underwater discharges in the test conditions considered.

Evaluation of the Efficiency Uncertainty for an Inverter-fed Three-Phase Induction Motor (인버터 구동 3상 유도전동기의 효율 불확도 평가)

  • Lee, Ho-Hyun;Park, Han-Seok;Jun, Hee-Deuk;Kim, Dae-Kyong;Woo, Kyung-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.6
    • /
    • pp.724-729
    • /
    • 2018
  • This paper presented an evaluation method for the efficiency uncertainty of an inverter-fed three-phase induction motor using FEM. The motor efficiency in the FEM is calculated by the IEC 60034-2-3 as in the actual test. In the process of evaluating the efficiency uncertainty, the difference between the finite element method and the actual test is the method of calculating the type-A / B standard uncertainty of the input quantity to estimate the efficiency and each losses. For the input quantities which can confirm the instantaneous values with respect to time, the type-A standard uncertainty in the FEM is calculated from the RMS values or average values having separate periods in the steady state. And, the type-B standard uncertainty in the finite element method is assumed to be zero. Also, this paper compared and analyzed the efficiency uncertainty evaluated by the proposed method and the efficiency uncertainty through the actual test.

Trend in Off-Line PD Monitoring with HVAC Testing (배전반 설비의 온라인 모니터링 및 진단의 동향)

  • Yun, Ju-Ho;Hong, Chang-Il;Hwang, Jong-Sun;Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.529-530
    • /
    • 2007
  • The paper considers the relation between on-line monitoring and diagnostics on the one hand and high-voltage (HV) withstand and partial discharge (PD) on-site testing on the other. HV testing supplies the basic data (fingerprints) for diagnostics. In case of warnings by on-line diagnostic systems, off-line withstand and PD testing delivers the best possible information about defects and enables the classification of the risk. Because alternating voltage (AC) is the most important test voltage, the AC generation on site is considered. Frequency tuned resonant (ACRF) test systems are best adapted to on-site conditions. They can be simply combined with PD measuring equipment. The available ACRF test systems and their application to electric power equipment -from cable systems to power transformers - is described.

  • PDF

Development of a Durability Test System for ATPS Used for Automatic Transmission (자동 변속기용 ATPS의 내구성 검사 시스템 개발)

  • Kim, Tae-Kue;Nam, Hyeong-Su;Shin, Eun-Hye;Yoon, Tae-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1585-1586
    • /
    • 2007
  • In this paper, a system of durability test for ATPS(Automatic Transmission Position Switch), which is used for automatic transmission, has been developed. ATPS is the position sensor for an automatic transmission which transforms the gear changes into the electrical signals and transmits them to TCU(Transmission Control Unit). This system can detect the output signals of the sensor, and also it has been designed to control the position and velocity of a motor to realize the sensor's movement under the running state of a car. And a database system and a GUI system have been developed for the systematic output data management and the convenient interface for users. Also, the operation data and the inspection reference data of a motor can be easily changed in this system, and with some modification the system is also able to used for the durability test of the similar products.

  • PDF